Regulated Converters * Universal input 80-264VAC * 100mW no load power consumption * Isolated output 3.75kVAC / 1 min * EN, UL and CE/EAC certified Description RAC04-C/230 4 Watt Single & Dual Output YEA R 3 arrant w The RAC04-C/230 series are fully certified single and dual regulated AC/DC converters in an encapsulated PCB-mount package style with 3.75kVAC isolation and very low standby power consumption. The converters have SC protected single as well as dual outputs and meet EN55032 class B without any external components. Uses include board-level power supplies, home automation, instrumentation systems and standby applications. AC/DC Converter y !NOT RECOMMENDED FOR NEW DESIGNS! short circuit protection Features ** Continuous Efficiency up to 79% T CONVER T REACH compliant M TS TS C H M PL U D IA N T PRO SEHO LD OU O S PL U D IA N T PRO CO 10 from 10 CO M C R S RoHS 2 + compliant C CONVER RE M E O R C E RE Selection Guide CERTIFIED es EN-60335-1 pp a Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ Load (1) [VAC][VDC] [mA] [%] [F] RAC04-3.3SC/23080-264 3.3 1200 72 10000 RAC04-05SC/23080-264 5 800 75 7200 RAC04-12SC/23080-264 12 333 77 1000 RAC04-15SC/23080-264 15 267 78 820 RAC04-24SC/23080-264 24 167 79 220 RAC04-0512DC/23080-264 5/12 720/33 75 4700/100 RAC04-05DC/23080-264 5 400 76 3300 RAC04-12DC/23080-264 12 166 78 680 lianc E224736 Notes: Note1: measured at 115VAC PREFERRED ALTERNATIVES Please consider these alternatives: Model Numbering RAC04-__ _C/230 Output Voltage RAC04-K/277 Series RAC10-K/277 Series Single or Dual Ordering Examples: e.g. RAC04-3.3SC/230, 3.3VDC single output e.g. RAC04-05DC/230, 5VDC dual output www.recom-power.com REV.: 4/2020 IEC/EN60950-1 certified IEC/EN62368-1 certified UL60950-1 certified CSA/CAN 22.2 60950-1-07 certified CB Report EN55032 compliance EN55024 compliance PA-1 ! NOT RECOMMENDED FOR NEW DESIGNS ! RAC04-C/230 Series AC/DC Converter Specifications (measured at Ta= 25C, nominal input voltage, full load otherwise noted) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. 80VAC 113VDC Input Voltage Range (2) 264VAC 373VDC 115VAC 230VAC Input Current 98mA 64mA <0.5ms cold start at 25C Inrush Current No load Power Consumption 115VAC 230VAC 15A 30A 115VAC/230VAC Input Frequency Range AC Input Hold-up time 115VAC Internal Operating Frequency 100mW 47Hz 440Hz 15ms 100% load at nominal Vin 67kHz Minimum Load 0% 200mVp-p Output Ripple and Noise (3) Notes: Note2: Refer to line derating graph on page PA-4 Note3: Ripple and Noise is measured at 20MHz bandwidth and with a 47F low-ESR electrolytic capacitor in parallel with a 0.1F ceramic capacitor across output RAC04-3.3SC/230 RAC04-05SC/230 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] Efficiency vs. Load 60 50 40 30 10 40 0 10 20 30 40 50 60 70 80 90 10 0 100 0 10 20 30 40 50 60 Output Load [%] Output Load [%] RAC04-12SC/230 RAC04-15SC/230 100 100 90 90 80 80 70 70 60 50 40 30 70 80 90 100 60 50 40 30 115VAC 230VAC 20 10 0 115VAC 230VAC 20 Efficiency [%] Efficiency [%] 50 30 115VAC 230VAC 20 0 60 0 10 20 30 40 50 60 Output Load [%] www.recom-power.com 70 80 90 115VAC 230VAC 20 10 100 0 0 continued on next page REV.: 4/2020 10 20 30 40 50 60 70 80 90 100 Output Load [%] PA-2 ! NOT RECOMMENDED FOR NEW DESIGNS ! RAC04-C/230 Series AC/DC Converter Specifications (measured at Ta= 25C, nominal input voltage, full load otherwise noted) RAC04-24SC/230 RAC04-05DC/230 90 90 80 80 70 70 Efficiency [%] 100 Efficiency [%] 100 60 50 40 30 50 40 30 115VAC 230VAC 20 10 0 60 0 10 20 30 40 50 60 70 80 90 10 0 100 10 20 30 40 50 60 70 Output Load [%] Output Load [%] RAC04-0512DC/230 90 90 80 80 70 70 Efficiency [%] 100 Efficiency [%] 0 RAC04-12DC/230 100 60 50 40 30 80 90 100 60 50 40 30 115VAC 230VAC 20 10 0 115VAC 230VAC 20 0 10 20 30 40 50 60 70 80 90 115VAC 230VAC 20 10 0 100 0 10 20 Output Load [%] 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Output Accuracy Condition single and dual 5V/12V dual assymetrical Line Regulation 90-264VAC Load Regulation 10% to 100% load single and dual 5V/12V dual assymetrical 3.3V, 5V output all others 5V/12V dual assymetrical Value 2.0% typ. 2.0% / 10.0% typ. 0.2% typ. 0.2% / 1.0% typ. 1.0% typ. 0.5% typ. 1.0% / 5.0% typ. PROTECTIONS Parameter Type Value Short Circuit Protection (SCP) automatic recovery Over Voltage Category Isolation Voltage Isolation Resistance OVC II I/P to O/P tested for 1 minute Insulation Grade Leakage Current 3.75kVAC 100M min. reinforced 230VAC / 50Hz 0.25mA max. continued on next page www.recom-power.com REV.: 4/2020 PA-3 ! NOT RECOMMENDED FOR NEW DESIGNS ! RAC04-C/230 Series AC/DC Converter Specifications (measured at Ta= 25C, nominal input voltage, full load otherwise noted) Notes: Note4: Refer to local safety regulations if input over-current protection is also required Protection Circuit FUSE VACin (L) +Vout 0.1F/50V 47F/50V VACin (N) -Vout ENVIRONMENTAL Parameter Condition Operating Temperature Range @ natural convection 0.1m/s Value full load -40C to +65C refer to derating graph -40C to +80C Operating Altitude 2000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2 Vibration according to MIL-STD-810F standard MTBF according to MIL-HDBK-217F, G.B. Derating Graph Line Derating (@ Chamber and natural convection 0.1m/s) 90 90 80 80 70 70 Output Load [%] 100 Output Load [%] 100 60 50 40 60 50 40 30 30 20 20 10 10 0 -40 -20 0 500 x 103 hours +25C 20 40 60 65 0 80 80 90 90 130 155 180 205 230 255 264 305 Input Voltage [VAC] Ambient Temperature [C] SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Information Technology Equipment, General Requirements for Safety (CB Scheme) 1310055-1-CB-M1 Information Technology Equipment, General Requirements for Safety E224736-A21 Audio/video, information and communication technology equipment - Safety requirements EAC AL106051 RU-AT.03.67361 RoHS2+ Standard IEC60950-1:2005, 2nd Edition + A1:2009 UL60950-1, 2nd Edition 2011 CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2011 EN62368-1:2014 IEC62368-1:2014 2nd Edition TP TC 004/020, 2011 RoHS-2011/65/EU + AM-2015/863 continued on next page www.recom-power.com REV.: 4/2020 PA-4 ! NOT RECOMMENDED FOR NEW DESIGNS ! RAC04-C/230 Series AC/DC Converter Specifications (measured at Ta= 25C, nominal input voltage, full load otherwise noted) EMC Compliance Report / File Number Standard / Criterion Electromagnetic compatibility of multimedia equipment - Emission requirements EN55032, Class B T160225D10-E Information technology equipment - Immunity characteristics - Limits and methods of measurement ESD Electrostatic discharge immunity test Air: 2, 4, 8kV Contact: 4kV IEC61000-4-2:2008, Criteria A 3V/m IEC61000-4-3:2010, Criteria A Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity AC Power Port: 1kV Surge Immunity EN55024:2010 IEC61000-4-4:2004 + A1:2010, Criteria A AC Power Port: L-N 1kV Immunity to conducted disturbances, induced by radio-frequency fields IEC61000-4-5:2005, Criteria A AC Power Port: 3V IEC61000-4-6:2008, Criteria A Power Magnetic Field Immunity 50Hz, 1A/m IEC61000-4-8:2009, Criteria A Voltage Dips and Interruptions Voltage Dips: >95% Voltage Dips: 30% Interruptions: >95% IEC61000-4-11:2004, Criteria A IEC61000-4-11:2004, Criteria A IEC61000-4-11:2004, Criteria B DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting PCB black plastic (UL94 V-0) silicone (UL94 V-0) FR4 (UL94 V-0) Dimension (LxWxH) 36.7 x 27.2 x 17.1mm Weight 31.5g typ. Dimension Drawing (mm) 36.7 Pinning information 27.2 embossed logo Pin # 1 2 3 4 5 6 7 36.0 26.5 Single No Pin +Vout -Vout NC VAC in (L) VAC in (N) NC* Dual Dual (assymetric) No Pin No Pin +Vout +5Vout Com Com -Vout +12Vout VAC in (L) VAC in (L) VAC in (N) VAC in (N) NC* NC* 17.1 *Pin 7 is NC but need 4mm minimum clearence to ground for safety NC= no connection Tolerance: xx.x= 0.5mm xx.xx= 0.25mm 21.0 4.0 O0.60.05 Redommended footprint details 21.5 7 7.5 Bottom View 6 O0.9 1 5 21.0 restricted area for PCB layout 2.54 2.54 3.1 3.8 0.1 2 3 4 Top View restricted area for PCB layout 1 2 3.75 www.recom-power.com 7 3 4 6 5 3.75 REV.: 4/2020 PA-5 ! NOT RECOMMENDED FOR NEW DESIGNS ! RAC04-C/230 Series AC/DC Converter Specifications (measured at Ta= 25C, nominal input voltage, full load otherwise noted) PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 32.0 x 27.0mm Packaging Quantity 12pcs Storage Temperature Range -40C to +100C The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 4/2020 PA-6