40W Single Output Industrial DIN Rail Power Supply MDR-40 series Features : Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 NEC class 2 / LPS compliant (12V,24V,48V only) LED indicator for power on DC OK relay contact No load power consumption<0.75W 100% full load burn-in test 3 years warranty SPECIFICATION MODEL MDR-40-5 MDR-40-12 MDR-40-24 MDR-40-48 DC VOLTAGE 5V 12V 24V 48V RATED CURRENT 6A 3.33A 1.7A 0.83A CURRENT RANGE 0 ~ 6A 0 ~ 3.33A 0 ~ 1.7A 0 ~ 0.83A RATED POWER 30W 40W 40.8W 39.8W 120mVp-p 150mVp-p 5 ~ 6V 12 ~ 15V 24 ~ 30V 200mVp-p 48 ~ 56V VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% RIPPLE & NOISE (max.) Note.2 80mVp-p OUTPUT VOLTAGE ADJ. RANGE SETUP, RISE TIME INPUT Note.5 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC 0.7A/230VAC COLD START 30A/115VAC 60A/230VAC <1mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE FUNCTION DC OK SIGNAL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY EMC (Note 4) OTHERS 86% 88% 88% 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6.25 ~ 7.25V 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover Relay contact rating(max.): 30V/1A resistive -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 0.03%/ (0 ~ 50 Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 UL508, UL60950-1, TUV EN60950-1 approved, NEC class 2 / LPS compliant (12V,24V,48V only) EMS IMMUNITY Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A MTBF 301.7K hrs min. MIL-HDBK-217F (25 40*90*100mm (W*H*D) 0.3Kg; 42pcs/13.6Kg/0.82CUFT I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT DIMENSION PACKING NOTE 20ms/115VAC at full load 120 ~ 370VDC EFFICIENCY (Typ.) LEAKAGE CURRENT SAFETY & 500ms, 30ms/115VAC at full load ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:MDR-40-SPEC 2010-12-07 http://store.iiic.cc/ MDR-40 40W Single Output Industrial DIN Rail Power Supply Mechanical Specification Case No.962A 35 40 series Unit:mm 100 5 5 5 5 5 +V +V -V -V DC OK DC OK + 90 +V ADJ N L 7.5 7.5 Install DIN rail TS35/7.5 or TS35/15 Block Diagram fosc : 60KHz DC OK RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V O.C.P. DETECTION CIRCUIT O.L.P. CONTROL O.V.P. DC OK Relay Contact Contact Close PSU turns on / DC OK. Contact Open PSU turns off / DC Fail. Contact Ratings (max.) 30V/1A resistive load. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 45 55 60 70 (VERTICAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz AMBIENT TEMPERATURE ( ) File Name:MDR-40-SPEC 2010-12-07 http://store.iiic.cc/