www.recom-power.com REV.: 3/2018 PB-9
DC/DC Converter
Specifications (measured @ Ta = 25°C, nom. Vin (110V), full load and after warm-up unless otherwise stated)
RPA100H-RUW
Series
Fire hazard testing - Part 11-10: Test flames - 50W horizontal and vertical
flame test methods Vertical Flame Test
EN60695-11-10: 2013, HL1, HL2, HL3, V-0
Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods;
Glow-wire flammability test method for end-products
Glow-Wire Flammability Test
30s ta, 850°C EN60695-2-11:2000, HL1, HL2, HL3
Plastics - Determination of burning behaviour by oxygen index -
Part 2: Ambient-temperature test
OI% (min) 42.6%
OI% (min) 36.8%
EN ISO 4589-2:2006, HL1, HL2, HL3
EN ISO 4589-2:1999 + A1:2006, HL1, HL2, HL3
Railway Applications - Electrical Equipment used on rolling stock EN50155:2007
Railway applications - Fire protection on railway vehicles
Part 2: Requirements for fire behaviour of materials and components EN45545-2:2013 + A1:2015
EAC RU-AT.49.09571 TP TC 004/2011
RoHS 2+ RoHS 2011/65/EU + AM2015/863
EMC Compliance Condition Standard / Criterion
Railway applications - Electromagnetic compatibility -
Part 3-2: Rolling stock - Apparatus with external components EN50121-3-2:2015
ESD Electrostatic discharge immunity test Air ±8kV, Contact ±6kV EN61000-4-2, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test
80-1000MHz, 20V/m
800-1000MHz, 20V/m
1400-2100MHz, 10V/m
2100-2500MHz, 5V/m
EN61000-4-3, Criteria A
Fast Transient and Burst Immunity ±2kV EN61000-4-4, Criteria A
Surge Immunity ±1kV (diff), ±2kV (com) EN61000-4-5, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields 10V EN61000-4-6, Criteria A
Electromagnetic compatibility of multimedia equipment - Emission
requirements with external components EN55032, Class B
continued on next page
EMC Filtering according to EN50121-3-2
C1 C4 C11 C12
C13 C14
4
5 6
7
8
9
10
3
2
1
C2
C3
+VIN
-VIN
LOAD
L1
EN55022
C5 C7
C8 C10
C9
C6
L2
C15
C16
C19
C20
C17
C18
C21
C22
Fuse
C2
C1 C6 C7 C8
C10
C9
4
5 6
7
8
9
10
3
2
1
C3
MOV
C4
C5
+VIN
-VIN
LOAD
MOV C1 C2, C3, C4, C5 L1 C6, C7 C8 C9, C10
EPCOS
B72207S0131K101
100nF
275VAC 1000pF, 300VAC 1mH
CMC
0.47µF
250V
100µF
200V
120µF