P2100 Series Differential Pressure Transducer The P2100 series of transducers is designed for differential pressure measurement of wet and/or corrosive fluids. There is a range of models with full range pressure from 10 psi D to 3,500 psi D. Common line pressures up to 5000 psi can be accommodated with minimal effect on the output and each port is equipped with overpressure protection (up to 5 times range on P1). A selection of electrical outputs is available from 20 mV to 4-20 mA two wire the latter having the option of BASEEFA approval. The P21X1 to P21X4 series is designed for use with fluids which can deposit some form of residue within a cavity and therefore the pressure ports can be removed for cleaning. The P21X6 to P21X9 series is an all welded construction with the wetted ports made from Hasteloy C-276. This instrument is designed to handle highly corrosive fluids but also has applications where size and weight are at a premium. Environmental (all models) Temperature Compensated Range ................................. 32F to 185F (0C to 85C) Operating Temperature Range High Range .................... -22F to 248F (-30 to 120C) Medium Range .............. -5F to 212F (-20 to 100C) Storage Temperature ........ -22F to 266F (-30 to 130C) Humidity Cable Outlet .................. Immersible to 100 ft (30.5 m) Connector Outlet .......... 95% relative humidity Mechanical Natural Frequency High Range .................... Approx. 4 kHz for 75 psi (5.0 bar) up to 15 kHz for 1000 psi (70 bar) Medium Range .............. Approx. 2 kHz for 10 psi (0.7 bar) up to 3.0 kHz for 25 psi (1.7 bar) Steady Acceleration and Linear Vibration .... 0.5% F.R.O./g for 10 psi (0.7 bar) decreasing to less than 0.02% F.R.O./g for 500 psi (35 bar) and above. Features Differential measurement of corrosive fluids Bi-directional differential pressure (calibrated option) High overload protection in either direction Low and high level output Removable pressure ports 2 wire 4-20 mA option BASEFA and CENELEC approval class EEx ia IIc T4 (Tamb=60C) Frequency range 0-2 kHz at 20g max. limited to 8mm double amplitude Shock ................................. 1000g for 5 milliseconds in any axis will not damage the sensor. Altitude .............................. -150 feet to +70,000 feet without damage Insulation Resistance ....... 500 Megohms at 50 VDC @ 25C Internet: www.schaevitz.com North America Tel: 800/745-8008 Fax Back System: 916/431-6541 Europe Tel: (01753) 537622 164 P2100 Series Pressure Ranges: 0-10 to 3500 psi (0-0.7 to 250 bar) Accuracy: 0.35% F.R.O. Specifications by Model @ 77F (25C) Model Number P2101/9 Input Voltage 10 VDC (12 V max) Resistance 350 ohm 5% Current 30 mA Output Unidirectional 0-0.7 bar 20mV to 25mV 0-1 bar & above 25mV 2% Bidirectional 0.7 bar 10mV min. 1 bar & above 12.5mV 2% Resistance (ohm) Current mA (max) Load Resistance 350 5% 10 mA Residual Unbalance(FRO) 2% Accuracy: Combined Non-Linearity Hysteresis and Non-Repeatability Thermal Zero Shift 0.015% FRO/C 0.015% FRO/C of total BD output on BD option Thermal Sensitivity Shift 0.015% FRO/C 0.15% FRO/C of total BD output on BD option Weight oz (gm) P21X1/4 35.7 (1000) P21X6/9 18.9 (530) P2141/9 10 VDC (12 V max) P2151/9 11-18 VDC P2161/9 18-36 VDC P2181/9 10-36 VDC P2191/9 15 VDC 30 mA 30 mA 35 mA -- +30/-2 mA 0-2.5V 2% 0-2.5V 2% 0-2.5V 2% 0-2.5V 2% 0-2.5V 2% 16 mA 2% 0-2.5V 2% (4-20 mA) 2% -- 0-5V 2% 2.5V 2% 2.5V 2% 2.5V 2% 2.5V 2% 2.5V 2% 2.5V 2% -- 5V 2% <10 5 mA <10 5 mA <10 5 mA 2% 2% 2% 4-20 mA 2% (16 mA) 2% -- -- 0 at 10V to 1300 ohm at 36V 2% <10 5 mA 2% 0-35% FRO (BSL) Each port separately on BD option 0.02% FRO/C 0.02% FRO/C of total BD output on BD option 0.02% FRO/C 0.02% FRO/C of total BD output on BD option 35.7 (1000) 18.9 (530) 35.7 (1000) 18.9 (530) 35.7 (1000) 18.9 (530) 35.7 (1000) 18.9 (530) 35.7 (1000) 18.9 (530) Common Specifications P21X1/4 P21X6/9 Pressure Ranges Medium psi bar High Range psi bar Line Pressure 10; 15; 25; 35 10; 15; 25; 35 0.7; 1.0; 1.5; 2.5 0.7; 1.0; 1.5; 2.5 75; 100; 150; 250; 500; 1000; 2000; 3500 75; 100; 150; 250; 500; 1000 5; 7; 10; 20; 35; 70; 150; 250 5; 7; 10; 20; 35; 70 3500 psi (250) bar max. standard 1500 psi 5000 psi (350 bar) option (100 bar) max. Zero Shift with Line Pressure 1.0% per 1000 psi (70 bar) Nominal Individual calibration given. BD options nominally 1% of combined BD output. Differential Pressure Limit P1 5x rated pressure or 3750 psi 5x rated pressure or 1500 psi (260 bar) whichever is less (100 bar) whichever is less P2 2 x rated pressure or 3750 psi 2 x rated pressure or 1500 psi (260 bar) whichever is less (100 bar) whichever is less Differential Burst Pressure P1 10 x rated pressure or 5000 psi (350 bar) whichever is less 10 x rated pressure or 2500 psi P2 6 x rated pressure or 4000 psi (170 bar) whichever is less (275 bar) whichever is less Pressure Media Liquids or gases compatible with A1S1300, Liquid or gases compatible with 17-4 & 17-7 SS and Nitrile "O' rings Inconel 625 and Hastelloy C-276 Sensitivity Imbalance P2 = P1 2.5% (1% per 1000 psi) (70 bar) Full Range Pressure Zero Shift with Alternating Full Fange Pressure Cycling (BD) 0.25% FRO on P1 (0.5% FRO on P2) Shunt Calibration (not P218x) 80% 5% full range pressure 165 P2100 Series Differential Pressure Transducer Type Dimensions in (mm) O1.00 (25.4) O2.26 (57.4) Bleed Screw P2101/4 3.20 (81.2) P21X1/4 3.91 (99.2) P21X1/4 0.51 (13.0) 0.75 (19.0) A/F P2 Bleed O1.492 Screw (37.9) P2 0.94 (24.0) A/F 1.13 (28.6) 2.07 (52.5) P21X1/4 Adapters A in (mm) 0.46 (11.9) 0.45 (11.7) 0.40 (10.2) 0.55 (14.2) 0.55 (14.2) 0.38 (9.9) 0.56 (14.4) Thread Size Code 1/4" (BSP) (F) 0001 1/4" (BSP) (M) 0002 M14 x 1.5 (M) 0003 7/16"-20UNF-2A (M) 0004 1/4"-18NPT (M) 0005 M10 x 1.0 (F) 0006 1/4"-18NPT (F) 0007 A (See Table) O1.00 (25.4) 4.15 (105.4) 0.913 (23.2) 3.39 (86.0) A (See Table) P21X6/9 0.512 (13.0) P2106/9 2.53 (64.2) P21X6/9 3.24 (82.2) 0.75 (19.0) A/F P2 P1 O0.866 (22.0) O1.33 (33.8) 0.945 (24.0) A /F 0.736 (18.7) 1.12 (28.4) O1.6 (40.6) A (See Table) P21X6/9 Adapters Connections Cable Red1 White Yellow Blue1,2 Violet Grey 39.37 (1M) Standard A F B E C Connector Orientation 1 D Internet: www.schaevitz.com North America Tel: 800/745-8008 Fax Back System: 916/431-6541 Europe Tel: (01753) 537622 1.866 (47.4) A (See Table) 3.756 (95.4) A in (mm) 0.46 (11.9) 0.47 (11.7) 0.55 (14.2) 0.54 (14.0) Thread Size Code 1/4" (BSP) (F) 0001 1/4" (BSP) (M) 0002 M14 x 1.5 (M) 0003 7/16"-20UNF-2A (M) 0004 1.484 (37.7) 2 166 Connector2 Pin A1 Excitation (+) Pin D Excitation (-) Pin B Output (+) Pin C1,2 Output (-) Pin E 80% shunt calibration Pin F 2-wire transmitter connections 0 Volt P219X, P218X series } P2100 Series Pressure Ranges: 0-10 to 3500 psi (0-0.7 to 250 bar) Accuracy: 0.35% F.R.O. Wiring P2191/9 P2181/9 Excitation +Ve A Red Positive A Red Output +Ve B Yellow Negative B Blue Output -Ve & OV P2101/9 Excitation -Ve Excitation +Ve C Blue D White R. Cal A Red E Violet 80% Calibration Output -Ve C Blue F Grey Excitation -Ve D White P2141/9, P2151/9 and P2161/9 Output +Ve Excitation +Ve B Yellow A Red R. Cal Output +Ve E Violet B Yellow 80% Calibration Output -Ve F Gray C Blue Excitation -Ve D White Designation and Ordering Information Specify by transducer Type number, coding, pressure range and UD or BD (UD = Unidirectional, BD = Bidirectional) R.Cal E Violet 80% Calibration Example: P2101-0022, 0-10 bar UD signifies "Pressure transducer, cable outlet and 1/4 BSP male screw in pressure adapter, with metal/nitrile rubber bonded seal, ranged 0-10 bar UD with 0-25mV output from 10 VDC supply. Type No. & Code P21 0- 4- 5- 6- 8- 9- 25mV output 2.5V output (10V supply) 2.5V output (11-18V supply) 2.5V output (18-32V supply) 4-20 mA output (10-36V supply) 5V output (+15.0-15V supply F Grey 0 Intrinsic Safety 0 - Non IS 9 - IS (P2180 only) 1 - High range - cable outlet 2 - Medium range - cable outlet 3 - High range - connector outlet 4 - Medium range - connector outlet 6 - High range - cable outlet with Inconel wetted parts 7 - Medium range - cable outlet with Inconel wetted parts 8 - High range - connector outlet with Inconel wetted parts 9 - Medium range - connector outlet with Inconel wetted parts 0 - Welded adaptor 2 - Screw in adapter 1 2 3 4 5 6 1/4 BSP female 1/4 BSP male 14 x 1.5 male* 7/16 in-20 UNF 2A male* 1/4 in-18 NPT male* 10 x 1 mm Arsero* Ermeto female 9 1/4 in 18 NPT female* *Inconel only to special order 167 Unit B: bar P: psi Pressure Reference UD: uni-directional BD: bi-directional Pressure Range (Enter full scale pressure range without units) High (bar) 0-5; 7; 10; 20; 35; 70; 150; 250 (psi) 0-75; 100; 150; 250; 500; 1000; 2000; 3500 Medium (bar) 0.7; 1.0; 1.5; 2.5 (psi) 0-10; 15; 25; 35