For more Information
please call
1-800-Belden1
General Description:
18 AWG stranded (7x26) tinned copper conductors, PVC insulation, twisted pair, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
118 7x26 TC - Tinned Copper
Total Number of Conductors: 2
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.5588
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.686
Overall Cable
Overall Nominal Diameter: 5.944 mm
Pair
Pair Color Code Chart:
Number Color
1Black & White
Pair Lay Length & Direction:
Lay Length (mm) Twists (twist/m) Direction
50.800 19.686 Left Hand
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +80°C
Bulk Cable Weight: 35.717 Kg/Km
Max. Recommended Pulling Tension: 200.169 N
Min. Bend Radius/Minor Axis: 63.500 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CL3, CMG
NEC Articles: 800, 725
CEC/C(UL) Specification: CMG
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8461 Multi-Conductor - High-Conductivity Copper Speaker Cable Twisted Jacket Con
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 FT4 Loading
CSA Flame Test: FT4
Suitability
Suitability - Indoor: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
72.182
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
19.2267
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Description Current
10C Temperature Rise 4.8 Amps per conductor @ 20°C ambient
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
8461 060U1000 305 MT 11.793 KG CHROME 2 #18 PVC FRPVC
8461 060U500 152 MT 6.350 KG CHROME 2 #18 PVC FRPVC
8461 060100 30 MT 1.452 KG CHROME 2 #18 PVC FRPVC
8461 0601000 305 MT 12.247 KG CHROME C 2 #18 PVC FRPVC
8461 060500 152 MT 6.124 KG CHROME C 2 #18 PVC FRPVC
8461 0605000 1,524 MT 63.503 KG CHROME 2 #18 PVC FRPVC
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 4 Revision Date: 08-05-2013
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8461 Multi-Conductor - High-Conductivity Copper Speaker Cable Twisted Jacket Con
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8461 Multi-Conductor - High-Conductivity Copper Speaker Cable Twisted Jacket Con