Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm * Long electrical life and high speed switching * Large plug-in terminals for reliable connection * G3RV-D (DC load) models can manage resistive loads of 100 A to 3.0 A * LED indicator for visible operation checking * Convenient quick electrical connections possible with G3RV push-in models and cross bar connectors * Low power consumption for energy savings * G3RV is cUL listed when correct relay is matched with the G3RV Socket Model Number Structure Model Number Legend G3RV-SL - L 1 2 3 4 5 1. Basic Model Name G3RV: Solid State Relay 2. Auxiliary Type Designation SL: Slim Solid State Relay and socket combination 3. Wire Connection 700: Screw Terminals 500: Push-in (screwless) terminals 4. Output voltage specifications A(L): AC Output .. TRIAC * A: with Zero cross function AL: without Zero cross function D: DC Output .. MOS FET 5. Input Voltage (Complete part numbers listed in the SSR and Socket Combinations Chart below) Ordering Information List of Models Classification Plug-in terminals Enclosure rating General-purpose Unsealed Input voltage AC/DC Type of connection Screw terminals Push-in terminals Contact form SPST G3RV-SL700 G3RV-SL500 SSR and Socket Combinations Input voltage Screw terminals 12 VDC G3RV-SL700-D DC12 24 VDC G3RV-SL700-D DC24 24 VAC/DC G3RV-SL700-D AC/DC24 48 VAC/DC G3RV-SL700-A(L) DC12 G3RV-SL500-A(L) DC12 G3RV-SL700-A(L) DC24 G3RV-SL500-A(L) DC24 G3RV-SL700-A(L) AC/DC24 G3RV-SL700-D AC/DC48 G3RV-SL500-D DC24 G3RV-SL500-D AC/DC24 G3RV-SL500-A(L) AC/DC24 G3RV-SL500-D AC/DC48 G3RV-SL700-A(L) AC/DC48 G3RV-SL500-A(L) AC/DC48 G3RV-SL700-A(L) AC110 G3RV-SL500-A(L) AC110 G3RV-SL700-A(L) AC230 G3RV-SL500-A(L) AC230 110 VAC G3RV-SL700-D AC110 230 VAC G3RV-SL700-D AC230 Solid State Relay G3RV Push-in terminals G3RV-SL500-D DC12 LISTED Note: Relay and Socket Combinations are cULus listed. G3RV-SL500-D AC110 G3RV-SL500-D AC230 1 Specifications Specifications Ratings (at an Ambient Temperature of 25C) Input G3RV-SL700/500-A Series Rated voltage Rated current AC 50 Hz DC Must operate voltage Must release voltage Input voltage % of rated voltage 60 Hz 12 VDC --- --- 15 mA 10.8V 24 VDC --- --- 12 mA 21.6V 24 VAC/DC 20 mA 21 mA 11 mA 21.6V 48 VAC/DC 10 mA 11 mA 6 mA 43.2V 110 VAC 7.5 mA 8.2 mA --- 99V 230 VAC 7.3 mA 8.6 mA --- 207V 10% 1V G3RV-SL700/500-AL Series Rated voltage Rated current AC 50 Hz DC Must operate voltage Must release voltage Input voltage % of rated voltage 60 Hz 12 VDC --- --- 15 mA 10.8V 24 VDC --- --- 12 mA 21.6V 24 VAC/DC 20 mA 21 mA 11 mA 21.6V 48 VAC/DC 10 mA 11 mA 6 mA 43.2V 110 VAC 7.5 mA 8.2 mA --- 99V 230 VAC 7.3 mA 8.6 mA --- 207V 10% 1V G3RV-SL700/500-D Series Rated voltage Rated current AC 50 Hz DC Must operate voltage Must release voltage Input voltage % of rated voltage 60 Hz 12 VDC --- --- 8 mA 10.8V 24 VDC --- --- 4.5 mA 21.6V 24 VAC/DC 10.7 mA 11.1 mA 4.3 mA 21.6V 48 VAC/DC 9.6 mA 10.2 mA 6 mA 43.2V 110 VAC 6.8 mA 7.5 mA --- 99V 230 VAC 6.8 mA 8.1 mA --- 207V 10% 1V Output Item 2 G3RV-SL700/500-A(L) G3RV-SL700/500-D Rated load voltage AC100~240V (50/60Hz) DC5~24V Load voltage range AC75~264V (50/60Hz) DC3~26.4V Load current 0.1~2A (Ta=40C) 100A~3A (Ta=40C) Inrush current 30A (60Hz/1cycle) 30A (60Hz/1cycle) Permissible I2t ; Joule Integral (Reference value) 15A2s 9A2s Application load capacity 400W (Output voltage: AC200V) 72W (Output voltage: DC24V) Solid State Relay G3RV Specifications Engineering Data Characteristics G3RV-SL700/500-A G3RV-SL700/500-AL G3RV-SL700/500-D Operate time Item 1/2 of load power source cycle + 1 ms max. 1 ms max. 6 ms max. Release time 40 ms max. 20 ms max. 60 ms max. Output ON voltage drop Leakage current 1.6 V rms max. 0.9 V max. 5 mA max. (at 200 VAC 50/60Hz) 10 A max. (at 24VDC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength AC2500V 50/60 Hz for 1 min between input and output Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.7-mm single amplitude Shock resistance 300m/s2 Ambient temperature Storage: -30~+100C (with no icing or condensation) Operating: -30~+55C (with no icing or condensation) Ambient humidity 45~85%RH Weight Approx. 38 g Pollution degree 2 Degree of protection according to IEC 60529 IP20 Rated Impulse Withstand Voltage 4.0kV / III Load category LC-A DC-12 Overload Current Profile 1.5Ie 1.1Ue 5s ON, 10s OFF, 10cycles Rated insulation Voltage 240V Approved Standards UL 508 (File No. E64562) Model Input ratings Contact ratings G3RV-SL700/500-D Series 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC 24 VDC 3 A (Resistive Load) at 25C G3RV-SL700/500-A(L) Series 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC 240 VAC 2 A (Resistive Load) at 25C IEC/TUV (EN 62314) Input ratings Contact ratings 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC 24 VDC 3 A (Resistive Load) 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC 240 VAC 2 A (Resistive Load) Solid State Relay G3RV 3 Engineering Engineering Data Data Load current derating curves G3RV-SL700/500-A(L) Series Mounting Distance 10mm Mounting Distance 0mm G3RV-SL700/500-D Series Mounting Distance 10mm Mounting Distance 0mm One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) The values shown by the solid line are for non-repetitive inrush currents. G3RV-SL700/500-D Series G3RV-SL700/500-A(L) Series 4 Solid State Relay G3RV Accessories Accessories PLC Interface (for G2RV-SL700 & G3RV-SL700 series only) List of Models Model number P2RVC-8-O-F Description PLC Output Interface for 8x G2RV-SL700 & G3RV-SL700 series PNP - type Connection Ribbon cable connector 10 Pole, IEC603/1 Specifications Input Rated voltage 30 VAC/VDC max. Current capacity 0.5 A per channel 2.0 A total current, power supply terminal Characteristics Ambient temperature Operating: 0 to 55C Storage: - 20 to 85C Overvoltage category III Pollution degree 2 Electrical schematic P2RVC-O-8-F Solid State Relay G3RV 5 Accessories Cables for PLC Interface P2RVC-8-O-F P2RV-4-C 40 pole IDC mounting to Omron PLC CJ1-OD232 Cable to connect CJ1 to 4 x P2RVC-8-O-F List of Models Model number P2RV-4-100C P2RV-4-200C P2RV-4-300C P2RV-4-500C Cable length 1.0 m 2.0 m 3.0 m 5.0 m 4x10 pole IDC mounting to 4 x P2RVC-8-O-F A B A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 0 C B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 0 A D C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 40 Wire Cable length as indictad by model number. @@@ = length in centimeters B C 40 38 36 34 32 30 28 26 22 24 39 37 35 33 31 29 27 25 21 23 20 18 16 14 12 10 8 6 2 4 19 17 15 13 11 9 7 5 1 Split into 4 sections Length = 30 cm 3 D Technical data Control line Diameter cable Operating voltage Continuous current per signal wire AWG26/0.14 mm2, tin-plated copper 10.6 mm (one end splits into 4 sections: A, B, C, D 60 VDC 0.5 A Max. total current, 4 bytes, each 1.0 A Operating temperature range -20C to +50C Test voltage 0.5 KV, 50 Hz, 1 min P2RV-AC Cable, single sided 10 pole IDC connector, to connect to P2RVC-8-O-F List of Models Model number P2RV-A100C P2RV-A200C P2RV-A300C P2RV-A500C 1.0 m Cable length 2.0 m 3.0 m 5.0 m WHITE 9 GREY 8 PURPLE 7 BLUE 6 GREEN 5 YELLOW 4 ORANGE 3 RED 2 BROWN 1 BLACK Technical data Control line Diameter cable Operating voltage Continuous current per signal wire 6 Cable length as indictad by model number. @@@ = length in centimeters Outer isolation removed Length = 30 cm AWG26/0.14 mm2, tin-plated copper 6.8 mm 60 VDC 0.5 A Max. total current 1.0 A Operating temperature range -20C to +50C Test voltage 10 Wire 10 Open end 10 pole IDC mounting to P2RVC-8-O-F 0.5 KV, 50 Hz, 1 min Solid State Relay G3RV Accessories SSR for Maintenance (Replacement SSRs) Model Number Legend G3RV-@ @ @ @ 1 2 3 4 1. Output voltage specifications D: DC Output 2: AC Output 2. Rated Current 02: AC Output 2A 03: DC Output 3A 3. Terminals S: Plug-In 4. Zero cross function Blank: with Zero cross function L: without Zero cross function List of Models Isolation Phototriac Movement indication Yes (Green) Rated input voltage (Socket) DC12V Output Zero cross (SSR) function AC Yes DC24V Rated output load* Model Number 2A at 100 G3RV-202S DC12 to 240VAC G3RV-202S DC24 AC/DC24V G3RV-SL700/500-A AC/DC48 AC110V G3RV-202S DC48 AC230V No DC24V G3RV-202SL DC12 G3RV-SL700/500-AL DC12 G3RV-202SL DC24 G3RV-SL700/500-AL DC12 AC/DC24V G3RV-SL700/500-AL AC/DC24 AC/DC48V G3RV-SL700/500-AL AC/DC48 AC110V G3RV-202SL DC48 G3RV-SL700/500-AL AC110 G3RV-D03SL DC12 G3RV-SL700/500-D DC12 G3RV-D03SL DC24 G3RV-SL700/500-D DC24 G3RV-D03SL DC48 G3RV-SL700/500-D AC/DC48 AC230V DC24V G3RV-SL700/500-AL AC230 DC --- 3A at 5 to 24 VDC AC/DC24V AC/DC48V G3RV-SL700/500-A AC110 G3RV-SL700/500-A AC230 DC12V DC12V G3RV-SL700/500-A DC12 G3RV-SL700/500-A DC24 G3RV-SL700/500-A AC/DC24 AC/DC48V Photocoupler Replacement for G3RV-SL700/500-D AC/DC24 AC110V G3RV-SL700/500-D AC110 AC230V G3RV-SL700/500-D AC230 *different by ambient temperature. Please refer to 4 pages of characteristic data " Load current derating curves" for the details. Solid State Relay G3RV 7 Accessories Cross bars Model Number Legend P2RVM -@ @ 1 2 1. Number of Poles 020: 2 poles 030: 3 poles 040: 4 poles 100: 10 poles 200: 20 poles 2. Color R: Red S: Blue B: Black List of Models Model number Poles Quantity Color P2RVM-020@ 2 60 pcs / box (minimum order) P2RVM-030@ 3 P2RVM-040@ 4 P2RVM-100@ 10 60 pcs / box (minimum order) Red (R) 60 pcs / box (minimum order) Blue (S) 20 pcs / box (minimum order) Black (B) P2RVM-200@ 20 20 pcs / box (minimum order) @ select color: R = Red, S = Blue, B = Black Specification Max current (EN60947-7-1 section 8.3.3 / 1991) 32A Max. Voltage 400 VAC Max. Voltage when cutting Cross-bar without using separation plate or end-bracket 250 VAC Plastic Labels for G2RV/G3RV Sockets Model number R99-15 for G2RV Box quantity 5 sheets x 120 labels = 600 labels (minimum order) Color White Labels (Stickers) for G2RV/G3RV Sockets Model number R99-16 for G2RV 8 Box quantity Color 10 sheets x 484 labels = White 4,840 labels (minimum order) Solid State Relay G3RV Accessories Separating Plates Model number P2RV-S Quantity 50 plates Description Provides isolation between adjacent relays to achieve 400 V isolation. Dimensions Note: All units are in millimeters unless otherwise indicated. Complete Unit G3RV-SL700 Input circuit 106.7 max. 83 70.9 47.2 6.2 max. 26.1 24 V DC Terminal Arrangement/ 35 Internal Connections 92.7 max. (Top View) Five, M2.5 x 6 88.9 Other Input Voltage Terminal Arrangement/ Internal Connections (Top View) 7.1 99.2 12 V DC Terminal Arrangement/ Internal Connections (Top View) Solid State Relay G3RV 9 Dimensions G3RV-SL500 Input circuit 106.7 max. 82.9 69.8 6.2 max. 46 24.6 24 V DC Terminal Arrangement/ Internal Connections 35 97.4 max. (Top View) 88.9 Other Input Voltage Terminal Arrangement/ Internal Connections (Top View) 7.1 99.2 12 V DC Terminal Arrangement/ Internal Connections (Top View) Solid State Relay G3RV-D03SL G3RV-202S(L) Input circuit G3RV-D03SL G3RV-202S(L) Terminal Arrangement/ Internal Connections (Bottom View) 10 Solid State Relay G3RV Installation Installation Tools G3RV-SL700 series: Flat-Blade screwdriver should be used for mounting and / or releasing cables. G3RV-SL500 series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables. Applicable Screwdriver Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) Flat-blade, Parallel-tip 2.5 dia. (3.0 mm max.) Flat-blade, Flared-tip Cannot be used. Examples: FACOM AEF.2.5 x 75E VESSEL No. 9900-(-)2.5 x 75 WAGO 210-119 WIHA 260/2.5 x 40 (AEF. 3 x 75E) (No. 9900-(-)3 x 100) (260/3 x 50) *Chamfering the tip of the driver improves insertion when used as an exclusive tool. Applicable Wires Applicable Wire Sizes G3RV-SL700 Series Box clamp technology Wire type Applicable wire size Stripping length Stranded without ferrules 2 0.5 - 1.5 mm 7 mm Stranded with ferrules and plastic collar 0.5 - 1.5 mm2 7 mm Stranded with ferrules without plastic collar 0.5 - 1.5 mm2 7 mm Solid 0.5 - 1.5 mm2 7 mm G3RV-SL500 Series Push-in technology Wire type Applicable wire size Stripping length Stranded without ferrules 0.5 - 1.5 mm2 12 mm Stranded with ferrules and plastic collar 0.5 - 1.5 mm2 12 mm Stranded with ferrules without plastic collar 0.5 - 1.5 mm2 12 mm 2 12 mm Solid 0.5 - 1.5 mm Tightening torque G3RV-SL700 Series: 0.4Nm Solid State Relay G3RV 11 Installation Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G3RV-SL700 series, 12 mm for a G3RV-SL500 series. G3RV-SL700 7 mm G3RV-SL500 12 mm Fig. 1 Exposed Conductor Length Wiring Procedure for G3RV-SL500 series Screwdriver hole Wire connection hole Wiring Removing Wire Insert the exposed conductor into the connection hole. Insert the specified screwdriver into the release hole. No other tools are required. Removing wire. Note: In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire. Screwdriver should be removed after fully insertion of the wire. Removing screwdriver. 12 Solid State Relay G3RV Precautions Precautions Precautions for Connection * Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. * Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit. * Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks. * If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. * Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly. General Precautions * Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. * Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator. * Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. * Do not pour water or cleansing agents on the product. Doing so may result in electric shock. * Do not use the socket in locations subject to solvents or alkaline chemicals. * Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration. * Do not dispose the product in fire. Removing from Mounting Rail To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below. * Insert the screwdriver along the hole wall as shown below. Screwdriver Solid State Relay G3RV 13 Precautions Definition of Precautionary Information WARNING CAUTION Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. A potentially hazardous situation by misuse, may result in property damage only accident. Handling * Be sure to provide adequate air flow to G3RV. Failure to do so can cause the G3RV to overheat leading to short circuit and burning. * Do not install G3RV Relay with bent terminals into the socket. Doing so could lead to poor electrical connection and hazardous conditions. * Be sure to mount G3RV's with clean hands. Performing mounting with oil stained hands or coated with metal powder could result in hazardous outcomes. Mounting CAUTION Minor hazard by electric shock may occasionally occur. Do not touch the G3RV's terminal (Charging part) while the power supply turned on. The G3RV may occasionally rupture in case of a short circuit. To protect against short-circuit accident, install a protective device, such as a quick-burning fuse or a circuit breaker or the like, on the power supply. Minor hazard by electric shock may occasionally occur. Do not touch the G3RV's main circuit terminals immediately after the power is turned OFF. The internal snubber circuit is charged. * 202S,SL,G3RV-A(L) Type only Minor hazard by burns may occasionally occur. Do not touch the G3RV or the heat sink either while the power supply is ON, or immediately after the power is turned OFF. The G3RV and the heat sink will be hot. Precautions for Safe Use Shipping When shipping the G3RV, be sure to avoid the following: * Conditions where the G3RV is exposed to water. * High ambient temperatures and humidity. * Be sure to mount the G3RV in the specified orientation. Mounting the G3RV in a different orientation could lead to abnormal heat generation causing output elements to short leading to burning. * G3RV's are SSR's and generate heat. Be sure to control ambient temperature in setting where G3RV is used. If mounted in an enclosed space, install a fan to insure G3RV is properly ventilated. * Be sure that the G3RV clicks into place when mounting it to DIN Track. The G3RV may fall if it is not mounted correctly. Wiring * Use a wire an adequate size for current to be applied. Abnormal heating of wire may cause burning. * Do not use any wires with damaged sheaths. These may cause electric shock. * Confirm that wiring to G3RV Socket is not used in pipe or duct for high voltage power supply. Using a wire in pipe or duct connected to high voltage power supply will generate induction causing malfunction or damage. * Be sure to conduct wiring with the power supply turned OFF. Touching the terminals when they are charged may occasionally result in minor electric shock. Using * Select a load within the rated range. Inappropriate load may cause misoperation, trouble or burning. * Select the power supply within the rated frequency range. Inappropriate power frequency may cause misoperation, trouble or burning. * Inadequate packaging Failure to avoid these conditions while shipping G3RV will lead to damage, malfunction, or deterioration. Operating and Storage Locations Do not use or store the G3RV in the locations listed below. Failure to do so may result in damage, malfunction, or deterioration of performance characteristics. * Locations subject to rain or water drops. * Locations subject to exposure to water, or oil, or chemicals. * Locations subject to high temperatures or high humidity. * Locations subject to ambient temperatures outside the range from -30 to +100 centigrade. Precautions for Correct Use G3RV uses electronics parts inside, so that any dropping, vibration, and physical shock beyond the standard level should be prevented. Failure to do so may result in damage, malfunction, or deterioration of performance characteristics. Be sure to use tightening torque of 0.4 N*m for screw terminal G3RV. Failure to do so could result in short circuit failure and burning. Be sure to use proper voltage/current to G3RV input and output terminals. Failure to do so could result in short circuit failure and burning. * Locations subject to relative humidity outside the range 45% to 85%. * Locations subject to corrosive or flammable gases. * Locations subject to dust (especially iron dust) or salts. * Locations subject to barrier. * Locations subject to static electricity or other forms of noise. * Locations subject to strong electromagnetic fields. * Locations subject to possible exposure to radioactivity. 14 Solid State Relay G3RV Safety Precautions Mounting Be aware of air flow Duct Duct Ventllation outlet SSR SSR SSR 60mm min. Air inlet SSR Vertical direction 30mm min. 80mm min. * If the air inlet or outlet has a filter, clean the filter regularly to prevent it from clogging and ensuring efficient flow of air. * Do no locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. * A heat exchanger, if used, should be located in front of the G2RVs to ensure the efficiency of the heat exchanger. * Please monitor the ambient temperature of the G3RV's. The rated load current is measured at 25C ambient temperature. * A G3RV uses semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the G3RVs and thus increase reliability. (Generally, each 10C reduction in temperature will double the expected life.) EMI * This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference. Suitability for Use OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the product. Duct Depth Counter measure(1) The recommended width is 1/2 as large as the depth of SSR or less Duct or air flow obstruction Vertical direction Do not surrounded the SSR with the duct in the depth direction, or otherwise the heat radiation of the S5R will be adversely affected. Air flow Metal base SSR SSR Duct or air flow obstruction Know and observe all prohibitions of use applicable to this product. Duct or air flow obstruction Duct or air flow obstruction The depth of SSR Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Counter measure(2) Duct or air flow obstruction Use a short duct in the depth direction. SSR NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. See also Product catalog for Warranty and Limitation of Liability. Duct or air flow obstruction If the height of the ducts can not be lowered, place the SSR or a metal base so that they are not surrounded by the ducts. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J180-E1-02 Solid State Relay G3RV In the interest of product improvement, specifications are subject to change without notice. 15 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2010.1 16 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Solid State Relay G3RV OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS * Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 www.omron247.com OMRON ARGENTINA * SALES OFFICE Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br OMRON CHILE * SALES OFFICE Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu J180-E1-02B Note: Specifications are subject to change. (c) 2010 Omron Electronics LLC