CORCOM Product Guide Switch with IEC Connector Compact Size C Series UL Recognized CSA Certified VDE Approved CS CFS Applies to Filtered models only. C Series Specifications Two function power entry module combining a DPST switch and an IEC 320 power line connector. Compact packaging allows a smaller panel cutout with choice of snap-in or flange mounting. Available with general purpose filtering (F models - CFS, CFE), medical application filtering (H models - CHS, CHE) or unfiltered (CS, CE). Terminals allow for easy connection to any wiring scheme. Preconnected terminals from line to switch are available (B Models - CBS, CBE) for reducing OEM wiring time. The medical versions (H models) are designed specifically for health care applications. Their extremely low leakage current allows compliance with UL544 and UL2601 as well as CSA22.2 health care specifications for use with both patient and non-patient care equipment. For more information on UL544 or UL2601, see Appendix C. Note: When using the models with an IEC connector, remember that the leakage current of the companion line cord, GA400, is more significant than that of the filter which may disqualify this line cord from use in patient care applications. Electrical Schematics F Models (CFS, CFE) LINE LOAD H Models (CHS, CHE) LINE LOAD B Models (CBS, CBE) Power On/Off L L Note 1 Note 2 Note 1 Note 2 G G N N Note 1: Jumpers provided on CBS and CBE versions only. Note 2: Location of optional filter Maximum leakage current, each line to ground: F Models H Models @120 VAC 60 Hz: .25 mA 2 A @250 VAC 50 Hz: .40 mA 5 A Hipot rating (one minute): line-to-ground 2250 VDC line-to-line 1450 VDC Operating frequency: 50/60 Hz Rated voltage: 250 VAC Operating voltages: Switch: Unfiltered Push-on Force: 115/230 VAC Double-insulated rated for 10,000 operations at full load. 51 Amp inrush capability. 18 lb/80 N Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Frequency MHz Rating 0.05 0.15 0.5 1 5 F Models 0 1A 10 26 46 48 46 0 3A 8 16 32 36 43 0 6A 4 11 22 27 36 10A 1 4 14 18 27 H Models 0 1A 16 21 37 44 26 14 31 32 26 9 0 3A 0 6A 4 10 22 23 19 10A 2 6 10 15 11 Line-to-line in 50 ohm circuit Current Frequency MHz Rating 0.05 0.15 0.5 1 5 F Models 0 1A 1 3 13 28 62 0 3A 2 6 14 23 65 0 6A 2 6 14 27 46 10A 1 7 14 23 42 H Models 0 1A 1 6 13 29 38 0 3A 1 5 10 22 36 0 6A 1 5 14 20 31 10A 1 4 11 19 32 10 30 47 48 41 33 46 50 50 42 21 24 18 11 10 14 13 9 10 30 67 65 48 44 42 67 58 62 42 34 33 37 26 36 37 38 Resistor location for reference only. 110 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide Switch with IEC Connector Compact Size (Continued) C Series Case Styles CBS, CBE Pre-Connected Terminals CE, CBE* C CBS, CBE Side View B F A CBS Rear View Power Entry Modules 1.04 26.4 Max .211 Max. 5.36 CBE Rear View CS, CBS* Case Dimensions C B (max) C (max) 1.23 31.24 CE, CBE 1.74 44.2 CFS, CHS 1.23 31.24 CFE, CHE 1.74 44.2 .97 24.64 .97 24.64 2.53 64.26 2.53 64.26 1.62 41.17 1.62 41.17 1.62 41.17 1.62 41.17 CS, CBS .211 Max. 5.36 B A A Part No. (max) CFE, CHE D E F .006 .152 .006 .152 .006 .152 1.06 1.54 26.92 39.12 1.06 1.54 26.92 39.12 1.12 1.54 28.5 39.12 1.12 1.54 28.5 39.12 -- 1.417 36.0 -- 1.417 36.0 C Part Numbers .211 Max. 5.36 B F A 01CFS1 03CFS1 06CFS1 10CFS1 10CS1 01CFE1 03CFE1 06CFE1 10CFE1 10CE1 01CHS1 03CHS1 06CHS1 10CHS1 10CBS1 01CHE1 03CHE1 06CHE1 10CHE1 10CBE1 CFS, CHS Recommended Panel Cutout C D .211 Max. 5.36 B A E Typical Dimensions: Mounting Holes: .13 [3.3] Dia. (2) with .23 Dia. x 90 Counter sunk Terminals: .250 [6.35] (3) Holes: .07 [1.8] Dia. .06 R max 1.52 Panel Cutout for thickness of .031.098 [.8-2.5]. Not recommended for plastic panels. For snap-in applications, the D sides of the cutout must have a .02 [.508] radius on the installation side. Snap-in models allow front mounting only. F 111 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com