Cables you trust. Service you deserve.
EcoFlex™ Cable
Smaller. Lighter. Tougher. 100% Recyclable.
Total Performance,
Completely Recyclable
EcoFlex cable is Alpha Wire’s
newest innovation in control
cabling. A true engineering
breakthrough, EcoFlex cable
combines better performance
with a minimum environmental
impact. It derives its
advantages from modified
polyphenylene ether (mPPE)
jacketing and insulation.
EcoFlex is:
100% Recyclable
Up to 32% smaller
Up to 55% lighter
Capable of handling
temperatures extremes
to -40°C
Up to 91% lower outgassing
Rated for over 1 million
flex cycles
mPPE Insulation:
All the Advantages in Smaller, Lighter Control Cable
Environmentally Friendly
EcoFlex cable contains no
halogens, phthalates, or heavy
metals. The mPPE thermoplastic
insulation and jacketing can
be easily recycled. They meet
RoHS and WEEE requirements
for the elimination of hazardous
substances and recyclability.
Low Specific Gravity
The 1.03 specific gravity of
mPPE is 25% to 40% lower than
other insulation materials,
such as PVC, polyethylene, and
cross-linked polyethylene. Along
with the reduced wall thickness,
the low specific gravity yields
significant weight savings of up
to 55% with EcoFlex cable.
Better Dielectric Strength
The superior dielectric properties
of mPPE make a reduced
wall thickness possible, while
maintaining the same electrical
properties as a thicker PVC
control cable.
More Choice in EMI
Protection
Alpha Wire offers EcoFlex
cable in three shielding options
to handle any electrical
environment.
Unshielded
Braid Shielded
SupraShield® Foil + Braid Shield
Superior Availability
EcoFlex cables are available
from stock in most sizes and
constructions, with put-ups
as small as 100 feet. Alpha Wire
provides same-day shipment
and next-day delivery to
practically anywhere in
the world.
Visit www.alphawire.com/
EcoGen to request
free samples
Alpha Wire’s next generation of
eco-friendly, high-performance
wire and cable, designed to
provide better performance in a
smaller package.
EcoCable™
EcoFlex™ Cable
EcoWire™
EcoWire™ Plus
Learn more about the new
EcoGen family of products at
www.alphawire.com/EcoGen
Properties EcoFlex Cable
Diameter Up to 32% smaller
Weight 55% lighter
Temperature Range -40°C to 105°C static, -5°C to 105°C Flexing
Outgassing 91% lower
Recyclability 100%
Availability 100’, 1000’
EcoFlex Cable
Specifications
Materials
Conductors:
Stranded tin-plated copper
Insulation: mPPE
Jacket: mPPE, slate
Electrical
Voltage: 600 V
Bend Radius
Unshielded: 5x Static, 5x Flexing
Shielded: 6x Static, 8x Flexing
Physical and Mechanical
Temperature Range:
-40°C to 105°C
Availability
100 ft (30.5 m) and
1000 ft (305 m) lengths
Conductor No
No. Base
Color 1st
Stripe 2nd
Stripe
1 Black
2Red
3 White
4 Green
5 Orange
6 Blue
7 Brown
8 Yellow
9 Violet
10 Slate
11 Pink
12 Ta n
13 Red Green
14 Red Yellow
15 Red Black
16 White Black
17 White Red
18 White Green
19 White Yellow
20 White Blue
21 White Brown
22 White Orange
23 White Slate
24 White Violet
25 White Black Red
Key Features
Compact cable for
moderate flex applications
Rated for more than
1 million flex cycles
Easier routing and handling
Approvals
UL AWM 21819 (600 V, 105°C)
UL AWM 21492 (300 V, 80°C)
CE
UL VW-1
RoHS Compliant
CSA AWM I/II A/B FT1
REACH Compliant
WEEE
Suitable for use in
NFPA79 Applications
IEC 60332-2 Flame Behavior
20 AWG (0.51 mm2) Cable
Request free samples
at www.alphawire.com/
EcoFlex
EcoFlex Cable
Unshielded
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79061 2 0.142 3.61
79062 30.147 3.73
26 AWG (0.14 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79056 2 0.150 3.81
79057 3 0.156 3.96
79058 4 0.166 4.22
79059 60.189 4.80
79060 8 0.216 5.49
24 AWG (0.24 mm2)
Stranding: 19/36 (19 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79050 2 0.162 4.11
79051 30.169 4.29
79052 4 0.181 4.60
79053 6 0.207 5.26
79054 8 0.238 6.05
79055 10 0.257 6.53
22 AWG (0.38 mm2)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79044 20.176 4.47
79045 3 0.184 4.67
79046 4 0.198 5.03
79047 6 0.228 5.79
79048 8 0.264 6.71
79049 10 0.286 7.26
20 AWG (0.51 mm2)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79001 2 0.184 4.67
79002 30.193 4.90
79003 4 0.207 5.26
79004 5 0.224 5.69
79005 7 0.240 6.10
79006 9 0.296 7.52
79007 12 0.303 7.70
79008 18 0.349 8.86
EcoFlex Cable
Unshielded
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors Nominal Diameter
Inch mm
79028 2 0.266 6.76
79029 3 0.281 7.14
79030 4 0.307 7.80
79031 5 0.335 8.51
79032 7 0.364 9.25
79033 9 0.459 11.66
79034 12 0.473 12.01
79035 18 0.556 14.12
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79010 2 0.208 5.28
79011 3 0.219 5.56
79012 4 0.236 5.99
79013 5 0.256 6.50
79014 7 0.277 7.04
79015 9 0.344 8.74
79016 12 0.353 8.97
79017 18 0.411 10.44
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79019 2 0.236 5.99
79020 30.249 6.32
79021 40.270 6.86
79022 5 0.294 7.47
79023 7 0.319 8.10
79024 9 0.400 10.16
79025 12 0.411 10.44
79026 18 0.481 12.22
12 AWG (3.29 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors Nominal Diameter
Inch mm
79037 3 0.326 8.28
79038 4 0.358 9.09
79039 50.392 9.96
79040 7 0.428 10.87
10 AWG (5.32 mm2)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors Nominal Diameter
Inch mm
79041 3 0.38 9.65
79042 4 0.423 10.74
79043 5 0.465 11.81
20 AWG (0.51 mm2)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79101 2 0.210 5.33
79102 3 0.219 5.56
79103 4 0.233 5.92
79104 5 0.250 6.35
79105 7 0.266 6.76
79106 9 0.321 8.15
79107 12 0.329 8.36
79108 18 0.376 9.55
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors Nominal Diameter
Inch mm
79121 2 0.294 7.47
79122 3 0.309 7.85
79123 4 0.335 8.51
79124 5 0.363 9.22
79125 70.392 9.96
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79109 2 0.236 5.99
79110 30.247 6.27
79111 4 0.264 6.71
79112 5 0.284 7.21
79113 7 0.305 7.75
79114 90.372 9.45
79115 12 0.381 9.68
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79116 2 0.262 6.65
79117 30.275 6.98
79118 4 0.396 10.06
79119 5 0.320 8.13
79120 7 0.345 8.76
12 AWG (3.29 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors Nominal Diameter
Inch mm
79126 3 0.354 8.99
79127 4 0.386 9.80
EcoFlex Cable
Braid Shield
20 AWG (0.51 mm2)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79201 2 0.216 5.49
79202 3 0.225 5.72
79203 4 0.239 6.07
79204 5 0.256 6.50
79205 70.272 6.91
79206 9 0.328 8.33
79207 12 0.335 8.51
79208 18 0.382 9.70
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.13 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79261 20.174 4.42
79262 30.179 4.55
22 AWG (0.38 mm2)
Stranding: 19/34 (19 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79244 2 0.208 5.28
79245 3 0.216 5.49
79246 4 0.23 5.84
79247 6 0.26 6.60
79248 8 0.296 7.52
79249 10 0.318 8.08
EcoFlex Cable
Supra-Shield® Foil + Braid
26 AWG (0.14 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79256 2 0.182 4.62
79257 3 0.188 4.78
79258 4 0.198 5.03
79259 6 0.221 5.61
79260 8 0.248 6.30
24 AWG (0.24 mm2)
Stranding: 19/36 (19 x 0.13 mm)
Insulation thickness: 0.011 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79250 2 0.194 4.93
79251 3 0.201 5.11
79252 4 0.213 5.41
79253 6 0.239 6.07
79254 80.27 6.86
79255 10 0.289 7.34
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors Nominal Diameter
Inch mm
79225 2 0.300 7.62
79226 3 0.315 8.00
79227 40.341 8.66
79228 5 0.369 9.37
79229 7 0.398 10.11
79230 90.493 12.52
79231 12 0.507 12.88
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79210 2 0.242 6.15
79211 3 0.253 6.43
79212 40.270 6.86
79213 5 0.290 7.37
79214 7 0.311 7.90
79215 90.378 9.60
79216 12 0.387 9.83
79217 18 0.445 11.30
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.011 (0.28 mm)
Jacket thickness: 0.035 (0.89 mm)
Part Number Conductors Nominal Diameter
Inch mm
79218 2 0.268 6.81
79219 3 0.281 7.14
79220 4 0.302 7.67
79221 5 0.326 8.28
79222 7 0.351 8.92
79223 9 0.432 10.97
79224 12 0.443 11.25
12 AWG (3.29 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors Nominal Diameter
Inch mm
79232 3 0.360 9.14
79233 4 0.391 9.93
79234 5 0.426 10.82
79235 7 0.462 11.73
10 AWG (5.32 mm2)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.012 (0.30 mm)
Jacket thickness: 0.035 (0.81 mm)
Part Number Conductors Nominal Diameter
Inch mm
79236 30.419 10.64
79237 4 0.457 11.61
EcoFlex Cable
Supra-Shield® Foil + Braid
Cables you trust.
Service you deserve.
Every application is critical
and cable failure is not an
option when the safety of your
equipment and personnel is
paramount. Specify Alpha
products since the integrity of
your system is only as robust as
the products you use.
Superior availability
Alpha offers wire and cable
from stock in most sizes and
constructions, in both small and
large put-ups, so you can order
it when you need it. Our
products are available for
same-day shipment, eliminating
long lead times.
©2012 Alpha Wire. All rights reserved. Specifications subject to change. Lit. No. EcoF-Bro-1212
Consult Alpha Wire for latest specifications. EcoCable, EcoFlex, EcoGen, EcoWire, and EcoWire Plus are trademarks of Alpha Wire. Supersedes: New
Service and support,
second-to-none
Selecting the correct cable
for your critical application
is essential to overall system
reliability, performance, and
safety. So we make it easy
for you select the right Alpha
product for your specific
application. Our online
resources include a wire and
cable selection guide, technical
information, full product
catalog, and a distributor
locator to make it easy to select
and get the wire or cable you
need. Can’t find what you’re
looking for? Design the cable to
your specification. It’s easy, just
visit www.alphawire.com!
Cables you trust. Service you deserve.
GLOBAL HEADQUARTERS
711 Lidgerwood Avenue
Elizabeth, NJ 07207-0711 USA
Toll Free: 1-800-52 ALPHA
Tel: 1-908-925-8000
Fax: 1-908-925-5411
E-mail: info@alphawire.com
EUROPE
Alpha Wire International
Saxon House
1 Downside | Sunbury-on-Thames
Middlesex | United Kingdom
TW16 6RT
Tel: +44-(0)-800-288-8809
Fax: +44-(0)-800-288-8810
E-mail: europe@alphawire.com
ASIA PACIFIC
Alpha Wire
Silver Center | Room 1708
North Shanxi Road 1388
Shanghai | China | 200060
Tel: +86-21-61498201/61498205
Fax: +86-21-61498001
E-mail: apac@alphawire.com
Alpha Wire’s next generation of
eco-friendly, high-performance
wire and cable, designed to
provide better performance in a
smaller package.