Product Datasheet Search Results:

SKT50.pdf5 Pages, 258 KB, Original
SKT50/06D.pdf4 Pages, 899 KB, Original
SKT50/06D1.pdf5 Pages, 543 KB, Original
SKT50/06DUNF.pdf4 Pages, 150 KB, Original
SKT50/08D.pdf5 Pages, 543 KB, Original
SKT50/12E.pdf5 Pages, 258 KB, Original
SKT50/12E
Semikron
Thyristor, Thyristor, 1200V Forward Blocking Voltage, 12A On-State Current, 100mA Holding Current

Product Details Search Results:

Semikron.com/SKT500-04C
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"500±","I(TSM) Max. (A)":"7.2k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"400","I(H) Max.(A) Holding Current":"500m","@Temp. (°C) (Test Condition)":"85","V(T) Max. (V)":"1.1","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
824 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT500-06C
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"500±","I(TSM) Max. (A)":"7.2k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"600","I(H) Max.(A) Holding Current":"500m","@Temp. (°C) (Test Condition)":"85","V(T) Max. (V)":"0.9","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
824 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT500-08C
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"500±","I(TSM) Max. (A)":"7.2k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"800","I(H) Max.(A) Holding Current":"500m","@Temp. (°C) (Test Condition)":"85","V(T) Max. (V)":"0.9","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
824 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT500-10C
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"500±","I(TSM) Max. (A)":"7.2k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.0k","I(H) Max.(A) Holding Current":"500m","@Temp. (°C) (Test Condition)":"85","V(T) Max. (V)":"0.9","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
825 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT500-12C
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"500±","I(TSM) Max. (A)":"7.2k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.2k","I(H) Max.(A) Holding Current":"500m","@Temp. (°C) (Test Condition)":"85","V(T) Max. (V)":"0.9","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
824 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT500-14C
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"500±","I(TSM) Max. (A)":"7.2k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.4k","I(H) Max.(A) Holding Current":"500m","@Temp. (°C) (Test Condition)":"85","V(T) Max. (V)":"0.9","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
825 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT500-16C
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"500±","I(TSM) Max. (A)":"7.2k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.6k","I(H) Max.(A) Holding Current":"500m","@Temp. (°C) (Test Condition)":"85","V(T) Max. (V)":"0.9","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
825 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT500-18C
{"Status":"Discontinued","I(T) Max.(A) On-state Current":"500±","I(TSM) Max. (A)":"7.2k","Package":"TO-200AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"1.8k","I(H) Max.(A) Holding Current":"500m","@Temp. (°C) (Test Condition)":"85","V(T) Max. (V)":"0.9","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
824 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT50/04C
{"I(T) Max.(A) On-state Current":"50±","I(TSM) Max. (A)":"1.0k","Package":"TO-208AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"400","I(H) Max.(A) Holding Current":"200m","@Temp. (°C) (Test Condition)":"78","V(T) Max. (V)":"1.1","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N"}...
800 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT50/06CUNF
{"I(T) Max.(A) On-state Current":"45±","V(T) Max. (V)":"2.0","@Temp. (°C) (Test Condition)":"130","@ t(w) (s) (Test Condition)":"10m","I(H) Max.(A) Holding Current":"100m","@I(T) (A) (Test Condition)":"120","Package":"TO-208AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"600","dv/dt Min. (V/us)":"200","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"8.0m","I(TSM) Max. (A)":"1.0k","t(q) Typ. (s)":"100u"}...
948 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT50/06D
{"I(T) Max.(A) On-state Current":"45±","V(T) Max. (V)":"1.8","@Temp. (°C) (Test Condition)":"130","@ t(w) (s) (Test Condition)":"10m","I(H) Max.(A) Holding Current":"200m","@I(T) (A) (Test Condition)":"120","Package":"TO-208varM8","V(DRM) Max.(V)Rep.Pk.Off Volt.":"600","dv/dt Min. (V/us)":"500","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"8.0m","I(TSM) Max. (A)":"1.0k","t(q) Typ. (s)":"100u"}...
937 Bytes - 18:49:56, 18 December 2024
Semikron.com/SKT50/06DUNF
{"I(T) Max.(A) On-state Current":"45±","V(T) Max. (V)":"1.8","@Temp. (°C) (Test Condition)":"130","@ t(w) (s) (Test Condition)":"10m","I(H) Max.(A) Holding Current":"200m","@I(T) (A) (Test Condition)":"120","Package":"TO-208AC","V(DRM) Max.(V)Rep.Pk.Off Volt.":"600","dv/dt Min. (V/us)":"500","I(GT) Max. (A)":"150m","V(GT) Max.(V)":"3.0","Military":"N","I(D) Max. (A) Leakage Current":"8.0m","I(TSM) Max. (A)":"1.0k","t(q) Typ. (s)":"100u"}...
949 Bytes - 18:49:56, 18 December 2024

Documentation and Support

Use our online request for specific proposed solutions or send your technical question directly to a product specialist at request:

File NameFile Size (MB)DocumentMOQSupport
SKT50-16E1.pdf0.531Request
SKT50_16E.pdf0.151Request
SKT50-14E1.pdf0.531Request
SKT50_18E.pdf0.251Request
SKT50-08D.pdf0.531Request
SKT50-12E1.pdf0.531Request
SKT50-18E.pdf0.531Request
SKT50_08D.pdf0.881Request
SKT50-06D1.pdf0.531Request