88 102417
TCB Series
COTS-Plus Polymer Capacitor
The TCB series is a COTS-Plus version of the professional grade
TCR polymer series.
L
SAAW
1
W
H
CASE DIMENSIONS: millimeters (inches)
Code EIA EIA L±0.20 W+0.20 (0.008) H+0.20 (0.008) W1±0.20 A+0.30 (0.012) S Min.
Code Metric (0.008) -0.10 (0.004) -0.10 (0.004) (0.008) -0.20 (0.008)
B 1210 3528-21 3.50 (0.138) 2.80 (0.110) 1.90 (0.075) 2.20 (0.087) 0.80 (0.031) 1.40 (0.055)
D 2917 7343-31 7.30 (0.287) 4.30 (0.169) 2.90 (0.114) 2.40 (0.094) 1.30 (0.051) 4.40 (0.173)
Y 2917 7343-20 7.30 (0.287) 4.30 (0.169) 2.00 (0.079) max 2.40 (0.094) 1.30 (0.051) 4.40 (0.173)
W1dimension applies to the termination width for A dimensional area only.
B, D, Y CASE
XXXXX
686 A
AVX LOGO
Polymer Capacitance Value in pF
686 = 68µF
Rated Voltage
A = 10V
ID Code
Polarity
Band
(Anode+)
MARKING
Capacitance Rated Voltage
μF Code 4V(G) 6.3V(J) 10V(A) 16V(C) 20V(D) 25V(E) 35V(V) 50V(T)
10 106 D(70) D(120)
15 156 D(70)
22 226 B(70) D(70)
33 336 B(70) D(70)
47 476 B(70) D(70)
68 686 D(70)
100 107 D(70)
150 157 D(40)
220 227 D(40), Y(40)
CAPACITANCE AND RATED VOLTAGE, VR(VOLTAGE CODE) RANGE (LETTER DENOTES CASE SIZE)
Available Ratings (ESR ratings in mOhms in brackets)
Engineering samples – please contact manufacturer
Note: Voltage ratings are minimum values. AVX reserves the right to supply higher
voltage ratings in the same case size to the same reliability standards
FEATURES
• Robust design for long operation lifetime
• AVX Q-process with statistical screening
• 100% Accelerated Ageing
• Surge testing level option
• Improved basic reliability 0.5%/1000hrs
• Humidity 85°C/85%RH, Vr, 500/1000 hours
• - 55 to +125°C operation temperature
• Shock and Vibration by MIL-STD-202
• DCL 0.1 CV
• 3x reflow 260°C compatible
• Benign failure mode under recommended use conditions
APPLICATIONS
Long life time DC/DC converter applications in Telecommunications, Industrial, Avionics.
For additional information on Q-process please consult the AVX technical publication
“Reaching the Highest Reliability for Tantalum Capacitors” (see the link:
http://www.avx.com/docs/techinfo/Qprocess.pdf)
89
110916
TCB Series
COTS-Plus Polymer Capacitor
Technical Data: All technical data relate to an ambient temperature of +25ºC
Capacitance Range: 10μF to 220μF
Capacitance Tolerance: ±20%
Leakage Current DCL: 0.1CV
Temperature Range: -55ºC to +125°C
Basic Reliability: 0.5% per 1000 hours at 85ºC, Vr with 0.1ΩV series impedance, 60% confidence level
Termination Finish: Sn Plating or SnPb Plating (Non RoHS)
TECHNICAL SPECIFICATIONS
M
Tolerance
M = ±20%
Packaging
R = 7" T&R
S = 13" T&R
00
Surge Test
Option
00 = Standard
23 = 10x Cycles, 25°C
24* = 10x Cycles,
-55°C & +85°C
*Please contact AVX for
Surge option
TCB
Type
C
ESR
C = Std ESR
L = Low ESR
S
Inspection Level
S = Standard
Conformance
HOW TO ORDER
AVX PART NUMBER:
010
Rated DC
Voltage
004 = 4Vdc
006 = 6.3Vdc
010 = 10Vdc
016 = 16Vdc
020 = 20Vdc
025 = 25Vdc
035 = 35Vdc
050 = 50Vdc
107
Capacitance
Code
pF code:
1st two digits
represent
significant
figures 3rd digit
represents
multiplier
(number of
zeros to follow)
Z
Reliability
Grade
Z = Non-ER
^
Termination Finish
7 = 100% Tin
H* = Sn/Pb Non RoHS
*Contact Manufacturer
D
Case
Size
See
table
on
previ
ous
page
0
Qualification
Level
0 = N/A
NOTE: Conductive Polymer Capacitors are designed to operate within the limits of the environmental conditions specified for each series. If operated continuously at
their maximum temperature and / or humidity limit, or beyond these limits, capacitors may exhibit a parametric shift in capacitance and increases in ESR. These
changes may occur earlier if the specified environmental conditions are exceeded. Similarly, their normal operational time period will be significantly extended if their
general duty cycle includes operation below maximum temperature within humidity controlled environments. Careful attention should be paid to maximum temperature
with associated high humidity environments as well as voltage derating, ripple current and current surges. Please reference the AVX Conductive Polymer Capacitor
Guidelines for more information or contact factory for application assistance.
90 110916
TCB Series
COTS-Plus Polymer Capacitor
RATINGS & PART NUMBER REFERENCE
Rated Maximum DCL DF ESR 100kHz RMS Current (mA) Humidity
AVX Case Capacitance Voltage Operating Max. Max. Max. MSL 85ºC/
Part No. Size (μF) (V) Temperature (μA) (%) @ 100kHz 45ºC 85ºC 105ºC 125ºC 85%RH, Vr
(ºC) (mΩ) (hrs)
4 Volt
TCBD227M004CSZ0700 D 220 4 125 88 6 40 3 2400 1700 1100 600 1000
TCBD227M004CSZ0723 D 220 4 125 88 6 40 3 2400 1700 1100 600 1000
TCBY227M004CSZ0700 Y 220 4 125 88 6 40 3 2200 1500 1000 600 500
TCBY227M004CSZ0723 Y 220 4 125 88 6 40 3 2200 1500 1000 600 500
6.3 Volt
TCBB226M006CSZ0700 B 22 6.3 125 13 6 70 3 1300 900 600 300 500
TCBB226M006CSZ0723 B 22 6.3 125 13 6 70 3 1300 900 600 300 500
TCBB336M006CSZ0700 B 33 6.3 125 19 6 70 3 1300 900 600 300 500
TCBB336M006CSZ0723 B 33 6.3 125 19 6 70 3 1300 900 600 300 500
TCBB476M006CSZ0700 B 47 6.3 125 28 6 70 3 1300 900 600 300 500
TCBB476M006CSZ0723 B 47 6.3 125 28 6 70 3 1300 900 600 300 500
TCBD157M006CSZ0700 D 150 6.3 125 90 6 40 3 2400 1700 1100 600 1000
TCBD157M006CSZ0723 D 150 6.3 125 90 6 40 3 2400 1700 1100 600 1000
10 Volt
TCBD686M010CSZ0700 D 68 10 125 68 6 70 3 1800 1300 800 500 1000
TCBD686M010CSZ0723 D 68 10 125 68 6 70 3 1800 1300 800 500 1000
TCBD107M010CSZ0700 D 100 10 125 100 6 70 3 1800 1300 800 500 1000
TCBD107M010CSZ0723 D 100 10 125 100 6 70 3 1800 1300 800 500 1000
16 Volt
TCBD336M016CSZ0700 D 33 16 125 52 6 70 3 1800 1300 800 500 1000
TCBD336M016CSZ0723 D 33 16 125 52 6 70 3 1800 1300 800 500 1000
TCBD476M016CSZ0700 D 47 16 125 75 6 70 3 1800 1300 800 500 1000
TCBD476M016CSZ0723 D 47 16 125 75 6 70 3 1800 1300 800 500 1000
20 Volt
TCBD226M020CSZ0700 D 22 20 125 44 8 70 3 1800 1300 800 500 1000
TCBD226M020CSZ0723 D 22 20 125 44 8 70 3 1800 1300 800 500 1000
25 Volt
TCBD156M025CSZ0700 D 15 25 125 37 8 70 3 1800 1300 800 500 1000
TCBD156M025CSZ0723 D 15 25 125 37 8 70 3 1800 1300 800 500 1000
35 Volt
TCBD106M035CSZ0700 D 10 35 125 35 8 70 3 1800 1300 800 500 1000
TCBD106M035CSZ0723 D 10 35 125 35 8 70 3 1800 1300 800 500 1000
50 Volt
TCBD106M050CSZ0700 D 10 50 125 50 10 120 3 1400 1000 600 400 500
TCBD106M050CSZ0723 D 10 50 125 50 10 120 3 1400 1000 600 400 500
Moisture Sensitivity Level (MSL) is defined according to J-STD-020.
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts.
DCL is measured at rated voltage after 5 minutes.
ESR allowed to move up to 1.25 times catalog limit post mounting.
NOTE: AVX reserves the rights to supply higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
RECOMMENDED DERATING FACTOR
Voltage and temperature der-
ating as percentage of Vr.
For Vr ≤ 10V For Vr ≥ 16V
Recommended
Application Voltage
100%
95%
90%
85%
80%
75%
70%
65%
60%
55%
50%
-55% 85ºC 105ºC 125ºC
67%
60%
Recommended
Application Voltage
Rated VoltageRated Voltage
100%
95%
90%
85%
80%
75%
70%
65%
60%
55%
50%
-55% 85ºC 105ºC 125ºC
67%
54%
Rated Operating Temperature
voltage ≤85°C 105°C 125°C
≤10V 90% 90% 60%
≥16V 80% 80% 54%
91
110916
TCB Series
COTS-Plus Polymer Capacitor
TEST TCB series (Temperature range -55ºC to +125ºC)
Condition Characteristics
Visual examination no visible damage
DCL 1.25 x initial limit
ΔC/C within +20/-30% of initial value
DF 1.5 x initial limit
ESR 2 x initial limit
Visual examination no visible damage
DCL 2 x initial limit
125ºC, 0V, 2000h ΔC/C within ±20% of initial value
DF 1.5 x initial limit
ESR 2 x initial limit
Visual examination no visible damage
DCL 3 x initial limit
ΔC/C within +30/-20% of initial value
DF 1.5 x initial limit
ESR 2 x initial limit
+20ºC -55ºC +20ºC +85ºC +125ºC +20ºC
DCL
IL* n/a IL* 10 x IL* 12.5 x IL* IL*
ΔC/C
n/a +0/-20% ±5% +20/-0% +30/-0% ±5%
DF
IL* 1.5 x IL* IL* 1.5 x IL* 2 x IL* IL*
Visual examination no visible damage
DCL initial limit
ΔC/C within +20/-30% of initial value
DF 1.25 x initial limit
ESR 1.25 x initial Limit
Visual examination no visible damage
DCL initial limit
ΔC/C within ±10% of initial value
DF initial limit
ESR 1.25 x initial Limit
Determine after application of rated voltage for 2000
+48/-0 hours at 105±2ºC. Also determine after appli-
cation of 125ºC temperature, 2/3 rated voltage for
2000 +48/-0 hours. After test leaving 1-2 hours at
room temperature. Power supply impedance to
be ≤ 0.1Ω/V.
Determine after leaving for 500 or 1000 hours at
85±2ºC, 85% relative humidity and rated voltage
and then recovery 1-2 hours at room temperature.
Test temperature: 125ºC+3/0ºC
Surge voltage: 1.3 x2/3 rated voltage
Charge/Discharge resistance: 1000±100Ω
Number of cycles: 1000x
Cycle duration: 6min; 30sec charge,
5min 30sec discharge
Step Temperature°C Duration(min)
1 +20±2 15
2 -55+0/-3 15
3 +20±2 15
4 +85+3/-0 15
5 +125+3/-0 15
6 +20±2 15
*Initial Limit
For use outside of recommended conditions and special request, please contact manufacturer.
Initial measurement max. 1hr after the removal from dry pack or after pretreatment at 85°C for 24 hours.
QUALIFICATION TABLE
MIL-STD-202, Method 213, Condition I,
100 G peak
MIL-STD-202, Method 204, Condition D,
10 Hz to 2,000 Hz, 20 G peak
Mechanical
Shock/Vibration
Surge
Voltage
Temperature
Stability
Biased
Humidity
Storage Life
Endurance