050/052 PED-PW www.vishay.com Vishay BCcomponents Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring FEATURES * * * * * * * * 051/053 PEC-PW higher CV/volume 050/052 PED-PW long life 105 C 162/163 PLL-PW Very long useful life: 15 000 h at 85 C Low ESR, high ripple current capability High resistance to shock and vibration Polarized aluminum electrolytic capacitors, non-solid electrolyte Large types, cylindrical aluminum case, insulated with a blue sleeve Provided with keyed polarity 050 series also available in solder-lug (SL) versions Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 APPLICATIONS Fig. 1 * * * * QUICK REFERENCE DATA VALUE 050 052 Nominal case size (O D x L in mm) 25 x 30 to 40 x 100 Rated capacitance range 470 F to 47 F to (E6 series), CR 68 000 F 1000 F Tolerance on CR -10 % to +30 % 10 V to 100 V 250 V to 400 V Rated voltage range, UR Category temperature range -40 C to +85 C Endurance test at 85 C 5000 h Useful life at 85 C 15 000 h 250 000 h Useful life at 40 C, 1.4 x IR applied Shelf life at 0 V, 85 C 500 h Based on sectional specification IEC 60384-4 / EN 130300 Climatic category IEC 60068 40 / 085 / 56 DESCRIPTION Computer, telecommunication, and industrial systems Smoothing and filtering Standard and switched mode power supplies Energy storage in pulse systems MARKING The capacitors are marked (where possible) with the following information: * Rated capacitance (in F) * Tolerance on rated capacitance, code letter in accordance with IEC 60062 (Q for -10 % / +30 %) * Rated voltage (in V) * Date code (YYWW or in 2 digits according to IEC 60062) * Name of manufacturer * Code for factory of origin * Polarity of the terminals and "-" sign to indicate the negative terminal, visible from the top and / or side of the capacitor * Code number * Climatic category in accordance with IEC 60068 SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES FOR 050 SERIES (O D x L in mm) CR (F) 470 680 1000 1500 2200 3300 4700 6800 10 000 15 000 22 000 33 000 47 000 68 000 Revision: 13-Oct-16 UR (V) 10 25 x 30 25 x 40 30 x 40 35 x 40 35 x 50 40 x 40 40 x 50 40 x 70 40 x 100 16 25 x 30 25 x 40 30 x 40 35 x 40 35 x 50 40 x 40 40 x 50 40 x 70 40 x 100 - 25 25 x 30 25 x 40 30 x 40 35 x 40 35 x 50 40 x 40 40 x 50 40 x 70 40 x 100 - 40 25 x 30 25 x 40 30 x 40 35 x 40 35 x 50 40 x 40 40 x 50 40 x 70 40 x 100 - 63 25 x 30 25 x 40 30 x 40 35 x 40 35 x 50 40 x 40 40 x 50 40 x 70 40 x 100 - 100 25 x 30 25 x 40 30 x 40 35 x 40 35 x 50 40 x 40 40 x 50 40 x 70 40 x 100 - Document Number: 28345 1 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES FOR 052 SERIES (O D x L in mm) UR (V) CR (F) 250 385 400 47 - 25 x 30 25 x 30 68 - 25 x 40 25 x 40 100 25 x 30 30 x 40 30 x 40 150 25 x 40 35 x 40 35 x 40 30 x 40 35 x 50 35 x 50 - 40 x 40 40 x 40 35 x 40 40 x 50 40 x 50 35 x 50 40 x 70 40 x 70 220 330 470 40 x 40 - - 680 40 x 50 - 40 x 100 1000 40 x 70 - - DIMENSIONS in millimeters AND AVAILABLE FORMS 2.5 O D + 1 max. 10 0.1 L L + 5 max. 1.3 (3 x) 12.5 0.1 4.9 0.2 Case O D = 25 mm Case O D = 25 mm Fig. 2 - Printed wiring pin version Fig. 3 - Mounting hole diagram viewed from component side 2.5 3 - 2 O D + 1 max. 3 15 0.1 1 L + 5 max. 1.3 (4 x) 7.5 0.1 4.9 0.2 Case O D = 30 mm 17.5 0.1 Case O D = 30 mm Fig. 4 - Printed wiring pin version Revision: 13-Oct-16 Fig. 5 - Mounting hole diagram viewed from component side Document Number: 28345 2 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents 2.5 3 - 2 O D + 1 max. 3 15 0.1 L 1 L + 5 max. 1.3 (4 x) 7.5 0.1 17.5 0.1 Case O D = 35 mm 4.9 0.2 Case O D = 35 mm Fig. 6 - Printed wiring pin version Fig. 7 - Mounting hole diagram viewed from component side 1 2.5 3 - 4 2 3 O D + 1 max. 2 4 20 0.1 1 L 1.3 (5 x) L + 5 max. 10 0.1 17.5 0.1 20 0.1 Case O D = 40 mm 4.9 0.2 Case O D = 40 mm Fig. 8 - Printed wiring pin version Fig. 9 - Mounting hole diagram viewed from component side 0.8 O D + 1 max. L L + 2 max. 91 10 0.5 Fig. 10 - Solder-lug versions (SL): only available in 050 series MOUNTING When a number of capacitors are connected in a bank, they must not be closer together than 15 mm, when no derating of ripple current and / or temperature is applied. Pin number 1 is the positive terminal. Pin "-" is the negative terminal. Pin numbers 2, 3 and 4 (if present) should be free from the electrical circuit or connected to the minus terminal. Revision: 13-Oct-16 Document Number: 28345 3 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents Table 1 DIMENSIONS in millimeters, MASS, AND PACKAGING QUANTITIES NOMINAL CASE SIZE ODxL O Dmax. Lmax. SL VERSIONS Lmax. PW VERSIONS MASS (g) CARDBOARD BOX DIMENSIONS LxWxH PACKAGING QUANTITIES (units per box) 25 x 30 26 32 35 24 100 290 x 280 x 50 25 x 40 26 42 45 28 100 290 x 280 x 60 30 x 40 31 42 45 38 100 340 x 330 x 60 35 x 40 36 42 45 51 50 390 x 198 x 60 390 x 198 x 70 35 x 50 36 52 55 66 50 40 x 40 (1) 41 - 45 78 50 440 x 223 x 60 40 x 50 41 52 55 82 50 440 x 223 x 70 40 x 70 41 72 75 110 25 230 x 230 x 90 40 x 100 41 102 105 176 25 230 x 230 x 120 Note (1) Not available in SL versions ORDERING EXAMPLE ELECTRICAL DATA SYMBOL Electrolytic capacitor 050 series 10 000 F / 25 V; -10 % / +30 % DESCRIPTION CR Rated capacitance at 100 Hz Nominal case size: O 35 mm x 50 mm; PW version IR Rated RMS ripple current at 100 Hz, 85 C or at 20 kHz, 70 C Ordering code: MAL2 050 56103 E3 Former 12NC: 2222 050 56103 IL1 Max. leakage current after 1 min at UR IL5 Max. leakage current after 5 min at UR ESR Z Max. equivalent series resistance at 100 Hz Max. impedance at 10 kHz Note * Unless otherwise specified, all electrical values in tables 2 and 3 apply at Tamb = 20 C, P = 86 kPa to 106 kPa, RH = 45 % to 75 % Table 2 ELECTRICAL DATA AND ORDERING INFORMATION FOR 050 SERIES UR (V) 10 CR 100 Hz (F) NOMINAL CASE SIZE ODxL (mm) IR 100 Hz 85 C (A) IR 20 kHz 70 C (A) IL1 1 min (mA) IL5 5 min (mA) ESR 100 Hz (m) Z 10 kHz (m) ORDERING CODE SL MAL2050....... ORDERING CODE PW MAL2050....... 4700 25 x 30 2.4 4.6 0.28 0.10 74 50 14472E3 54472E3 6800 25 x 40 3.2 6.1 0.41 0.14 51 37 14682E3 54682E3 10 000 30 x 40 3.8 7.2 0.60 0.20 39 29 14103E3 54103E3 15 000 35 x 40 4.1 7.8 0.90 0.30 35 26 14153E3 54153E3 22 000 35 x 50 5.0 9.5 1.32 0.44 27 21 14223E3 54223E3 22 000 40 x 40 4.2 8.0 1.32 0.44 36 27 n/a 44223E3 33 000 40 x 50 5.0 9.5 1.98 0.66 29 22 14333E3 54333E3 47 000 40 x 70 6.8 12.9 2.82 0.94 20 17 14473E3 54473E3 68 000 40 x 100 9.2 17.5 4.08 1.36 15 14 14683E3 54683E3 Revision: 13-Oct-16 Document Number: 28345 4 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents ELECTRICAL DATA AND ORDERING INFORMATION FOR 050 SERIES UR (V) CR 100 Hz (F) NOMINAL CASE SIZE ODxL (mm) IR 100 Hz 85 C (A) IR 20 kHz 70 C (A) IL1 1 min (mA) IL5 5 min (mA) ESR 100 Hz (m) Z 10 kHz (m) ORDERING CODE SL MAL2050....... ORDERING CODE PW MAL2050....... 16 3300 4700 6800 10 000 15 000 15 000 22 000 33 000 47 000 25 x 30 25 x 40 30 x 40 35 x 40 35 x 50 40 x 40 40 x 50 40 x 70 40 x 100 2.4 3.1 3.7 4.1 5.0 4.2 5.0 6.7 9.1 4.6 5.9 7.0 7.8 9.5 8.0 9.5 12.7 17.3 0.32 0.45 0.65 0.96 1.44 1.44 2.12 3.17 4.51 0.11 0.15 0.22 0.32 0.48 0.48 0.71 1.06 1.51 75 52 40 36 28 36 29 20 15 50 37 30 27 21 27 22 17 14 15332E3 15472E3 15682E3 15103E3 15153E3 n/a 15223E3 15333E3 15473E3 55332E3 55472E3 55682E3 55103E3 55153E3 45153E3 55223E3 55333E3 55473E3 2200 25 x 30 2.3 4.4 0.33 0.11 78 52 16222E3 56222E3 3300 25 x 40 3.1 5.9 0.49 0.17 53 38 16332E3 56332E3 4700 30 x 40 3.7 7.0 0.70 0.24 42 31 16472E3 56472E3 6800 35 x 40 4.1 7.8 1.02 0.34 37 28 16682E3 56682E3 10 000 35 x 50 5.0 9.5 1.50 0.50 28 21 16103E3 56103E3 10 000 40 x 40 4.2 8.0 1.50 0.50 36 27 n/a 46103E3 15 000 40 x 50 5.0 9.5 2.25 0.75 29 22 16153E3 56153E3 22 000 40 x 70 6.8 12.9 3.30 1.10 20 17 16223E3 56223E3 33 000 40 x 100 9.2 17.5 4.95 1.65 15 14 16333E3 56333E3 1500 25 x 30 2.0 3.8 0.36 0.12 112 68 17152E3 57152E3 2200 25 x 40 2.7 5.1 0.53 0.18 76 51 17222E3 57222E3 3300 30 x 40 3.3 6.3 0.79 0.27 57 41 17332E3 57332E3 4700 35 x 40 3.8 7.2 1.13 0.38 48 35 17472E3 57472E3 6800 35 x 50 4.7 8.9 1.64 0.55 36 27 17682E3 57682E3 25 40 63 100 6800 40 x 40 4.1 7.8 1.64 0.55 45 33 n/a 47682E3 10 000 40 x 50 4.9 9.3 2.40 0.80 35 27 17103E3 57103E3 15 000 40 x 70 6.6 12.5 3.60 1.20 25 20 17153E3 57153E3 22 000 40 x 100 9.0 17.1 5.28 1.76 18 16 17223E3 57223E3 1000 25 x 30 1.8 3.4 0.38 0.13 122 74 18102E3 58102E3 1500 25 x 40 2.5 4.7 0.57 0.19 83 54 18152E3 58152E3 2200 30 x 40 3.1 5.9 0.83 0.28 57 41 18222E3 58222E3 3300 35 x 40 3.6 6.8 1.25 0.42 48 35 18332E3 58332E3 4700 35 x 50 4.4 8.3 1.78 0.60 36 27 18472E3 58472E3 4700 40 x 40 3.8 7.2 1.78 0.60 45 33 n/a 48472E3 6800 40 x 50 4.7 8.9 2.57 0.86 35 27 18682E3 58682E3 10 000 40 x 70 6.2 11.8 3.78 1.26 25 20 18103E3 58103E3 15 000 40 x 100 8.5 16.1 5.67 1.89 18 16 18153E3 58153E3 470 25 x 30 1.4 2.7 0.28 0.10 247 172 19471E3 59471E3 680 25 x 40 1.9 3.6 0.41 0.14 170 116 19681E3 59681E3 1000 30 x 40 2.5 4.7 0.60 0.20 123 88 19102E3 59102E3 1500 35 x 40 3.1 5.8 0.90 0.30 94 71 19152E3 59152E3 2200 35 x 50 3.9 7.4 1.32 0.44 69 55 19222E3 59222E3 2200 40 x 40 3.6 6.8 1.32 0.44 81 65 n/a 49222E3 3300 40 x 50 4.6 8.7 1.98 0.66 59 48 19332E3 59332E3 4700 40 x 70 6.2 11.7 2.82 0.94 42 36 19472E3 59472E3 6800 40 x 100 8.2 15.5 4.08 1.36 32 28 19682E3 59682E3 Revision: 13-Oct-16 Document Number: 28345 5 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents Table 3 ELECTRICAL DATA AND ORDERING INFORMATION FOR 052 SERIES UR (V) 250 385 400 IR 100 Hz 85 C (A) IR 20 kHz 70 C (A) 25 x 30 0.6 1.15 0.15 25 x 40 0.8 1.5 0.23 220 30 x 40 1.0 1.9 0.33 330 35 x 40 1.4 2.65 470 35 x 50 1.8 470 40 x 40 680 40 x 50 1000 40 x 70 47 68 CR 100 Hz (F) NOMINAL CASE SIZE ODxL (mm) 100 150 IL1 1 min (mA) IL5 5 min (mA) ESR 100 Hz (m) Z 10 kHz (m) ORDERING CODE MAL2052....... 0.05 1800 1300 53101E3 0.08 1100 850 53151E3 0.11 750 550 53221E3 0.49 0.17 500 400 53331E3 3.4 0.70 0.24 360 290 53471E3 1.8 3.4 0.70 0.24 420 350 43471E3 2.3 4.4 1.02 0.34 250 190 53681E3 3.0 5.7 1.50 0.50 170 140 53102E3 25 x 30 0.5 0.94 0.11 0.04 2370 1550 58479E3 25 x 40 0.67 1.27 0.16 0.06 1640 1100 58689E3 100 30 x 40 0.84 1.59 0.23 0.08 1275 950 58101E3 150 35 x 40 1.13 2.14 0.34 0.11 850 635 58151E3 220 35 x 50 1.48 2.8 0.50 0.17 580 430 58221E3 220 40 x 40 1.48 2.8 0.50 0.17 580 430 48221E3 330 40 x 50 1.97 3.73 0.75 0.25 385 300 58331E3 470 40 x 70 2.7 5.11 1.06 0.36 270 215 58471E3 47 25 x 30 0.47 0.89 0.11 0.04 2700 2125 56479E3 68 25 x 40 0.63 1.29 0.16 0.06 1875 1470 56689E3 100 30 x 40 0.84 1.59 0.24 0.08 1275 1000 56101E3 150 35 x 40 1.13 2.14 0.36 0.12 850 665 56151E3 220 35 x 50 1.41 2.67 0.52 0.17 650 450 56221E3 220 40 x 40 1.41 2.67 0.52 0.17 650 450 46221E3 330 40 x 50 1.86 3.52 0.79 0.26 435 315 56331E3 470 40 x 70 2.54 4.81 1.12 0.37 305 225 56471E3 680 40 x 100 3.56 6.75 1.63 0.54 210 155 56681E3 ADDITIONAL ELECTRICAL DATA PARAMETER CONDITIONS VALUE 250 V versions Us = 1.15 x UR 385 V versions Us = 1.1 x UR Voltage Surge voltage Urev 1 V Reverse voltage Current Leakage current After 1 min at UR IL1 0.006 CR x UR + 4 A After 5 min at UR IL5 0.002 CR x UR + 4 A Case O D = 25 mm Max. 25 nH Inductance Equivalent series inductance (ESL) Revision: 13-Oct-16 Case O D = 30 mm and 35 mm Max. 30 nH Case O D = 40 mm Max. 35 nH Document Number: 28345 6 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents CAPACITANCE (C) 1.2 1 C C0 Curve 1: 10 V Curve 2: 25 V Curve 3: 63 V Curve 4: 100 V, 250 V, 385 V 1.1 2 3 4 1.0 4 3 0.9 2 0.8 1 0.7 C0 = capacitance at 20 C, 100 Hz 0.6 - 60 - 40 - 20 0 20 40 60 80 Tamb (C) Fig. 11 - Typical multiplier of capacitance as a function of ambient temperature EQUIVALENT SERIES RESISTANCE (ESR) 104 104 Curve 1: case O D x L = 25 x 30 mm Curve 2: case O D x L = 25 x 40 mm Curve 3: case O D x L = 39 x 40 mm Curve 4: case O D x L = 35 x 40 mm Curve 5: case O D x L = 40 x 40 mm Curve 6: case O D x L = 35 x 50 mm Curve 7: case O D x L = 40 x 50 mm Curve 8: case O D x L = 40 x 70 mm Curve 9: case O D x L = 40 x 100 mm ESR (m) 103 1 2 3 4 5 6 7 8 9 102 10 ESR at 100 Hz and UR = 10 V - 50 102 0 1 50 100 Tamb (C) 104 Curve 1: case O D x L = 25 x 30 mm Curve 2: case O D x L = 25 x 40 mm Curve 3: case O D x L = 39 x 40 mm Curve 4: case O D x L = 35 x 40 mm Curve 5: case O D x L = 40 x 40 mm Curve 6: case O D x L = 35 x 50 mm Curve 7: case O D x L = 40 x 50 mm Curve 8: case O D x L = 40 x 70 mm Curve 9: case O D x L = 40 x 100 mm 1 2 3 4 5 6 7 8 9 0 50 100 Tamb (C) Fig. 13 - Typical ESR as a function of temperature 105 Curve 1: case O D x L = 25 x 30 mm Curve 2: case O D x L = 25 x 40 mm Curve 3: case O D x L = 39 x 40 mm Curve 4: case O D x L = 35 x 40 mm Curve 5: case O D x L = 40 x 40 mm Curve 6: case O D x L = 35 x 50 mm Curve 7: case O D x L = 40 x 50 mm Curve 8: case O D x L = 40 x 70 mm ESR (m) 104 102 103 10 102 1 ESR at 100 Hz and UR = 63 V - 50 Fig. 12 - Typical ESR as a function of temperature 103 1 2 3 4 5 6 7 8 9 103 10 1 ESR (m) Curve 1: case O D x L = 25 x 30 mm Curve 2: case O D x L = 25 x 40 mm Curve 3: case O D x L = 39 x 40 mm Curve 4: case O D x L = 35 x 40 mm Curve 5: case O D x L = 40 x 40 mm Curve 6: case O D x L = 35 x 50 mm Curve 7: case O D x L = 40 x 50 mm Curve 8: case O D x L = 40 x 70 mm Curve 9: case O D x L = 40 x 100 mm ESR (m) ESR at 100 Hz and UR = 100 V 1 2 3 4 5 6 7 8 ESR at 100 Hz and UR = 385 V 10 - 50 0 50 100 Tamb (C) Fig. 14 - Typical ESR as a function of temperature Revision: 13-Oct-16 - 50 0 50 100 Tamb (C) Fig. 15 - Typical ESR as a function of temperature Document Number: 28345 7 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents IMPEDANCE (Z) 103 103 Z (m) Curve 1: case O D x L = 25 x 30 mm Curve 2: case O D x L = 25 x 40 mm Curve 3: case O D x L = 39 x 40 mm Curve 4: case O D x L = 35 x 40 mm Curve 5: case O D x L = 40 x 40 mm Curve 6: case O D x L = 35 x 50 mm Curve 7: case O D x L = 40 x 50 mm Curve 8: case O D x L = 40 x 70 mm 1 2 3 4 5 6 7 8 102 10 Z (m) Curve 1: case O D x L = 25 x 30 mm Curve 2: case O D x L = 25 x 40 mm Curve 3: case O D x L = 39 x 40 mm Curve 4: case O D x L = 35 x 40 mm Curve 5: case O D x L = 40 x 40 mm Curve 6: case O D x L = 35 x 50 mm Curve 7: case O D x L = 40 x 50 mm Curve 8: case O D x L = 40 x 70 mm 1 2 3 4 5 6 7 8 102 10 Z = at 10 kHz and UR = 10 V 1 - 50 0 50 100 Tamb (C) - 50 Fig. 16 - Typical impedance as a function of temperature 104 Curve 1: case O D x L = 25 x 30 mm Curve 2: case O D x L = 25 x 40 mm Curve 3: case O D x L = 39 x 40 mm Curve 4: case O D x L = 35 x 40 mm Curve 5: case O D x L = 40 x 40 mm Curve 6: case O D x L = 35 x 50 mm Curve 7: case O D x L = 40 x 50 mm Curve 8: case O D x L = 40 x 70 mm 1 2 3 4 5 6 7 8 Z (m) 103 Z = at 10 kHz and UR = 63 V 1 102 0 50 100 Tamb (C) Fig. 17 - Typical impedance as a function of temperature 105 Curve 1: case O D x L = 25 x 30 mm Curve 2: case O D x L = 25 x 40 mm Curve 3: case O D x L = 39 x 40 mm Curve 4: case O D x L = 35 x 40 mm Curve 5: case O D x L = 40 x 40 mm Curve 6: case O D x L = 35 x 50 mm Curve 7: case O D x L = 40 x 50 mm Curve 8: case O D x L = 40 x 70 mm Z (m) 104 103 1 2 3 4 5 6 7 8 102 10 Z = at 10 kHz and UR = 385 V Z = at 10 kHz and UR = 100 V 1 10 - 50 0 50 100 Tamb (C) - 50 Fig. 18 - Typical impedance as a function of temperature 102 0 50 100 Tamb (C) Fig. 19 - Typical impedance as a function of temperature 102 1 Z () Curve 1: 47 F, 385 V Curve 2: 100 F, 250 V Curve 3: 470 F, 100 V Curve 4: 1000 F, 63 V Curve 5: 4700 F, 10 V 2 10 3 Curve 1: 68 F, 385 V Curve 2: 150 F, 250 V Curve 3: 680 F, 100 V Curve 4: 1500 F, 63 V Curve 5: 6800 F, 10 V 1 Z () 2 10 3 4 4 1 1 5 5 -1 -1 10 10 Case O D x L = 25 x 30 mm 10-2 10-2 10 102 103 104 105 106 f (Hz) 107 Tamb (20 C) Fig. 20 - Typical impedance as a function of temperature Revision: 13-Oct-16 Case O D x L = 25 x 40 mm 10 102 103 104 105 106 f (Hz) 107 Fig. 21 - Typical impedance as a function of temperature Document Number: 28345 8 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents 102 102 Z () 1 10 2 Curve 1: 47 F, 385 V Curve 2: 220 F, 250 V Curve 3: 1000 F, 100 V Curve 4: 2200 F, 63 V Curve 5: 10 000 F, 10 V Z () Curve 1: 150 F, 385 V Curve 2: 330 F, 250 V Curve 3: 1500 F, 100 V Curve 4: 3300 F, 63 V Curve 5: 15 000 F, 10 V 1 10 2 3 3 4 1 1 4 5 5 -1 -1 10 10-2 10 Case O D x L = 35 x 40 mm 102 10 103 10-2 104 105 106 f (Hz) 107 Case O D x L = 35 x 40 mm Fig. 22 - Typical impedance as a function of frequency 103 104 105 106 f (Hz) 107 Fig. 23 - Typical impedance as a function of frequency 102 102 Curve 1: 220 F, 385 V Curve 2: 470 F, 250 V Curve 3: 2200 F, 100 V Curve 4: 4700 F, 63 V Curve 5: 22 000 F, 10 V Z () 1 10 2 1 10 2 3 1 4 4 5 -1 10 5 -1 10 Case O D x L = 35 x 50 mm 10 Curve 1: 220 F, 385 V Curve 2: 470 F, 250 V Curve 3: 2200 F, 100 V Curve 4: 4700 F, 63 V Curve 5: 22 000 F, 10 V Z () 3 1 10-2 102 10 10 2 10 3 10-2 4 10 10 5 6 7 102 10 10 f (Hz) 10 Fig. 24 - Typical impedance as a function of frequency 102 Case O D x L = 40 x 40 mm 103 104 105 106 f (Hz) 107 Fig. 25 - Typical impedance as a function of frequency 102 Curve 1: 330 F, 385 V Curve 2: 250 F, 250 V Curve 3: 3300 F, 100 V Curve 4: 6800 F, 63 V Curve 5: 33 000 F, 10 V Z () 10 1 2 Case O D x L = 40 x 70 mm Z () Curve 1: 470 F, 385 V Curve 2: 1000 F, 250 V Curve 3: 4700 F, 100 V Curve 4: 10 000 F, 63 V Curve 5: 47 000 F, 10 V 10 1 2 1 1 3 3 4 4 -1 -1 10 10-2 10 5 Case O D x L = 40 x 50 mm 10 102 103 10-2 104 105 106 f (Hz) 107 Fig. 26 - Typical impedance as a function of frequency Revision: 13-Oct-16 5 10 102 103 104 105 106 f (Hz) 107 Fig. 27 - Typical impedance as a function of frequency Document Number: 28345 9 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents 102 Curve 1: 6800 F, 100 V Curve 2: 15 000 F, 63 V Curve 3: 68 000 F Z () 10 1 2 1 3 -1 10 Case O D x L = 40 x 100 mm 10-2 10 102 103 104 105 106 f (Hz) 107 Fig. 28 - Typical impedance as a function of frequency RIPPLE CURRENT AND USEFUL LIFE Table 4 ENDURANCE TEST DURATION AND USEFUL LIFE ENDURANCE AT 85 C (h) 5000 USEFUL LIFE AT 85 C (h) 15 000 Note * Multiplier of useful life code: MGA453 MGA453 2.4 IA IR 2.3 2.2 2.1 2.0 1.9 1.8 1.7 1 life multiplier 1. 2 1.6 5 1. 2 3 4 1.4 5 2. 1.5 5 1.3 8 10 1.2 15 0 2 1.1 (1) 30 60 1.0 0.8 0.5 0.0 40 45 IA = Actual ripple current IR = Rated ripple current at 100 Hz and 85 C (1) Useful life at 85 C and IR applied: 15 000 h 50 60 70 80 Tamb (C) 90 Fig. 29 - Multiplier of useful life as a function of ambient temperature and ripple current load Revision: 13-Oct-16 Document Number: 28345 10 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 050/052 PED-PW www.vishay.com Vishay BCcomponents Table 5 MULTIPLIER OF RIPPLE CURRENT (IR) AS A FUNCTION OF FREQUENCY FREQUENCY (Hz) 50 100 200 400 1000 2000 1.15 1.19 1.20 IR MULTIPLIER 0.83 1.00 1.10 Table 6 TEST PROCEDURES AND REQUIREMENTS TEST NAME OF TEST Endurance REFERENCE IEC 60384-4 / EN 130300 subclause 4.13 PROCEDURE (QUICK REFERENCE) REQUIREMENTS Tamb = 85 C; UR applied; 5000 h UR 100 V; C/C: 15 % UR > 100 V; C/C: 10 % ESR 1.3 x spec. limit Z x 2 spec. limit IL5 spec. limit Useful life CECC 30301 subclause 1.8.1 Tamb = 85 C; UR and IR applied; 15 000 h UR 100 V; C/C: 45 % UR 100 V; C/C: 30 % ESR 3 x spec. limit Z 3 x spec. limit IL5 spec. limit no short or open circuit, no visible damage total failure percentage: UR 100 V: 1 %; UR 100 V: 3 % Shelf life (storage at high temperature) IEC 60384-4 / EN 130300 subclause 4.17 Tamb = 85 C; no voltage applied; 500 h After test: UR to be applied for 30 min, 24 h to 48 h before measurement C/C: 10 % ESR 1.2 x spec. limit IL5 2 x spec. limit Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability. Revision: 13-Oct-16 Document Number: 28345 11 For technical questions, contact: aluminumcaps2@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, "Vishay"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. (c) 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED Revision: 08-Feb-17 1 Document Number: 91000