Solving your relay requirements since 1922 DF10 Series Flasher Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com ... Solid-state analog flasher circuitry ... DPDT (2 form C) isolated 10 ampere relay contacts ... Fixed flash rate: Available from 10 to 240 FPM ... 12V to 120V input voltage available - Both AC and DC models ... UL File #E96739 (M) ... CSA File #LR62586-3 Timing Mode: On/off recycling flasher. The flash rates are fixed and are available from 10 to 240 flashes per minute (FPM). Duty cycle is approximately 50 % with custom duty cycles available. Timing Diagram: Contact Information: Arrangement: 2 form C (DPDT) - Diagrams C & D Contact Material: Silver - Cadmium Oxide Rating (Resistive): 10A @ 240V AC Resistive 15A @ 30V DC Resistive 15A @ 120V AC Resistive 1/3 HP @ 120V AC 1/2 HP @ 250V AC Expected Life @ 25 C: 10 Million operations, Mechanical; 100,000 operations minimum at rated loads Environmental Information: Temperature Range: Storage: -60 C to +105 C (-76 F to +221 F) Solving your relay requirements since 1922 Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com Operating: -45 C to +70 C (-49 F to +158 F) Mechanical Information: Termination: 8 pin Octal Style Plug or 11 pin spade terminals (Diagram C&D) Enclosure: White plastic case. LDF10 version has a black case. Weight: 4 oz (114g) approx. Outline Dimensions: Timing Specifications: Flash Rate - Fixed: Standard - 30, 45, 60, 75, 90 & 120 FPM. Custom rates available from 10 to 240 FPM. Flash Rate Tolerance: 10% Initial Dielectric Strength: Between open contacts: 1000V RMS Between adjacent contacts: 1500V RMS Between contacts & coil: 1500V RMS Input Information: Voltage: AC units- 12V, 24V, and 120V; DC units - 12V, 24V, 48V and 110V. Other input voltages available. Power Requirement: AC units: 3VA or less; DC units: 3 Watts or less Transient Protection: 1 Joule Mov Polarity Protection: On DC units - Yes Solving your relay requirements since 1922 Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com Input Voltages & Limits: Nominal Minimum Maximum 12V AC 10V 14V 24V AC 20V 28V 120V AC 105V 130V 12V DC 11V 14V 24V DC 20V 32V 48V DC 41V 55V 110V DC 95V 125V Wiring Diagrams: Ordering Information: Definition of a part number for the Amperite DF10 Series Flasher. Example: A: Denotes nominal input voltage. Voltages available: 12, 24, & 120V AC; 12, 24, 48, & 110V DC. Custom Voltages are available. Solving your relay requirements since 1922 Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com B: Denotes type of input current required for operation: A = AC - Alternating Current D = DC - Direct Current C: Denotes flasher configuration. D: Denotes flash rate. Standard rates are 30, 45, 60, 75, 90 & 120 FPM. Custom rates are available from 10 to 240 FPM. E: Enter "L" if optional 11-pin spade terminals are required (Diagrams B& D). F: Denotes 10A DPDT (2 form C) flasher - DF10 Series. Solving Your Relay Requirements Since 1922