MEDER electronic SIL Series Single-In-Line Reed Relays DESCRIPTION Single-In-Line Reed Relays reduce the required space to a minimum. The SIL series is available as both voltage and current driven (line sense) Reed Relays. Requiring only half the PCB area of the DIP or DIL series, the SIL relays offer all the advantages of Reed Technology. The SIL series is approved according to EN60950 and offers sufficient distance in air and creepage paths. CHARACTERISTICS * * * * FEATURES * NEW Breakdown voltage of 4200 VDC * Magnetic shield available * High resistance version * Other coil resistances available * Form B available Approved according to EN60950 High resistance coils of up to 2000 at 12 VDC Line sense relay with pull-in current = 15 mA Breakdown voltage coil / contact of up to 4.25 kVDC PIN OUT DIMENSIONS All dimensions in mm [inches] Part Number Example ORDER INFORMATION SIL12 - 1A72 - 71L 12 is the nominal voltage 1A is the contact form 72 is the switch model L is the option RELAY NOMINAL CONTACT SWITCH SERIES VOLTAGE FORM MODEL SIL XX - 1X XX - 05, 12, 15, 24* OPTIONS OPTIONS L M D Q = No option = With magnetic shield = With diode and no magnetic shield = With diode and with magnetic shield SIL-CL - A ** HIGH PIN OUT OPTIONS 71 X VERSION 31, 72, 75, 1A 81 NA 1A 81 - XX L, M, D , Q 84 05, 12 RESISTANCE 71 L, M HR M NA * Other coi l resi stances avai lable. Please consult factory. ** Form B avai lable. www.meder.com Germany # ++49-(0)7733-94870, USA # 800-870-5385 305 SIL Series MEDER electronic Single-In-Line Reed Relays RELAY DATA All data at 20 0C Switch Model --> Contact For m --> Contact Ratings Conditions Switch 31 For m A Switch 72 For m A Switch 75 For m A Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Units Switching Power Any DC combination of V & A not to exceed their individual max.'s Switching Voltage 50 20 10 W D C or peak A C 1000 200 1000 V Switching Current D C or peak A C 2.0 1.0 0.5 A Carry Current D C or peak A C 3.0 1.25 1.0 A Static Contact Resistance w/ 0.5V & 50mA 80 150 200 m Dynamic Contact Resistance Measured w/ 0.5V & 50mA 1.5 ms after closure 200 m Insulation Resistance (100 Volts applied) Across contacts Contact to coil 1 0 10 1 0 12 Breakdown Voltage Across contacts Contact to coil 1500 4200 Operate Time, incl. Bounce Measured w/ 100% overdrive 150 200 1 0 12 1 0 12 1 0 13 1 0 10 1 0 12 1 0 13 320 4200 1 0 13 1000* 4200 1.2 VD C 0.5 1.0 0.1 0.5 ms 0.1 ms Reset Time Measured w/ no coil suppression Capacitance Across contacts Contact to coil 0.4 2.0 0.2 2.0 0.4 2.0 pF DC only & <10 pF stray cap. 500 1000 500 106 Cycles Life Expectancies Switching 5 Volts@ 10mA For other load requirements please see our life test section located on page 151. Environmental Data Shock Resistance 1/2 sine wave duration 11ms 50 50 50 g Vibration Resistance From 10 - 2000 Hz 20 20 20 g Ambient Temperature 10 0C/ minute max. allowable -20 70 -20 70 -20 70 0 C Storage Temperature 10 0C/ minute max. allowable -35 95 -35 95 -35 95 0 C Soldering Temperature 5 sec dwell 260 0 C 260 260 * For higher voltage requirements please consult factory. www.meder.com 306 Germany # ++49-(0)7733-94870, USA # 800-870-5385 MEDER electronic SIL Series Single-In-Line Reed Relays RELAY DATA All data at 20 0C Switch Model --> Contact For m --> Contact Ratings Conditions Switch 81 For m A Switch 84 For m A Min. Typ. Max. Min. Typ. Max. Units Switching Power Any DC combination of V & A not to exceed their individual max.'s 5 10 W Switching Voltage D C or peak A C 90 400 V Switching Current D C or peak A C 0.5 0.5 A Carry Current D C or peak A C 1.0 1.0 A Static Contact Resistance w/ 0.5V & 50mA 200 150 m Dynamic Contact Resistance Measured w/ 0.5V & 50mA 1.5 ms after closure 200 200 m Insulation Resistance (100 Volts applied) Across contacts Contact to coil 109 1 0 12 Breakdown Voltage Across contacts Contact to coil 100 4200 Operate Time, incl. Bounce Measured w/ 100% overdrive 0.5 2.0 ms Reset Time Measured w/ no coil suppression 0.1 0.1 ms Capacitance Across contacts Contact to coil 0.4 2.0 0.7 2.0 pF DC only & <10 pF stray cap. 100 200 106 Cycles 1011 1 0 12 1 0 13 1 0 13 700 4200 VD C Life Expectancies Switching 5 Volts@ 10mA For other load requirements please see our life test section located on page 151. Environmental Data Shock Resistance 1/2 sine wave duration 11ms 50 50 g Vibration Resistance From 10 - 2000 Hz 20 20 g Ambient Temperature 10 0C/ minute max. allowable -20 70 -20 70 0 C Storage Temperature 10 0C/ minute max. allowable -35 95 -35 95 0 C Soldering Temperature 5 sec dwell 260 0 C 260 www.meder.com Germany # ++49-(0)7733-94870, USA # 800-870-5385 307 SIL Series MEDER electronic Single-In-Line Reed Relays COIL DATA CONTACT FOR M SWITCH MODEL All data at 20 0C * 31 1A 72 75 84 81 COIL VOLTAGE COIL RESISTANCE PULL-IN VOLTAGE DROP-OUT VOLTAGE NOMINAL COIL POWER VD C VD C VD C mW Nom. Max. Min. Typ. Max. Min. Max. Min. Max. Typ. 5 7.5 72 80 88 0.76 3.5 0.75 3.4 310 12 16 290 320 350 1.9 8.4 1.8 8.3 450 24 30 1170 1300 1430 3.7 16.8 3.6 16.7 440 5 7.5 450 (180)** 500 (200) 550 (220) 0.76 3.5 0.75 3.4 50 (125) 12 16 900 1000 1100 1.9 8.4 1.8 8.3 145 15 7.5 1800 2000 2200 2.3 10.5 2.2 10.4 110 24 30 1800 2000 2200 3.7 16.8 3.6 16.7 290 5 HR 7.5 900 1000 1100 0.76 3.5 .75 3.4 25 12 HR 16 1800 2000 2200 1.9 8.4 1.8 8.3 70 **Data in () are valid for switch model 31, 75, and 84 * The pull-in / drop-out voltages and coil resistance will change at the rate of 0.4% per 0C. SIL-CL LINE SENSE RELAY COIL DATA CONTACT FOR M SWITCH MODEL All data at 20 0C * 1A 81 COIL RESISTANCE PULL-IN CUR RENT DROP-OUT CUR RENT INDUCTANCE AT 1 kHz mA mA mH Min. Typ. Max. Min. Max. Min. Max. Min. Typ. Max. 13.5 15 18 5.1 15 5 14.9 2.76 3.45 4.14 * The pull-in / drop-out currents and coil resistance will change at the rate of 0.4% per 0C. www.meder.com 308 Germany # ++49-(0)7733-94870, USA # 800-870-5385