Military Version (Continued)
DC Electrical Characteristics
VEE eb
4.2V to b5.7V, VCC eVCCA eGND, TCeb
55§Ctoa
125§C (Note 3) (Continued)
Symbol Parameter Min Typ Max Units TCConditions Notes
VOHC Output HIGH b1035 mV 0§Cto
or VIL (Min)
VIN eVIH (Max) Loading with
50Xto b2.0V
Voltage a125§C
b1085 mV b55§C1, 2, 3
VOLC Output LOW b1610 mV 0§Cto
Voltage a125§C
b1555 mV b55§C
VBB Output Reference b1260 mV 0§Cto I
VBB e0mA, VEE e4.2V 1,2,3
Voltage a125§C
b1380 b1260 mV 0§Cto I
VBB eb
250 mA, VEE eb
5.7V
a125§C 1,2,3
b
1396 mV b55§CI
VBB eb
350 mA, VEE eb
5.7V
VDIFF Input Voltage 150 mV b55§Cto Required for Full Output Swing 1, 2, 3
Differential a125§C
VCM Common Mode VCC b2.0 VCC b0.5 V b55§Cto 1, 2, 3
Voltage a125§C
VIH Single-Ended b1165 b870 mV b55§C to Guaranteed HIGH Signal for All 1, 2, 3, 4
Input High Voltage a125§C Inputs (with Dntied to VBB)
VIL Single-Ended b1830 b1475 mV b55§C to Guaranteed LOW Signal for All 1, 2, 3, 4
Input Low Voltage a125§C Inputs (with Dntied to VBB)
IIH Input HIGH Current 50 mA0§Cto V
IN eVIH (Max),D
a
–DeeVBB,
a125§CDa–DeeVIL (Min) 1, 2, 3
70 mAb55§C
ICBO Input Leakage b10 mAb55§Cto V
IN eVEE,D
a
–DeeVBB,1, 2, 3
Current a125§CD
a
–DeeVIL (Min)
IEE Power Supply b65 b25 mA b55§Cto D
a
–DeeVBB,1, 2, 3
Current a125§CD
a
–DeeVIL (Min)
Note 1: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals b55§C), then testing
immediately without allowing for the junction temperature to stabilize due to heat dissipation after power-up. This provides ‘‘cold start’’ specs which can be
considered a worst case condition at cold temperatures.
Note 2: Screen tested 100% on each device at b55§C, a25§C, and a125§C, Subgroups 1, 2, 3, 7, and 8.
Note 3: Sample tested (Method 5005, Table I) on each manufactured lot at b55§C, a25§C, and a125§C, Subgroups A1, 2, 3, 7, and 8.
Note 4: Guaranteed by applying specified input condition and testing VOH/VOL.
AC Electrical Characteristics
VEE eb
4.2V to b5.7V, VCC eVCCA eGND
Symbol Parameter TCeb
55§CT
C
ea
25§CT
C
ea
125§CUnits Conditions Notes
Min Max Min Max Min Max
tPLH Propagation Delay 0.40 2.30 0.60 2.20 0.60 2.70 ns 1, 2, 3
tPHL Data to Output
Figures 1
and
2
tTLH Transition Time 0.20 1.40 0.20 1.40 0.20 1.40 ns 4
tTHL 20% to 80%, 80% to 20%
Note 1: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals b55§C), then testing
immediately after power-up. This provides ‘‘cold start’’ specs which can be considered a worst case condition at cold temperatures.
Note 2: Screen tested 100% on each device at a25§C temperature only, Subgroup A9.
Note 3: Sample tested (Method 5005, Table I) on each manufactured lot at a25§C, Subgroup A9, and at a125§C and b55§C temperatures, Subgroups A10 and
A11.
Note 4: Not tested at a25§C, a125§C and b55§C temperature (design characterization data).
5