Classification Enclosure rating Input voltage Type of connection Contact form
SPST
Plug-in terminals General-purpose Unsealed AC/DC Screw terminals G3RV-SL700
Push-in terminals G3RV-SL500
Input voltage Screw terminals Push-in terminals
12 VDC G3RV-SL700-D DC12 G3RV-SL500-D DC12
G3RV-SL700-A(L) DC12 G3RV-SL500-A(L) DC12
24 VDC G3RV-SL700-D DC24 G3RV-SL500-D DC24
G3RV-SL700-A(L) DC24 G3RV-SL500-A(L) DC24
24 VAC/DC G3RV-SL700-D AC/DC24 G3RV-SL500-D AC/DC24
G3RV-SL700-A(L) AC/DC24 G3RV-SL500-A(L) AC/DC24
48 VAC/DC G3RV-SL700-D AC/DC48 G3RV-SL500-D AC/DC48
G3RV-SL700-A(L) AC/DC48 G3RV-SL500-A(L) AC/DC48
110 VAC G3RV-SL700-D AC110 G3RV-SL500-D AC110
G3RV-SL700-A(L) AC110 G3RV-SL500-A(L) AC110
230 VAC G3RV-SL700-D AC230 G3RV-SL500-D AC230
G3RV-SL700-A(L) AC230 G3RV-SL500-A(L) AC230
Note: Relay and Socket Combinations
are cULus listed.
LISTED
Slimmest OMRON plug-in SSR with
maximum width 6.2 mm
Long electrical life and high speed switching
Large plug-in terminals for reliable connection
G3RV-D (DC load) models can manage resistive loads of
100µA to 3.0 A
LED indicator for visible operation checking
Convenient quick electrical connections possible with G3RV
push-in models and cross bar connectors
Low power consumption for energy savings
G3RV is cUL listed when correct relay is matched with the
G3RV Socket
Model Number Structure
Model Number Legend
1. Basic Model Name
G3RV: Solid State Relay
2. Auxiliary Type Designation
SL: Slim Solid State Relay and socket combination
3. Wire Connection 5. Input Voltage
700: Screw Terminals (Complete part numbers listed in the SSR and Socket
500: Push-in (screwless) terminals Combinations Chart below)
4. Output voltage specifications
A(L): AC Output .. TRIAC
*A: with Zero cross function AL: without Zero cross function
D: DC Output .. MOS FET
1 2 3 4 5
G3RV-SL  - L

Solid State Relays
G3RV
2
Specications
Solid State Relay G3RV
2Solid State Relays G3RV
Specifications
Ratings (at an Ambient Temperature of 25°C)
Input
G3RV-SL700/500-A Series
G3RV-SL700/500-AL Series
G3RV-SL700/500-D Series
Output
Rated voltage Rated current Must operate
voltage
Must release
voltage
Input voltage
AC DC % of rated voltage
50 Hz 60 Hz
12 VDC --- --- 15 mA 10.8V 1V ±10%
24 VDC --- --- 12 mA 21.6V
24 VAC/DC 20 mA 21 mA 11 mA 21.6V
48 VAC/DC 10 mA 11 mA 6 mA 43.2V
110 VAC 7.5 mA 8.2 mA --- 99V
230 VAC 7.3 mA 8.6 mA --- 207V
Rated voltage Rated current Must operate
voltage
Must release
voltage
Input voltage
AC DC % of rated voltage
50 Hz 60 Hz
12 VDC --- --- 15 mA 10.8V 1V ±10%
24 VDC --- --- 12 mA 21.6V
24 VAC/DC 20 mA 21 mA 11 mA 21.6V
48 VAC/DC 10 mA 11 mA 6 mA 43.2V
110 VAC 7.5 mA 8.2 mA --- 99V
230 VAC 7.3 mA 8.6 mA --- 207V
Rated voltage Rated current Must operate
voltage
Must release
voltage
Input voltage
AC DC % of rated voltage
50 Hz 60 Hz
12 VDC --- --- 8 mA 10.8V 1V ±10%
24 VDC --- --- 4.5 mA 21.6V
24 VAC/DC 10.7 mA 11.1 mA 4.3 mA 21.6V
48 VAC/DC 9.6 mA 10.2 mA 6 mA 43.2V
110 VAC 6.8 mA 7.5 mA --- 99V
230 VAC 6.8 mA 8.1 mA --- 207V
Item G3RV-SL700/500-A(L) G3RV-SL700/500-D
Rated load voltage AC100~240V (50/60Hz) DC5~24V
Load voltage range AC75~264V (50/60Hz) DC3~26.4V
Load current 0.1~2A (Ta=40°C) 100µA~3A (Ta=40°C)
Inrush current 30A (60Hz/1cycle) 30A (60Hz/1cycle)
Permissible I2t ; Joule Integral
(Reference value)
15A2s 9A2s
Application load capacity 400W
(Output voltage: AC200V)
72W
(Output voltage: DC24V)
Specications
Solid State Relay G3RV
3
Engineering Data
Solid State Relay G3RV
Solid State Relays G3RV 3
Characteristics
Approved Standards
UL 508 (File No. E64562)
IEC/TUV (EN 62314)
Item G3RV-SL700/500-A G3RV-SL700/500-AL G3RV-SL700/500-D
Operate time 1/2 of load power source cycle
+ 1 ms max.
1 ms max. 6 ms max.
Release time 40 ms max. 20 ms max. 60 ms max.
Output ON voltage drop 1.6 V rms max. 0.9 V max.
Leakage current 5 mA max. (at 200 VAC 50/60Hz) 10 µA max. (at 24VDC)
Insulation resistance 100 M min. (at 500 VDC)
Dielectric strength AC2500V 50/60 Hz for 1 min between input and output
Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.7-mm single amplitude
Shock resistance 300m/s2
Ambient temperature Storage: -30~+100°C (with no icing or condensation)
Operating: -30~+55°C (with no icing or condensation)
Ambient humidity 45~85%RH
Weight Approx. 38 g
Pollution degree 2
Degree of protection according
to IEC 60529
IP20
Rated Impulse Withstand
Voltage
4.0kV / III
Load category LC-A DC-12
Overload Current Profile 1.5Ie 1.1Ue
5s ON, 10s OFF, 10cycles
Rated insulation Voltage 240V
Model Input ratings Contact ratings
G3RV-SL700/500-D Series 12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
24 VDC 3 A (Resistive Load) at 25°C
G3RV-SL700/500-A(L) Series 12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
240 VAC 2 A (Resistive Load) at 25°C
Input ratings Contact ratings
12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
24 VDC 3 A (Resistive Load)
12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
240 VAC 2 A (Resistive Load)
Specications
4Solid State Relay G3RV
Engineering Data
4Solid State Relays G3RV
Engineering Data
Load current derating curves
G3RV-SL700/500-A(L) Series
G3RV-SL700/500-D Series
One Cycle Surge Current: Non-repetitive
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
The values shown by the solid line are for non-repetitive inrush currents.
Mounting Distance 10mm Mounting Distance 0mm
Mounting Distance 10mm Mounting Distance 0mm
G3RV-SL700/500-A(L) Series G3RV-SL700/500-D Series
㪈㪇
㪈㪌
㪉㪇
㪉㪌
㪊㪇
㪊㪌
㪈㪇 㪈㪇㪇 㪈㪇㪇㪇
㪜㫅㪼㫉㪾㫀㫑㪼㪻㩷㫋㫀㫄㪼㩷㩿㫄㫊㪀
㪠㫅㫉㫌㫊㪿㩷㪺㫌㫉㫉㪼㫅㫋㩷㩿㪘㪅㩷㪧㪼㪸㫂㪀
5
Solid State Relay G3RV
Accessories
Solid State Relays G3RV 5
Accessories
PLC Interface (for G2RV-SL700 & G3RV-SL700 series only)
List of Models
Specifications
Electrical schematic P2RVC-O-8-F
Model number Description Connection
P2RVC-8-O-F PLC Output Interface for 8x
G2RV-SL700 & G3RV-SL700 series
PNP - type
Ribbon cable connector
10 Pole, IEC603/1
Input Rated voltage 30 VAC/VDC max.
Current capacity 0.5 A per channel
2.0 A total current, power supply terminal
Characteristics Ambient temperature Operating: 0 to 55°C
Storage: 20 to 85°C
Overvoltage category III
Pollution degree 2
6
Cables for PLC Interface P2RVC-8-O-F
P2RV-4-
Cable to connect CJ1 to 4 x P2RVC-8-O-F
List of Models
4x10 pole IDC mounting to 4 x P2RVC-8-O-F
40 pole IDC mounting to Omron PLC CJ1-OD232
Technical data
Model number Cable length
P2RV-4-100C 1.0 m
P2RV-4-200C 2.0 m
P2RV-4-300C 3.0 m
P2RV-4-500C 5.0 m
A
A1 A2 A3 A4 A5 A6 A7 A8 A9 A100 B1 B2 B3 B4 B5 B6 B7 B8 B9 B100 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10
B C D
40 38 36 34 32 30 28 26 22 24 39 37 35 33 31 29 27 25 21 23 20 18 16 14 12 10 8 6 2 4 19 17 15 13 11 9 751 3
Cable length as indictad
by model number.
@@@ = length in centimeters
Split into 4 sections
Length = 30 cm
40 Wire
B
A
D
C
Control line AWG26/0.14 mm2, tin-plated copper
Diameter cable 10.6 mm (one end splits into 4 sections: A, B, C, D
Operating voltage 60 VDC
Continuous current per signal wire 0.5 A
Max. total current, 4 bytes, each 1.0 A
Test voltage 0.5 KV, 50 Hz, 1 min
Operating temperature range –20°C to +50°C
P2RV-AC
C
Cable, single sided 10 pole IDC connector, to connect to P2RVC-8-O-F
10 pole IDC mounting to P2RVC-8-O-F
Technical data
List of Models
Model number Cable length
P2RV-A100C 1.0 m
P2RV-A200C 2.0 m
P2RV-A300C 3.0 m
P2RV-A500C 5.0 m
Cable length as indictad
by model number.
@@@ = length in centimeters
Outer isolation removed
Length = 30 cm
10 Wire
Control line AWG26/0.14 mm2, tin-plated copper
Diameter cable 6.8 mm
Operating voltage 60 VDC
Continuous current per signal wire 0.5 A
Max. total current 1.0 A
Test voltage 0.5 KV, 50 Hz, 1 min
Operating temperature range –20C to +50C
Solid State Relay G3RV
Accessories
7
6Solid State Relays G3RV
SSR for Maintenance (Replacement SSRs)
Model Number Legend
1. Output voltage specifications
D: DC Output
2: AC Output
2. Rated Current
02: AC Output 2A
03: DC Output 3A
3. Terminals
S: Plug-In
4. Zero cross function
Blank: with Zero cross function
L : without Zero cross function
List of Models
*different by ambient temperature.
Please refer to 4 pages of characteristic data “ Load current derating curves” for the details.
1 234
G3RV-@ @ @ @
Isolation Movement
indication
Rated input
voltage
(Socket)
Output
(SSR)
Zero cross
function
Rated
output
load*
Model Number Replacement for
Phototriac Yes (Green) DC12V AC Yes 2A at 100
to 240VAC
G3RV-202S DC12 G3RV-SL700/500-A DC12
DC24V G3RV-202S DC24 G3RV-SL700/500-A DC24
AC/DC24V G3RV-SL700/500-A AC/DC24
AC/DC48V G3RV-SL700/500-A AC/DC48
AC110V G3RV-202S DC48 G3RV-SL700/500-A AC110
AC230V G3RV-SL700/500-A AC230
DC12V No G3RV-202SL DC12 G3RV-SL700/500-AL DC12
DC24V G3RV-202SL DC24 G3RV-SL700/500-AL DC12
AC/DC24V G3RV-SL700/500-AL AC/DC24
AC/DC48V G3RV-SL700/500-AL AC/DC48
AC110V G3RV-202SL DC48 G3RV-SL700/500-AL AC110
AC230V G3RV-SL700/500-AL AC230
Photocoupler DC12V DC --- 3A at 5 to
24 VDC
G3RV-D03SL DC12 G3RV-SL700/500-D DC12
DC24V G3RV-D03SL DC24 G3RV-SL700/500-D DC24
AC/DC24V G3RV-SL700/500-D AC/DC24
AC/DC48V G3RV-D03SL DC48 G3RV-SL700/500-D AC/DC48
AC110V G3RV-SL700/500-D AC110
AC230V G3RV-SL700/500-D AC230
Solid State Relay G3RV
Accessories
8
Accessories
Solid State Relays G3RV 7
Cross bars
Model Number Legend
1. Number of Poles 2. Color
020: 2 poles R: Red
030: 3 poles S: Blue
040: 4 poles B: Black
100: 10 poles
200: 20 poles
List of Models
@ select color: R = Red, S = Blue, B = Black
Specification
Plastic Labels for G2RV/G3RV Sockets
Labels (Stickers) for G2RV/G3RV Sockets
Model number Poles Quantity Color
P2RVM-020@2 60 pcs / box (minimum order)
Red (R)
Blue (S)
Black (B)
P2RVM-030@3 60 pcs / box (minimum order)
P2RVM-040@4 60 pcs / box (minimum order)
P2RVM-100@10 20 pcs / box (minimum order)
P2RVM-200@20 20 pcs / box (minimum order)
Max current
(EN60947-7-1 section 8.3.3 / 1991)
32A
Max. Voltage 400 VAC
Max. Voltage
when cutting Cross-bar without using separation
plate or end-bracket
250 VAC
12
P2RVM -@ @
Model number Box quantity Color
R99-15 for G2RV 5 sheets × 120 labels =
600 labels (minimum order)
White
Model number Box quantity Color
R99-16 for G2RV 10 sheets × 484 labels =
4,840 labels (minimum order)
White
Solid State Relay G3RV
9
Accessories
8Solid State Relays G3RV
Separating Plates
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Complete Unit
G3RV-SL700
Model number Quantity Description
P2RV-S 50 plates Provides isolation between
adjacent relays to achieve
400 V isolation.
Five,
M2.5 × 6
6.2 max.
99.2
7.1
88.9
26.1
47.2
70.9
83
106.7 max.
92.7 max.
35
Input circuit
24 V DC
Terminal Arrangement/
Internal Connections
(Top View)
Other Input Voltage
Terminal Arrangement/
Internal Connections
(Top View)
12 V DC
Terminal Arrangement/
Internal Connections
(Top View)
Solid State Relay G3RVSolid State Relay G3RV
10
Solid State Relays G3RV 9
G3RV-SL500
Solid State Relay
Input circuit
24 V DC
Terminal Arrangement/
Internal Connections
(Top View)
Other Input Voltage
Terminal Arrangement/
Internal Connections
(Top View)
12 V DC
Terminal Arrangement/
Internal Connections
(Top View)
6.2 max.
99.2
88.9 7.1
24.6
46
69.8
82.9
106.7 max.
97.4 max.
35
G3RV-D03SL
G3RV-202S(L)
Input circuit
G3RV-D03SLG3RV-202S(L)
Terminal Arrangement/
Internal Connections
(Bottom View)
Dimensions
Solid State Relay G3RV
11
10 Solid State Relays G3RV
Installation
Tools
G3RV-SL700 series: Flat-Blade screwdriver should be used for mounting and / or releasing cables.
G3RV-SL500 series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables.
Applicable Screwdriver
Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)
Examples: FACOM AEF.2.5 × 75E (AEF. 3 × 75E)
VESSEL No. 9900-(-)2.5 × 75 (No. 9900-(-)3 × 100)
WAGO 210-119
WIHA 260/2.5 × 40 (260/3 × 50)
*Chamfering the tip of the driver improves insertion when used as an exclusive tool.
Applicable Wires
Applicable Wire Sizes
G3RV-SL700 Series
Box clamp technology
G3RV-SL500 Series
Push-in technology
Tightening torque
G3RV-SL700 Series: 0.4Nm
2.5 dia. (3.0 mm max.)
Cannot be used.
Flat-blade, Flared-tip
Flat-blade, Parallel-tip
Wire type Applicable wire size Stripping length
Stranded without ferrules 0.5 - 1.5 mm27 mm
Stranded with ferrules and plastic collar 0.5 - 1.5 mm27 mm
Stranded with ferrules without plastic collar 0.5 - 1.5 mm27 mm
Solid 0.5 - 1.5 mm27 mm
Wire type Applicable wire size Stripping length
Stranded without ferrules 0.5 - 1.5 mm212 mm
Stranded with ferrules and plastic collar 0.5 - 1.5 mm212 mm
Stranded with ferrules without plastic collar 0.5 - 1.5 mm212 mm
Solid 0.5 - 1.5 mm212 mm
Solid State Relay G3RV
Installation
Solid State Relay G3RV
12
Solid State Relays G3RV 11
Wiring
Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G3RV-SL700 series, 12 mm for a
G3RV-SL500 series.
Wiring Procedure for G3RV-SL500 series
Wiring
Insert the exposed conductor into the connection hole.
No other tools are required.
Note: In case of wiring stranded wires without ferrules screwdriver
should be inserted before inserting the wire.
Screwdriver should be removed after fully insertion of the wire.
Removing
Insert the specified screwdriver into the release hole.
Removing wire.
Removing screwdriver.
7 mm
Fig. 1 Exposed Conductor Length
12 mm
G3RV-SL700
G3RV-SL500
Screwdriver hole
Wire connection hole
Wire
Solid State Relay G3RV
Installation
13
12 Solid State Relays G3RV
Precautions
Precautions for Connection
Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
Do not insert the screwdriver at an angle. Doing so may break the
side of socket and result in a short-circuit.
Do not insert two or more wires in the hole. Wires may come in
contact with the spring causing a temperature rise or be subject to
sparks.
Insert the screwdriver along the hole wall as shown below.
If lubricating liquid, such as oil, is present on the tip of screwdriver,
the screwdriver may fall out resulting in injury to the operator.
Insert the screwdriver into the bottom of the hole. It may not be
possible to connect cables properly if the screwdriver is inserted
incorrectly.
General Precautions
Do not use the product if it has been dropped on the ground.
Dropping the product may adversely affect performance.
Confirm that the socket is securely attached to the mounting track
before wiring. If the socket is mounted insecurely it may fall and
injure the operator.
Ensure that the socket is not charged during wiring and
maintenance. Not doing so may result in electric shock.
Do not pour water or cleansing agents on the product. Doing so
may result in electric shock.
Do not use the socket in locations subject to solvents or alkaline
chemicals.
Do not use the socket in locations subject to ultraviolet light (e.g.,
direct sunlight). Doing so may result in markings fading, rust,
corrosion, or resin deterioration.
Do not dispose the product in fire.
Removing from Mounting Rail
To remove the socket from the mounting rail, insert the tip of
screwdriver in the fixture rail, and move it in the direction shown
below.
Screwdriver
Solid State Relay G3RVSolid State Relay G3RV
Precautions
14
Precautions
Solid State Relays G3RV 13
Definition of Precautionary Information
Precautions for Safe Use
Shipping
When shipping the G3RV, be sure to avoid the following:
Conditions where the G3RV is exposed to water.
High ambient temperatures and humidity.
Inadequate packaging
Failure to avoid these conditions while shipping G3RV will lead to
damage, malfunction, or deterioration.
Operating and Storage Locations
Do not use or store the G3RV in the locations listed below. Failure
to do so may result in damage, malfunction, or deterioration of
performance characteristics.
Locations subject to rain or water drops.
Locations subject to exposure to water, or oil, or chemicals.
Locations subject to high temperatures or high humidity.
Locations subject to ambient temperatures outside the range
from -30 to +100 centigrade.
Locations subject to relative humidity outside the range 45% to
85%.
Locations subject to corrosive or flammable gases.
Locations subject to dust (especially iron dust) or salts.
Locations subject to barrier.
Locations subject to static electricity or other forms of noise.
Locations subject to strong electromagnetic fields.
Locations subject to possible exposure to radioactivity.
Handling
Be sure to provide adequate air flow to G3RV. Failure to do so
can cause the G3RV to overheat leading to short circuit and
burning.
Do not install G3RV Relay with bent terminals into the socket.
Doing so could lead to poor electrical connection and hazardous
conditions.
Be sure to mount G3RV's with clean hands. Performing
mounting with oil stained hands or coated with metal powder
could result in hazardous outcomes.
Mounting
Be sure to mount the G3RV in the specified orientation.
Mounting the G3RV in a different orientation could lead to
abnormal heat generation causing output elements to short
leading to burning.
G3RV's are SSR's and generate heat. Be sure to control
ambient temperature in setting where G3RV is used. If mounted
in an enclosed space, install a fan to insure G3RV is properly
ventilated.
Be sure that the G3RV clicks into place when mounting it to DIN
Track. The G3RV may fall if it is not mounted correctly.
Wiring
Use a wire an adequate size for current to be applied. Abnormal
heating of wire may cause burning.
Do not use any wires with damaged sheaths. These may cause
electric shock.
Confirm that wiring to G3RV Socket is not used in pipe or duct
for high voltage power supply. Using a wire in pipe or duct
connected to high voltage power supply will generate induction
causing malfunction or damage.
Be sure to conduct wiring with the power supply turned OFF.
Touching the terminals when they are charged may occasionally
result in minor electric shock.
Using
Select a load within the rated range. Inappropriate load may
cause misoperation, trouble or burning.
Select the power supply within the rated frequency range.
Inappropriate power frequency may cause misoperation, trouble
or burning.
Precautions for Correct Use
G3RV uses electronics parts inside, so that any dropping,
vibration, and physical shock beyond the standard level should be
prevented. Failure to do so may result in damage, malfunction, or
deterioration of performance characteristics.
Be sure to use tightening torque of 0.4 N·m for screw terminal
G3RV. Failure to do so could result in short circuit failure and
burning.
Be sure to use proper voltage/current to G3RV input and output
terminals. Failure to do so could result in short circuit failure and
burning.
WARNING
Indicates a potentially hazardous situation which,
if not avoided, will result in minor or moderate
injury, or may result in serious injury or death.
Additionally there may be significant property
damage.
CAUTION A potentially hazardous situation by misuse, may
result in property damage only accident.
CAUTION
Minor hazard by electric shock may occasionally occur.
Do not touch the G3RV's terminal (Charging part) while
the power supply turned on.
The G3RV may occasionally rupture in case of a short
circuit.
To protect against short-circuit accident, install a
protective device, such as a quick-burning fuse or a
circuit breaker or the like, on the power supply.
Minor hazard by electric shock may occasionally occur.
Do not touch the G3RV's main circuit terminals
immediately after the power is turned OFF.
The internal snubber circuit is charged.
* 202S,SL,G3RV-A(L) Type only
Minor hazard by burns may occasionally occur.
Do not touch the G3RV or the heat sink either while the
power supply is ON, or immediately after the power is
turned OFF.
The G3RV and the heat sink will be hot.
Solid State Relay G3RV
15
Safety Precautions
14 Solid State Relays G3RV
Mounting
<SSR Mounting Pitch (Panel Mounting)>
<Relations between SSR and duct (Depth of duct)>
<Ventilation Outside the Control Panel>
*If the air inlet or outlet has a filter, clean the filter regularly to
prevent it from clogging and ensuring efficient flow of air.
*Do no locate any objects around the air inlet or air outlet, otherwise
the objects may obstruct the proper ventilation of the control panel.
*A heat exchanger, if used, should be located in front of the G2RVs
to ensure the efficiency of the heat exchanger.
*Please monitor the ambient temperature of the G3RV's. The rated
load current is measured at 25°C ambient temperature.
*A G3RV uses semiconductor in the output element.
This causes the temperature inside the control panel to increase
due to heating resulting from the passage of electrical current
through the load. To restrict heating, attach a fan to the
ventilation outlet or air inlet of the control panel to ventilate the
panel. This will reduce the ambient temperature of the G3RVs and
thus increase reliability.
(Generally, each 10°C reduction in temperature will double the
expected life.)
EMI
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take
adequate measures to reduce interference.
Suitability for Use
OMRON shall not be responsible for conformity with any standards,
codes, or regulations that apply to the combination of the products in
the customer's application or use of the product.
Take all necessary steps to determine the suitability of the product
for the systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE
OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Duct
60mm min.
80mm min.
30mm min.
SSR
Vertical
direction
Counter measure(1)Duct Depth Counter measure(2)
Duct or air flow
obstruction
The depth
of SSR
SSR SSR SSR
Vertical
direction
Duct or air flow obstruction Duct or air flow
obstruction
Duct or air flow obstruction
The recommended width is
1/2 as large as the depth of
SSR or less Duct or air flow
obstruction
Air flow
Duct or air flow
obstruction
Do not surrounded the SSR
with the duct in the depth
direction, or otherwise the
heat radiation of the S5R
will be adversely affected.
If the height of the ducts
can not be lowered, place
the SSR or a metal base so
that they are not
surrounded by the ducts.
Use a short duct in
the depth direction.
Metal
base
SSR SSR SSR
Air inlet
Be aware of air flow
Duct
Ventllation
outlet
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J180-E1-02
Solid State Relay G3RVSolid State Relay G3RV
16
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2010.1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2010 All Right Reserved.
Solid State Relay G3RV
Solid State Relay G3RV
J180-E1-02B Note: Specications are subject to change. © 2010 Omron Electronics LLC
OMRON CANADA, INC. • HEAD OFFICE


OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE

OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE

OMRON ARGENTINA • SALES OFFICE

OMRON CHILE • SALES OFFICE

OTHER OMRON LATIN AMERICA SALES

OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS
OMRON EUROpE B.V.
