MSP-100 100W Single Output Medical Type series Features : Universal AC input / Full range Built-in active PFC function High efficiency up to 90% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Protections: Over temperature (optional) Cooling by free air convection 1U low profile 38mm Medical safety approved (MOOP level) Built-in remote ON-OFF control No load power consumption<0.5W All using 105 long life electrolytic capacitors 5 years warranty SPECIFICATION MODEL OUTPUT MSP-100-3.3 MSP-100-5 MSP-100-7.5 MSP-100-12 MSP-100-15 MSP-100-24 MSP-100-36 MSP-100-48 DC VOLTAGE 3.3V 5V RATED CURRENT 20A 17A 7.5V 12V 15V 24V 36V 48V 13.5A 8.5A 7A 4.5A 2.9A CURRENT RANGE 0 ~ 20A 2.2A 0 ~ 17A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.9A RATED POWER 66W 0 ~ 2.2A 85W 101.3W 102W 105W 108W 104.4W 105.6W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.8V +2.5,-3.5% 7.1 ~ 9V 2.5% 11.4 ~ 13.8V 1.5% 14.25 ~ 18V 1.5% 22.8 ~ 28.8V 1.5% 34.2 ~ 39.6V 1.5% 45.6 ~ 55.2V 1.5% 3.1 ~ 3.8V VOLTAGE TOLERANCE Note.3 +2.5,-3.5% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 2.0% 2.0% 1.5% 0.8% 0.8% 0.5% 0.5% 0.5% SETUP, RISE TIME 2500ms, 100ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC 88% 88.5% 89% 90% Note.5 85 ~ 264VAC VOLTAGE RANGE 47 ~ 63Hz FREQUENCY RANGE INPUT PF>0.95/230VAC EFFICIENCY (Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.2A/115VAC 35A/115VAC FUNCTION PF>0.98/115VAC at full load 83% 84% 87.5% 0.6A/230VAC 65A/230VAC Note.6 Earth leakage current < 300A/264VAC , Touch leakage current < 100A/264VAC OVERLOAD PROTECTION 120 ~ 370VDC POWER FACTOR (Typ.) LEAKAGE CURRENT 2500ms, 100ms/115VAC at full load 20ms/115VAC at full load OVER VOLTAGE 105 ~ 135% rated output power Protection type : Constant current limiting for Vo=50 ~ 100% of rated voltage, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE REMOTE CONTROL Shut down o/p voltage, recovers automatically after temperature goes down RC+/RC- : 0 ~ 0.8V= power on ; 4 ~ 10V = power off WORKING TEMP. -40 ~ +60 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH 0.04%/ (0 ~ 50) TEMP. COEFFICIENT VIBRATION SAFETY & EMC (Note 4) OTHERS NOTE SAFETY STANDARDS ISOLATION LEVEL 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1, IEC60601-1, EAC TP TC 004 approved Primary-Secondary: 2xMOOP, Primary-Earth: 1xMOOP, Secondary-Earth: 1xMOOP WITHSTAND VOLTAGE I/P-O/P:4KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2, EAC TP TC 020 MTBF 295.7K hrs min. DIMENSION 159*97*38mm (L*W*H) PACKING 0.38Kg; 24pcs/10.1Kg/0.9CUFT I/P-FG:2KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Touch current was measured from primary input to DC output. 7. When the input voltage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this deviation that does not affect basic safety or essential performance. 8. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:MSP-100-SPEC 2020-10-20 MSP-100 100W Single Output Medical Type I I Mechanical Specification Case No.901I series Unit:mm 3.5 7 152.5 1 3 8.2 5 2-M 6 3L 84.5 4 =4 97 65 9.5 2 1 2 7 .5 3 4.5 Terminal Pin No. Assignment 78 24 Pin No. Assignment 4,5 DC OUTPUT -V 6,7 DC OUTPUT +V 159 6.5 150 Terminal JST XHP or equivalent JST SXH-001T or equivalent 3.5 6-M3(Both Sides) L=6 22 38 Mating Housing 28.5 18 Assignment RCRC+ .5 Pin No. 1 2 3 10 max. Remote ON/OFF (CN100) : JST B-XH or equivalent 18.5 9 Assignment AC/L AC/N FG 9 Pin No. 1 2 3 CN100 SVR1 117 Block Diagram ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P RECTIFIERS & PFC POWER SWITCHING O.T.P. O.L.P. RECTIFIERS & FILTER +V -V DETECTION CIRCUIT FG PFC CONTROL O.V.P. PWM CONTROL Derating Curve RC+ REMOTE CONTROL RC- Output Derating VS Input Voltage 100 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -40 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:MSP-100-SPEC 2020-10-20