745 FIBER SENSORS Head-separated Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES DPH-100 SERIES Related Information General terms and conditions.............. F-3 Glossary of terms......................... P.1563~ Selection guide.............................. P.699~ General precautions....................... P.1566 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS panasonic.net/id/pidsx/global Digital Thin body controller can do cascade connection and communication with upper devices Works like a fiber sensor DPS-400 series accommodates to the requirements for pressure sensors at production site such as miniaturization of sensors for downsizing equipment, convenient shape to fit into machines, and reduction of man-hours when it comes to replacement. MACHINE VISION SYSTEMS Sensor head DPH-100 series Controller DPS-400 series UV CURING SYSTEMS Direct installation using a hexagonal wrench Thin body (t 10 mm t 0.394 in) and multi-unit connection on a DIN rail helps to downsize equipment for better construction. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Direct mounting from above Installation in narrow spaces Extended freedom of layout Single axis type free turning structure Flow Install on a DIN rail DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 Current value and threshold value can be checked simultaneously on the dual display The controller is equipped with a 4-digit dual digital display. Because the threshold value can be adjusted while checking the "current value (current pressure value)", direct setting and checking of the "threshold value" is made smoothly without having to switch screen modes. Dual display + Direct setting Because direct setting is possible Operation is as easy as analog Thickness 10 mm 0.394 in Threshold value Current value "The current value" and "the threshold value" can be checked simultaneously! Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES Wire-saving, space-saving FIBER SENSORS The quick-connection cables enable reductions in wiring. The connections and man-hours for the relay terminal block setup can be reduced and valuable space is saved. Also, DPS-400 series can be connected side-by-side with fiber sensors FX-300 series or laser sensors LS-400 series. Wire-saving in power supply DPS-400 series Fiber sensor FX-300 series 746 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS DPS-400 series Up to 16 sensors allowed in optical communication / setting copying SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Power supply cable Wire-saving in power supply* DPS-400, FX-300, LS-400, etc. SIMPLE WIRE-SAVING UNITS Up to 16 sensors can be connected togetther WIRE-SAVING SYSTEMS Output line 1 Output line 2 Output line 2' Output line 3 Main cable CN-74-C Output line 3' Output line 16 MEASUREMENT SENSORS Output line 16' Sub cable CN-72-C Only output lines are used, so that wiring can be greatly reduced and space saving can be obtained. * Check the instruction manual of each model for the arrangement order and such when connecting, as communication varies depending on the model. Optical communication / setting copying STATIC CONTROL DEVICES LASER MARKERS PLC Network communication Ultra high-speed response time at 150 s Can connect to Open Network CC-Link IE Field / CC-Link / DeviceNet / EtherCAT via Communication Unit for Open Network SC-GU3 series. Monitoring and various settings can be done from PLC, PC, etc. Ultra high-speed response time contributes to even greater productivity. Response time at 150 s Independent dual outputs and five output modes equipped The sensor is equipped with two independent comparative outputs in which separate sensing modes can be selected. Current values of connected sensors are shown. 1ch 90 65 EASY mode This mode is used for comparative output ON/OFF control. 9ch Hysteresis mode 0 0 2ch 50 0 10ch 0 0 3ch 40 70 11ch 0 0 4ch 0 0 12ch 0 0 5ch 0 0 13ch 0 0 6ch 0 0 14ch 0 0 7ch 0 0 15ch 0 0 8ch 0 0 16ch 0 0 End unit Window comparator mode This mode is used for setting comparative output ON or OFF at pressures within the setting range. [Touch panel display example] Threshold values of connected sensors are shown. Communication Unit for Open Network SC-GU3 series This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON/OFF control. Forced output ON mode Digital pressure sensor DPS-401/402 Digital fiber sensor FX-501/502 Digital fiber sensor FX-301/305 Digital laser sensor LS-403/502 *CC-Link and CC-Link IE Field are a registered trademark of Mitsubishi Electric Corporation. DeviceNet is a registered trademark of ODVA (Open DeviceNet Vender Association, Inc.). EtherCAT is a registered trademark of Beckhoff Automation GmbH. *Refer to p.971~ for SC-GU3 series. The comparative outputs are forcibly maintained at ON irrespective of the set values. Forced output OFF mode The comparative outputs are forcibly maintained at OFF irrespective of the set values. HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 747 FIBER SENSORS LASER SENSORS Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES Hexagonal wrench installation saves man-hours and spaces Using a hexagonal wrench, obstructions can be avoided and installation can be done easily by turning the bolt from above. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Previous problem Spanner is difficult to hold! AREA SENSORS (Obstructed by floor surface) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS DPH-100 Turns minimally from above! PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Previous problem WIRE-SAVING SYSTEMS Previous problem MEASUREMENT SENSORS Obstac le Large space needed to turn the spanner! STATIC CONTROL DEVICES LASER MARKERS Spanner cannot be turned! PLC HUMAN MACHINE INTERFACES Quick maintenance Mounting shape at 14 mm 0.551 in ENERGY MANAGEMENT SOLUTIONS During maintenance, the sensor head needed to be removed can be easily removed from directly above. Because the dead zone caused by the nut is eliminated, the narrowed-down thickness after installation contributes to space saving. FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS DPH-100 Remove and install the required sensor head directly. Previous models 14 mm 0.551 in Wasted space Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 DPH-10-M3 DPH-10-M5 Saved space 12.5 mm 0.492 in 75 mm 2.953 in Previous models DPH-100 10 mm 0.394 in 60 mm 2.362 in 20 % DOWN from previous models Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES ORDER GUIDE 748 FIBER SENSORS LASER SENSORS Controllers Model No. Applicable sensor head For compound pressure / vacuum pressure DPS-401 DPH-101 DPH-103 For positive pressure DPS-402 DPH-102 Type Appearance Quick-connection cables Type Connection method Output NPN open-collector transistor two outputs Use optional quick-connection cable (4-core) Model No. CN-74-C1 CN-74-C2 CN-74-C5 CN-72-C1 CN-72-C2 CN-72-C5 Main cable (4-core) Sub cable (2-core) Length: 2 m 6.562 ft Length: 5 m 16.404 ft Length: 1 m 3.281 ft Length: 2 m 6.562 ft Length: 5 m 16.404 ft 2 0.2 mm 4-core cabtyre cable, with connector on one end Cable outer diameter: o3.3 mm o0.130 in 0.2 mm2 2-core cabtyre cable, with connector on one end Cable outer diameter: o3.3 mm o0.130 in End plates are not supplied with the controller. Please order them separately when the controllers are mounted in cascade. End plates Appearance AREA SENSORS PRESSURE / FLOW SENSORS Description Length: 1 m 3.281 ft MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Quick-connection cable is not supplied with the controller. Please order it separately. Appearance PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Model No. Description MS-DIN-E When cascading multiple controllers, or when it moves depending on the way it is installed on a DIN rail, these end plates clamp controllers into place on both sides. Make sure to use end plates when cascading multiple controllers together. STATIC CONTROL DEVICES LASER MARKERS PLC Sensor heads Type Compound pressure Appearance DPH-10-M3(-R) Bendingresistant cable Positive pressure Rated pressure range -100.0 kPa to +100.0 kPa DPH-10-M5(-R) 0 to +1.000 MPa Bending-resistant cable Vacuum pressure DPH-10(-R) 0 to -101.0 kPa Bendingresistant cable Model No. Applicable fluid Pressure port ENERGY MANAGEMENT SOLUTIONS DPH-101 R1/8 male thread + M5 female thread DPH-101-M3 M3 male thread DPH-101-M5 M5 male thread DPH-101-R R1/8 male thread + M5 female thread DPH-101-M3-R M3 male thread DPH-101-M5-R M5 male thread DPH-102 (Note) R1/8 male thread + M5 female thread DPH-102-M5 M5 male thread DPH-102-M5-R M5 male thread DPH-103 R1/8 male thread + M5 female thread DPH-103-M3 M3 male thread DPH-103-M5 M5 male thread DPH-103-R R1/8 male thread + M5 female thread Pressure/ Head-separated DPH-103-M3-R M3 male thread Flow DPH-103-M5-R M5 male thread FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Air, non-corrosive gas Selection Guide Pressure/ Digital Display Note: The bending-resistant cable type of DPH-102 is not available. 5 m 16.404 ft cable length type 5 m 16.404 ft cable length type (standard: 2 m 6.562 ft) is also available. When ordering this type, suffix"-C5" to the Model No. (e.g.) 5 m 16.404 ft cable length type of DPH-103-M5-R is "DPH-103-M5-R-C5" OPTIONS Designation Model No. Controller mounting bracket MS-DIN-2 Mounting bracket for controller FX-MB1 10 sets of 2 communication window seals and 1 connector seal Communication window seal: It prevents malfunction due to transmission signal from another controller, as well as, prevents effect on another controller. Connector seal: It prevents contact of any metal, etc., with the pins of the quick-connection cable. Controller protection seal HUMAN MACHINE INTERFACES Description Controller mounting Controller bracket protection seal * MS-DIN-2 * FX-MB1 Communication window seal Connector seal DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 749 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Head-separated Dual Display Digital Pressure Sensor SPECIFICATIONS Controllers Type Item Model No. Positive pressure : DPH-102 Rated pressure range Positive pressure: 0 to +1.000 MPa Display / set pressure range Compound pressure: -199.9 to +199.9 kPa Vacuum pressure: +101.3 to -101.3 kPa Positive pressure: -1.050 to +1.050 MPa Supply voltage 12 to 24 V DC 10 % Ripple P-P 10 % or less Power consumption (Note 2) Normal operation: 650 mW or less (Current consumption 25 mA or less at 24 V supply voltage) ECO mode: 500 mW or less (Current consumption 20 mA or less at 24 V supply voltage) Sensor head supply voltage HUMAN MACHINE INTERFACES Input voltage range: 1 to 5 V DC (over rated pressure range) NO/NC, selectable by jog switch Minimum 0 digit, variable by hysteresis setting Repeatability With compound pressure type connected: within 0.2 % F.S. (4 digits), With vacuum/positive pressure type connected: within 0.2 % F.S. (2 digits) Response time 150 s, 500 s, 1 ms, 5 ms, 10 ms, 50 ms, 100 ms, 500 ms, selectable by jog switch Ambient temperature -10 to +50 C +14 to +122 F (cascading 8 to 16 controllers: -10 to +45 C +14 to +133 F) (No dew condensation or icing allowed), Storage: -20 to +70 C - 4 to +158 F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Temperature characteristics Enclosure: Heat-resistant ABS, Protective cover: Polycarbonate, Jog switch: ABS, MODE key: Acrylic Weight Net weight: 20 g approx. UV CURING SYSTEMS Sensor heads Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. Excluding current consumption of the applicable pressure sensor head. 25 mA max. if 5 or more controllers are connected together. In case of using the quick-connection cable (cable length: 5 m 16.404 ft)(optional) The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below. Main cable (4-core): CN-74-C1 (cable length: 1m 3.281 ft), CN-74-C2 (cable length: 2 m 6.562 ft), CN-74-C5 (cable length: 5 m 16.404 ft) Sub cable (2-core): CN-72-C1 (cable length: 1m 3.281 ft), CN-72-C2 (cable length: 2 m 6.562 ft), CN-72-C5 (cable length: 5 m 16.404 ft) The values specified above are applied only to the controller. Type Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 Over ambient temperature range -10 to +50 C +14 to +122 F: within 0.5 % F.S. of pressure at +25 C +77 F Material MACHINE VISION SYSTEMS FA COMPONENTS NPN open-collector transistor * Maximum sink current: 50 mA (Note 3) * Applied voltage: 30 V DC or less (between comparative output and 0 V) * Residual voltage: 1.5 V or less (Note 4) [at 50 mA (Note 3) sink current] Hysteresis Notes: 1) 2) 3) 4) 5) 6) ENERGY MANAGEMENT SOLUTIONS Same as supply voltage Sensor head input Output operation PLC DPS-402 EMC Directive, RoHS Directive Compound pressure: -100.0 to +100.0 kPa Vacuum pressure: 0 to -101.0 kPa WIRE-SAVING SYSTEMS LASER MARKERS For positive pressure DPS-401 Compound pressure : DPH-101 Vacuum pressure : DPH-103 Applicable sensor head Comparative outputs (Comparative output 1, 2) STATIC CONTROL DEVICES For compound pressure / vacuum pressure CE marking directive compliance SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS DPS-400 SERIES DPH-100 SERIES Item Compound pressure Positive pressure Vacuum pressure 100 kPa type 1 MPa type -101 kPa type Model No. (Note 3) DPH-101(-R) DPH-101-M3(-R) DPH-101-M5(-R) CE marking directive compliance Type of pressure Rated pressure range Pressure withstandability DPH-102 DPH-102-M5(-R) DPH-103(-R) DPH-103-M3(-R) DPH-103-M5(-R) EMC Directive, RoHS Directive Gauge pressure -100.0 to +100.0 kPa 0 to +1.000 MPa 0 to -101.0 kPa 500 kPa 1.5 MPa 500 kPa Applicable fluid Air, non-corrosive gas Supply voltage 12 to 24 V DC 10 % Ripple P-P 10 % or less Current consumption 15 mA or less Ambient temperature 0 to +50 C +32 to +122 F (No dew condensation allowed), Storage: -10 to +60 C +14 to +140 F Ambient humidity Temperature characteristics Front case: PBT, Rear case: PBT (glass fiber reinforced), Pressure port: Stainless steel (SUS303), O-ring: NBR Pressure element: Silicon diaphragm, PPS Material 0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have bending-resistant, oil-resistant cabtyre cable) Cable Cable extension Net weight Weight Gross weight Accessory Notes: 1) 2) 3) 4) 35 to 85 % RH, Storage: 35 to 85 % RH Over ambient temperature range 0 to +50 C +32 to +122 F: within 2 % F.S. of detected pressure at +25 C +77 F Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable. DPH-10(-R): Head 10 g approx. / Cable 40 g approx., DPH-10-M3/M5(-R): Head 6 g approx. / Cable 40 g approx. DPH-10(-R): 80 g approx., DPH-10-M3/M5(-R): 70 g approx. Connector (e-CON): 1 pc. (Note 4) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +25 C +77 F. The sensor head can be used independently. Model No. having the suffix "-R" is bending-resistant cable type. The bending-resistant cable type of DPH-102 is not available. Connectors (e-CON) are available as spare parts. CN-EP2: 5 pcs. Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES 750 I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram ZD3 Analog voltage input 0V PHOTOELECTRIC SENSORS Terminal No. +V (Brown) +V (Note1) Tr1 Tr2 D1 (Black) Comparative output 1 (White) Comparative output 2 ZD1 Load Load 50 mA max.(Note2) Comparative output 1 12 to 24 V DC 10 % Terminal No. Comparative output 2 0V Analog voltage input AREA SENSORS Model SAFETY LIGHT CURTAINS / discrimination SAFETY signal 0V ZD2 (Blue) 0 V (Note1) 50 mA max.(Note2) Sensor head Controller internal circuit internal circuit Intermediate cable MICRO PHOTOELECTRIC SENSORS +V Color code of connector attached cable Controller main circuit Sensor head main circuit 1 k +V Model discrimination signal LASER SENSORS Quick-connection cable side terminal arrangement diagram Terminal No. D2 FIBER SENSORS COMPONENTS PRESSURE / FLOW SENSORS Users' circuit Notes: 1)The quick-connection sub cable does not have +V (brown) and 0 V (blue). The power is supplied from the connector of the main cable. 2) 25 mA max. if 5 or more controllers are connected together. 3) Do not use the controllers in a series (AND) connection. +V Symbols ... D1, D2 : Reverse supply polarity protection diode ZD1 to ZD3 : Surge absorption zener diode Tr1, Tr2 : NPN output transister Comparative output 1 0V PRECAUTIONS FOR PROPER USE * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. * The DPH-100 series is designed for use with air and non-corrosive gas. It cannot be used with liquid or corrosive and inflammable gases. Wiring * Make sure to use the optional quick-connection cable for the connection of the controller. Extension up to total 50 m 164.042 ft (cascading 9 to 16 controllers: 20 m 65.617 ft) is possible with 0.3 mm2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. Sensor head side terminal arrangement diagram Terminal No. Comparative output 2 PARTICULAR USE SENSORS Sensor head power supply 0V INDUCTIVE PROXIMITY SENSORS Analog voltage input Model discrimination signal SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Refer to p.1566 for general precautions. Others * Use within the rated pressure range. * Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. * Do not use during the initial transient time (controller: 1 sec. approx., sensor head: 50 ms approx.) after the power supply is switched on. * Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 751 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Head-separated Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) Select 2 indicator (Yellow) Select 1 indicator (Yellow) Comparative output 1 operation indicator (Orange) Comparative output 2 operation indicator (Orange) PRESSURE / FLOW SENSORS 10 0.394 SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS 11 0.433 End plate (Optional) 2.75 0.108 M3 (length 18 mm 0.709 in) pan head screws MODE key Decimal point mark (Note1) 75 2.953 Communication window 3 0.118 Jog switch Digital display (Green / Red) 3 0.118 5.6 M3 square nut 0.220 24.7 0.972 1.6 0.063 10.5 0.413 32 1.260 4 0.157 Suitable for 35 mm 1.378 in width DIN rail Material: Polycarbonate 36.5 1.437 24 3 0.945 0.118 Suitable for 35 mm 1.378 in width DIN rail 15 0.591 60 2.362 3 0.118 7 0.276 27.8 1.094 30 1.181 3.95 0.156 Note:Decimal points for pressure value. Above figure shows the DPS-401 (compound pressure / vacuum pressure). Positions of display and the pressure unit on the name plate for DPS-402 (positive pressure) differ from the above figure. CN-74-C1CN-74-C2CN-74-C5 Model No. Length L 1,000 39.370 CN-74-C2 2,000 78.740 HUMAN MACHINE INTERFACES CN-74-C5 5,000 196.850 o3.3 o0.130 cable ( ) 14 0.551 2.9 (0.114 ) 2.54 0.100 ENERGY MANAGEMENT SOLUTIONS 10 0.394 6 0.236 ( ) MACHINE VISION SYSTEMS 2.54 0.100 2.65 0.104 Length L CN-72-C1 1,000 39.370 CN-72-C2 2,000 78.740 CN-72-C5 5,000 196.850 2.54 0.100 7 0.276 10 0.394 13.6 0.535 DPH-10(-R) 3 0.118 7.2 0.283 Sensor head 2.65 0.104 2.54 0.100 0.2 0.008 4.8 0.189 23.4 0.921 6.6 0.260 o8.3 o0.327 5 0.197 o6.2 o0.244 10 0.394 7 0.276 10 0.394 13.6 0.535 3 0.118 7.2 0.283 Sensor head 4.8 0.189 o8.4 o0.331 5 0.197 o3.7 o0.146 cable, (2 m 6.562 ft / 5 m 16.404 ft long) 7.8 0.307 Gasket A R1/ 8 20.5 0.807 14 0.5 0.551 0.020 7 0.276 14 10 0.5510.394 9 0.354 M5 female thread ( ) Hexagonal hole (bolt width 3 0.118, 3.5 0.138 deep) Hexagonal hole (bolt width 5 0.197, 4 0.157 deep) Pressure/ Head-separated 13.2 0.520 2.9 (0.114 ) 10 0.394 6 0.236 R5 R0.197 Pressure/ Digital Display Flow 14 (0.551 ) DPH-10-M3(-R) DPH-10-M5(-R) R6.6 R0.260 Selection Guide o3.3 o0.130 cable 3 0.118 12 10.5 (0.472 )0.413 0.2 0.008 UV CURING SYSTEMS 50 1.969 L Model No. 12 10.5 (0.472 ) 0.413 FA COMPONENTS Sub cable (Optional) * Length L 50 1.969 L CN-74-C1 CN-72-C1CN-72-C2CN-72-C5 Main cable (Optional) * Length L PLC DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 MS-DIN-E Controller 12 0.472 58.7 30.85 2.311 1.215 2.7 8.4 0.106 0.331 3 0.118 INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS The CAD data can be downloaded from our website. DPS-401DPS-402 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PARTICULAR USE SENSORS DPS-400 SERIES DPH-100 SERIES Model No. A DPH-10-M3(-R) .53 0.118 DPH-10-M5(-R) 3.5 0.138 6.6 0.260 o3.7 o0.146 cable, 2 m 6.562 ft long DPH-10-M3(-R): M3 male thread DPH-10-M5(-R): M5 male thread Head-separated Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) MS-DIN-2 The CAD data can be downloaded from our website. Controller mounting bracket (Optional) 21.6 0.850 16 0.630 0.4 0.016 3.2 0.126 10 o1.8 o0.071 5.2 0.205 2-o3.2 o0.126 holes 5 0.394 0.197 35 1.378 2 0.079 2 0.079 7.5 4.2 0.295 0.165 752 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS 8.5 5.2 0.335 0.205 3.2 0.126 DPS-400 SERIES DPH-100 SERIES MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS t1 t 0.039 27 1.063 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100