VS-E-
・
All specifications are subject to change without notice.
VS100E Specifications
VS 100E
MODEL
ITEMS/UNITS VS100E-3 VS100E-5
VS100E-12 VS100E-15 VS100E-24 VS100E-48
Input
Voltage Range (*2) V AC 85 - 132 or DC 110 - 175
Frequency (*2) Hz 47 - 63
Efciency (Typ) (*1) % 80 85 86 87
Current (Typ) (*1) A 1.6 2.1
Inrush Current (Typ) (*1)(*12) A 30A at Cold Start
Leakage Current (*9) mA Less than 0.5
Output
Nominal Voltage
VDC
3.3 5 12 15 24 48
Maximum Current A 20 8.5 7.0 4.3 2.2
Maximum Power W 66.0 100.0 102.0 105.0 103.2 105.6
Maximum Line Regulation (*3)(*5)
mV 20 48 60 96 192
Maximum Load Regulation (*3)(*6)
mV 40 96 120 150 240
Temperature Coefcient (*3)
Less than 0.02% / °C
Maximum Ripple & Noise(0≤Ta≤70°C) (*3)(*4)
mVp-p
120 150 200
Maximum Ripple & Noise(-10≤Ta<0°C) (*3)(*4)
mVp-p
160 180 240
Hold-up Time (Typ) (*1) ms 20
Voltage Adjustable Range
(*13)
VDC
2.97 - 3.63
4.5 - 5.5
10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 43.2 - 52.8
Function
Over Current Protection (*7)
A 21.0 - 8.92 - 7.35 - 4.51 - 2.31 -
Over Voltage Protection (*8)
VDC
3.80 - 4.46 5.75 - 6.75 13.8 - 16.2 17.3 - 20.3 27.6 - 32.4 55.2 - 64.8
Parallel Operation -
Series Operation Possible
Environment
Operating Temperature (*10)
°C
Convection : -10 - +70 (-10 - +50:100%, +60:70%, +70:20%)
Storage Temperature °C -30 - +85
Operating Humidity
%RH
30 - 90 (No dewdrop)
Storage Humidity
%RH
10 - 95 (No dewdrop)
Vibration At no operating, 10 - 55Hz (Sweep for 1min)
19.6m/s² Constant, X,Y,Z 1hour each.
Shock Less than 196.1m/s²
Cooling Convection Cooling
Isolation
Withstand Voltage Input - FG : 2kVAC (10mA), Input - Output : 2kVAC (10mA)
Output - FG : 500VAC (20mA) for 1min
Isolation Resistance More than 100MΩ at 25°C and 70%RH Output - FG : 500VDC
Standards
Safety Standards
Designed to meet UL60950-1, CSA60950-1, EN60950-1, EN50178(OV II),
DENAN (Section 2).
EMI Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 2,3), -6(Level 3), -8(Level 4), -11
Mechanical
Weight (Typ) g 290
Size (W×H×D) (*11) mm 62 x 29 x 155 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
(*1) At 100VAC, Ta=25°C, nominal output voltage and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 120VAC(50/60Hz).
(*3) Please refer to Fig. A for measurement of line & load regulation and ripple voltage.
(*4) For start up at low ambient temperature and low input voltage, output ripple noise might not meet specication.
However, there is no overshoot at start up and output ripple noise specication can be met after one second.
(*5) 85 - 132VAC, constant load.
(*6) No load-Full load, constant input voltage.
(*7) 3.3, 5V model: Constant current limit and hiccup with automatic recovery.
12 - 48V model: Constant current limit with automatic recovery.
Avoid to operate at over load or short circuit condition for more than 30seconds.
(*8) OVP circuit will shut the output down, manual reset (Re power on).
(*9) Measured by the each measuring method of UL, CSA, EN and DENAN(at 60Hz), Ta=25°C.
(*10) Ratings
- Derating at standard mounting. Refer to output derating curve(A241-01-02_).
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
(*11) Not include lead length on solder side.
(*12) Inrush Current suppressors type. Limits vary according to ambient temperature and in case of re-entry.
(*13) /FV option is for xed output voltage.