AM5
52
QV (AM5)
SWITCHES
MINIATURE SWITCHES
WITH HIGH PRECISION
Standard type contact gap is 1mm .039inch. Please consult us if
you need more than 1mm .039inch contact gap.
FEATURES
• High precision as a result of designing ideal spring by us-
ing computer analysis
O.P. 14.7
±
0.4mm .579
±
.016inch
• Reliable design with shock resistance min. 980 m/s
2
{100 G}
• High inrush resistance 160A
Wide variety of contact ratings and terminal types
• UL/CSA/VDE/SEMKO approved
TYPICAL APPLICATION
• Home appliances
• Vending machines
• Amusement and communication equipment
• Copiers
• General industrial machines
CONSTRUCTION
1. Silver alloy contact 2. Gold clad contact
ORDERING INFORMATION
Type of
switch Terminals Actuators Guard
1: Bottom COM, SPDT
2: Bottom COM, SPST-NC
3: Bottom COM, SPST-NO
4: Side COM, SPDT
5: Side COM, SPST-NC
6: Side COM, SPST-NO
AM5:
QV
switch
Contact rating
00: 0.1 A (Gold clad)
06: 6 A (Silver alloy)
11: 11 A (Silver alloy)
16: 16 A (Silver alloy)
21: 21A (Silver alloy)*
0: Pin plunger
1: Short hinge lever
2: Hinge lever
3: Long hinge lever
4: Simulated roller lever
5: Short roller lever
6: Roller lever
1. *21 A type is available only for .250 Quick-connect terminal type.
2. O.F. 0.15 N {15 gf} and 0.25 N {25 gf} are available for 0.1 A type .187 Quick-connect terminal and .187 Quick-connect terminal.
3. Not every combination is available. Please refer to the table, “PRODUCT TYPES”.
4. .187 Quick connect/solder terminal and 2.94 N {300 gf} operating force types are custom ordered. Please consult us.
5. When ordering agency standard approved types, please attach the following number to the part number.
9: UL/CSA 6 × 103 rated
4: UL/CSA 105 rated
3: UL/CSA 6 × 103 rated, VDE and SEMKO approved
31: UL/CSA 105 rated, VDE and SEMKO approved
8: VDE and SEMKO approved
Remarks:
Terminals
(A: .187 Quick-
connect/solder
terminal)
C: .187 Quick-
connect terminal
D: .250 Quick-
connect terminal
1: 0.15 N {15 gf}
2: 0.25 N {25 gf}
3: 0.49 N {50 gf}
4: 0.98 N {100 gf}
5: 1.96 N {200 gf}
(6: 2.94 N {300 gf})
7: 3.92 N {400 gf}
Operating force by
pin plunger (max.) R: Right hand
guarded
L: Left hand
guarded
Ex. AM5 0 6 1 0 C 5 R
AM5
53
TERMINALS
.187 Quick-connect terminal
.187 Quick-connect/solder terminal
Bottom COM terminal
Side COM terminal
Dimensions
.187 Quick-connect terminal
Dimensions
.187 Quick-connect/solder terminal
.250 Quick-connect terminal
Bottom COM terminal
Side COM terminal
Dimensions
C
NC
NO
2
3
1
C
NC
NO
2
3
1
6.35
.250
3.2
.126
1.55 dia.
.061 dia.
6.4
.252
4.75
.187
1.2
.047
R1.2
.047 R0.8
.031
6.35
.250
3.2
.126
6.4
.252
4.75
.187
C
NC
NO
2
3
1
C
NC
NO
2
3
1
6.35
8.05
2
.079
.065 dia.
4.15
+.004
0
1.65 dia.
+0.1
0
+0.05
–0.07
.250+.002
–.003
±0.15
.163±.006
+0.1
–0.05
.317+.004
–.002
GUARDS
Guarded types are av ailab le only for Side
COM terminal type (.187 Quick-connect).
All types of bottom COM are not guarded.
Left hand guarded
Right hand guarded
PRODUCT TYPES
1. 0.1A type (Gold clad contact)
.187 Quick-connect terminal (Guardless)
1) Bottom COM terminal
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger
0.15 N {15 gf} AM50010C1 AM50020C1 AM50030C1
0.25 N {25 gf} AM50010C2 AM50020C2 AM50030C2
0.49 N {50 gf} AM50010C3 AM50020C3 AM50030C3
0.98 N {100 gf} AM50010C4 AM50020C4 AM50030C4
1.96 N {200 gf} AM50010C5 AM50020C5 AM50030C5
Short hinge lever 0.59 N {60 gf} AM50011C3 AM50021C3 AM50031C3
1.08 N {110 gf} AM50011C4 AM50021C4 AM50031C4
2.16 N {220 gf} AM50011C5 AM50021C5 AM50031C5
Hinge lever 0.29 N {30 gf} AM50012C3 AM50022C3 AM50032C3
0.59 N {60 gf} AM50012C4 AM50022C4 AM50032C4
1.18 N {120 gf} AM50012C5 AM50022C5 AM50032C5
Long hinge lever 0.15 N {15 gf} AM50013C3 AM50023C3 AM50033C3
0.29 N {30 gf} AM50013C4 AM50023C4 AM50033C4
0.59 N {60 gf} AM50013C5 AM50023C5 AM50033C5
Simulated roller lever 0.29 N {30 gf} AM50014C3 AM50024C3 AM50034C3
0.59 N {60 gf} AM50014C4 AM50024C4 AM50034C4
1.18 N {120 gf} AM50014C5 AM50024C5 AM50034C5
Short roller lever 0.59 N {60 gf} AM50015C3 AM50025C3 AM50035C3
1.08 N {110 gf} AM50015C4 AM50025C4 AM50035C4
2.16 N {220 gf} AM50015C5 AM50025C5 AM50035C5
Roller lever 0.29 N {30 gf} AM50016C3 AM50026C3 AM50036C3
0.59 N {60 gf} AM50016C4 AM50026C4 AM50036C4
1.18 N {120 gf} AM50016C5 AM50026C5 AM50036C5
AM5
54
2) Side COM terminal
Remarks: 1.Regarding side COM terminal types, right hand guarded types and left hand guarded types are available.
When ordering, please attach suffix “R” for right hand guarded types or “L” for left hand guarded types to the part number.
<ex.> Guardless type Right hand guarded type
AM50040C4
AM50040C4R
2.When ordering agency standard approved types, please attach the following number to the part number.
9: UL/CSA 6
×
10
3
rated
4: UL/CSA 10
5
rated
3: UL/CSA 6
×
10
3
rated, VDE and SEMKO approved
31: UL/CSA 10
5
rated, VDE and SEMKO approved
8: VDE and SEMKO approved
3.Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
<ex.> .187 Quick-connect terminal .187 Quick-connect/solder terminal
AM50010C4
AM50010A4
4..250 Quick-connect terminal is available for opening force, 50gf, 100gf, and 200gf types. When ordering, change the eighth digit of part number C to D.
<ex.> .187 Quick-connect terminal .250 Quick-connect terminal
AM50010C3
AM50010D3
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger
0.15 N {15 gf} AM50040C1 AM50050C1 AM50060C1
0.25 N {25 gf} AM50040C2 AM50050C2 AM50060C2
0.49 N {50 gf} AM50040C3 AM50050C3 AM50060C3
0.98 N {100 gf} AM50040C4 AM50050C4 AM50060C4
1.96 N {200 gf} AM50040C5 AM50050C5 AM50060C5
Short hinge lever 0.59 N {60 gf} AM50041C3 AM50051C3 AM50061C3
1.08 N {110 gf} AM50041C4 AM50051C4 AM50061C4
2.16 N {220 gf} AM50041C5 AM50051C5 AM50061C5
Hinge lever 0.29 N {30 gf} AM50042C3 AM50052C3 AM50062C3
0.59 N {60 gf} AM50042C4 AM50052C4 AM50062C4
1.18 N {120 gf} AM50042C5 AM50052C5 AM50062C5
Long hinge lever 0.15 N {15 gf} AM50043C3 AM50053C3 AM50063C3
0.29 N {30 gf} AM50043C4 AM50053C4 AM50063C4
0.59 N {60 gf} AM50043C5 AM50053C5 AM50063C5
Simulated roller lever 0.29 N {30 gf} AM50044C3 AM50054C3 AM50064C3
0.59 N {60 gf} AM50044C4 AM50054C4 AM50064C4
1.18 N {120 gf} AM50044C5 AM50054C5 AM50064C5
Short roller lever 0.59 N {60 gf} AM50045C3 AM50055C3 AM50065C3
1.08 N {110 gf} AM50045C4 AM50055C4 AM50065C4
2.16 N {220 gf} AM50045C5 AM50055C5 AM50065C5
Roller lever 0.29 N {30 gf} AM50046C3 AM50056C3 AM50066C3
0.59 N {60 gf} AM50046C4 AM50056C4 AM50066C4
1.18 N {120 gf} AM50046C5 AM50056C5 AM50066C5
AM5
55
2. 6A type (Silver alloy contact)
.187 Quick-connect terminal (Guardless)
1) Bottom COM terminal
Remarks: 1.Regarding side COM terminal types, right hand guarded types and left hand guarded types are available.
When ordering, please attach suffix “R” for right hand guarded types or “L” for left hand guarded types to the part number.
<ex.> Guardless type Right hand guarded type
AM50640C4
AM50640C4R
2.When ordering agency standard approved types, please attach the following number to the part number.
9: UL/CSA 6
×
10
3
rated
4: UL/CSA 10
5
rated
3: UL/CSA 6
×
10
3
rated, VDE and SEMKO approved
31: UL/CSA 10
5
rated, VDE and SEMKO approved
8: VDE and SEMKO approved
3.Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
<ex.> .187 Quick-connect terminal .187 Quick-connect/solder terminal
AM50610C4
AM50610A4
4.* is a custom order. Please consult us.
5..250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D.
<ex.> .187 Quick-connect terminal .250 Quick-connect terminal
AM50610C3
AM50610D3
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger
0.49 N {50 gf} AM50610C3 AM50620C3 AM50630C3
0.98 N {100 gf} AM50610C4 AM50620C4 AM50630C4
1.96 N {200 gf} AM50610C5 AM50620C5 AM50630C5
*2.94 N {300 gf} AM50610C6 AM50620C6 AM50630C6
3.92 N {400 gf} AM50610C7 AM50620C7 AM50630C7
Short hinge lever
0.59 N {60 gf} AM50611C3 AM50621C3 AM50631C3
1.08 N {110 gf} AM50611C4 AM50621C4 AM50631C4
2.16 N {220 gf} AM50611C5 AM50621C5 AM50631C5
*3.14 N {320 gf} AM50611C6 AM50621C6 AM50631C6
4.12 N {420 gf} AM50611C7 AM50621C7 AM50631C7
Hinge lever
0.29 N {30 gf} AM50612C3 AM50622C3 AM50632C3
0.59 N {60 gf} AM50612C4 AM50622C4 AM50632C4
1.18 N {120 gf} AM50612C5 AM50622C5 AM50632C5
*1.77 N {180 gf} AM50612C6 AM50622C6 AM50632C6
2.35 N {240 gf} AM50612C7 AM50622C7 AM50632C7
Long hinge lever
0.15 N {15 gf} AM50613C3 AM50623C3 AM50633C3
0.29 N {30 gf} AM50613C4 AM50623C4 AM50633C4
0.59 N {60 gf} AM50613C5 AM50623C5 AM50633C5
*0.88 N {90 gf} AM50613C6 AM50623C6 AM50633C6
1.18 N {120 gf} AM50613C7 AM50623C7 AM50633C7
Simulated roller lever
0.29 N {30 gf} AM50614C3 AM50624C3 AM50634C3
0.59 N {60 gf} AM50614C4 AM50624C4 AM50634C4
1.18 N {120 gf} AM50614C5 AM50624C5 AM50634C5
*1.77 N {180 gf} AM50614C6 AM50624C6 AM50634C6
2.35 N {240 gf} AM50614C7 AM50624C7 AM50634C7
Short roller lever
0.59 N {60 gf} AM50615C3 AM50625C3 AM50635C3
1.08 N {110 gf} AM50615C4 AM50625C4 AM50635C4
2.16 N {220 gf} AM50615C5 AM50625C5 AM50635C5
*3.14 N {320 gf} AM50615C6 AM50625C6 AM50635C6
4.12 N {420 gf} AM50615C7 AM50625C7 AM50635C7
Roller lever
0.29 N {30 gf} AM50616C3 AM50626C3 AM50636C3
0.59 N {60 gf} AM50616C4 AM50626C4 AM50636C4
1.18 N {120 gf} AM50616C5 AM50626C5 AM50636C5
*1.77 N {180 gf} AM50616C6 AM50626C6 AM50636C6
2.35 N {240 gf} AM50616C7 AM50626C7 AM50636C7
AM5
56
2) Side COM terminal
Remarks: 1.Regarding side COM terminal types, right hand guarded types and left hand guarded types are available.
When ordering, please attach suffix “R” for right hand guarded types or “L” for left hand guarded types to the part number.
<ex.> Guardless type Right hand guarded type
AM50640C4
AM50640C4R
2.When ordering agency standard approved types, please attach the following number to the part number.
9: UL/CSA 6
×
10
3
rated
4: UL/CSA 10
5
rated
3: UL/CSA 6
×
10
3
rated, VDE and SEMKO approved
31: UL/CSA 10
5
rated, VDE and SEMKO approved
8: VDE and SEMKO approved
3.Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
<ex.> .187 Quick-connect terminal .187 Quick-connect/solder terminal
AM50610C4
AM50610A4
4.* is a custom order. Please consult us.
5..250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D.
<ex.> .187 Quick-connect terminal .250 Quick-connect terminal
AM50610C3
AM50610D3
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger
0.49 N {50 gf} AM50640C3 AM50650C3 AM50660C3
0.98 N {100 gf} AM50640C4 AM50650C4 AM50660C4
1.96 N {200 gf} AM50640C5 AM50650C5 AM50660C5
*2.94 N {300 gf} AM50640C6 AM50650C6 AM50660C6
3.92 N {400 gf} AM50640C7 AM50650C7 AM50660C7
Short hinge lever
0.59 N {60 gf} AM50641C3 AM50651C3 AM50661C3
1.08 N {110 gf} AM50641C4 AM50651C4 AM50661C4
2.16 N {220 gf} AM50641C5 AM50651C5 AM50661C5
*3.14 N {320 gf} AM50641C6 AM50651C6 AM50661C6
4.12 N {420 gf} AM50641C7 AM50651C7 AM50661C7
Hinge lever
0.29 N {30 gf} AM50642C3 AM50652C3 AM50662C3
0.59 N {60 gf} AM50642C4 AM50652C4 AM50662C4
1.18 N {120 gf} AM50642C5 AM50652C5 AM50662C5
*1.77 N {180 gf} AM50642C6 AM50652C6 AM50662C6
2.35 N {240 gf} AM50642C7 AM50652C7 AM50662C7
Long hinge lever
0.15 N {15 gf} AM50643C3 AM50653C3 AM50663C3
0.29 N {30 gf} AM50643C4 AM50653C4 AM50663C4
0.59 N {60 gf} AM50643C5 AM50653C5 AM50663C5
*0.88 N {90 gf} AM50643C6 AM50653C6 AM50663C6
1.18 N {120 gf} AM50643C7 AM50653C7 AM50663C7
Simulated roller lever
0.29 N {30 gf} AM50644C3 AM50654C3 AM50664C3
0.59 N {60 gf} AM50644C4 AM50654C4 AM50664C4
1.18 N {120 gf} AM50644C5 AM50654C5 AM50664C5
*1.77 N {180 gf} AM50644C6 AM50654C6 AM50664C6
2.35 N {240 gf} AM50644C7 AM50654C7 AM50664C7
Short roller lever
0.59 N {60 gf} AM50645C3 AM50655C3 AM50665C3
1.08 N {110 gf} AM50645C4 AM50655C4 AM50665C4
2.16 N {220 gf} AM50645C5 AM50655C5 AM50665C5
*3.14 N {320 gf} AM50645C6 AM50655C6 AM50665C6
4.12 N {420 gf} AM50645C7 AM50655C7 AM50665C7
Roller lever
0.29 N {30 gf} AM50646C3 AM50656C3 AM50666C3
0.59 N {60 gf} AM50646C4 AM50656C4 AM50666C4
1.18 N {120 gf} AM50646C5 AM50656C5 AM50666C5
*1.77 N {180 gf} AM50646C6 AM50656C6 AM50666C6
2.35 N {240 gf} AM50646C7 AM50656C7 AM50666C7
AM5
57
3. 11A type (Silver alloy contact)
.187 Quick-connect terminal (Guardless)
1) Bottom COM terminal
2) Side COM terminal
Remarks: 1.Regarding side COM terminal types, right hand guarded types and left hand guarded types are available.
When ordering, please attach suffix “R” for right hand guarded types or “L” for left hand guarded types to the part number.
<ex.> Guardless type Right hand guarded type
AM51140C4
AM51140C4R
2.When ordering agency standard approved types, please attach the following number to the part number.
9: UL/CSA 6
×
10
3
rated
4: UL/CSA 10
5
rated
3: UL/CSA 6
×
10
3
rated, VDE and SEMKO approved
31: UL/CSA 10
5
rated, VDE and SEMKO approved
8: VDE and SEMKO approved
3.Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
<ex.> .187 Quick-connect terminal .187 Quick-connect/solder terminal
AM51110C4
AM51110A4
4..250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D.
<ex.> .187 Quick-connect terminal .250 Quick-connect terminal
AM51110C4
AM51110D4
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger 0.98 N {100 gf} AM51110C4 AM51120C4 AM51130C4
Short hinge lever 1.08 N {110 gf} AM51111C4 AM51121C4 AM51131C4
Hinge lever 0.59 N {60 gf} AM51112C4 AM51122C4 AM51132C4
Long hinge lever 0.29 N {30 gf} AM51113C4 AM51123C4 AM51133C4
Simulated roller lever 0.59 N {60 gf} AM51114C4 AM51124C4 AM51134C4
Short roller lever 1.08 N {110 gf} AM51115C4 AM51125C4 AM51135C4
Roller lever 0.59 N {60 gf} AM51116C4 AM51126C4 AM51136C4
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger 0.98 N {100 gf} AM51140C4 AM51150C4 AM51160C4
Short hinge lever 1.08 N {110 gf} AM51141C4 AM51151C4 AM51161C4
Hinge lever 0.59 N {60 gf} AM51142C4 AM51152C4 AM51162C4
Long hinge lever 0.29 N {30 gf} AM51143C4 AM51153C4 AM51163C4
Simulated roller lever 0.59 N {60 gf} AM51144C4 AM51154C4 AM51164C4
Short roller lever 1.08 N {110 gf} AM51145C4 AM51155C4 AM51165C4
Roller lever 0.59 N {60 gf} AM51146C4 AM51156C4 AM51166C4
4. 16A type (Silver alloy contact)
.187 Quick-connect terminal (Guardless)
1) Bottom COM terminal
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger 1.96 N {200 gf} AM51610C5 AM51620C5 AM51630C5
*2.94 N {300 gf} AM51610C6 AM51620C6 AM51630C6
3.92 N {400 gf} AM51610C7 AM51620C7 AM51630C7
Short hinge lever 2.16 N {220 gf} AM51611C5 AM51621C5 AM51631C5
*3.14 N {320 gf} AM51611C6 AM51621C6 AM51631C6
4.12 N {420 gf} AM51611C7 AM51621C7 AM51631C7
Hinge lever 1.18 N {120 gf} AM51612C5 AM51622C5 AM51632C5
*1.77 N {180 gf} AM51612C6 AM51622C6 AM51632C6
2.35 N {240 gf} AM51612C7 AM51622C7 AM51632C7
Long hinge lever 0.59 N {60 gf} AM51613C5 AM51623C5 AM51633C5
*0.88 N {90 gf} AM51613C6 AM51623C6 AM51633C6
1.18 N {120 gf} AM51613C7 AM51623C7 AM51633C7
Simulated roller lever 1.18 N {120 gf} AM51614C5 AM51624C5 AM51634C5
*1.77 N {180 gf} AM51614C6 AM51624C6 AM51634C6
2.35 N {240 gf} AM51614C7 AM51624C7 AM51634C7
Short roller lever 2.16 N {220 gf} AM51615C5 AM51625C5 AM51635C5
*3.14 N {320 gf} AM51615C6 AM51625C6 AM51635C6
4.12 N {420 gf} AM51615C7 AM51625C7 AM51635C7
Roller lever 1.18 N {120 gf} AM51616C5 AM51626C5 AM51636C5
*1.77 N {180 gf} AM51616C6 AM51626C6 AM51636C6
2.35 N {240 gf} AM51616C7 AM51626C7 AM51636C7
AM5
58
2) Side COM terminal
Remarks: 1.Regarding side COM terminal types, right hand guarded types and left hand guarded types are available.
When ordering, please attach suffix “R” for right hand guarded types or “L” for left hand guarded types to the part number.
<ex.> Guardless type Right hand guarded type
AM51640C5
AM51640C5R
2.When ordering agency standard approved types, please attach the following number to the part number.
9: UL/CSA 6
×
10
3
rated
4: UL/CSA 10
5
rated
3: UL/CSA 6
×
10
3
rated, VDE and SEMKO approved
31: UL/CSA 10
5
rated, VDE and SEMKO approved
8: VDE and SEMKO approved
3.Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A.
<ex.> .187 Quick-connect terminal .187 Quick-connect/solder terminal
AM51610C5
AM51610A5
4.* is a custom ordered product. Please consult us.
5..250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D.
<ex.> .187 Quick-connect terminal .250 Quick-connect terminal
AM51610C5
AM51610D5
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger 1.96 N {200 gf} AM51640C5 AM51650C5 AM51660C5
*2.94 N {300 gf} AM51640C6 AM51650C6 AM51660C6
3.92 N {400 gf} AM51640C7 AM51650C7 AM51660C7
Short hinge lever 2.16 N {220 gf} AM51641C5 AM51651C5 AM51661C5
*3.14 N {320 gf} AM51641C6 AM51651C6 AM51661C6
4.12 N {420 gf} AM51641C7 AM51651C7 AM51661C7
Hinge lever 1.18 N {120 gf} AM51642C5 AM51652C5 AM51662C5
*1.77 N {180 gf} AM51642C6 AM51652C6 AM51662C6
2.35 N {240 gf} AM51642C7 AM51652C7 AM51662C7
Long hinge lever 0.59 N {60 gf} AM51643C5 AM51653C5 AM51663C5
*0.88 N {90 gf} AM51643C6 AM51653C6 AM51663C6
1.18 N {120 gf} AM51643C7 AM51653C7 AM51663C7
Simulated roller lever 1.18 N {120 gf} AM51644C5 AM51654C5 AM51664C5
*1.77 N {180 gf} AM51644C6 AM51654C6 AM51664C6
2.35 N {240 gf} AM51644C7 AM51654C7 AM51664C7
Short roller lever 2.16 N {220 gf} AM51645C5 AM51655C5 AM51665C5
*3.14 N {320 gf} AM51645C6 AM51655C6 AM51665C6
4.12 N {420 gf} AM51645C7 AM51655C7 AM51665C7
Roller lever 1.18 N {120 gf} AM51646C5 AM51656C5 AM51666C5
*1.77 N {180 gf} AM51646C6 AM51656C6 AM51666C6
2.35 N {240 gf} AM51646C7 AM51656C7 AM51666C7
5. 21A type (Silver alloy contact)
.250 Quick-connect terminal (Guardless)
1) Bottom COM terminal
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger *2.94 N {300 gf} AM52110D6 AM52120D6 AM52130D6
3.92 N {400 gf} AM52110D7 AM52120D7 AM52130D7
Short hinge lever *3.14 N {320 gf} AM52111D6 AM52121D6 AM52131D6
4.12 N {420 gf} AM52111D7 AM52121D7 AM52131D7
Hinge lever *1.77 N {180 gf} AM52112D6 AM52122D6 AM52132D6
2.35 N {240 gf} AM52112D7 AM52122D7 AM52132D7
Long hinge lever *0.88 N {90 gf} AM52113D6 AM52123D6 AM52133D6
1.18 N {120 gf} AM52113D7 AM52123D7 AM52133D7
Simulated roller lever *1.77 N {180 gf} AM52114D6 AM52124D6 AM52134D6
2.35 N {240 gf} AM52114D7 AM52124D7 AM52134D7
Short roller lever *3.14 N {320 gf} AM52115D6 AM52125D6 AM52135D6
4.12 N {420 gf} AM52115D7 AM52125D7 AM52135D7
Roller lever *1.77 N {180 gf} AM52116D6 AM52126D6 AM52136D6
2.35 N {240 gf} AM52116D7 AM52126D7 AM52136D7
AM5
59
2) Side COM terminal
Remarks: 1.When ordering agency standard approved types, please attach the following number to the part number.
9: UL/CSA 6
×
10
3
rated
4: UL/CSA 10
5
rated
3: UL/CSA 6
×
10
3
rated, VDE and SEMKO approved
31: UL/CSA 10
5
rated, VDE and SEMKO approved
8: VDE and SEMKO approved
2.* is a custom ordered product. Please consult us.
Actuator Operating force, Max. Contact arrangement Contact arrangement
SPDT SPST-NC SPST-NO
Pin plunger *2.94 N {300 gf} AM52140D6 AM52150D6 AM52160D6
3.92 N {400 gf} AM52140D7 AM52150D7 AM52160D7
Short hinge lever *3.14 N {320 gf} AM52141D6 AM52151D6 AM52161D6
4.12 N {420 gf} AM52141D7 AM52151D7 AM52161D7
Hinge lever *1.77 N {180 gf} AM52142D6 AM52152D6 AM52162D6
2.35 N {240 gf} AM52142D7 AM52152D7 AM52162D7
Long hinge lever *0.88 N {90 gf} AM52143D6 AM52153D6 AM52163D6
1.18 N {120 gf} AM52143D7 AM52153D7 AM52163D7
Simulated roller lever *1.77 N {180 gf} AM52144D6 AM52154D6 AM52164D6
2.35 N {240 gf} AM52144D7 AM52154D7 AM52164D7
Short roller lever *3.14 N {320 gf} AM52145D6 AM52155D6 AM52165D6
4.12 N {420 gf} AM52145D7 AM52155D7 AM52165D7
Roller lever *1.77 N {180 gf} AM52146D6 AM52156D6 AM52166D6
2.35 N {240 gf} AM52146D7 AM52156D7 AM52166D7
SPECIFICATIONS
1. Contact rating
Type Voltage Resistive load
(cos
φ
]
1) Inductive load
(cos
φ
]
0.6 to 0.7)
Gold clad contact 0.1A type 250V AC 0.1A 0.1A
125V AC 0.1A 0.1A
30V DC 0.1A 0.1A
Silver alloy contact
6A type 250V AC 6A 3A
125V AC 6A 3A
125V DC 0.5A 0.5A
11A type 250V AC 11A 6A
125V AC 11A 6A
125V DC 0.6A 0.6A
16A type 250V AC 16A 10A
125V AC 16A 10A
125V DC 0.6A 0.6A
21A type 250V AC 21A 16A
125V AC 21A 16A
125V DC 0.6A 0.6A
Gold clad contact for low level circuit 6V DC 5mA
12V DC 2mA
24V DC 1mA
AM5
60
2. Characteristics
3. Operating characteristics
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Type 21A type (Silver alloy) 16, 11, 6A type (Silver alloy) 0.1A type (Gold clad)
Expected life
(min.)
Mechanical 10
7
operations (at 60 cpm)
Electrical 10
5
Operations (at rated load 20 cpm) 10
5
operations (at rated load)
2
×
10
6
operations
(at low-level circuit rating)
Insulation resistance 100M
(at 500V DC)
Dielectric
strength
Between terminals 1,000Vrms for 1 min.
Between terminals
and other exposed
metal parts 2,000Vrms for 1 min.
Between terminals
and ground 2,000Vrms for 1 min.
Contact resistance (initial) 50m
(by voltage drop at 1A 6 to 8V DC) 50m
(by voltage drop at 0.1A 6
to 8V DC)
Vibration resistance
(by pin plunger) 10 to 55Hz at simple amplitude of 0.75mm (Contact opening: max. 1msec.)
Shock resistance
(by pin plunger)
(contact opening: max. 1msec.) Min. 294 m/s
2
{30 G}
O.F. 0.49 N {50 gf} max. type
Min. 98 m/s
2
{10 G}
O.F. 0.98 N {100 gf} max. type
Min. 196 m/s
2
{20 G}
O.F. 1.96 N {200 gf} to 3.92 N
{400 gf} max. type Min. 294 m/s
2
{30 G}
O.F. 0.15 N {15 gf} to 0.49 N
{50 gf} max. type Min. 98 m/s
2
{10 G}
O.F. 0.98 N {100 gf} max. type
Min. 196 m/s
2
{20 G}
O.F. 1.96 N {200 gf} max. type
Min. 294 m/s
2
{30 G}
Allowable operating speed 0.1 to 1,000mm/sec. (at pin plunger)
Maximum operating cycle rate 600cpm O.F. 0.15 N {15 gf}, 0.25 N {25 gf}
max. type: 300cpm
Other O.F. types: 600cpm
Ambient temperature –25 to +105
°
C –13 to +221
°
F (Not freezing below 0
°
C 32°F)
Ambient humidity Max. 85% R.H.
Weight 6.3g .222oz
7th digit of part No. 1234567
Operating force, max.
0.15 N {15 gf} 0.25 N {25 gf} 0.49 N {50 gf}
0.98 N {100 gf} 1.96 N {200 gf} 2.94 N {300 gf} 3.92 N {400 gf}
Release force, min.
0.029 N {3 gf} 0.059 N {6 gf} 0.12 N {12 gf} 0.25 N {25 gf} 0.49 N {50 gf} 0.74 N {75 gf}
0.98 N {100 gf}
Pretravel, max. mm inch 1.6 .063 1.4 .055
Movement differential, max. mm inch 0.8 .031 0.4 .016
Overtravel, min. mm inch 0.8 .031 1.0 .039
Operating position mm inch 14.7
±
0.6 .579
±
.024 14.7
±
0.4 .579
±
.016
7th digit of part No. 34567
Operating force, max. 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} 3.14 N {320 gf} 4.12 N {420 gf}
Release force, min. 0.098 N {10 gf} 0.20 N {20 gf} 0.39 N {40 gf} 0.59 N {60 gf} 0.78 N {80 gf}
Pretravel, max. mm inch 1.6 .063
Movement differential, max. mm inch 0.5 .020
Overtravel, min. mm inch 0.9 .035
Operating position mm inch 15.3
±
0.5 .602
±
.020
7th digit of part No. 34567
Operating force, max. 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} 1.77 N {180 gf} 2.35 N {240 gf}
Release force, min. 0.049 N {5 gf} 0.098 N {10 gf} 0.20 N {20 gf} 0.29 N {30 gf} 0.39 N {40 gf}
Pretravel, max. mm inch 3.2 .126
Movement differential, max. mm inch 1.0 .039
Overtravel, min. mm inch 1.4 .055
Operating position mm inch 15.3
±
1.0 .602
±
.039
7th digit of part No. 34567
Operating force, max. 0.15 N {15 gf} 0.29 N {30 gf} 0.59 N {60 gf} 0.88 N {90 gf} 1.18 N {120 gf}
Release force, min. 0.025 N {2.5 gf} 0.049 N {5 gf} 0.098 N {10 gf} 0.15 N {15 gf} 0.20 N {20 gf}
Pretravel, max. mm inch 7.5 .295
Movement differential, max. mm inch 2.0 .079
Overtravel, min. mm inch 2.2 .087
Operating position mm inch 15.3
±
2.6 .602
±
.102
AM5
61
Simulated roller lever
Short roller lever
Roller lever
7th digit of part No. 34567
Operating force, max. 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} 1.77 N {180 gf} 2.35 N {240 gf}
Release force, min. 0.049 N {5 gf} 0.098 N {10 gf} 0.20 N {20 gf} 0.29 N {30 gf} 0.39 N {40 gf}
Pretravel, max. mm inch 3.2 .126
Movement differential, max. mm inch 1.0 .039
Overtravel, min. mm inch 1.4 .055
Operating position mm inch 18.5
±
1.0 .728
±
.039
7th digit of part No. 34567
Operating force, max. 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} 3.14 N {320 gf} 4.12 N {420 gf}
Release force, min. 0.098 N {10 gf} 0.20 N {20 gf} 0.39 N {40 gf} 0.59 N {60 gf} 0.78 N {80 gf}
Pretravel, max. mm inch 1.6 .063
Movement differential, max. mm inch 0.5 .020
Overtravel, min. mm inch 0.9 .035
Operating position mm inch 20.7
±
0.5 .815
±
.020
7th digit of part No. 34567
Operating force, max. 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} 1.77 N {180 gf} 2.35 N {240 gf}
Release force, min. 0.049 N {5 gf} 0.098 N {10 gf} 0.20 N {20 gf} 0.29 N {30 gf} 0.39 N {40 gf}
Pretravel, max. mm inch 3.2 .126
Movement differential, max. mm inch 1.0 .039
Overtravel, min. mm inch 1.4 .055
Operating position mm inch 20.7
±
1.0 .815
±
.039
DIMENSIONS
1. Pin plunger
Bottom COM terminal
(Guardless)
mm inch General tolerance:
±
0.25
±
.010
.187 Quick-connect terminal .250 Quick-connect terminal
(P.T.)
1.4 max.
.055
10.3
.406
3.95
.156
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
13.5
.531
3.4
22.2
2.8
.110
1.8
.071
27.8 1.094
20.2 .795
2.8
.110
C
NO
NC
13
2
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
6.65
.262
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
14.7
(O.P.)
±0.4
.579±.016
12°
42.7
1.681
3.4
22.2
2.8
.110
1.8
.071
27.8 1.094
20.2 .795
2.8
.110
C
NO
NC
13
2
±0.15
.134±.006
±0.1
.874±.004
±1
2
.079 -0.05
+0.1
8.05 -.002
+.004
.317
4.15
–0.07
+0.05
6.35–.003
+.002
.250
±0.15
.163±.006
(P.T.)
1.4 max.
.055
10.3
.406
3.95
.156
–0.05
+0.25
3.1–.002
+.010
.122
2.8
.110
10.3±0.1
.406±.004
15.9
.626
14.7
(O.P.)
±0.4
.579±.016
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
1.65 dia.
+0.1
0
.065 dia.
+.004
0
3.6
.142
4.1
.161
0.8
.0319.3
.366
9.7
.382
10.6
.417
Side COM terminal
(Guardless)
.187 Quick-connect terminal .250 Quick-connect terminal
C
NO
NC
13
2
(P.T.)
1.4 max.
.055
10.3
.406
3.95
.156
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
3.4
22.2
2.8
.110
1.8
.071
27.8 1.094
20.2 .795
2.8
.110
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
6
.236
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
14.7
(O.P.)
±0.4
.579±.016
C
NO
NC
13
2
10.3
.406
3.95
.156
42.7
1.681
3.4
22.2
2.8
.110
1.8
.071
27.8 1.094
20.2 .795
2.8
.110
±0.15
.134±.006
±0.1
.874±.004
2
.079 -0.05
+0.1
8.05 -.002
+.004
.317
4.15
–0.07
+0.05
6.35–.003
+.002
.250
±0.15
.163±.006
(P.T.)
1.4 max.
.055
–0.05
+0.25
3.1–.002
+.010
.122
2.8
.110
10.3±0.1
.406±.004
15.9
.626
14.7
(O.P.)
±0.4
.579±.016
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
1.65 dia.
+0.1
0
.065 dia.
+.004
0
3.6
.142
4.1
.161
0.8
.0319.3
.366
9.8
.386
10.6
.417
AM5
62
Side COM terminal
(Right hand guarded)
mm inch General tolerance:
±
0.25
±
.010
.187 Quick-connect terminal
1.0
.039
0.5
.020
41
1.614
C
NO
NC
13
2
(P.T.)
1.4 max.
.055
10.3
.406
3.95
.156
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
3.4
22.2
2.8
.110
1.8
.071
27.8 1.094
20.2 .795
2.8
.110
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256 20
.787
6
.236
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
14.7
(O.P.)
±0.4
.579±.016
Side COM terminal
(Left hand guarded)
.187 Quick-connect terminal
27.8 1.094
20.2 .795
1.0
.039
0.5
.020
41
1.614
(P.T.)
1.4 max.
.055
10.3
.406
3.95
.156
39.45
1.553
–0.05
+0.25
3.1 –.002
+.010
.122
3.4
22.2
2.8
.110
1.8
.071
2.8
.110
±0.15
.134±.006
±0.1
.874±.004
3.2
.126
6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
20
.787 6
.236
9.3
.366
4.1
.161 0.5
.020
2.8
.110
10.3±0.1
.406±.004 15.9
.626 14.7
(O.P.)
±0.4
.579±.016
Pin plunger characteristic chart
0.1A type
vvvvv
——
6A type
vvvvv
11A type
v
———
16A type ————
vvv
21A type —————
vv
7th digit of part No. 1234567
Operating force, max. 0.15 N {15 gf} 0.25 N {25 gf} 0.49 N {50 gf}
0.98 N {100 gf} 1.96 N {200 gf} 2.94 N {300 gf} 3.92 N {400 gf}
Release force, min. 0.029 N {3 gf} 0.059 N {6 gf} 0.12 N {12 gf} 0.25 N {25 gf} 0.49 N {50 gf} 0.74 N {75 gf}
0.98 N {100 gf}
Pretravel, max. mm inch 1.6 .063 1.4 .055
Movement differential, max. mm inch 0.8 .031 0.4 .016
Overtravel, min. mm inch 0.8 .031 1.0 .039
Operating position mm inch 14.7
±
0.6 .579
±
.024 14.7
±
0.4 .579
±
.016
2. Short hinge lever
27.8 1.094
.870
20.2 .795
C
NO
NC
13
2
±.020
22.1±0.5
(P.T.)
1.6 max.
.063
10.3
.406
5.0
.197
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
13.5
.531
3.4
22.2
2.8
.110
1.8
.071
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
6.65
.262
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
15.3
(O.P.)
±0.5
.602±.020
The dimensions other than drawn above are same as pin plunger type.
0.1A type
vvv
——
6A type
vvvvv
11A type
v
———
16A type
vvv
21A type
vv
7th digit of part No. 34567
Operating force,
Max.
0.59 N
{60 gf} 1.08 N
{110 gf} 2.16 N
{220 gf} 3.14 N
{320 gf} 4.12 N
{420 gf}
Release force,
Min.
0.098 N
{10 gf} 0.20 N
{20 gf} 0.39 N
{40 gf} 0.59 N
{60 gf} 0.78 N
{80 gf}
Pretravel,
max. mm inch 1.6 .063
Movement differential,
max. mm inch 0.5 .020
Overtravel,
min. mm inch 0.9 .035
Operating position
mm inch 15.3
±
0.5 .602
±
.020
AM5
63
3. Hinge lever
mm inch General tolerance:
±
0.25
±
.010
1.40927.8 1.094
20.2 .795
C
NO
NC
13
2
±.020
35.8±0.5
(P.T.)
3.2 max.
.126
10.3
.406
5.0
.197
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
13.5
.531
3.4
22.2
2.8
.110
1.8
.071
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
6.65
.262
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
14.3
(O.P.)
±1.0
.602±.039
The dimensions other than drawn above are same as pin plunger type.
0.1A type
vvv
——
6A type
vvvvv
11A type
v
———
16A type
vvv
21A type
vv
7th digit of part No. 34567
Operating force,
Max.
0.29 N
{30 gf} 0.59 N
{60 gf} 1.18 N
{120 gf} 1.77 N
{180 gf} 2.35 N
{240 gf}
Release force,
Min.
0.049 N
{5 gf} 0.098 N
{10 gf} 0.20 N
{20 gf} 0.29 N
{30 gf} 0.39 N
{40 gf}
Pretravel,
max. mm inch 3.2 .126
Movement differential,
max. mm inch 1.0 .039
Overtravel,
min. mm inch 1.4 .055
Operating position mm
inch 15.3
±
1.0 .602
±
.039
4. Long hinge lever
2.343 27.8 1.094
20.2 .795
C
NO
NC
13
2
±.020
59.5±0.5
(P.T.)
7.5 max.
.295
10.3
.406
5.0
.197
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
13.5
.531
3.4
22.2
2.8
.110
1.8
.071
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
6.65
.262
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
15.3
(O.P.)
±2.6
.602±.102
The dimensions other than drawn above are same as pin plunger type.
0.1A type
vvv
——
6A type
vvvvv
11A type
v
———
16A type
vvv
21A type
vv
7th digit of part No. 34567
Operating force,
Max.
0.15 N
{15 gf} 0.29 N
{30 gf} 0.59 N
{60 gf} 0.88 N
{90 gf} 1.18 N
{120 gf}
Release force,
Min.
0.025 N
{2.5 gf} 0.049 N
{5 gf} 0.098 N
{10 gf} 0.15 N
{15 gf} 0.20 N
{20 gf}
Pretravel,
max. mm inch 7.5 .295
Movement differential,
max. mm inch 2.0 .079
Overtravel,
min. mm inch 2.2 .087
Operating position mm
inch 15.3
±
2.6 .602
±
.102
5. Simulated roller lever
R3
.118
1.291
27.8 1.094
C
NO
NC
13
2
±.020
32.8±0.5
(P.T.)
3.2 max.
.126
10.3
.406
5.0
.197
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
13.5
.531
3.4
22.2
2.8
.110
1.8
.071
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
6.65
.262
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
18.5
(O.P.)
±1.0
.728±.039
20.2 .795
The dimensions other than drawn above are same as pin plunger type.
0.1A type
vvv
——
6A type
vvvvv
11A type
v
———
16A type
vvv
21A type
vv
7th digit of part No. 34567
Operating force,
Max.
0.29 N
{30 gf} 0.59 N
{60 gf} 1.18 N
{120 gf} 1.77 N
{180 gf} 2.35 N
{240 gf}
Release force,
Min.
0.049 N
{5 gf} 0.098 N
{10 gf} 0.20 N
{20 gf} 0.29 N
{30 gf} 0.39 N
{40 gf}
Pretravel,
max. mm inch 3.2 .126
Movement differential,
max. mm inch 1.0 .039
Overtravel,
min. mm inch 1.4 .055
Operating position mm
inch 18.5
±
1.0 .728
±
.039
AM5
64
6. Short roller lever
mm inch General tolerance:
±
0.25
±
.010
.811
27.8 1.094
20.2 .795
C
NO
NC
13
2
±.020
20.6±0.5
(P.T.)
1.6 max.
.063
10.3
.406
4.9
.193
4.8
.189
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
13.5
.531
3.4
22.2
2.8
.110
1.8
.071
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
6.65
.262
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
20.7
(O.P.)
±0.5
.815±.020
The dimensions other than drawn above are same as pin plunger type.
0.1A type
vvv
——
6A type
vvvvv
11A type
v
———
16A type
vvv
21A type
vv
7th digit of part No. 34567
Operating force,
Max.
0.59 N
{60 gf} 1.08 N
{110 gf} 2.16 N
{220 gf} 3.14 N
{320 gf} 4.12 N
{420 gf}
Release force,
Min.
0.098 N
{10 gf} 0.20 N
{20 gf} 0.39 N
{40 gf} 0.59 N
{60 gf} 0.78 N
{80 gf}
Pretravel,
max. mm inch 1.6 .063
Movement differential,
max. mm inch 0.5 .020
Overtravel,
min. mm inch 0.9 .035
Operating position mm
inch 20.7
±
0.5 .815
±
.020
7. Hinge Roller lever
1.346
C
NO
NC
13
2
±.020
34.2±0.5
27.8 1.094
20.2 .795
(P.T.)
3.2 max.
.126
10.3
.406
4.9
.193
4.8
.189
39.45
1.553
–0.05
+0.25
3.1–.002
+.010
.122
13.5
.531
3.4
22.2
2.8
.110
1.8
.071
±0.15
.134±.006
±0.1
.874±.004
3.2
.126 6.35
.250
1.55 dia.
.061
6.4
.252
4.75
.187
3.1 dia.
+0.25
–0.05
.122 dia.
+.010
–.002
5.65
.222
6.5
.256
6.65
.262
9.3
.366
4.1
.161
0.5
.020
2.8
.110
10.3±0.1
.406±.004
15.9
.626
20.7
(O.P.)
±1.0
.815±.039
The dimensions other than drawn above are same as pin plunger type.
0.1A type
vvv
——
6A type
vvvvv
11A type
v
———
16A type
vvv
21A type
vv
7th digit of part No. 34567
Operating force,
Max.
0.29 N
{30 gf} 0.59 N
{60 gf} 1.18 N
{120 gf} 1.77 N
{180 gf} 2.35 N
{240 gf}
Release force,
Min.
0.049 N
{5 gf} 0.098 N
{10 gf} 0.20 N
{20 gf} 0.29 N
{30 gf} 0.39 N
{40 gf}
Pretravel,
max. mm inch 3.2 .126
Movement differential,
max. mm inch 1.0 .039
Overtravel,
min. mm inch 1.4 .055
Operating position mm
inch 20.7
±
1.0 .815
±
.039
NOTES
1. Fastening of the switch body
1) Use flat filister head M3 screws to
mount switches with less than a 5kg-cm
torque. Use of screws washers or adhe-
sive lock is recommended to prevent
loosening of the screws.
2) Check insulation distance between
ground and each terminal.
3) When the operation object is in the
free position, f orce should not be applied
directly to the actuator or pin plunger.
Also force should be applied to the pin
plunger from vertical direction to the
switch.
4) The standard value of overtravel
should be the range of 70% to 100% of
the rated O.T. value.
2. Soldering operations
Soldering should be accomplished in
less than 5 seconds, with a 60 watt iron.
Care should be taken not to apply force
to the terminal during soldering.
3. Varience of operating characteris-
tics
When specifying the s witch, allow +20%
to the listed operating and release f orces.
4. Environment
Avoid using the switches in the following
conditions;
• In corrosive gases, such as silicon gas
• In a dusty environment
5. For switching of inductive loads (re-
lays, solenoids, etc.)
1) In order to prevent damage to contacts
due to the occurrence of arcing, an arc
absorbing circuit should be applied.
2) Care should be taken that occurrence
in A C load possibly shorten the expected
life.
6. Please assure the quality and reli-
ability of the switch under the actual
service condition.
7. Wire lever and other light actuators
are suitable for the types of O.F . 0.15 N
{15 gf} and 0.25 N {25gf} (pin plunger)
Select the actuator with consideration of
applied shock around mounting place
and mounting direction.
8. It is recommended to use Gold clad
contact type in use of low-le vel circuit
rating.
9. Cover and body are press-fitted.
Once it is taken apart, it may cause
change of characteristics.
USE OF CONNECTOR
The .187 Quick-connect terminal and
.250 Quick-connect terminal accept the
all kinds of 1 polarity connectors and the
“Positive Lock” connectors (AMP Co.,
Ltd.)
Please contact the manuf acturers directly.
• receptacle terminal
.250 series .187 series
“Positive Lock” connector AMP Co.,
Ltd. (equipped with the lock construc-
tion of low insertion type)
.187 type
(1 polarity)
.250 type
(1 polarity)
.187 type
(2 polarities)
.187 type
(3 polarities)
<CUSTOM ORDERED PRODUCT>
65
QV (AM5)
SWITCHES
MINIATURE SWITCHES
WITH HIGH PRECISION
(Contact gap: more than
1mm .039inch type)
• Conforms with the IEC950 standards for secondary circuit
insulation distance.
Assures a contact gap of at least 1mm .039inch
• Can handle high-capacity loads on the secondary side that
S-type size switches cannot
• High inrush and hard impacts resistant
• Excellent operating position precision
• UL/CSA/VDE/SEMKO approved
PRODUCT TYPES
Contact rating: 0.1A, 6A, 11A, 16A (250V AC)
Terminal shape: .187 Quick connect terminal, .187 Quick connect/solder terminal
For other specifications, please consult us.
DIMENSIONS AND NOTES
Please refer to Standard QV switches catalog for dimensions and notes.
SPECIFICATIONS
• Contact ratings (0.1 to 16 A)
Remark: The inductive load for DC should have a time constant of 7 ms or less.
Voltage Resistive load
(cos
φ
= 1.0) Inductive load
(cos
φ
]
0.6 to 0.7)
Type 0.1A 6A 11A 16A 0.1A 6A 11A 16A
250V AC 0.1A 6A 11A 16A 0.1A 3A 6A 10A
125V AC 0.1A 6A 11A 16A 0.1A 3A 6A 10A
125V DC 0.1A 0.5A 0.6A 0.6A 0.1A 0.5A 0.6A 0.6A
• Low-level circuit type
DC 6V 5mA (Resistive load)
DC 12V 2mA (Resistive load)
DC 24V 1mA (Resistive load)
Please consult us for further information.