R Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
Page 1 of 2
44A112X
G
TWO CONDUCTOR CABLE, SHIELDED, JACKETED,
GENERAL PURPOSE, 600 VOLT
SPECIFICATION CONTROL DRAWING Date Revision
SHIELD - COPPER, COATING SAME AS ON CONDUCTOR
EXCEPT TIN-COATED SHIELD WITH SILVER-
COATED HIGH-STRENGTH ALLOY CONDUCTOR
COLD
BEND
PART NUMBER
1/
BEND TESTING WEIGHT
(lb) (± 3%)
MANDREL DIAMETER
(inch) (± 3%)
NOTE: Nominal values are for information only.
Nominal values are not requirements.
MAXIMUM
WEIGHT
(lb/1000 ft)
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
SHIELD
SIZE
(AWG) MINIMUM
JACKET
THICKNESS
(in.)
OUTSIDE
DIAMETER
(in.)
MAXIMUMNOMINAL
NOMINAL
LIFE CYCLE, IMMERSION AND
ACCELERATED AGING
JACKET - RADIATION-CROSSLINKED,
MODIFIED PVF2
This specification sheet forms a part of the latest issue of Raychem Specification 44.
TABLE II. CABLE PERFORMANCE DETAILS
TABLE I. CABLE CONSTRUCTION DETAILS
TITLE
LIFE CYCLE, IMMERSION AND
ACCELERATED AGING COLD
BEND
1-9-06
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
COMPONENT WIRE - 44A011X
© 2006 Tyco Electronics Corporation. All rights reserved.
44A112X-26-*
44A112X-24-*
44A112X-22-*
44A112X-20-*
44A112X-18-*
44A112X-16-*
44A112X-14-*
44A112X-12-*
44A112X-10-*
26
24
22
20
18
16
14
12
10
38
36
36
36
36
36
36
36
36
.008
.008
.008
.008
.009
.009
.009
.009
.010
.006
.006
.006
.006
.007
.007
.007
.007
.008
44A112X-26-*
44A112X-24-*
44A112X-22-*
44A112X-20-*
44A112X-18-*
44A112X-16-*
44A112X-14-*
44A112X-12-*
44A112X-10-*
.102
.118
.132
.148
.170
.184
.218
.256
.299
.107
.123
.137
.153
.175
.189
.225
.265
.314
8.1
11.3
14.5
18.8
25.7
30.2
43.2
61.5
86.3
1.50
1.50
3.00
3.00
3.00
3.00
9.00
9.00
9.00
.250
.375
.375
.375
.500
.500
1.00
1.00
1.00
3.00
3.00
6.00
6.00
6.00
6.00
6.00
10.0
10.0
3.00
3.00
6.00
6.00
6.00
6.00
6.00
10.0
10.0
Review
Page 2 of 2 SCD Number
SPECIFICATION CONTROL DRAWING Revision
G44A112X
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 6 hours
BLOCKING: 150 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute
FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue
IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown
JACKET COLOR: White preferred
JACKET CONCENTRICITY: 70% (minimum)
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 200% (minimum)
Tensile Strength, 4000 lbf/in² (minimum)
JACKET FLAWS:
Spark Test, 1.5 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
LIFE CYCLE: 200 ± 3°C for 168 hours
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND TEST (Post Environmental) : 1000 volts (rms), 60 Hz, 1 minute
PART NUMBER:
The “X” in the part numbers on page 1 shall be replaced by the applicable conductor
material designator as follows:
1 tin-coated copper
2 silver-coated copper
3 nickel-coated copper
4 silver-coated high strength copper alloy (AWG's 26-16 only)
6 nickel-coated high strength copper alloy (AWG's 26-20 only)
The "*" in the part numbers on page 1 shall be replaced by color code designators
with a slash separating component wire colors and a dash separating the
component wire color from the jacket color.
1/ Example: AWG 20, tin-coated copper, black and white component wires;
white jacket: 44A1121-20-0/9-9
1/ see footer section on page 1