General Description
The MAX1153/MAX1154 are stand-alone, 10-channel (8
external, 2 internal) 10-bit system monitor ADCs with
internal reference. A programmable single-ended/dif-
ferential mux accepts voltage and remote-diode tem-
perature-sensor inputs. These devices independently
monitor the input channels without microprocessor
interaction and generate an interrupt when any variable
exceeds user-defined limits. The MAX1153/MAX1154
configure both high and low limits, as well as the num-
ber of fault cycles allowed, before generating an inter-
rupt. These ADCs can also perform recursive data
averaging for noise reduction. Programmable wait inter-
vals between conversion sequences allow the selection
of the sample rate.
At the maximum sampling rate of 94ksps (auto mode,
single channel enabled), the MAX1153 consumes only
5mW (1.7mA at 3V). AutoShutdownTM reduces supply
current to 190µA at 2ksps and to less than 8µA at 50sps.
Stand-alone operation, combined with ease of use in a
small package (16-pin TSSOP), makes the MAX1153/
MAX1154 ideal for multichannel system-monitoring
applications. Low power consumption also makes
these devices a good fit for hand-held and battery-pow-
ered applications.
Applications
System Supervision
Remote Telecom Networks
Server Farms
Remote Data Loggers
Features
Monitor 10 Signals Without Processor
Intervention
Eight External Channels Programmable as
Temperature or Voltage Monitors
Intelligent Circuitry for Reliable Autonomous
Measurement
Programmable Digital Averaging Filter
Programmable Fault Counter
Precision Measurements
10-Bit Resolution
±0.5 LSB INL, ±0.5 LSB DNL
±0.75°C Temperature Accuracy (typ)
Flexible
Automatic Channel Scan Sequencer with
Programmable Intervals
Programmable Inputs: Single Ended/Differential,
Voltage/Temperature
Programmable Wait State
Internal 2.5V/4.096V Reference
(MAX1153/MAX1154)
Remote Temperature Sensing Up to 10m
(Differential Mode)
Single 3V or 5V Supply Operation
Small 16-Pin TSSOP Package
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
________________________________________________________________
Maxim Integrated Products
1
Selector Guide
19-2839; Rev 1; 6/10
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
Typical Application Circuit appears at end of data sheet.
AutoShutdown is a trademark of Maxim Integrated Products, Inc.
PART INL (LSB) TEMP
ERROR (°C)
SUPPLY
VOLTAGE (V)
MAX1153BEUE+ ±0.5 ±3.0 2.7 to 3.6
MAX1154BEUE+ ±0.5 ±2.5 4.5 to 5.5
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
AIN0
SCLK
CS
DIN
VDD
GND
DOUT
INT
REF
TOP VIEW
MAX1153
MAX1154
TSSOP
AIN1
AIN2
AIN5
AIN3
AIN4
AIN6
AIN7
+
Pin Configuration
Ordering Information
PART TEMP RANGE PIN-PACKAGE
MAX1153BEUE+ -40°C to +8C 16 TSSOP
MAX1154BEUE+ -40°C to +8C 16 TSSOP
+
Denotes a lead(Pb)-free/RoHS-compliant package.
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
VDD to GND .............................................................-0.3V to +6V
Analog Inputs to GND (AIN0–AIN7, REF) ... -0.3V to (VDD + 0.3V)
Digital Inputs to GND (DIN, SCLK, CS) .... -0.3V to (VDD + 0.3V)
Digital Outputs to GND (DOUT, INT) ........ -0.3V to (VDD + 0.3V)
Digital Outputs Sink Current ............................................. 25mA
Maximum Current into Any Pin .......................................... 50mA
Continuous Power Dissipation (TA= +70°C)
16-Pin TSSOP (derate 11.1mW/°C above +70°C) .......889mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
DC ACCURACY
Resolution RES 10 Bits
Integral Nonlinearity (Note 2) INL ±0.5 LSB
Differential Nonlinearity DNL No missing codes overtemperature ±0.5 LSB
Offset Error ±1.0 LSB
External reference ±1.0 LSB
Gain Error (Note 3) Internal reference 2.0 %FSR
Offset Error Tempco ±5 ppm/°C
External reference ±2
Gain and Temperature Coefficient Internal reference ±30 ppm/°C
Channel-to-Channel Offset
Matching ±0.1 LSB
VDD Monitor Accuracy Internal reference ±2.5 %
DYNAMIC ACCURACY
(10kHz sine-wave input, 2.5VP-P (MAX1153), 4.096VP-P (MAX1154), 64ksps, fSCLK = 10MHz, bipolar input mode)
Signal-to-Noise Plus Distortion SINAD 70 dB
Total Harmonic Distortion THD Up to the 5th harmonic -76 dB
Spurious-Free Dynamic Range SFDR 72 dB
Full-Power Bandwidth -3dB point 1 MHz
Full Linear Bandwidth S / (N + D) > 68dB 100 kHz
CONVERSION RATE
Voltage measurement, all ref modes 10.6 11.7
Temp-sensor ref modes 01, 10 46 50.7
Conversion Time (Note 4) tCONV
Temp-sensor ref mode 00 73 80
μs
Single-Channel Throughput Manual trigger, voltage measurement 70 ksps
Power-Up Time tPU Internal reference (Note 5) 40 45 μs
ANALOG INPUT (AIN0AIN7)
Unipolar, single-ended, or differential inputs 0 VREF
Input Voltage Range (Note 6) Bipolar, differential inputs -VREF / 2 +VREF / 2 V
ELECTRICAL CHARACTERISTICS
(VDD = +2.7V to +3.6V (MAX1153), VDD = +4.5V to +5.5V (MAX1154), VREF = +2.5V (MAX1153), VREF = +4.096V (MAX1154), fSCLK
= 10MHz (50% duty cycle), TA= TMIN to TMAX, unless otherwise noted. Typical values are at TA= +25°C.) (Note 1)
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
_______________________________________________________________________________________ 3
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Common-Mode Range Differentially configured inputs 0 VDD V
Common-Mode Rejection Differentially configured inputs,
VCM = 0 to VDD 90 dB
Input Leakage Current On-/off- leakage, VIN = 0 or VDD ±0.1 ±1 μA
Input Capacitance (Note 7) 18 pF
TEMPERATURE MEASUREMENTS
TA = -40°C to +85°C ±1.2 ±3.0
MAX1153 TA = +25°C ±0.7
TA = -40°C to +85°C ±1.2 ±2.5
Internal Sensor Measurement
Error (Note 8)
MAX1154 TA = +25°C ±0.7
°C
TA = -40°C to +85°C ±2
Differential TA = +25°C ±1
TA = -40°C to +85°C ±5
External Sensor Measurement
Error (Note 9)
Single ended TA = +25°C ±2
°C
Differentially configured inputs and
internal sensor 0.1
Temperature Measurement Noise
Single-ended configured, external sensor 0.5
°C
Temperature Resolution 0.5 °C/LSB
Low 4
External Sensor Bias Current High 66
μA
Differentially configured inputs and
internal sensor 0.3
Power-Supply Rejection PSR
Single-ended configured, external sensor 0.1
°C/V
INTERNAL REFERENCE
MAX1153 2.456 2.500 2.544
REF Output Voltage VREF MAX1154 2.456 4.096 4.168
V
REF Temperature Coefficient TCREF 30 ppm/°C
REF Output Resistance 7 k
MAX1153 200 μVRMS
REF Output Noise MAX1154 160 dB
MAX1153 -70 -50 V
REF Power-Supply Rejection MAX1154 -70 -50 μA
EXTERNAL REFERENCE
REF Input Voltage Range VREF 1.0 VDD + 0.05 V
VREF = +2.5V; fSAMPLE = 94ksps 15 40
REF Input Current IREF VREF = +2.5V; fSAMPLE = 0ksps ±1 μA
ELECTRICAL CHARACTERISTICS (continued)
(VDD = +2.7V to +3.6V (MAX1153), VDD = +4.5V to +5.5V (MAX1154), VREF = +2.5V (MAX1153), VREF = +4.096V (MAX1154), fSCLK
= 10MHz (50% duty cycle), TA= TMIN to TMAX, unless otherwise noted. Typical values are at TA= +25°C.) (Note 1)
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(VDD = +2.7V to +3.6V (MAX1153), VDD = +4.5V to +5.5V (MAX1154), VREF = +2.5V (MAX1153), VREF = +4.096V (MAX1154), fSCLK
= 10MHz (50% duty cycle), TA= TMIN to TMAX, unless otherwise noted. Typical values are at TA= +25°C.) (Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
DIGITAL INPUTS (SCLK, DIN, CS)
Input Voltage Low VIL V
DD x 0.3 V
Input Voltage High VIH V
DD x 0.7 V
Input Hysteresis VHYST 200 mV
Input Leakage Current IIN VIN = 0 or VDD ±10 μA
Input Capacitance CIN 2 pF
DIGITAL OUTPUTS (INT, DOUT)
ISINK = 8mA, DOUT 0.5
Output Voltage Low VOL ISINK = 2mA, INT 0.5 V
ISOURCE = 8mA, DOUT VDD - 0.5
Output Voltage High VOH ISOURCE = 2mA, INT VDD - 0.5 V
Tri-State Leakage Current ILCS = VDD ±10 μA
Tri-State Output Capacitance COUT CS = VDD 5 pF
POWER REQUIREMENTS
MAX1153 2.7 3.6
Positive Supply Voltage VDD MAX1154 2.7 5.5
V
MAX1153 internal reference (Note 10) 3.3
MAX1153 internal reference (Note 11) 2.9
MAX1153 internal reference (Note 11) 2.2
MAX1154 internal reference (Note 10) 5.0
MAX1154 internal reference (Note 11) 4.0
MAX1154 internal reference (Note 11) 3.0
mA
Supply Current IDD
Both internal reference, mode 01 (Note 12) 8 μA
MAX1153 480
Full Power-Down Supply Current ISHDN Full power-down state
MAX1154 860
nA
Power-Supply Rejection Ratio PSRR Analog inputs at full scale (Note 13) ±0.4 ±1.6 μA
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
_______________________________________________________________________________________ 5
TIMING CHARACTERISTICS
(VDD = +2.7V to +3.6V (MAX1153), VDD = +4.5V to +5.5V (MAX1154), TA= TMIN to TMAX, unless otherwise noted.) (Note 1) (Figures 1,
2, and 4)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SCLK Clock Period tCP 100 ns
SCLK Pulse Width High Time tCH 45 ns
SCLK Pulse Width Low Time tCL 45 ns
DIN to SCLK Setup Time tDS 25 ns
DIN to SCLK Hold Time tDH 0ns
CS Fall to SCLK Rise Setup tCSS 25 ns
SCLK Rise to CS Rise Hold tCSH 50 ns
SCLK Fall to DOUT Valid tDOV CL = 30pF 50 ns
CS Rise to DOUT Disable tDOD CL = 30pF 40 ns
CS Fall to DOUT Enable tDOE CL = 30pF 40 ns
CS Pulse Width High tCSW 50 ns
Note 1: The devices are 100% tested at TA= +25°C and +85°C. Specification over temperature range is guaranteed by design.
Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the gain and offset errors
have been calibrated.
Note 3: Offset nulled.
Note 4: In reference mode 00, the reference system powers up for each temperature measurement. In reference mode 01, the ref-
erence system powers up once per sequence of channels scanned. If a sample wait <80µs is programmed, the reference
system is on all the time. In reference mode 10, the reference system is on all the time (see Table 7).
Note 5: No external capacitor on REF.
Note 6: The operational input voltage range for each individual input of a differentially configured pair (AIN0–AIN7) is from GND to
VDD. The operational input voltage difference is from -VREF/2 to +VREF/2.
Note 7: See Figure 3 and the Sampling Error vs. Input Source Impedance graph in the
Typical Operating Characteristics
section.
Note 8: Grade A tested at +10°C and +55°C. -20°C to +85°C and -40°C to +85°C specifications guaranteed by design. Grade B
tested at +25°C. TMIN to TMAX specification guaranteed by design.
Note 9: External temperature measurement mode using an MMBT3904 (Diodes Inc.) as a sensor. External temperature sensing
from -40°C to +85°C; MAX1153/MAX1154 held at +25°C.
Note 10: Performing eight single-ended external channels’ temperature measurements, an internal temperature measurement, and
an internal VDD measurement with no sample wait results in a conversion rate of 2ksps per channel.
Note 11: Performing eight single-ended voltage measurements, an internal temperature measurement, and an internal VDD mea-
surement with no sample wait results in a conversion rate of 7ksps per channel.
Note 12: Performing eight single-ended voltage measurements, an internal temperature measurement, and an internal VDD mea-
surement with maximum sample wait results in a conversion rate of 3ksps per channel.
Note 13: Defined as the shift in the code boundary as a result of supply voltage change. VDD = min to max; full-scale input, mea-
sured using external reference.
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
6 _______________________________________________________________________________________
Typical Operating Characteristics
(VDD = +3V, VREF = +2.5V (MAX1153); VDD = +5V, VREF = +4.096V (MAX1154); fSCLK = 10MHz, CREF = 0.1µF, TA= +25°C, unless
otherwise noted.)
INTEGRAL NONLINEARITY
vs. DIGITAL OUTPUT CODE
MAX1153/54 toc01
OUTPUT CODE
INL (LSB)
768512256
-0.40
-0.30
-0.20
-0.10
0
0.10
0.20
0.30
0.40
0.50
-0.50
0 1024
DIFFERENTIAL NONLINEARITY
vs. DIGITAL OUTPUT CODE
MAX1153/54 toc02
OUTPUT CODE
DNL (LSB)
768512256
-0.40
-0.30
-0.20
-0.10
0
0.10
0.20
0.30
0.40
0.50
-0.50
0 1024
INTERNAL REFERENCE VOLTAGE
vs. SUPPLY VOLTAGE
MAX1153/54 toc03
SUPPLY VOLTAGE (V)
INTERNAL REFERENCE VOLTAGE (V)
3.53.43.2 3.32.9 3.0 3.12.8
2.501
2.502
2.503
2.504
2.505
2.506
2.507
2.508
2.509
2.510
2.500
2.7 3.6
MAX1153
INTERNAL REFERENCE VOLTAGE
vs. SUPPLY VOLTAGE
MAX1153/54 toc04
SUPPLY VOLTAGE (V)
INTERNAL REFERENCE VOLTAGE (V)
5.45.35.1 5.24.7 4.8 4.9 5.04.6
4.077
4.079
4.081
4.083
4.085
4.075
4.5 5.5
MAX1154
REFERENCE VOLTAGE
vs. TEMPERATURE
MAX1153/54 toc05
TEMPERATURE (°C)
REFERENCE VOLTAGE (V)
6040200-20
2.496
2.497
2.498
2.499
2.500
2.501
2.502
2.503
2.504
2.505
2.495
-40 80
GRADE A
GRADE B
MAX1153
REFERENCE VOLTAGE
vs. TEMPERATURE
MAX1153/54 toc05b
TEMPERATURE (°C)
REFERENCE VOLTAGE (V)
6040200-20
4.0725
4.0750
4.0775
4.0800
4.0825
4.0850
4.0875
4.0900
4.0700
-40 80
GRADE A
MAX1154
GRADE B
SUPPLY CURRENT
vs. SAMPLE RATE
MAX1153/54 toc06
SAMPLE RATE (kHz)
SUPPLY CURRENT (mA)
1010.10.01
0.01
0.1
1
10
0.001
0.001 100
INTERNAL REFERENCE
(MODE 01) MAX1153
9 TEMPERATURE
CHANNELS AND 1
VOLTAGE CHANNEL
(VDD/2)
9 VOLTAGE
CHANNELS AND
1 TEMPERATURE
CHANNEL
1 VOLTAGE CHANNEL
(VDD/2)
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
_______________________________________________________________________________________
7
Typical Operating Characteristics (continued)
(VDD = +3V, VREF = +2.5V (MAX1153); VDD = +5V, VREF = +4.096V (MAX1154); fSCLK = 10MHz, CREF = 0.1µF, TA= +25°C, unless
otherwise noted.)
SUPPLY CURRENT
vs. SAMPLE RATE
MAX1153/54 toc07
SAMPLE RATE (kHz)
SUPPLY CURRENT (mA)
1010.10.01
0.01
0.1
1
10
0.001
0.001 100
INTERNAL REFERENCE
(MODE 01) MAX1154
9 TEMPERATURE
CHANNELS AND 1
VOLTAGE CHANNEL
(VDD/2)
9 VOLTAGE
CHANNELS AND
1 TEMPERATURE
CHANNEL
1 VOLTAGE CHANNEL
(VDD/2)
SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX1153/54 toc08
SUPPLY VOLTAGE (V)
SUPPLY CURRENT (mA)
5.14.73.1 3.5 3.9 4.3
1.4
1.8
2.2
2.6
3.0
3.4
3.8
4.2
1.0
2.7 5.5
EXTERNAL REFERENCE (MODE 00)
9 VOLTAGE CHANNELS AND
1 TEMPERATURE CHANNEL
1 VOLTAGE CHANNEL
(VDD/2)
9 TEMPERATURE CHANNELS
AND 1 VOLTAGE CHANNEL (VDD/2)
SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX1153/54 toc09
SUPPLY VOLTAGE (V)
SUPPLY CURRENT (mA)
5.14.73.1 3.5 3.9 4.3
1.9
2.3
2.7
3.1
3.5
3.9
4.3
1.5
2.7 5.5
INTERNAL REFERENCE (MODE 01)
9 TEMPERATURE CHANNELS
AND 1 VOLTAGE CHANNEL (VDD/2)
9 VOLTAGE
CHANNELS AND
1 TEMPERATURE
CHANNEL
1 VOLTAGE
CHANNEL (VDD/2)
SUPPLY CURRENT
vs. TEMPERATURE
MAX1153/54 toc10
TEMPERATURE (°C)
SUPPLY CURRENT (mA)
806535 50-10 5 20-25
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
1.6
-40
9 TEMPERATURE CHANNELS AND
1 VOLTAGE CHANNEL (VDD/2)
9 VOLTAGE CHANNELS AND
1 TEMPERATURE CHANNEL
1 VOLTAGE CHANNEL (VDD/2)
INTERNAL REFERENCE (MODE 01) MAX1153
SUPPLY CURRENT
vs. TEMPERATURE
MAX1153/54 toc11
TEMPERATURE (°C)
SUPPLY CURRENT (mA)
806535 50-10 5 20-25
2.5
3.0
4.0
3.5
4.5
5.0
2.0
-40
9 TEMPERATURE CHANNELS AND
1 VOLTAGE CHANNEL (VDD/2)
9 VOLTAGE CHANNELS AND
1 TEMPERATURE CHANNEL
1 VOLTAGE CHANNEL (VDD/2)
INTERNAL REFERENCE (MODE 01) MAX1154
SHUTDOWN SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX1153/54 toc12
SUPPLY VOLTAGE (V)
SHUTDOWN SUPPLY CURRENT (nA)
5.14.74.33.93.53.1
200
300
400
500
600
700
100
2.7 5.5
MAX1153
MAX1154
SHUTDOWN SUPPLY CURRENT
vs. TEMPERATURE
MAX1153/54 toc13
TEMPERATURE (°C)
SHUTDOWN SUPPLY CURRENT (nA)
655035205-10-25
100
200
300
400
500
600
700
0
-40 80
MAX1154
VDD = 5V
MAX1153
VDD = 3V
GAIN AND OFFSET ERROR
vs. SUPPLY VOLTAGE
MAX1153/54 toc14
SUPPLY VOLTAGE (V)
GAIN AND OFFSET ERROR (LSB)
5.14.73.9 4.33.53.1
-0.80
-0.60
-0.40
-0.20
0
0.20
0.40
0.60
0.80
1.00
-1.00
2.7 5.5
SINGLE ENDED
MAX1153
MAX1154
OFFSET ERROR
GAIN ERROR
GAIN ERROR vs. TEMPERATURE
MAX1153/54 toc15
TEMPERATURE (°C)
GAIN ERROR (LSB)
80655035205-10-25
-0.05
0
0.05
0.10
0.15
0.20
0.25
-0.10
-40
UNIPOLAR
DIFFERENTIAL
CONFIGURATION
EXTERNAL
REFERENCE MODE
BIPOLAR DIFFERENTIAL
CONFIGURATION
EXTERNAL REFERENCE
MODE
UNIPOLAR SINGLE-ENDED
CONFIGURATION
EXTERNAL REFERENCE MODE
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
8 _______________________________________________________________________________________
OFFSET ERROR vs. TEMPERATURE
MAX1153/54 toc16
TEMPERATURE (°C)
OFFSET ERROR (LSB)
80655035205-10-25
-0.20
-0.15
-0.10
-0.05
0
0.05
0.10
0.15
0.20
0.25
-0.25
-40
UNIPOLAR
DIFFERENTIAL
CONFIGURATION
EXTERNAL
REFERENCE MODE
BIPOLAR DIFFERENTIAL
CONFIGURATION
EXTERNAL REFERENCE
MODE
UNIPOLAR SINGLE-ENDED
CONFIGURATION
EXTERNAL REFERENCE
MODE
INTERNAL TEMPERATURE SENSOR
TEMPERATURE ERROR
MAX1153/54 toc17
TEMPERATURE (°C)
ERROR (°C)
6040200-20
-0.80
-0.60
-0.40
-0.20
0
0.20
0.40
0.60
0.80
1.00
-1.00
-40 80
MAX1153/MAX1154
GRADE B INTERNAL
SENSOR
GRADE A INTERNAL
SENSOR
EXTERNAL TEMPERATURE SENSOR
TEMPERATURE ERROR
MAX1153/54 toc18
TEMPERATURE (°C)
ERROR (°C)
6040200-20
-1.60
-1.20
-0.80
-0.40
0
0.40
0.80
1.20
1.60
2.00
-2.00
-40 80
MAX1153/MAX1154
EXTERNAL SENSOR,
DIFFERENTIAL INPUT
EXTERNAL SENSOR,
SINGLE-ENDED INPUT
TEMPERATURE ERROR vs. INTERCONNECT
CAPACITANCE (EXTERNAL SENSOR)
MAX1153/54 toc19
INTERCONNECT CAPACITANCE (pF)
TEMPERATURE (°C)
-5
-4
-3
-2
-1
0
1
-6
100 1000
SAMPLING ERROR
vs. INPUT SOURCE IMPEDANCE
MAX1153/54 toc20
SOURCE IMPEDANCE (Ω)
SAMPLING ERROR (LSB)
1000100
-4
-3
-2
-1
0
1
-5
10 10,000
TURN ON THERMAL TRANSIENT,
CONTINUOUS CONVERSION
VDD = 3.0V
MAX1153/54 toc21
TIME (s)
TEMPERATURE SHIFT (°C)
252015105
0
0.125
0.250
0.375
0.500
0.625
-0.125
030
IN A TSSOP SOCKET
SOLDER ON A 2in X 2in PWB
IN AN OIL BATH
EXTERNAL BJT
Typical Operating Characteristics (continued)
(VDD = +3V, VREF = +2.5V (MAX1153); VDD = +5V, VREF = +4.096V (MAX1154); fSCLK = 10MHz, CREF = 0.1µF, TA= +25°C, unless
otherwise noted.)
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
_______________________________________________________________________________________ 9
Pin Description
ACCUMULATOR
INTERNAL TEMP
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
VDD/2
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
AIN0
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
AIN1
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
AIN2
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
AIN3
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
AIN4
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
AIN5
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
AIN6
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
ACCUMULATOR
AIN7
UPPER
THRESHOLD
LOWER
THRESHOLD
CHANNEL
CONFIGURATION
AIN7
AIN6
AIN5
AIN4
AIN3
AIN2
AIN1
VDD
MUX
TEMP
SENSOR
REFERENCE
12-BIT
ADC WITH
T/H
SCAN
AND
CONVERSION
CONTROL
POR POWER
GOOD
INPUT CHANNEL REGISTER
INPUT CONFIGURATION REGISTER
STEP-UP REGISTER
ALARM REGISTER
AVERAGING
DIGITAL
COMPARATOR
SERIAL
INTERFACE
REF
DOUT
DIN
SCLK
INT
CS
MAX1153
MAX1154
Block Diagram
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
10 ______________________________________________________________________________________
DGND
a) VOL TO VOH
CLOAD = 100pF
100μA
DOUT
DGND
VDD
b) HIGH-Z TO VOL AND VOH TO VOL
CLOAD = 100pF
100μA
DOUT
Figure 1. Load Circuits for DOUT Enable Time and SCLK to
DOUT Delay Time
DGND
a) VOH TO HIGH-Z
CLOAD = 100pF
100μA
DOUT
DGND
VDD
b) VOL TO HIGH-Z
CLOAD = 100pF
100μA
DOUT
Figure 2. Load Circuit for DOUT Disable Time
Detailed Description
The MAX1153/MAX1154 are precision-monitoring inte-
grated circuit systems specifically intended for stand-
alone operation. They can monitor diverse types of
inputs, such as those from temperature sensors and
voltage signals from pressure, vibration, and accelera-
tion sensors, and digitize these input signals. The digi-
tal values are then compared to preprogrammed
thresholds and, if the thresholds are exceeded, the
processor is alerted by an interrupt signal. No interac-
tion by the CPU or microcontroller (µC) is required until
one of the programmed limits is exceeded (Figures 3
and 4).
Voltages on all the inputs are converted to 10-bit values
sequentially and stored in the current data registers.
Note that eight of these inputs are external and two are
internal. One of the internal inputs monitors the VDD
voltage supply, while the other monitors the internal IC
temperature. AIN0 to AIN7 can be configured as either
single ended (default) or differential. In addition, these
inputs can be configured for single-ended or differen-
tial temperature measurements. In the temperature
configuration, the device provides the proper bias nec-
essary to measure temperature with a diode-connected
transistor sensor. The user enables which inputs are
measured (both external and internal) and sets the
delay between each sequence of measurements dur-
ing the initial setup of the device.
The values stored in the current data registers are com-
pared to the user-preprogrammed values in the thresh-
old registers (upper and lower thresholds) and, if
exceeded, activate the interrupt output and generate an
alarm condition. If desired, the device can be pro-
grammed to average the results of many measurements
before comparing to the threshold value. This reduces
the sensitivity to external noise in the measured signal.
In addition, the user can set the number of times the
threshold is exceeded (fault cycles) before generating
an interrupt. This feature reduces falsely triggered
alarms caused by undesired, random spurious impulses.
When the fault cycle criterion is exceeded, an alarm
condition is created. The device writes the fault condi-
tion into the alarm register to indicate the alarmed input
channel.
Converter Operation
The MAX1153/MAX1154 ADCs use a fully differential
successive-approximation register (SAR) conversion
technique and an on-chip track-and-hold (T/H) block to
convert temperature and voltage signals into a 10-bit
digital result. Both single-ended and differential config-
urations are supported with a unipolar signal range for
single-ended mode and bipolar or unipolar ranges for
differential mode. Figure 5 shows the equivalent input
circuit for the MAX1153/MAX1154. Configure the input
channels according to Tables 5 and 6 (see the
Input
Configuration Register
section).
In single-ended mode, the positive input (IN+) is con-
nected to the selected input channel and the negative
input (IN-) is connected to GND. In differential mode,
IN+ and IN- are selected from the following pairs:
AIN0/AIN1, AIN2/AIN3, AIN4/AIN5, and AIN6/AIN7.
Once initiated, voltage conversions require 10.6µs (typ)
to complete.
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 11
During the acquisition interval, IN+ and IN- charge both
a positive (CHOLDP) and a negative (CHOLDN) sam-
pling capacitor. After completing the acquisition inter-
val, the T/H switches open, storing an accurate sample
of the differential voltage between IN+ and IN-. This
charge is then transferred to the ADC and converted.
Finally, the conversion result is transferred to the cur-
rent data register.
Temperature conversions require 46µs (typ) and mea-
sure the difference between two sequential voltage
measurements (see the
Temperature Measurement
section for a detailed description).
Fully Differential Track/Hold (T/H)
The T/H acquisition interval begins with the rising edge
of CS (for manually triggered conversions) and is inter-
nally timed to 1.5µs (typ). The accuracy of the input sig-
nal sample is a function of the input signal’s source
impedance and the T/H’s capacitance. In order to
achieve adequate settling of the T/H, limit the signal
source impedance to a maximum of 1kΩ.
Input Bandwidth
The ADC’s input tracking circuitry has a 1MHz small-
signal bandwidth. To avoid high-frequency signals
aliasing into the frequency band of interest, anti-alias
prefiltering of the input signals is recommended.
Analog Input Protection
Internal protection diodes, which clamp the analog
inputs to VDD and GND, allow the channel input pins to
swing from (VGND - 0.3V) to (VDD + 0.3V) without dam-
age. However, for accurate conversions near full scale,
the inputs must not exceed VDD by more than 50mV or
be lower than VGND by 50mV. If the analog input range
must exceed 50mV beyond the supplies, limit the input
current.
Single Ended/Differential
The MAX1153/MAX1154 use a fully differential ADC for
all conversions. Through the input configuration regis-
ter, the analog inputs can be configured for either dif-
ferential or single-ended conversions. When sampling
signal sources close to the MAX1153/MAX1154, single-
ended conversion is generally sufficient. Single-ended
conversions use only one analog input per signal
source, internally referenced to GND.
MUX
AIN 0
VDD
AIN 1
AIN 2
AIN 3
AIN 4
AIN 5
AIN 6
AIN 7
TEMP
SENSE
12-BIT
ADC WITH T/H
DIGITAL
COMPARATOR
INPUT REGISTERS 0–10
CURRENT DATA
UPPER THRESHOLD
LOWER THRESHOLD
# FAULT CYCLES
AVERAGE
CONFIGURATION/
STATUS
REGISTERS
SCAN AND
CONVERSION
CONTROL
SERIAL
INTERFACE
DIN
INT
DOUT
SCLK
CS
Figure 3. Simplified Alarm Block Diagram of the MAX1153/MAX1154
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
12 ______________________________________________________________________________________
IS CHANNEL
ENABLED?
SAMPLE
CHANNEL
AVERAGE
CONVERTED
CHANNEL DATA
IS
AVG DATA
> UPPER?
SAME FAULT
AS PREVIOUS?
RESET FAULT
COUNTER
INCREMENT
FAULT COUNTER
IS
AVG DATA
< LOWER?
INCREMENT
CHANNEL
COUNTER
IS
FAULT CNT
>
FAULT REG?
SET ALARM
REGISTER
NO
YES
CONVERT
CHANNEL
YES
NO
YES
NO
NO
NO
YES
YES
Figure 4. Alarm Flowchart
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 13
In differential mode, the T/H samples the difference
between two analog inputs, eliminating common-mode
DC offsets and noise. See the
Input Configuration
Register
section and Tables 5 and 6 for more details on
configuring the analog inputs.
Unipolar/Bipolar
When performing differential conversions, the input
configuration register (Tables 5 and 6) also selects
between unipolar and bipolar operation. Unipolar mode
sets the differential input range from 0 to VREF. A nega-
tive differential analog input in unipolar mode causes
the digital output code to be zero. Selecting bipolar
mode sets the differential input range to ±VREF/2. The
digital output code is straight binary in unipolar mode
and two’s complement in bipolar mode (see the
Transfer Function
section).
In single-ended mode, the MAX1153/MAX1154 always
operate in unipolar mode. The analog inputs are inter-
nally referenced to GND with a full-scale input range
from 0 to VREF.
Digital Interface
The MAX1153/MAX1154 digital interface consists of
five signals: CS, SCLK, DIN, DOUT, and INT. CS,
SCLK, DIN, and DOUT comprise an SPI™-compatible
serial interface (see the
Serial Digital Interface
section)
.
INT is an independent output that provides an indica-
tion that an alarm has occurred in the system (see the
INT Interrupt Output
section).
Serial Digital Interface
The MAX1153/MAX1154 feature a serial interface com-
patible with SPI, QSPI™, and MICROWIRE™ devices.
For SPI/QSPI, ensure that the CPU serial interface runs
in master mode so it generates the serial clock signal.
Select a serial clock frequency of 10MHz or less, and
set clock polarity (CPOL) and phase (CPHA) in the µP
control registers to the same value, one or zero. The
MAX1153/MAX1154 support operation with SCLK idling
high or low, and thus operate with CPOL = CPHA = 0 or
CPOL = CPHA = 1.
T
T
TT
H
HH
VAZ
VDD
ADC
8-TO-1
DIFFERENTIAL
MUX
TEMP
DIFFERENTIAL INPUT EQUIVALENT INPUT CIRCUIT
TCHOLD
CHOLDP
CHOLDN
T
H
H
VAZ
VDD
ADC
8-TO-1
DIFFERENTIAL
MUX
TEMP
SINGLE-ENDED INPUT EQUIVALENT INPUT CIRCUIT
Figure 5. Single-Ended/Differential Input Equivalent Input Circuit
SPI and QSPI are trademarks of Motorola, Inc.
MICROWIRE is a trademark of National Semiconductor Corp.
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
14 ______________________________________________________________________________________
Clock pulses on SCLK shift data into DIN on the rising
edge of the SCLK and out of DOUT on the falling edge
of SCLK.
Data transfers require a logic low on CS. A high-to-low
transition of CS marks the beginning of a data transfer. A
logic high on CS at any time resets the serial interface.
See Figure 6 and the
Timing Characteristics
table for
detailed serial-interface timing information.
Input Data Format
Serial communications always begin with an 8-bit com-
mand word, serially loaded from DIN. A high-to-low
transition on CS initiates the data input operation. The
command word and the subsequent data bytes (for
write operations) are clocked from DIN into the
MAX1153/MAX1154 on the rising edges of SCLK. The
first rising edge on SCLK, after CS goes low, clocks in
the MSB of the command word (see the
Command
Word
section). The next seven rising edges on SCLK
complete the loading of the command word into the
internal command register. After the 8-bit command
word is entered, transfer 0 to 20 bytes of data, depend-
ing on the command. Table 2 shows the number of
data bytes for each command.
Output Data Format
Output data from the MAX1153/MAX1154 is clocked
onto DOUT on the falling edge of SCLK. Single-ended
and unipolar differential measurements are output in
straight binary MSB first, with two 8-bytes-per-conver-
sion result, with 2 sub-bits and the last 4 bits padded
with zeros. For temperature and bipolar differential volt-
age measurements, the output is two’s complement
binary in the same 2-byte format. The MSB of the out-
put data from a read command transitions at DOUT
after the falling edge of the 8th SCLK clock pulse fol-
lowing the CS high-to-low transition. Table 2 shows the
number of bytes to be read from DOUT for a given read
command.
Command Word
The command word (Table 1) controls all serial com-
munications and configuration of the MAX1153/
MAX1154, providing access to the 44 on-chip registers.
The first 4 MSBs of the command word specify the
command (Table 2), while the last 4 bits provide
address information.
The first rising edge on SCLK, after CS goes low, trans-
fers the command word MSB into DIN. The next seven
rising edges on SCLK shift the remaining 7 bits into the
internal command register (see the
Serial Digital
Interface
section).
tCSS
tDOE
tDS
tDH
tCH
tCL tCP
tDOV tDOD
tCSH
tCSW
SCLK
DIN
DOUT
CS
Figure 6. Detailed Serial Interface Timing Diagram
Table 1. Command Word
Command B3 Command B2 Command B1 Command B0 Address B3 Address B2 Address B1
Address B0
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 15
Manually Triggered Conversion
(Command Code = 0000)
Before beginning a manual conversion, ensure the
scan mode bit in the setup register is zero, because a
logic 1 disables manual conversions. The address bits
in a Manually Triggered Conversion command select
the input channel for conversion (see Table 3). When
performing a differential conversion, use the even chan-
nel address (AIN0, AIN2, AIN4, AIN6); the command is
ignored if odd channel addresses (AIN1, AIN3, AIN5,
AIN7) are used for a differential conversion.
After issuing a Manually Triggered Conversion com-
mand, bring CS high to begin the conversion. To obtain
a correct conversion result, CS must remain high for a
period longer than the reference power-up time (if in
power-down mode) plus the conversion time for the
selected channel-configured conversion type (voltage
or temperature). The conversion’s result can then be
read at DOUT by issuing a Read Current Data Register
for Selected Channel command, addressing the con-
verted channel. See Table 3 for channel addresses.
Table 2. Command Description
Table 3. Channel Address
ADDRESS IN COMMAND INPUT
0000 Internal temperature
0001 VDD
0010 AIN0
0011 AIN1
0100 AIN2
0101 AIN3
0110 AIN4
0111 AIN5
1000 AIN6
1001 AIN7
1010 Reserved
1011 Reserved
1100 Reserved
1101 Reserved
1110 Reserved
1111 Reserved
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
16 ______________________________________________________________________________________
Read Alarm Register
(Command Code 0001)
The Read Alarm Register command, 0001, outputs the
current status of the alarm register (see Table 11). The
address bits in this command are ignored. The alarm
register is 24 bits long and outputs in 3 bytes. Table 12
illustrates the encoding of the alarm register.
After receiving an interrupt, read the alarm register to
determine the source of the interrupt (see the
Alarm
Register
section).
Read Current Data Register for Selected
Channel (Command Code 0010)
The Read Current Data Register for Selected Channel
command, 0010, outputs the data in the current data
register of the selected channel. The address bits fol-
lowing this command select the input channel to be
read (see Table 3). The current data register is a 10-bit
register. It takes 2 bytes to read its value. See the
Output Data Format
and
Current Data Registers
sec-
tions for more details. See Table 3 for channel address-
es. Also, see Figure 7.
Read Current Data Register for All
Channels (Command Code 0011)
The Read Current Data Registers for All Channels com-
mand, 0011, outputs the data in the current data regis-
ters of all 10 channels, starting with the internal
temperature sensor, then the VDD monitor, followed by
AIN0 to AIN7. The address bits following this command
are ignored. It takes 20 bytes to read all of the 10 chan-
nels’ current data registers.
Read Configuration Register for Selected
Channel (Command Code 0100)
The Read Configuration Register for Selected Channel
command, 0100, outputs the configuration data of the
channel selected by the address bits (see Table 3).
The first register that shifts out is the upper threshold
register (2 bytes), followed by the lower threshold regis-
ter (2 bytes), ending with the channel configuration reg-
ister (1 byte), all MSB first. It takes 5 bytes to read all
three registers. See the
Channel Registers
section for
more details.
SCLK
DIN
DOUT
C3 C2 C1 C0 A2 A1 A0
D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
A3
CS
Figure 7. Serial Register Read Timing
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 17
Read Global Configuration Register
(Command Code 0101)
The Read Global Configuration Register command,
0101, outputs the global configuration registers. The
address bits following this command are ignored. When
the MAX1153/MAX1154 receive a Read Global
Configuration Register command, they output 5 bytes
of data: 2 bytes from the channel enable register, 2
bytes from the input configuration register, and 1 byte
from the setup register, all MSB first. See the
Global
Configuration Registers
section for more details.
RESET (Command Code 0111)
The RESET command, 0111, resets the device. This
command returns the MAX1153/MAX1154 to their
power-on reset state, placing the device into shutdown
mode. The address bits in the command are ignored.
See the
Power-Up/Reset Defaults Summary
section for
more details.
Clear Channel Alarm for Selected Channel
(Command Code 1000)
The Clear Channel Alarm command, 1000, clears the
alarm bits in the alarm register and resets the fault
counter for the addressed channel. See the
Alarm
Register
section for more details. See Table 3 for chan-
nel addresses.
Clear Alarm Register for All Channels
(Command Code 1001)
The Clear Alarm Register for All Channels command,
1001, clears the entire alarm register and resets the
fault counters for the internal TEMP sensor, the VDD
monitor, and the AIN0–AIN7 channels. The address bits
in the command are ignored. See the
Alarm Register
section for more details.
Write Current Data Register for Selected
Channel (Command Code 1010)
The Write Current Data Register for Selected Channel
command, 1010, writes to the addressed channel’s cur-
rent data register. This command sets an initial condi-
tion when using the averaging filter option (see the
Averaging
section). This command can also be used
for testing the thresholds, fault counters, and alarm
functions (see Figure 8). See Table 3 for channel
addresses.
Write Current Data Register for All
Channels (Command Code 1011)
The Write Current Data Register for All Channels com-
mand, 1011, writes to the current data registers of all
channels sequentially, starting with the internal temper-
ature sensor, then the VDD monitor, followed by chan-
nels AIN0 to AIN7. The address bits are ignored. Use
this command for testing and setting initial conditions
when using the averaging filter option (see the
Averaging
section).
C3 C2 C1 C0 A2 A1 A0 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
SCLK
DIN
DOUT
A3
CS
Figure 8. Serial Register Write Timing
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
18 ______________________________________________________________________________________
Write-Selected Channel Configuration
Registers (Command Code 1100)
The Write-Selected Channel Configuration Register com-
mand, 1100, writes to the three channel configuration
registers for the addressed channel (see Table 3). The
first register to be written is the upper threshold (2 bytes),
followed by the lower threshold (2 bytes), ending with the
channel configuration register (1 byte), all MSB first.
Writing to the configuration registers resets the alarm reg-
ister bits and the fault counters for the addressed chan-
nel. See the
Channel Registers
section for more details.
Write Global Configuration Registers
(Command Code 1101)
The Write Global Configuration Registers command,
1101, writes to three registers: the channel-enable reg-
ister (2 bytes), the input configuration register (2 bytes),
and the setup register (1 byte). The command address
bits are ignored. See the
Global Configuration
Registers
section for more details.
Global Configuration Registers
The global configuration registers consist of the chan-
nel-enable register, the input configuration register, and
the setup register. These registers hold configuration
data common to all channels.
Channel-Enable Register
The channel-enable register (Table 4) controls which
channels are converted while in automatic scan mode.
The register contents are ignored for manual conver-
sion commands. Each input channel has a correspond-
ing bit in the channel-enable register. A logic high
enables the corresponding analog input channel for
conversion, while a logic low disables it. In differential
configuration, the bits for odd channels are ignored. At
power-up and after a RESET command, the register
contents default to 111111111111b (all channels
enabled).
Input Configuration Register
The input configuration register (Table 5) stores the
configuration code for each channel as a 3-bit per
channel-pair code (see Table 6), selecting from five
input signal configurations: single-ended unipolar volt-
age, single-ended temperature, differential unipolar
voltage, differential bipolar voltage, and differential
temperature. Table 5 shows the input configuration reg-
ister format, and Table 6 shows the 3-bit encoding for
channel configuration. At power-up and after a RESET
command, the register contents defaults to
000000000000b (all inputs single ended).
Table 4. Channel-Enable Register Format
Table 5. Input Configuration Register Format
(MSB)
(LSB)
AIN0 and AIN1 configuration
AIN2 and AIN3 configuration AIN4 and AIN5 configuration
AIN6 and AIN7 configuration
Table 6. Channel Configuration Coding (3 Bits/Channel Pair)
CODE
Differential external temperature sensor, positive input
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
___________________________________________________ 19
Setup Register
The 8-bit setup register (Table 7) holds configuration
data common to all input channels. At power-up and
after a RESET command, this register defaults to
00000000b.
Setup Register: Sample Wait Bits (B7, B6, B5)
These 3 bits in the setup register (Table 8) set the wait
time between conversion scans. The following are
examples of how the MAX1153/MAX1154 begin a sam-
ple sequence (see the
Setup Register: Reference
Selection Bits (B1/B0)
section).
Operating in reference mode 00 (external reference for
voltage conversions, internal reference for temperature
conversions):
1) Convert the first-enabled channel. If this channel is
a temperature measurement, power up the internal
reference (this takes 20µs for each enabled tem-
perature measurement in reference mode 00).
2) Sequence to the next-enabled channel until all
channels have been converted.
3) Wait the sample wait period.
4) Repeat the procedure.
Operating in reference mode 01 (internal reference for all
conversions, can be powered down between scans):
1) Power up the internal reference, if powered down
(this takes 40µs).
2) Convert the first-enabled channel, starting with the
internal temperature sensor, if enabled.
3) Sequence to the next-enabled channel until all
enabled channels have been converted.
4) Wait the sample wait time, and enter internal refer-
ence power-down mode if this period is greater
than 80µs.
5) Repeat the above steps.
Operating in reference mode 10 (internal reference for
all conversions, continuously powered up):
1) Convert the first-enabled channel.
2) Sequence to the next-enabled channel until all
enabled channels have been converted.
3) Wait the sample wait time.
4) Repeat the procedure.
Use the sample wait feature to reduce supply current
when measuring slow-changing analog signals. This
power savings occurs when reference mode 00 or 01 is
used in combination with wait times longer than 80µs.
With reference mode 10 or wait times of less than 80µs,
the internal reference system remains powered up, mini-
mizing any power savings. See the
Computing Data
Throughput
section. Table 8 shows the B7, B6, B5 wait
time encoding.
Setup Register: Interrupt Control (B4, B3)
Bits B3 and B4 in the setup register configure INT and
how it responds to an alarm event (see the
Alarm
Register
section). Table 9 shows the available INT
options.
Table 7. Setup Register Format
Table 8. Wait Time Encoding
B7, B6, B5 WAIT TIME (ms)
000 0
001 0.080
010 0.395
011 1.310
100 4.970
101 19.600
110 78.200
111 312.000
Table 9. Interrupt Control
BIT FUNCTION BIT
STATE INT OPERATION
1 Driven high or low at all times
B4 Output
driver type 0High-Z when inactive, driven (high
or low) when active
1Acti ve hi g h, i nactive = l ow or hi g h - Z
B3 Output
polarity 0Acti ve l ow , i nacti ve = hi g h or hi g h - Z
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
20 ______________________________________________________________________________________
Setup Register: Scan Mode Bit (B2)
The scan mode bit selects between automatic scan-
ning and manual conversion mode.
When set (B2 = 1), the MAX1153/MAX1154 enter auto-
matic scanning mode and convert every enabled chan-
nel starting with the internal temperature sensor,
followed by the VDD monitor, then sequencing through
AIN0 to AIN7.
After converting all the enabled channels, the
MAX1153/MAX1154 enter a wait state set by the sam-
ple wait bits in the setup register. After completing the
sample wait time, the scan cycle repeats.
When B2 = 0, the MAX1153/MAX1154 are in manual
mode and convert only the selected channel after
receiving a Manually Triggered Conversion command
(see the
Manually Triggered Conversion (Command
Code 0000)
section). Whether in automatic scanning
mode or manual mode, a Read Current Data Register
for Selected Channel command outputs the last-com-
pleted conversion result for the addressed channel at
DOUT.
Setup Register: Reference Selection Bits (B1, B0)
The MAX1153/MAX1154 can be used with an internal
or external reference. Select between internal and
external reference modes through bits B1 and B0 of the
setup register (see Table 10).
Alarm Register
The alarm register (Table 11) holds the current alarm sta-
tus for all of the monitored signals. This 24-bit register
can only be read and cleared. The alarm register has 2
bits for each external input channel, 2 for the onboard
temperature sensor, and 2 for the VDD monitor (see
Table 12). At power-up, these bits are logic low, indicat-
ing no alarms at any input. When any bit in the alarm reg-
ister is set, INT becomes active and remains active until
all alarm bits are cleared. After a fault counter exceeds
the set threshold, the alarm register bits for that particular
channel are updated to indicate an alarm.
To clear the interrupt, reset the active alarm bit with the
Clear Alarm Register command, Clear Channel Alarm
command, a RESET command, or by writing a new
configuration to the faulting channel. The alarm register
defaults to 000000 hex.
Table 11 illustrates how the alarm register stores the
information on which channel a fault has occurred. The
alarm code for each bit pair is shown in Table 12.
Channel Registers
Each channel (internal temperature sensor, VDD moni-
tor, and AIN0 to AIN7) has registers to hold the conver-
sion result (current data register) and channel-specific
configuration data. The channel-specific configuration
registers include: the upper threshold register, the
lower threshold register, and the channel configuration
register. In differential mode, only the registers for the
even channel of the differential input pair are used. The
channel-specific configuration registers for the odd
channel of a differential channel pair are ignored.
Table 10. Reference Selection
B1 B0 REFERENCE MODE
00
Voltage measurements use external reference,
while temperature measurements use the internal
reference. A 20µs reference startup delay is
added prior to each temperature measurement
in this mode. This is the default mode after
power-up and after a software RESET.
01
All measurements use the internal reference. A
40µs reference startup delay is added prior to
starting the scanning of enabled channels,
allowing the internal reference to stabilize.
Note: For sample wait times less than 80µs, the
reference is continuously powered when in
automatic scan mode.
10
All measurements use the internal reference. By
selecting this mode, the reference is powered up
immediately when CS goes high after writing this
configuration. Once the reference system is
powered up, no further delay is added.
1 1 Reserved.
Table 11. Alarm Register Format
B23/B22 B21/B20 B19/B18 B17/B16 B15/B14 B13/B12 B11/B10 B9/B8 B7/B6 B5/B4 B3/B2
B1/B0
TEMP
Table 12. Alarm Register Coding
(2 Bits/Channel)
CODE DESCRIPTION
00 No alarm (power-up state)
01 Input is below lower threshold
10 Input is above upper threshold
00 Reserved
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 21
Channel Configuration Register
Each channel has a channel configuration register (Table
13) defining the number of consecutive faults to be
detected before setting the alarm bits and generating an
interrupt, as well as controlling the digital averaging func-
tion. At power-up and after a RESET command, the regis-
ter defaults to 00 hex (no averaging, alarm on first fault).
Fault Bits
The value stored in the fault bits (B7–B4) in the channel
configuration register sets the number of faults that
must occur for that channel before generating an inter-
rupt. Encoding of the fault bits is straight binary with
values 0 to 15. A fault occurs in a channel when the
value in its current data register is outside the range
defined by the channel’s upper and lower threshold
registers. For example, if the number of faults set by the
fault bits is N, an interrupt is generated when the num-
ber of consecutive faults (see following note) reach
(N + 1). The fault bits default to 0 hex at power-up.
Note: Consecutive faults are those happening in con-
secutive conversion scans for the same channel. If a
fault occurs and the next scan finds the input within the
normal range defined by the thresholds, the fault
counter resets. If the next counter finds the input signal
outside the opposite threshold, rather than the previous
one, the fault counter also resets. The fault counter
increments only when counting consecutive faults
exceeding the same threshold (Figure 4).
Averaging
The averaging calculated by the data-acquisition algo-
rithm of the MAX1153/MAX1154 improves the input sig-
nal-to-noise ratio (SNR) by reducing the signal
bandwidth digitally. The formula below describes the
filter implemented in the MAX1153/MAX1154:
current value = [(N - 1) / N] x past value +
[(present value) / N]
where N = number of samples indicated in Table 14.
The averaging bits (B3–B0) in the channel configuration
register can set the N factor to any value in Table 14.
The output of the filter-running algorithm is continuously
available in the current data register. The starting value
used by the algorithm is the initial state of the current
data register. The current data register is reset to mid-
scale (200 hex) at power-up or after a RESET com-
mand, but it can be loaded with a more appropriate
initial value to improve the filter settling time.
At power-up or after a RESET command, the B3–B0
bits of the channel configuration register are set to 0
hex, corresponding to a number of averaged N = 1, no
averaging. See Table 13 and the
Write-Selected
Channel Configuration Registers
section for program-
ming details. See Table 14 for N encoding.
As in all digital filters, truncation can be a cause of sig-
nificant errors. In the MAX1153/MAX1154, 24 bits of
precision are maintained in the digital averaging func-
tions, maintaining a worst-case truncation error of well
below an LSB. The worst-case truncation error in the
MAX1153/MAX1154 is given by the following:
where N = number of conversions averaged.
Therefore, the worst truncation error when averaging
256 samples is 0.01557 LSBs.
worst case truncation error NLSBs- -
=1
16384
Table 13. Channel Configuration Register Format
Table 14. Conversion Average Encoding
CODE N
0000 1, no averaging
0001 2
0010 4
0011 8
0100 16
0101 32
0110 64
0111 128
1000 256
1001 512
1010 1024
1011 2048
1100 Reserved
1101 Reserved
1110 Reserved
1111 Reserved
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
22 ______________________________________________________________________________________
Upper Threshold Register
A conversion result greater than the value stored in the
upper threshold register results in a fault, increasing the
internal fault counter by one. When the fault count
exceeds the value stored in fault bits B7–B4 of the chan-
nel configuration register, the channel’s alarm bits in the
alarm register are set, resulting in an interrupt on INT.
The upper threshold register data format must be the
same as the input channel. When the input channel is
configured for single-ended or differential unipolar volt-
age measurements, data stored in the upper threshold
register is interpreted as straight binary. For input chan-
nels configured for temperature measurements or as
differential bipolar voltage inputs, the upper threshold
register data is interpreted as two’s complement. Load
the register with 3FF hex to disable upper threshold
faults in unipolar mode, and 1FF hex in temperature or
bipolar mode. The power-up/reset default is 3FF hex.
See the
Command Word
section on how to read/write
to the upper threshold registers.
Lower Threshold Register
Conversion results lower than the value stored in the
lower threshold register increment the internal fault
counter. Considerations about channel configuration
register fault bits B7–B4, INT interrupts, and data for-
mat are the same as for the upper threshold register.
Set the register to 200 hex to disable lower threshold
faults in unipolar mode, or to 200 hex in temperature or
bipolar mode. The power-up/reset default is 000 hex.
See the
Command Word
section on how to read/write
to the lower threshold registers.
Current Data Registers
The current data register holds the last conversion
result or the digitally averaged result, when enabled
(see the
Averaging
section). The current data registers
default to 800 hex at power-up/reset and can be read
from and written to through the serial interface. See the
Command Word
section on how to read/write to the
current data registers.
INT Interrupt Output
INT provides an indication that an alarm has occurred
in the system. It can be programmed (see Table 9) to
operate as a push-pull digital output or as an open-
drain output (requiring either a pullup or a pulldown
resistor) for wired-OR interrupt lines. Bits B3 and B4 in
the setup register configure INT and determine its
response to an alarm event.
When an internal fault counter exceeds the threshold
stored in the fault bits (B7–B4) of the corresponding chan-
nel configuration register, the alarm bits for that particular
channel are updated to indicate an alarm. When any bit in
the alarm register is set, the INT output becomes active,
and stays active until all alarm bits are cleared. See the
Alarm Register
section for more information.
Servicing Interrupts at INT
After detecting an interrupt on INT, the µC’s interrupt
routine should first read the alarm register to find the
source of the alarm and reset the alarm bits by using
any of the methods described in the
Alarm Register
section. Then it can continue with any other action
required by the application to react to the alarm.
Note: Multiple alarm conditions can be present. The
INT remains active until all alarm conditions have been
cleared.
Performing Conversions
At power-up or after a RESET command, the
MAX1153/MAX1154 default to shutdown mode with all
channels enabled, set for single-ended voltage mea-
surements, and with the scan mode set to manual. Start
a conversion by issuing a manually triggered conver-
sion command with the address bits of the channel
selected (see the
Manual Conversion
section for more
details) or by setting automatic scan mode. To place
the MAX1153/MAX1154 in automatic scan mode, set
the scan mode bit B2 in the setup register to logic 1.
In automatic scan mode, the MAX1153/MAX1154 con-
vert all enabled channels starting with the internal tem-
perature sensor, followed by the VDD monitor, then by
AIN0 to AIN7. As the scan sequence progresses, the
analog inputs are converted and the resulting values
are stored for each channel into its current data regis-
ter. Once the scan cycle completes, the MAX1153/
MAX1154 wait a period determined by the sample wait
bits (B7, B6, B5) in the setup register and then repeat
the scan cycle.
After configuring the MAX1153/MAX1154 with automat-
ic scan mode enabled, the devices do not require any
intervention from the system µC until an alarm is trig-
gered. All conversion and monitoring functions can
continue running indefinitely.
Manual Conversion
In manual mode (scan mode bit in the setup register
set to zero, the default after power-up/reset), the
MAX1153/MAX1154 convert individual channels with
the Manually Triggered Conversion command. Assuming
that, either by power-up/RESET defaults or by previous
initialization, the channel to be addressed is both
enabled and configured for the type of signal to be
acquired (voltage/temperature, single ended/differen-
tial, or unipolar/bipolar), carry out the following steps to
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 23
execute a manual conversion. See Figure 9 for manual
conversion timing:
1) Disable autoscan (set up register scan mode bit to
zero), if necessary.
2) Pull CS low.
3) Initiate a conversion by issuing a Manually
Triggered Conversion command (0000, followed by
the address bits of the channel to be converted).
4) Pull CS high to start the conversion.
5) Maintain a logic high on CS to allow for reference
power-up (if the reference mode requires it) and
conversion time.
6) Pull CS low.
7) Issue a Read Current Data Register for Selected-
Channel command (0010, followed by the same
address of the channel in the Manually Triggered
Conversion command).
Voltage Measurements
Every voltage measurement (internal VDD or external
input channel) requires 10.6µs to complete. If the inter-
nal reference needs to power up (reference mode =
01), an additional 40µs is required every time the
MAX1153/MAX1154 come out of automatic shutdown
mode after a sample wait period greater than 80µs.
Monitoring VDD
This internal acquisition channel samples and converts
the supply voltage, VDD.
VDD value can be calculated from the digitized data
with the following equation:
The reference voltage must be larger than 1/2VDD for
the operation to work properly. VDD monitoring requires
10.6µs (typ) per measurement.
Temperature Measurement
The MAX1153/MAX1154 perform temperature measure-
ment by measuring the voltage across a diode-con-
nected transistor at two different current levels. The
following equation illustrates the algorithm used for
temperature calculations:
temperature V V x
HIGH LOW
=−
()
q
k
nxln I
I
High
LOW
V x current data register content x V
DD REF
=
21024
(__ _ )
C3 C2 C1 C0 A2 A1 A0
SCLK
DIN
DOUT
C3 C2 C1 C0 A2 A1 A0A3A3
CS
tPU+CONV
Figure 9. Manual Conversion Timing Without Reading Data
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
24 ______________________________________________________________________________________
where:
VHIGH = sensor-diode voltage with high current flowing
(IHIGH)
VLOW = sensor-diode voltage with low current flowing
(ILOW)
q = charge of electron = 1.602 10-19 coulombs
k = Boltzman constant = 1.38 10-23 J/K
n = ideality factor (slightly greater than 1)
The temperature measurement process is fully auto-
mated in the MAX1153/MAX1154. All steps are
sequenced and executed by the MAX1153/MAX1154
each time an input channel (or an input channel pair)
configured for temperature measurement is scanned.
The resulting 10-bit, two’s complement number repre-
sents the sensor temperature in degrees Celsius, with
1 LSB = +0.5°C.
The MAX1153/MAX1154 support both single-ended
and differential temperature measurements.
Applications Information
Setting Up the
MAX1153/MAX1154 Subsystem
The MAX1153/MAX1154 are autonomous subsystems,
requiring only initialization to scan, convert, and monitor
the voltage signals or the temperature sensors con-
nected to their input channels.
For simple applications, using any number of the input
channels and any combination of voltage/temperature
and unipolar/differential, with no interrupt generation
required, use the following intitialization procedure:
Issue a Write Global Configuration Registers com-
mand. This is a single, 5-byte write operation that
configures the input channels, enables the chan-
nels to be used, sets the sample wait time between
scans, configures the interrupt output INT, selects
the reference mode, and starts the automatic scan
mode. See the Write Global Configuration Registers
Command section, Table 2, and Tables 5–10.
Immediately after the global configuration register is
loaded, the MAX1153/MAX1154 begin to update the
current data registers. Acquire conversion data from
the MAX1153/MAX1154 by issuing a command to read
a specific channel with the Read Current Data Register
for Selected Channel command. Read all current data
register at once with the Read Current Data Registers
for All Channels command.
For more complex applications, the monitoring and
interrupt generation features of the MAX1153/MAX1154
require a second step of initialization. Each enabled
channel to be monitored requires configuration using a
Write Configuration Register for Selected Channel com-
mand. Each command is a 5-byte write that sets the
upper and lower fault thresholds, the number of faults for
an alarm before an interrupt is generated, and an aver-
age algorithm parameter if the application requires input
signal filtering.
Applications can read the current data registers and
respond to interrupts signaled by the INT output (see
the
Servicing Interrupts at INT
section).
All the MAX1153/MAX1154 registers can be verified by
reading back written data, including the configuration
registers. This feature is useful for development and
testing (see Table 2).
Power-Up/Reset Defaults Summary
Setup Register Power-Up/Reset Defaults
At initial power-up or after a RESET command, the
setup register resets to 00 hex. Consequently, the
MAX1153/MAX1154 are configured as follows:
Sample wait time is 0µs.
INT output is open drain and outputs an active-low
signal to signify an alarm.
Table 15. Power-Up/Reset Defaults Summary
REGISTER BIT RANGE POWER-UP/RESET STATE COMMENT
Setup B0 to B7 All 0s See Setup Register Power-Up/Reset Defaults
Channel enable B0 to B11 All 1s All channels (int/ext) enabled
Input configuration B0 to B11 All 0s All single-ended voltage inputs
Alarm register B0 to B23 All 0s No alarms set
Channel configuration B0 to B7 All 0s Faults = 0, no averaging
Upper threshold B0 to B9 All 1s All upper thresholds max range
Lower threshold B0 to B9 All 0s All lower thresholds min range
Current data registers B0 to B9 200hex Set at midrange
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 25
Manual conversion mode
External reference for voltage measurements
Channel Enable Register Power-Up/Reset Defaults
At power-on or after a RESET command, the channel
enable register resets to FF hex, enabling all channels:
the internal temperature sensor, the VDD monitor, and
AIN0–AIN7.
Input Configuration Register
Power-Up/Reset Defaults
At power-on or after a RESET command, the input con-
figuration register resets to 00 hex, configuring
AIN0–AIN7 for single-ended voltage measurement.
Alarm Register Power-Up/Reset Defaults
At power-on or after a RESET command, the alarm reg-
ister is reset to 000000 hex, indicating that no alarm
condition exists.
Current Data Register Power-Up/Reset Defaults
At power-on or after a RESET command, each chan-
nel’s current data register is reset to 200 hex.
Upper Threshold Register Power-Up/Reset Defaults
At power-on or after a RESET command, each chan-
nel's upper threshold register is reset to 3FF hex. This
state effectively disables the upper threshold.
Lower Threshold Register Power-Up/Reset Defaults
At power-on or after a RESET command, each chan-
nel's lower threshold register is reset to 000 hex. This
state effectively disables the lower threshold.
Channel Configuration Register
Power-Up/Reset Defaults
At power-on or after a RESET command, each chan-
nel's configuration register is reset to 000 hex, which
configures the fault bits to cause an alarm to occur on
the first overrange or underrange condition and dis-
ables averaging.
Computing Data Throughput
The MAX1153/MAX1154 throughput rate depends on
the number of enabled channels, their configuration
(temperature or voltage), and the reference mode.
Voltage measurements require 10.6µs (typ) to com-
plete, and temperature measurements require 46µs.
Channel pairs configured for differential measurements
count as only one for throughput computation.
The reference system takes 20µs to power up in refer-
ence mode 00 prior to each temperature measurement,
40µs to power up in reference mode 01 after each sam-
ple wait period (if sample wait time > 80µs), and no
power-up time in reference mode 10.
The sampling period is calculated as follows:
tsw = (tpu) + (Nv)tconv[volt] + (Nt)tconv[temp] + twait
where:
tsw = all channels scan sampling period
tpu = reference power-up time
tconv[volt] = voltage-configured channel conversion time
Nv= number of voltage-configured channels
tconv[temp] = temperature-configured channel conver-
sion time
Nt= number of temperature-configured channels
twait = sample wait time
The terms in the previous equation are determined as
shown by the number of enabled channels, the input
channel configuration (voltage vs. temperature), the
sample wait time, and the reference mode. The follow-
ing calculation shows a numeric example:
tsw = 40µs + 8 x 10.6µs + 2 x 46µs + 395µs = 611.8µs
40µs is the time required for the reference to power-
up (reference mode = 00) every time the
MAX1153/MAX1154 come out of automatic shut-
down mode after a sample wait period.
8 x 10.6µs is the time required for seven channels
configured for voltage measurement and the VDD
monitor.
2 x 46µs is the time required for temperature mea-
surement (46µs for each temperature measurement
(internal or external)).
395µs is the sample wait time, set by bits B5, B6,
B7 of the setup register (see Tables 7 and 8).
The MAX1153/MAX1154 use an internal clock for all
conversions. The serial interface clock does not affect
conversion time.
Performing eight single-ended remote channels tem-
perature measurements, an internal temperature mea-
surement, and an internal VDD measurement with a
sample wait time of zero results in an average conver-
sion rate of 24ksps or 2.4ksps per channel.
Performing eight single-ended voltage measurements,
an internal temperature measurement, and an internal
VDD measurement with sample wait time of zero results
in an average conversion rate of 70ksps or 7ksps per
channel.
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
26 ______________________________________________________________________________________
Automatic Reference Shutdown
The MAX1153/MAX1154 enter an automatic shutdown
mode when in reference mode 00 or when the sample
wait is greater than 80µs in reference mode 01. Using
either of these reference modes and a sample wait
period as long as the application allows results in the
lowest power consumption.
Temperature Measurement
The MAX1153/MAX1154 support both single-ended
and differential temperature measurements. The design
decision between the two types of measurements
depends on the desired level of accuracy and on type
and/or number of temperature sensors. The superior
common-mode rejection and lower noise of the differ-
ential mode reduces measurement errors and provides
higher accuracy, while single-ended measurements
require a lower number of connections, resulting in a
simpler implementation and a higher number of moni-
tored points for each MAX1153/MAX1154.
Differential Temperature Measurement
Connect the anode of a diode-connected transistor to
the even input channel and the cathode to the odd
input channel of an input pair configured for differential
temperature measurement (AIN0/AIN1, AIN2/AIN3,
AIN4/AIN5, or AIN6/AIN7). Run the two sensor connec-
tion lines parallel to each other with minimum spacing.
This improves temperature measurement accuracy by
minimizing the differential noise between the two lines,
since they have equal exposure to most sources of
noise. For further improved noise rejection, shield the
two sensor connections by running them between
ground planes, when available.
Configure the MAX1153/MAX1154 inputs for differential
temperature measurement in the input configuration
register (see Tables 9 and 10) and enable the even
channel number in the channel enable register (see
Table 4).
Single-Ended Temperature Measurement
Connect the anode of a diode-connected transistor to
the input channel and the cathode to ground. Choose
ground connections for sensors away from high-current
return paths to avoid the introduction of errors caused by
voltage drops in the board/system ground, which is the
main drawback for single-ended measurements.
Practical options for better accuracy are the use of a
star-configured subsystem ground or a signal ground
plane; to isolate the anode sensor connection trace away
from board and system noise sources; or to shield it with
ground lines and ground planes (when available) to pre-
vent accuracy degradation in the temperature measure-
ments caused by magnetic/electric noise induction.
Configure the MAX1153/MAX1154 input used for single-
ended temperature measurement in the input configura-
tion register (see Tables 9 and 10) and enable the
analog input in the channel-enable register (see Table 4).
Remote Temperature Sensor Selection
Temperature-sensing accuracy depends on having a
good-quality, diode-connected, small-signal transistor
as a sensor. Accuracy has been experimentally verified
for 2N3904-type devices. The transistor must be a
small-signal type with low base resistance. Tight speci-
fications for forward current gain (+50 to +150, for
example) indicate that the manufacturer has good
process controls and that the devices have consistent
VBE characteristics. CPU on-board sensors and other
ICs’ on-board temperature-sensing devices can also
be used (see Table 16 for recommended devices).
Table 16. Remote Sensor Transistor
Manufacturers
MANUFACTURER MODEL NUMBER
Central Semiconductor (USA) CMPT3904
Fairchild Semiconductors (USA) MMBT3904
Motorola (USA) MMBT3904
Rohm Semiconductor (Japan) SST3904
Siemens (Germany) SMB3904
Zetex (England) FMMT3904CT-ND
Diodes Inc. MMBT3904
OUTPUT CODE
FULL-SCALE
TRANSITION
11....111
0
0INPUT VOLTAGE (LSB)
ZS = 0
FS = VREF
11....110
11....101
00....011
00....010
00....001
00....000
213 FS
1 LSB = VREF
1024
FS = 3/2 LSB
Figure 10. Unipolar Transfer Function, Full Scale (FS) = VREF
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 27
Transfer Function
Figure 10 shows the nominal transfer function for sin-
gle-ended or differential unipolar configured inputs,
Figure 11 illustrates the transfer function for differential
bipolar conversions, and Figure 12 shows temperature
conversions. Code transitions occur halfway between
successive-integer LSB values. Output coding is bina-
ry, with 1 LSB = 2.44mV (MAX1153) or 4mV (MAX1154)
for unipolar and bipolar operation, and 1 LSB = +0.5°C
(MAX1153/MAX1154) for temperature measurements.
For unipolar operation, the 0 code level transition is at
[1/2(VREF / 1024)].
The FFF hex level transition is at [1022.5(VREF / 1024)].
1 LSB = VREF / 1024.
Layout, Grounding, and Bypassing
For best performance, use PC boards. Do not use wire-
wrap boards. Board layout should ensure that digital
and analog signal lines are separated from each other.
Do not run analog and digital (especially clock) signals
parallel to one another or run digital lines underneath
the MAX1153/MAX1154 package. High-frequency
noise in the VDD power supply can affect the
MAX1153/MAX1154 performance. Bypass the VDD sup-
ply with a 0.1µF capacitor from VDD to GND close to
the VDD pin. Minimize capacitor lead lengths for best
supply-noise rejection. If the power supply is very
noisy, connect a 10Ωresistor in series with the supply
to improve power-supply filtering.
Definitions
Integral Nonlinearity
Integral nonlinearity is the deviation of the values on the
actual transfer function from a straight line. This straight
line can be either a best-straight-line fit or a line drawn
between the end points of the transfer function, once off-
set and gain errors have been corrected. The static lineari-
ty parameters for the MAX1153/MAX1154 are measured
using the end-point-fit method. INL is specified as the
maximum deviation in LSBs.
Differential Nonlinearity (DNL)
Differential nonlinearity is the difference between an
actual step width and the ideal value of 1 LSB. A DNL
error specification of less than 1 LSB guarantees no
missing codes and a monotonic transfer function.
Offset Error
The offset error is the difference between the ideal and
the actual analog input value at the first transition of the
ADC, usually from digital code 0 to code 1 for straight
binary output. For the MAX1153/MAX1154, the transi-
tion between code 0 and code 1 should occur at an
input voltage of 1/2 LSB, or 1.22mV for the MAX1153
and 2mV for the MAX1154.
OUTPUT CODE
011....111
TEMPERATURE °C
011....110
000....001
111....101
100....001
100....000
111....111
111....110
000....000
0
000....010
-256°C +255.5°C
Figure 12. Temperature Transfer Function
OUTPUT CODE
011....111
INPUT VOLTAGE (LSB)
011....110
000....001
111....101
100....001
100....000
111....111
111....110
000....000
0
000....010
-FS +FS - 1 LSB
FS =
ZS = 0
VREF
2
-FS = -VREF
2
1 LSB = VREF
1024
Figure 11. Bipolar Transfer Function, Full Scale (±FS) = ±VREF/2
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
28 ______________________________________________________________________________________
Gain Error
The gain error is the difference between the ideal and
actual value of the analog input difference between the
first and last transitions of the ADC output. The first
transition is from digital code 0 to code 1, and the last
from code (2N-2) to code (2N-1), where N = number of
ADC bits for straight binary output code. For the
MAX1153/MAX1154, the ideal difference in the input
voltage between code transitions 0 to 1 and code tran-
sitions 1022 to 1023 is 1022 x LSB. For the MAX1153,
this is 2.5V - 2 x LSB = 2.495117, and for the MAX1154,
this is 4.096V - 2 x LSB = 4.088. Gain error is a DC
specification, usually normalized to the FS ideal analog
value and given in percent of FSR or ppm.
Signal-to-Noise Ratio
For a waveform perfectly reconstructed from digital
samples, signal-to-noise ratio (SNR) is the ratio of the
full-scale analog input (RMS value) to the RMS quantiza-
tion error (residual error). The ideal theoretical minimum
analog-to-digital noise is caused by quantization error
only, results directly from the ADC’s resolution (N bits),
and can be calculated with the following equation:
SNR = (6.02 x N + 1.76)dB
There are other noise sources besides quantization
noise, including thermal noise, reference noise, clock
jitter, etc. Therefore, SNR is calculated by taking the
ratio of the RMS signal to the RMS noise, which
includes all spectral components minus the fundamen-
tal, the first five harmonics, and the DC offset.
Signal-to-Noise Plus Distortion
Signal-to-noise plus distortion (SINAD) is the ratio of the
fundamental input frequency’s RMS amplitude to the
RMS equivalent of all other ADC output signals:
SINAD (dB) = 20 x log (SignalRMS / NoiseRMS)
There are other noise sources besides quantization
noise, including thermal noise, reference noise, clock
jitter, etc. Therefore, SINAD is calculated by taking the
ratio of the full-scale signal to the RMS noise, which
includes all spectral components minus the fundamen-
tal and the first five harmonics.
Total Harmonic Distortion (THD)
Total harmonic distortion (THD) is the ratio of the RMS
sum of the first five harmonics of the input signal to the
fundamental itself. This is expressed as:
where V1is the fundamental RMS value, and V2
through V5are the RMS values of the 2nd- through 5th-
order harmonics, respectively.
Power-Supply Rejection
Power-supply rejection is the ratio between the change
in the ADC full-scale output to the change in power-
supply voltage when the power-supply voltage is varied
from its nominal value. It is specified in V/V or µV/V.
THD x
VVV V
V
log
=
+++
()
20
22324252
1
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
______________________________________________________________________________________ 29
REFERENCE
TEMP
SENSOR
MUX
DIGITAL BLOCK
CHANNEL REGISTERS
GLOBAL REGISTERS
SPI
INTERFACE
μC
VREF
INT
SPI I/F
GND
VDD
+V
48V
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
REMOTE TEMP
ADC
POWER SUPPLY
-5V +5V +3V
MAX1153
MAX1154
Typical Operating Circuit
Chip Information
PROCESS: BiCMOS
Package Information
For the latest package outline information and land patterns, go
to www.maxim-ic.com/packages. Note that a “+”, “#”, or “-” in
the package code indicates RoHS status only. Package draw-
ings may show a different suffix character, but the drawing per-
tains to the package regardless of RoHS status.
PACKAGE TYPE PACKAGE CODE DOCUMENT NO.
16 TSSOP U16-1 21-0066
MAX1153/MAX1154
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
30
____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2010 Maxim Integrated Products Maxim is a registered trademark of Maxim Integrated Products.
Revision History
REVISION
NUMBER
REVISION
DATE DESCRIPTION PAGES
CHANGED
0 4/03 Initial release
1 6/10
Changed voltage characteristics in Electrical Characteristics table, removed
A grade parts, and updated specifications
2–9, 11, 15, 18,
21, 22, 25, 29