1N4001
THRU
1N4007
1 Amp Rectifier
50 - 1000 Volts
DO-41
Features
Low Current Leakage
Metalurgically Bonded Construction
Low Cost
DIMENSIONS
INCHES MM
DIM MIN MAX MIN MAX NOTE
A .166 .205 4.10 5.20
B .080 .107 2.00 2.70
C .028 .034 .70 .90
D 1.000 --- 25.40 ---
Maximum Ratings
Operating Temperature: -55°C to +125°C
Storage Temperature: -55°C to +150°C
Typical Thermal Resistance: 25°C/W Junction to Lead at 0.375"
MCC
Catalog
Number
Device
Marking
Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
1N4001 50V 35V 50V
1N4002 1N4002 100V 70V 100V
1N4003 200V 140V 200V
1N4004 400V 280V 400V
1N4005 600V 420V 600V
1N4006 800V 560V 800V
1N4007 1000V 700V 1000V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
IF(AV) 1.0A TA= 75°C
Peak Forward Surge
Current
IFSM 30A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
VF1.1V IFM = 1.0A;
TJ= 25°C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR5.0µA
50µA
TJ= 25°C
TJ= 125°C
Typical Junction
Capacitance
CJ15pF Measured at
1.0MHz, VR=4.0V
*Pulse test: Pulse width 300 µsec, Duty cycle 2%
A
B
C
D
D
Cathode
Mark
20736 Marilla Street Chatsworth

 !"#
$%  !"#
MCC
Revision: 5 2006/06/15
Maximum Reverse
Recovery Time
Trr 2.0usI
F=0.5A, IR=1.0A,
Irr=0.25A
Lead Length P.C.B. Mounted
TM
Micro Commercial Components
Case Material: Molded Plastic. UL Flammability
Classification Rating 94V-0
1N4001
1N4007
1N4003
1N4004
1N4005
1N4006
www.mccsemi.com
1 of 4
Micro Commercial Components
1N4001 thru 1N4007
Average Forward Rectified Current - Amperesversus
Ambient Temperature -°C
Figure 2
Forward Derating Curve
017550 75 100 125
0
.2
.4
.6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
150
.8
1.0
1.2
Junction Capacitance - pF versus
Reverse Voltage - Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
4
6
20
10
Amps
.4 .6 .8 1.0 1.2 1.4
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25°C
Volts
Figure 3
Junction Capacitance
.1 .2 1.4 2 10 20 404 100 200
1
2
6
10
20
100
pF
Volts
60
40
4
400 1000
TJ=25°C
MCC
Revision: 5 2006/06/15
TM
Micro Commercial Components
www.mccsemi.com
2 of 4
1N4001 thru 1N4007
1 100
4
0
10
20
30
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
40
50
60
Figure 4
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Volts
4
6
20
10
µAmps
20 120
40 60 80 100
.01
.02
.04
.06
.1
.2
.4
.6
1
2
TA=25°C
40
60
100
140
TA=100°C
MCC
Revision: 5 2006/06/15
TM
Micro Commercial Components
www.mccsemi.com
3 of 4
MCC
Revision: 5 2006/06/15
TM
Micro Commercial Components
www.mccsemi.com
4 of 4
products are represented on our website, harmless against all damages.
***APPLICATIONS DISCLAIMER***
***IMPORTANT NOTICE***
Aerospace or Military Applications.
Products offer by Micro Commercial Components Corp .are not intended for use in Medical,
Micro Commercial Components Corp .reserves the right to make changes without further notice to any
product herein to make corrections, modifications , enhancements , improvements , or other changes .
Micro Commercial Components Corp .does not assume any liability arising out of the application or
use of any product described herein; neither does it convey any license under its patent rights ,nor
the rights of others . The user of products in such applications shall assume all risks of such use
and will agree to hold Micro Commercial Components Corp .and all the companies whose