AM5 QV (AM5) SWITCHES MINIATURE SWITCHES WITH HIGH PRECISION FEATURES * High precision as a result of designing ideal spring by using computer analysis O.P. 14.70.4mm .579.016inch * Reliable design with shock resistance min. 980 m/s2 {100 G} * High inrush resistance 160A * Wide variety of contact ratings and terminal types * UL/CSA/VDE/SEMKO approved TYPICAL APPLICATION * Home appliances * Vending machines * Amusement and communication equipment * Copiers * General industrial machines Standard type contact gap is 1mm .039inch. Please consult us if you need more than 1mm .039inch contact gap. CONSTRUCTION 1. Silver alloy contact 2. Gold clad contact ORDERING INFORMATION Ex. AM5 Type of switch AM5: QV switch 0 6 Contact rating Terminals 00: 0.1 A (Gold clad) 06: 6 A (Silver alloy) 11: 11 A (Silver alloy) 16: 16 A (Silver alloy) 21: 21A (Silver alloy)* 1: Bottom COM, SPDT 2: Bottom COM, SPST-NC 3: Bottom COM, SPST-NO 4: Side COM, SPDT 5: Side COM, SPST-NC 6: Side COM, SPST-NO 1 0 Actuators C 5 R Terminals 0: Pin plunger (A: .187 Quick1: Short hinge lever connect/solder 2: Hinge lever terminal) 3: Long hinge lever C: .187 Quick4: Simulated roller lever connect terminal 5: Short roller lever D: .250 Quick6: Roller lever connect terminal Operating force by pin plunger (max.) 1: 0.15 N {15 gf} 2: 0.25 N {25 gf} 3: 0.49 N {50 gf} 4: 0.98 N {100 gf} 5: 1.96 N {200 gf} (6: 2.94 N {300 gf}) 7: 3.92 N {400 gf} Guard R: Right hand guarded L: Left hand guarded Remarks: 1. *21 A type is available only for .250 Quick-connect terminal type. 2. O.F. 0.15 N {15 gf} and 0.25 N {25 gf} are available for 0.1 A type .187 Quick-connect terminal and .187 Quick-connect terminal. 3. Not every combination is available. Please refer to the table, "PRODUCT TYPES". 4. .187 Quick connect/solder terminal and 2.94 N {300 gf} operating force types are custom ordered. Please consult us. 5. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA 6 x 103 rated 4: UL/CSA 105 rated 3: UL/CSA 6 x 103 rated, VDE and SEMKO approved 31: UL/CSA 105 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 52 AM5 TERMINALS GUARDS .187 Quick-connect terminal .187 Quick-connect/solder terminal Bottom COM terminal .250 Quick-connect terminal Bottom COM terminal Left hand guarded NC 2 1 3 NC 1 2 3 Guarded types are available only for Side COM terminal type (.187 Quick-connect). All types of bottom COM are not guarded. NO C NO C Side COM terminal Side COM terminal NC NC 1 2 3 Right hand guarded 2 1 NO 3 NO C C Dimensions .187 Quick-connect terminal Dimensions 1.55 dia. .061 dia. 1.65 +0.1 0 dia. .065 +.004 dia. 0 4.75 6.4 .187 .252 6.35 +0.05 -0.07 .250 +.002 -.003 3.2 .126 6.35 .250 2 .079 4.15 0.15 .163 .006 8.05 .317 +0.1 -0.05 +.004 -.002 Dimensions .187 Quick-connect/solder terminal R1.2 .047 1.2 .047 R0.8 .031 4.75 6.4 .187 .252 3.2 .126 6.35 .250 PRODUCT TYPES 1. 0.1A type (Gold clad contact) .187 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. 0.15 N {15 gf} 0.25 N {25 gf} 0.49 N {50 gf} 0.98 N {100 gf} 1.96 N {200 gf} 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} 0.15 N {15 gf} 0.29 N {30 gf} 0.59 N {60 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} Contact arrangement SPDT AM50010C1 AM50010C2 AM50010C3 AM50010C4 AM50010C5 AM50011C3 AM50011C4 AM50011C5 AM50012C3 AM50012C4 AM50012C5 AM50013C3 AM50013C4 AM50013C5 AM50014C3 AM50014C4 AM50014C5 AM50015C3 AM50015C4 AM50015C5 AM50016C3 AM50016C4 AM50016C5 Contact arrangement SPST-NC SPST-NO AM50020C1 AM50030C1 AM50020C2 AM50030C2 AM50020C3 AM50030C3 AM50020C4 AM50030C4 AM50020C5 AM50030C5 AM50021C3 AM50031C3 AM50021C4 AM50031C4 AM50021C5 AM50031C5 AM50022C3 AM50032C3 AM50022C4 AM50032C4 AM50022C5 AM50032C5 AM50023C3 AM50033C3 AM50023C4 AM50033C4 AM50023C5 AM50033C5 AM50024C3 AM50034C3 AM50024C4 AM50034C4 AM50024C5 AM50034C5 AM50025C3 AM50035C3 AM50025C4 AM50035C4 AM50025C5 AM50035C5 AM50026C3 AM50036C3 AM50026C4 AM50036C4 AM50026C5 AM50036C5 53 AM5 2) Side COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. 0.15 N {15 gf} 0.25 N {25 gf} 0.49 N {50 gf} 0.98 N {100 gf} 1.96 N {200 gf} 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} 0.15 N {15 gf} 0.29 N {30 gf} 0.59 N {60 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} Contact arrangement SPDT AM50040C1 AM50040C2 AM50040C3 AM50040C4 AM50040C5 AM50041C3 AM50041C4 AM50041C5 AM50042C3 AM50042C4 AM50042C5 AM50043C3 AM50043C4 AM50043C5 AM50044C3 AM50044C4 AM50044C5 AM50045C3 AM50045C4 AM50045C5 AM50046C3 AM50046C4 AM50046C5 Contact arrangement SPST-NC SPST-NO AM50050C1 AM50060C1 AM50050C2 AM50060C2 AM50050C3 AM50060C3 AM50050C4 AM50060C4 AM50050C5 AM50060C5 AM50051C3 AM50061C3 AM50051C4 AM50061C4 AM50051C5 AM50061C5 AM50052C3 AM50062C3 AM50052C4 AM50062C4 AM50052C5 AM50062C5 AM50053C3 AM50063C3 AM50053C4 AM50063C4 AM50053C5 AM50063C5 AM50054C3 AM50064C3 AM50054C4 AM50064C4 AM50054C5 AM50064C5 AM50055C3 AM50065C3 AM50055C4 AM50065C4 AM50055C5 AM50065C5 AM50056C3 AM50066C3 AM50056C4 AM50066C4 AM50056C5 AM50066C5 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix "R" for right hand guarded types or "L" for left hand guarded types to the part number. Guardless type Right hand guarded type AM50040C4 AM50040C4R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA 6 x 103 rated 4: UL/CSA 105 rated 3: UL/CSA 6 x 103 rated, VDE and SEMKO approved 31: UL/CSA 105 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. .187 Quick-connect terminal .187 Quick-connect/solder terminal AM50010C4 AM50010A4 4. .250 Quick-connect terminal is available for opening force, 50gf, 100gf, and 200gf types. When ordering, change the eighth digit of part number C to D. .187 Quick-connect terminal .250 Quick-connect terminal AM50010C3 AM50010D3 54 AM5 2. 6A type (Silver alloy contact) .187 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. 0.49 N {50 gf} 0.98 N {100 gf} 1.96 N {200 gf} *2.94 N {300 gf} 3.92 N {400 gf} 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} *3.14 N {320 gf} 4.12 N {420 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} 0.15 N {15 gf} 0.29 N {30 gf} 0.59 N {60 gf} *0.88 N {90 gf} 1.18 N {120 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} *3.14 N {320 gf} 4.12 N {420 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} Contact arrangement SPDT AM50610C3 AM50610C4 AM50610C5 AM50610C6 AM50610C7 AM50611C3 AM50611C4 AM50611C5 AM50611C6 AM50611C7 AM50612C3 AM50612C4 AM50612C5 AM50612C6 AM50612C7 AM50613C3 AM50613C4 AM50613C5 AM50613C6 AM50613C7 AM50614C3 AM50614C4 AM50614C5 AM50614C6 AM50614C7 AM50615C3 AM50615C4 AM50615C5 AM50615C6 AM50615C7 AM50616C3 AM50616C4 AM50616C5 AM50616C6 AM50616C7 Contact arrangement SPST-NC SPST-NO AM50620C3 AM50630C3 AM50620C4 AM50630C4 AM50620C5 AM50630C5 AM50620C6 AM50630C6 AM50620C7 AM50630C7 AM50621C3 AM50631C3 AM50621C4 AM50631C4 AM50621C5 AM50631C5 AM50621C6 AM50631C6 AM50621C7 AM50631C7 AM50622C3 AM50632C3 AM50622C4 AM50632C4 AM50622C5 AM50632C5 AM50622C6 AM50632C6 AM50622C7 AM50632C7 AM50623C3 AM50633C3 AM50623C4 AM50633C4 AM50623C5 AM50633C5 AM50623C6 AM50633C6 AM50623C7 AM50633C7 AM50624C3 AM50634C3 AM50624C4 AM50634C4 AM50624C5 AM50634C5 AM50624C6 AM50634C6 AM50624C7 AM50634C7 AM50625C3 AM50635C3 AM50625C4 AM50635C4 AM50625C5 AM50635C5 AM50625C6 AM50635C6 AM50625C7 AM50635C7 AM50626C3 AM50636C3 AM50626C4 AM50636C4 AM50626C5 AM50636C5 AM50626C6 AM50636C6 AM50626C7 AM50636C7 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix "R" for right hand guarded types or "L" for left hand guarded types to the part number. Guardless type Right hand guarded type AM50640C4 AM50640C4R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA 6 x 103 rated 4: UL/CSA 105 rated 3: UL/CSA 6 x 103 rated, VDE and SEMKO approved 31: UL/CSA 105 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. .187 Quick-connect terminal .187 Quick-connect/solder terminal AM50610C4 AM50610A4 4. * is a custom order. Please consult us. 5. .250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D. .187 Quick-connect terminal .250 Quick-connect terminal AM50610C3 AM50610D3 55 AM5 2) Side COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. 0.49 N {50 gf} 0.98 N {100 gf} 1.96 N {200 gf} *2.94 N {300 gf} 3.92 N {400 gf} 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} *3.14 N {320 gf} 4.12 N {420 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} 0.15 N {15 gf} 0.29 N {30 gf} 0.59 N {60 gf} *0.88 N {90 gf} 1.18 N {120 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} 0.59 N {60 gf} 1.08 N {110 gf} 2.16 N {220 gf} *3.14 N {320 gf} 4.12 N {420 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} Contact arrangement SPDT AM50640C3 AM50640C4 AM50640C5 AM50640C6 AM50640C7 AM50641C3 AM50641C4 AM50641C5 AM50641C6 AM50641C7 AM50642C3 AM50642C4 AM50642C5 AM50642C6 AM50642C7 AM50643C3 AM50643C4 AM50643C5 AM50643C6 AM50643C7 AM50644C3 AM50644C4 AM50644C5 AM50644C6 AM50644C7 AM50645C3 AM50645C4 AM50645C5 AM50645C6 AM50645C7 AM50646C3 AM50646C4 AM50646C5 AM50646C6 AM50646C7 Contact arrangement SPST-NC SPST-NO AM50650C3 AM50660C3 AM50650C4 AM50660C4 AM50650C5 AM50660C5 AM50650C6 AM50660C6 AM50650C7 AM50660C7 AM50651C3 AM50661C3 AM50651C4 AM50661C4 AM50651C5 AM50661C5 AM50651C6 AM50661C6 AM50651C7 AM50661C7 AM50652C3 AM50662C3 AM50652C4 AM50662C4 AM50652C5 AM50662C5 AM50652C6 AM50662C6 AM50652C7 AM50662C7 AM50653C3 AM50663C3 AM50653C4 AM50663C4 AM50653C5 AM50663C5 AM50653C6 AM50663C6 AM50653C7 AM50663C7 AM50654C3 AM50664C3 AM50654C4 AM50664C4 AM50654C5 AM50664C5 AM50654C6 AM50664C6 AM50654C7 AM50664C7 AM50655C3 AM50665C3 AM50655C4 AM50665C4 AM50655C5 AM50665C5 AM50655C6 AM50665C6 AM50655C7 AM50665C7 AM50656C3 AM50666C3 AM50656C4 AM50666C4 AM50656C5 AM50666C5 AM50656C6 AM50666C6 AM50656C7 AM50666C7 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix "R" for right hand guarded types or "L" for left hand guarded types to the part number. Guardless type Right hand guarded type AM50640C4 AM50640C4R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA 6 x 103 rated 4: UL/CSA 105 rated 3: UL/CSA 6 x 103 rated, VDE and SEMKO approved 31: UL/CSA 105 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. .187 Quick-connect terminal .187 Quick-connect/solder terminal AM50610C4 AM50610A4 4. * is a custom order. Please consult us. 5. .250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D. .187 Quick-connect terminal .250 Quick-connect terminal AM50610C3 AM50610D3 56 AM5 3. 11A type (Silver alloy contact) .187 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. 0.98 N {100 gf} 1.08 N {110 gf} 0.59 N {60 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.08 N {110 gf} 0.59 N {60 gf} Contact arrangement SPDT AM51110C4 AM51111C4 AM51112C4 AM51113C4 AM51114C4 AM51115C4 AM51116C4 Contact arrangement SPST-NC SPST-NO AM51120C4 AM51130C4 AM51121C4 AM51131C4 AM51122C4 AM51132C4 AM51123C4 AM51133C4 AM51124C4 AM51134C4 AM51125C4 AM51135C4 AM51126C4 AM51136C4 Contact arrangement SPDT AM51140C4 AM51141C4 AM51142C4 AM51143C4 AM51144C4 AM51145C4 AM51146C4 Contact arrangement SPST-NC SPST-NO AM51150C4 AM51160C4 AM51151C4 AM51161C4 AM51152C4 AM51162C4 AM51153C4 AM51163C4 AM51154C4 AM51164C4 AM51155C4 AM51165C4 AM51156C4 AM51166C4 2) Side COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. 0.98 N {100 gf} 1.08 N {110 gf} 0.59 N {60 gf} 0.29 N {30 gf} 0.59 N {60 gf} 1.08 N {110 gf} 0.59 N {60 gf} Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix "R" for right hand guarded types or "L" for left hand guarded types to the part number. Guardless type Right hand guarded type AM51140C4 AM51140C4R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA 6 x 103 rated 4: UL/CSA 105 rated 3: UL/CSA 6 x 103 rated, VDE and SEMKO approved 31: UL/CSA 105 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. .187 Quick-connect terminal .187 Quick-connect/solder terminal AM51110C4 AM51110A4 4. .250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D. .187 Quick-connect terminal .250 Quick-connect terminal AM51110C4 AM51110D4 4. 16A type (Silver alloy contact) .187 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. 1.96 N {200 gf} *2.94 N {300 gf} 3.92 N {400 gf} 2.16 N {220 gf} *3.14 N {320 gf} 4.12 N {420 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} 0.59 N {60 gf} *0.88 N {90 gf} 1.18 N {120 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} 2.16 N {220 gf} *3.14 N {320 gf} 4.12 N {420 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} Contact arrangement SPDT AM51610C5 AM51610C6 AM51610C7 AM51611C5 AM51611C6 AM51611C7 AM51612C5 AM51612C6 AM51612C7 AM51613C5 AM51613C6 AM51613C7 AM51614C5 AM51614C6 AM51614C7 AM51615C5 AM51615C6 AM51615C7 AM51616C5 AM51616C6 AM51616C7 Contact arrangement SPST-NC SPST-NO AM51620C5 AM51630C5 AM51620C6 AM51630C6 AM51620C7 AM51630C7 AM51621C5 AM51631C5 AM51621C6 AM51631C6 AM51621C7 AM51631C7 AM51622C5 AM51632C5 AM51622C6 AM51632C6 AM51622C7 AM51632C7 AM51623C5 AM51633C5 AM51623C6 AM51633C6 AM51623C7 AM51633C7 AM51624C5 AM51634C5 AM51624C6 AM51634C6 AM51624C7 AM51634C7 AM51625C5 AM51635C5 AM51625C6 AM51635C6 AM51625C7 AM51635C7 AM51626C5 AM51636C5 AM51626C6 AM51636C6 AM51626C7 AM51636C7 57 AM5 2) Side COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. 1.96 N {200 gf} *2.94 N {300 gf} 3.92 N {400 gf} 2.16 N {220 gf} *3.14 N {320 gf} 4.12 N {420 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} 0.59 N {60 gf} *0.88 N {90 gf} 1.18 N {120 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} 2.16 N {220 gf} *3.14 N {320 gf} 4.12 N {420 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} Contact arrangement SPDT AM51640C5 AM51640C6 AM51640C7 AM51641C5 AM51641C6 AM51641C7 AM51642C5 AM51642C6 AM51642C7 AM51643C5 AM51643C6 AM51643C7 AM51644C5 AM51644C6 AM51644C7 AM51645C5 AM51645C6 AM51645C7 AM51646C5 AM51646C6 AM51646C7 Contact arrangement SPST-NC SPST-NO AM51650C5 AM51660C5 AM51650C6 AM51660C6 AM51650C7 AM51660C7 AM51651C5 AM51661C5 AM51651C6 AM51661C6 AM51651C7 AM51661C7 AM51652C5 AM51662C5 AM51652C6 AM51662C6 AM51652C7 AM51662C7 AM51653C5 AM51663C5 AM51653C6 AM51663C6 AM51653C7 AM51663C7 AM51654C5 AM51664C5 AM51654C6 AM51664C6 AM51654C7 AM51664C7 AM51655C5 AM51665C5 AM51655C6 AM51665C6 AM51655C7 AM51665C7 AM51656C5 AM51666C5 AM51656C6 AM51666C6 AM51656C7 AM51666C7 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix "R" for right hand guarded types or "L" for left hand guarded types to the part number. Guardless type Right hand guarded type AM51640C5 AM51640C5R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA 6 x 103 rated 4: UL/CSA 105 rated 3: UL/CSA 6 x 103 rated, VDE and SEMKO approved 31: UL/CSA 105 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also .187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. .187 Quick-connect terminal .187 Quick-connect/solder terminal AM51610C5 AM51610A5 4. * is a custom ordered product. Please consult us. 5. .250 Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D. .187 Quick-connect terminal .250 Quick-connect terminal AM51610C5 AM51610D5 5. 21A type (Silver alloy contact) .250 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever 58 Operating force, Max. *2.94 N {300 gf} 3.92 N {400 gf} *3.14 N {320 gf} 4.12 N {420 gf} *1.77 N {180 gf} 2.35 N {240 gf} *0.88 N {90 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} *3.14 N {320 gf} 4.12 N {420 gf} *1.77 N {180 gf} 2.35 N {240 gf} Contact arrangement SPDT AM52110D6 AM52110D7 AM52111D6 AM52111D7 AM52112D6 AM52112D7 AM52113D6 AM52113D7 AM52114D6 AM52114D7 AM52115D6 AM52115D7 AM52116D6 AM52116D7 Contact arrangement SPST-NC SPST-NO AM52120D6 AM52130D6 AM52120D7 AM52130D7 AM52121D6 AM52131D6 AM52121D7 AM52131D7 AM52122D6 AM52132D6 AM52122D7 AM52132D7 AM52123D6 AM52133D6 AM52123D7 AM52133D7 AM52124D6 AM52134D6 AM52124D7 AM52134D7 AM52125D6 AM52135D6 AM52125D7 AM52135D7 AM52126D6 AM52136D6 AM52126D7 AM52136D7 AM5 2) Side COM terminal Actuator Operating force, Max. *2.94 N {300 gf} 3.92 N {400 gf} *3.14 N {320 gf} 4.12 N {420 gf} *1.77 N {180 gf} 2.35 N {240 gf} *0.88 N {90 gf} 1.18 N {120 gf} *1.77 N {180 gf} 2.35 N {240 gf} *3.14 N {320 gf} 4.12 N {420 gf} *1.77 N {180 gf} 2.35 N {240 gf} Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Contact arrangement SPDT AM52140D6 AM52140D7 AM52141D6 AM52141D7 AM52142D6 AM52142D7 AM52143D6 AM52143D7 AM52144D6 AM52144D7 AM52145D6 AM52145D7 AM52146D6 AM52146D7 Contact arrangement SPST-NC SPST-NO AM52150D6 AM52160D6 AM52150D7 AM52160D7 AM52151D6 AM52161D6 AM52151D7 AM52161D7 AM52152D6 AM52162D6 AM52152D7 AM52162D7 AM52153D6 AM52163D6 AM52153D7 AM52163D7 AM52154D6 AM52164D6 AM52154D7 AM52164D7 AM52155D6 AM52165D6 AM52155D7 AM52165D7 AM52156D6 AM52166D6 AM52156D7 AM52166D7 Remarks: 1. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA 6 x 103 rated 4: UL/CSA 105 rated 3: UL/CSA 6 x 103 rated, VDE and SEMKO approved 31: UL/CSA 105 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 2. * is a custom ordered product. Please consult us. SPECIFICATIONS 1. Contact rating Type Gold clad contact Voltage 0.1A type 6A type 11A type Silver alloy contact 16A type 21A type Gold clad contact for low level circuit 250V AC 125V AC 30V DC 250V AC 125V AC 125V DC 250V AC 125V AC 125V DC 250V AC 125V AC 125V DC 250V AC 125V AC 125V DC 6V DC 12V DC 24V DC Resistive load (cos ] 1) 0.1A 0.1A 0.1A 6A 6A 0.5A 11A 11A 0.6A 16A 16A 0.6A 21A 21A 0.6A 5mA 2mA 1mA Inductive load (cos ] 0.6 to 0.7) 0.1A 0.1A 0.1A 3A 3A 0.5A 6A 6A 0.6A 10A 10A 0.6A 16A 16A 0.6A -- -- -- 59 AM5 2. Characteristics Type 21A type (Silver alloy) 16, 11, 6A type (Silver alloy) 107 operations (at 60 cpm) Mechanical Expected life (min.) Electrical Vibration resistance (by pin plunger) Shock resistance (by pin plunger) (contact opening: max. 1msec.) 105 operations (at rated load) 2 x 106 operations (at low-level circuit rating) 105 Operations (at rated load 20 cpm) 100M (at 500V DC) 1,000Vrms for 1 min. Insulation resistance Between terminals Between terminals Dielectric and other exposed strength metal parts Between terminals and ground Contact resistance (initial) 0.1A type (Gold clad) 2,000Vrms for 1 min. 2,000Vrms for 1 min. 50m (by voltage drop at 0.1A 6 to 8V DC) 50m (by voltage drop at 1A 6 to 8V DC) 10 to 55Hz at simple amplitude of 0.75mm (Contact opening: max. 1msec.) O.F. 0.49 N {50 gf} max. type Min. 98 m/s2 {10 G} O.F. 0.98 N {100 gf} max. type Min. 196 m/s2 {20 G} O.F. 1.96 N {200 gf} to 3.92 N {400 gf} max. type Min. 294 m/s2 {30 G} 0.1 to 1,000mm/sec. (at pin plunger) Min. 294 m/s2 {30 G} Allowable operating speed O.F. 0.15 N {15 gf} to 0.49 N {50 gf} max. type Min. 98 m/s2 {10 G} O.F. 0.98 N {100 gf} max. type Min. 196 m/s2 {20 G} O.F. 1.96 N {200 gf} max. type Min. 294 m/s2 {30 G} O.F. 0.15 N {15 gf}, 0.25 N {25 gf} max. type: 300cpm Other O.F. types: 600cpm -25 to +105C -13 to +221F (Not freezing below 0C 32F) Max. 85% R.H. 6.3g .222oz Maximum operating cycle rate 600cpm Ambient temperature Ambient humidity Weight 3. Operating characteristics Pin plunger 7th digit of part No. Operating force, max. Release force, min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch 1 2 0.15 N {15 gf} 0.25 N {25 gf} 0.029 N {3 gf} 0.059 N {6 gf} 1.6 .063 0.8 .031 0.8 .031 14.70.6 .579.024 3 0.49 N {50 gf} 0.12 N {12 gf} 4 0.98 N {100 gf} 0.25 N {25 gf} 5 6 1.96 N {200 gf} 2.94 N {300 gf} 0.49 N {50 gf} 0.74 N {75 gf} 1.4 .055 0.4 .016 1.0 .039 14.70.4 .579.016 7 3.92 N {400 gf} 0.98 N {100 gf} Short hinge lever 7th digit of part No. Operating force, max. Release force, min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch 3 0.59 N {60 gf} 0.098 N {10 gf} 4 1.08 N {110 gf} 0.20 N {20 gf} 5 2.16 N {220 gf} 0.39 N {40 gf} 1.6 .063 0.5 .020 0.9 .035 15.30.5 .602.020 6 3.14 N {320 gf} 0.59 N {60 gf} 7 4.12 N {420 gf} 0.78 N {80 gf} 3 0.29 N {30 gf} 0.049 N {5 gf} 4 0.59 N {60 gf} 0.098 N {10 gf} 5 1.18 N {120 gf} 0.20 N {20 gf} 3.2 .126 1.0 .039 1.4 .055 15.31.0 .602.039 6 1.77 N {180 gf} 0.29 N {30 gf} 7 2.35 N {240 gf} 0.39 N {40 gf} 3 0.15 N {15 gf} 0.025 N {2.5 gf} 4 0.29 N {30 gf} 0.049 N {5 gf} 5 0.59 N {60 gf} 0.098 N {10 gf} 7.5 .295 2.0 .079 2.2 .087 15.32.6 .602.102 6 0.88 N {90 gf} 0.15 N {15 gf} 7 1.18 N {120 gf} 0.20 N {20 gf} Hinge lever 7th digit of part No. Operating force, max. Release force, min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch Long hinge lever 7th digit of part No. Operating force, max. Release force, min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch 60 AM5 Simulated roller lever 7th digit of part No. Operating force, max. Release force, min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch 3 0.29 N {30 gf} 0.049 N {5 gf} 4 0.59 N {60 gf} 0.098 N {10 gf} 5 1.18 N {120 gf} 0.20 N {20 gf} 3.2 .126 1.0 .039 1.4 .055 18.51.0 .728.039 6 1.77 N {180 gf} 0.29 N {30 gf} 7 2.35 N {240 gf} 0.39 N {40 gf} 3 0.59 N {60 gf} 0.098 N {10 gf} 4 1.08 N {110 gf} 0.20 N {20 gf} 5 2.16 N {220 gf} 0.39 N {40 gf} 1.6 .063 0.5 .020 0.9 .035 20.70.5 .815.020 6 3.14 N {320 gf} 0.59 N {60 gf} 7 4.12 N {420 gf} 0.78 N {80 gf} 3 0.29 N {30 gf} 0.049 N {5 gf} 4 0.59 N {60 gf} 0.098 N {10 gf} 5 1.18 N {120 gf} 0.20 N {20 gf} 3.2 .126 1.0 .039 1.4 .055 20.71.0 .815.039 6 1.77 N {180 gf} 0.29 N {30 gf} 7 2.35 N {240 gf} 0.39 N {40 gf} Short roller lever 7th digit of part No. Operating force, max. Release force, min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch Roller lever 7th digit of part No. Operating force, max. Release force, min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch mm inch General tolerance: 0.25 .010 DIMENSIONS 1. Pin plunger Bottom COM terminal (Guardless) .187 Quick-connect terminal .250 Quick-connect terminal 1.55 dia. .061 1.65 +0.1 dia. 0 .065 +.004 dia. 0 6.35 +0.05 -0.07 +.002 .250 -.003 6.4 .252 0.15 27.8 1.094 20.2 .795 2.8 .110 (O.P.) 14.7 0.4 10.3 0.1 .004 .579 .016 15.9 .626 .406 NC 2 1 NO 3 0.5 .020 4.1 .161 9.3 .366 Side COM terminal (Guardless) 5.65 .222 6.5 .256 (P.T.) 1.4 max. .055 3.4 0.15 13.5 .134 .006 .531 22.2 0.1 .004 .874 39.45 1.553 27.8 1.094 20.2 .795 2.8 .110 (O.P.) 14.7 0.4 10.3 0.1 .004 .579 .016 15.9 .626 .406 6.65 .262 C 2.8 .110 3.1 +0.25 -0.05 +.010 .122 -.002 3.95 .156 4.15 .163 .006 8.05 +0.1 -0.05 +.004 .317 -.002 3.1 +0.25 -0.05 dia. 2.8 .122 +.010 -.002 dia. .110 4.1 3.6 .161 .142 2 .079 1.8 .071 NC 3 C 2.8 .110 3.1 +0.25 -0.05 .122 +.010 -.002 10.3 .406 .187 Quick-connect terminal 3.4 0.15 .134 .006 22.2 0.1 .874 .00442.7 1.681 NO 9.7 .382 10.3 .406 .250 Quick-connect terminal 1.55 dia. .061 1.65 +0.1 dia. 0 .065 +.004 dia. 0 6.4 .252 (P.T.) 1.4 max. .055 4.75 3.2 .187 .126 6.35 1.8 .250 .071 3.1 +0.25 -0.05 dia. 2.8 .110 .122 +.010 -.002 dia. 27.8 1.094 20.2 .795 2.8 .110 (O.P.) 14.7 0.4 10.3 0.1 .004 .579 .016 15.9 .626 .406 NC 2 1 3 C 2.8 .110 +0.25 3.1 -0.05 .122 +.010 -.002 3.4 0.15 .134 .006 22.2 0.1 .874 .004 39.45 1.553 NO 0.5 .020 4.1 .161 9.3 .366 3.95 .156 9.3 10.6 0.8 .366 .417 .031 2 1 12 1 (P.T.) 1.4 max. .055 4.75 3.2 .187 .126 6.35 1.8 .250 .071 2.8 3.1 +0.25 -0.05 dia. .110 .122 +.010 -.002 dia. 3.95 .156 5.65 .222 6.5 .256 6 .236 (P.T.) 1.4 max. .055 2 .079 1.8 .071 27.8 1.094 20.2 .795 2.8 .110 (O.P.) 14.7 0.4 10.3 0.1 .004 .579 .016 15.9 .626 .406 8.05 +0.1 -0.05 .317 +.004 -.002 2.8 .110 NC 2 1 3 NO +0.05 6.35 -0.07 .250 +.002 -.003 4.15 0.15 .163 .006 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 4.1 3.6 .161 .142 3.95 .156 9.3 10.6 0.8 .366 .417 .031 C 10.3 .406 2.8 .110 3.1 +0.25 -0.05 +.010 .122 -.002 3.4 0.15 .134 .006 22.2 0.1 .874 .004 42.7 1.681 9.8 .386 10.3 .406 61 AM5 mm inch General tolerance: 0.25 .010 Side COM terminal (Right hand guarded) .187 Quick-connect terminal 1.55 dia. .061 6.4 .252 (P.T.) 1.4 max. .055 3.2 .126 6.35 1.8 .250 .071 2.8 .110 27.8 1.094 20.2 .795 2.8 .110 (O.P.) 14.7 0.4 10.3 0.1 .004 .579 .016 15.9 .626 .406 4.75 .187 NC 3 4.1 .161 9.3 .366 0.5 .020 2 1 NO C 2.8 .110 3.1 +0.25 -0.05 .122 +.010 -.002 Side COM terminal (Left hand guarded) 3.95 .156 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 0.15 3.4 .006 .134 22.2 0.1 .874 .004 39.45 1.553 41 1.614 5.65 .222 6.5 20 .256 .787 6 .236 0.5 .020 1.0 .039 10.3 .406 .187 Quick-connect terminal 6.35 .250 4.75 .187 3.2 .126 6.4 .252 1.55 dia. .061 1.8 .071 3.95 .156 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 5.65 4.1 .222 .161 6.5 9.3 0.5 20 .256 .366 .020 .787 6 .236 0.5 .020 1.0 .039 (P.T.) 1.4 max. .055 27.8 1.094 20.2 .795 2.8 .110 2.8 .110 (O.P.) 0.4 10.3 0.1 15.9 14.7 .016 .406 .004 .626 .579 3.4 0.15 .134 .006 22.2 0.1 .874 .004 39.45 1.553 41 1.614 10.3 .406 2.8 .110 3.1 +0.25 -0.05 +.010 .122 -.002 Pin plunger characteristic chart v v -- -- -- -- -- -- -- -- 1 2 0.15 N {15 gf} 0.25 N {25 gf} 0.029 N {3 gf} 0.059 N {6 gf} 1.6 .063 0.8 .031 0.8 .031 14.70.6 .579.024 0.1A type 6A type 11A type 16A type 21A type 7th digit of part No. Operating force, max. Release force, min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch v v -- -- -- 3 0.49 N {50 gf} 0.12 N {12 gf} v v v -- -- 4 0.98 N {100 gf} 0.25 N {25 gf} v -- v v -- -- v v -- v 5 6 1.96 N {200 gf} 2.94 N {300 gf} 0.49 N {50 gf} 0.74 N {75 gf} 1.4 .055 0.4 .016 1.0 .039 14.70.4 .579.016 -- v -- v v 7 3.92 N {400 gf} 0.98 N {100 gf} 2. Short hinge lever 1.55 dia. .061 6.4 .252 4.75 .187 3.2 .126 0.5 22.1 .870 .020 27.8 1.094 20.2 .795 (P.T.) 1.6 max. .063 (O.P.) 15.3 0.5 10.3 0.1 .004 .602 .020 15.9 .626 .406 1.8 .071 2.8 .110 NC 2 1 3 NO 3.4 0.15 .134 .006 22.2 0.1 .874 .004 39.45 1.553 The dimensions other than drawn above are same as pin plunger type. 62 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 0.5 .020 4.1 .161 9.3 .366 5.0 .197 5.65 .222 6.5 .256 6.65 .262 C 2.8 .110 3.1 +0.25 -0.05 +.010 .122 -.002 6.35 .250 13.5 .531 10.3 .406 0.1A type 6A type 11A type 16A type 21A type 7th digit of part No. Operating force, Max. Release force, Min. Pretravel, max. mm inch Movement differential, max. mm inch Overtravel, min. mm inch Operating position mm inch v v -- -- -- 3 0.59 N {60 gf} 0.098 N {10 gf} v v v -- -- 4 1.08 N {110 gf} 0.20 N {20 gf} v v -- v -- 5 2.16 N {220 gf} 0.39 N {40 gf} -- v -- v v 6 3.14 N {320 gf} 0.59 N {60 gf} 1.6 .063 0.5 .020 0.9 .035 15.30.5 .602.020 -- v -- v v 7 4.12 N {420 gf} 0.78 N {80 gf} AM5 mm inch General tolerance: 0.25 .010 3. Hinge lever 1.55 dia. .061 6.4 .252 4.75 .187 3.2 .126 6.35 .250 0.5 35.8 1.409 .020 27.8 1.094 20.2 .795 (P.T.) 3.2 max. .126 (O.P.) 14.3 1.0 15.9 10.3 0.1 .602 .039 .626 .406 .004 1.8 .071 2.8 .110 NC 0.5 .020 2 1 NO 3 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 4.1 .161 9.3 .366 5.65 .222 6.5 .256 6.65 .262 C 2.8 .110 3.1 +0.25 -0.05 +.010 .122 -.002 5.0 .197 0.15 3.4 .134 .006 22.2 0.1 .874 .004 39.45 1.553 13.5 .531 10.3 .406 0.1A type v v v -- -- 6A type v v v v v 11A type -- v -- -- -- 16A type -- -- v v v 21A type -- -- -- v v 7th digit of part No. 3 4 5 6 7 Operating force, 0.29 N 0.59 N 1.18 N 1.77 N 2.35 N Max. {30 gf} {60 gf} {120 gf} {180 gf} {240 gf} Release force, 0.049 N 0.098 N 0.20 N 0.29 N 0.39 N Min. {5 gf} {10 gf} {20 gf} {30 gf} {40 gf} Pretravel, 3.2 .126 max. mm inch Movement differential, 1.0 .039 max. mm inch Overtravel, 1.4 .055 min. mm inch Operating position mm 15.31.0 .602.039 inch The dimensions other than drawn above are same as pin plunger type. 4. Long hinge lever 1.55 dia. .061 6.4 .252 6.35 .250 59.5 0.5 2.343 .020 1.8 .071 2.8 .110 27.8 1.094 20.2 .795 (O.P.) 15.3 2.6 .602 .102 4.75 .187 3.2 .126 (P.T.) 7.5 max. .295 +0.25 15.9 10.3 0.1 3.1 -0.05 .626 .406 .004 .122 +.010 -.002 NC 0.5 .020 2 1 NO 3 5.0 .197 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 4.1 .161 9.3 .366 6.65 .262 C 0.15 2.8 .110 3.4 .134 .006 22.2 0.1 .874 .004 39.45 1.553 5.65 .222 6.5 .256 13.5 .531 10.3 .406 0.1A type v v v -- -- 6A type v v v v v 11A type -- v -- -- -- 16A type -- -- v v v 21A type -- -- -- v v 7th digit of part No. 3 4 5 6 7 Operating force, 0.15 N 0.29 N 0.59 N 0.88 N 1.18 N Max. {15 gf} {30 gf} {60 gf} {90 gf} {120 gf} Release force, 0.025 N 0.049 N 0.098 N 0.15 N 0.20 N Min. {2.5 gf} {5 gf} {10 gf} {15 gf} {20 gf} Pretravel, 7.5 .295 max. mm inch Movement differential, 2.0 .079 max. mm inch Overtravel, 2.2 .087 min. mm inch Operating position mm 15.32.6 .602.102 inch The dimensions other than drawn above are same as pin plunger type. 5. Simulated roller lever 1.55 dia. .061 6.4 .252 4.75 .187 3.2 .126 (P.T.) 3.2 max. .126 R3 18 .1 6.35 .250 32.8 0.5 1.291 .020 27.8 1.094 20.2 .795 (O.P.) 18.5 1.0 .728 .039 15.9 10.3 0.1 .004 .626 .406 1.8 .071 2.8 .110 NC 2 1 3 NO 3.1 +0.25 -0.05 .122 +.010 -.002 3.4 0.15 .134 .006 22.2 0.1 .874 .004 39.45 1.553 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 4.1 .161 9.3 .366 5.65 .222 6.5 .256 6.65 .262 C 2.8 .110 0.5 .020 5.0 .197 13.5 .531 10.3 .406 0.1A type v v v -- -- 6A type v v v v v 11A type -- v -- -- -- 16A type -- -- v v v 21A type -- -- -- v v 7th digit of part No. 3 4 5 6 7 0.29 N 0.59 N 1.18 N 1.77 N 2.35 N Operating force, {30 gf} {60 gf} {120 gf} {180 gf} {240 gf} Max. Release force, 0.049 N 0.098 N 0.20 N 0.29 N 0.39 N Min. {5 gf} {10 gf} {20 gf} {30 gf} {40 gf} Pretravel, 3.2 .126 max. mm inch Movement differential, 1.0 .039 max. mm inch Overtravel, 1.4 .055 min. mm inch Operating position mm 18.51.0 .728.039 inch The dimensions other than drawn above are same as pin plunger type. 63 AM5 mm inch General tolerance: 0.25 .010 6. Short roller lever 1.55 dia. .061 6.4 .252 (O.P.) 20.7 0.5 .815 .020 4.75 3.2 .187 .126 1.8 6.35 .071 .250 20.6 0.5 .811 .020 27.8 1.094 20.2 .795 (P.T.) 1.6 max. .063 15.9 10.3 0.1 .626 .406 .004 2.8 .110 NC NO 3 4.1 .161 9.3 .366 3.4 0.15 .134 .006 22.2 0.1 .874 .004 39.45 1.553 5.65 .222 6.5 .256 6.65 .262 C 2.8 .110 +0.25 3.1 -0.05 .122 +.010 -.002 4.8 .189 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 0.5 .020 2 1 4.9 .193 13.5 .531 10.3 .406 The dimensions other than drawn above are same as pin plunger type. 7. Hinge Roller lever 1.55 dia. .061 6.4 .252 (P.T.) 3.2 max. .126 3.2 .126 34.2 0.5 1.346 .020 1.8 .071 27.8 1.094 20.2 .795 (O.P.) 20.7 1.0 .815 .039 15.9 10.3 0.1 .626 .406 .004 2.8 .110 NC 2 1 3 NO 3.4 0.15 .134 .006 22.2 0.1 .874 .004 39.45 1.553 4.9 .193 4.8 .189 3.1 +0.25 -0.05 dia. .122 +.010 -.002 dia. 0.5 .020 4.1 .161 9.3 .366 5.65 .222 6.5 .256 6.65 .262 C 2.8 .110 3.1 +0.25 -0.05 +.010 .122 -.002 4.75 .187 6.35 .250 13.5 .531 10.3 .406 The dimensions other than drawn above are same as pin plunger type. NOTES 1. Fastening of the switch body 1) Use flat filister head M3 screws to mount switches with less than a 5kg-cm torque. Use of screws washers or adhesive lock is recommended to prevent loosening of the screws. 2) Check insulation distance between ground and each terminal. 3) When the operation object is in the free position, force should not be applied directly to the actuator or pin plunger. Also force should be applied to the pin plunger from vertical direction to the switch. 4) The standard value of overtravel should be the range of 70% to 100% of the rated O.T. value. 2. Soldering operations Soldering should be accomplished in less than 5 seconds, with a 60 watt iron. Care should be taken not to apply force to the terminal during soldering. 3. Varience of operating characteristics When specifying the switch, allow +20% to the listed operating and release forces. 4. Environment Avoid using the switches in the following conditions; 64 0.1A type v v v -- -- 6A type v v v v v 11A type -- v -- -- -- 16A type -- -- v v v 21A type -- -- -- v v 7th digit of part No. 3 4 5 6 7 0.59 N 1.08 N 2.16 N 3.14 N 4.12 N Operating force, {60 gf} {110 gf} {220 gf} {320 gf} {420 gf} Max. 0.098 N 0.20 N 0.39 N 0.59 N 0.78 N Release force, {10 gf} {20 gf} {40 gf} {60 gf} {80 gf} Min. Pretravel, 1.6 .063 max. mm inch Movement differential, 0.5 .020 max. mm inch Overtravel, 0.9 .035 min. mm inch Operating position mm 20.70.5 .815.020 inch 0.1A type v v v -- -- 6A type v v v v v 11A type -- v -- -- -- 16A type -- -- v v v 21A type -- -- -- v v 7th digit of part No. 3 4 5 6 7 0.29 N 0.59 N 1.18 N 1.77 N 2.35 N Operating force, Max. {30 gf} {60 gf} {120 gf} {180 gf} {240 gf} 0.049 N 0.098 N 0.20 N 0.29 N 0.39 N Release force, {5 gf} {10 gf} {20 gf} {30 gf} {40 gf} Min. Pretravel, 3.2 .126 max. mm inch Movement differential, 1.0 .039 max. mm inch Overtravel, 1.4 .055 min. mm inch Operating position mm 20.71.0 .815.039 inch USE OF CONNECTOR * In corrosive gases, such as silicon gas * In a dusty environment 5. For switching of inductive loads (relays, solenoids, etc.) 1) In order to prevent damage to contacts due to the occurrence of arcing, an arc absorbing circuit should be applied. 2) Care should be taken that occurrence in AC load possibly shorten the expected life. 6. Please assure the quality and reliability of the switch under the actual service condition. 7. Wire lever and other light actuators are suitable for the types of O.F. 0.15 N {15 gf} and 0.25 N {25gf} (pin plunger) Select the actuator with consideration of applied shock around mounting place and mounting direction. 8. It is recommended to use Gold clad contact type in use of low-level circuit rating. 9. Cover and body are press-fitted. Once it is taken apart, it may cause change of characteristics. The .187 Quick-connect terminal and .250 Quick-connect terminal accept the all kinds of 1 polarity connectors and the "Positive Lock" connectors (AMP Co., Ltd.) Please contact the manufacturers directly. * receptacle terminal .250 series .187 series * "Positive Lock" connector AMP Co., Ltd. (equipped with the lock construction of low insertion type) .187 type (1 polarity) .187 type (2 polarities) .250 type (1 polarity) .187 type (3 polarities) MINIATURE SWITCHES WITH HIGH PRECISION (Contact gap: more than 1mm .039inch type) QV (AM5) SWITCHES * Conforms with the IEC950 standards for secondary circuit insulation distance. Assures a contact gap of at least 1mm .039inch * Can handle high-capacity loads on the secondary side that S-type size switches cannot * High inrush and hard impacts resistant * Excellent operating position precision * UL/CSA/VDE/SEMKO approved PRODUCT TYPES Contact rating: 0.1A, 6A, 11A, 16A (250V AC) Terminal shape: .187 Quick connect terminal, .187 Quick connect/solder terminal For other specifications, please consult us. DIMENSIONS AND NOTES Please refer to Standard QV switches catalog for dimensions and notes. SPECIFICATIONS * Contact ratings (0.1 to 16 A) Resistive load (cos = 1.0) Voltage Inductive load (cos ] 0.6 to 0.7) Type 0.1A 6A 11A 16A 0.1A 6A 11A 16A 250V AC 0.1A 6A 11A 16A 0.1A 3A 6A 10A 125V AC 0.1A 6A 11A 16A 0.1A 3A 6A 10A 125V DC 0.1A 0.5A 0.6A 0.6A 0.1A 0.5A 0.6A 0.6A * Low-level circuit type DC 6V 5mA (Resistive load) DC 12V 2mA (Resistive load) DC 24V 1mA (Resistive load) Remark: The inductive load for DC should have a time constant of 7 ms or less. Please consult us for further information. 65