Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 502PTZ Composite - For PTZ Cameras: CCTV + Control + Power For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Riser-CMR, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-18 AWG stranded bare copper pair with polyolefin insulation and Beldfoil(R) shield, 2-18 AWG stranded bare copper conductors with polyolefin insulation, Siamese with PVC jacket Coax Physical Characteristics Conductor AWG: # Coax AWG Stranding Conductor Material Dia. (in.) 1 20 Solid BC - Bare Copper 0.032 Insulation Insulation Material: Insulation Material Dia. (in.) Gas-injected FHDPE - Foam High Density Polyethylene 0.145 Outer Shield Outer Shield Material: Type Outer Shield Material Coverage (%) Braid BC - Bare Copper 95.000 Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Outer Jacket Diameter: Nom. Dia. (in.) 0.227 Outer Jacket Color Code Chart: Number Color Video Black Applicable Specifications and Agency Compliance Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMG EU CE Mark: Yes RG Type: 59/U Flame Test UL Flame Test: UL1666 Vertical Shaft Suitability Suitability - Indoor: Yes Electrical Characteristics Nom. Characteristic Impedance: Impedance (Ohm) 75 Nom. Inductance: Inductance (H/ft) 0.097 Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 16.300 Nominal Velocity of Propagation: VP (%) Page 1 of 4 08-26-2016 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 502PTZ Composite - For PTZ Cameras: CCTV + Control + Power 83.000 Nominal Delay: Delay (ns/ft) 1.220 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/1000 ft) 10.000 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/1000 ft) 3.500 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100 ft.) 1.000 0.300 5.000 0.650 10.000 0.900 50.000 1.900 100.000 2.600 200.000 3.600 400.000 5.000 700.000 7.000 900.000 8.000 1000.000 8.500 Max. Operating Voltage - UL: 300 V RMS Twisted Pair Physical Characteristics Conductor AWG: # Pairs AWG Stranding Conductor Material Dia. (in.) 1 18 19x30 BC - Bare Copper 0.044 Insulation Insulation Material: Insulation Material Dia. (in.) PO - Polyolefin 0.080 Twisted Pair Color Code Chart: Number Color 1 Blue and White/Blue Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100.000 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 20 7x28 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Outer Jacket Diameter: Nom. Dia. (in.) 0.219 Outer Jacket Color Code Chart: Number Color 1 Blue Applicable Specifications and Agency Compliance Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMG Flame Test UL Flame Test: UL1666 Vertical Shaft Suitability Suitability - Indoor: Yes Page 2 of 4 08-26-2016 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 502PTZ Composite - For PTZ Cameras: CCTV + Control + Power Suitability - Indoor: Yes Electrical Characteristics Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 44.000 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 26.000 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/1000 ft) 6.500 Max. Operating Voltage - Other: Voltage 300 V RMSl Max. Recommended Current: Description Current Data/Control 5.2 Amps Multi Conductor Physical Characteristics Conductor AWG: # Conductors AWG Stranding Conductor Material Dia. (in.) 2 18 7x26 BC - Bare Copper 0.047 Insulation Insulation Material: Insulation Material PP - Polypropylene Insulation Color Code Chart: Number Color 1 Red 2 Black Individual Shield Outer Jacket Outer Jacket Diameter: Nom. Dia. (in.) 0.158 Outer Jacket Color Code Chart: Number Color 1 White Applicable Specifications and Agency Compliance Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMG Flame Test UL Flame Test: UL1666 Vertical Shaft Suitability Suitability - Indoor: Yes Electrical Characteristics Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 21.500 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/1000 ft) 6.500 Max. Operating Voltage - Other: Voltage 300 V RMS Max. Recommended Current: Current 5 Amps per conductor @ 25C Page 3 of 4 08-26-2016 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 502PTZ Composite - For PTZ Cameras: CCTV + Control + Power Physical Characteristics (Overall) Conductor Outer Jacket Outer Jacket Material: Outer Jacket Material Unjacketed Overall Cable Overall Nominal Diameter: 0.451 in. Mechanical Characteristics (Overall) Operating Temperature Range: -10C To +75C Separation Temperature Range: 0C To +75C Bulk Cable Weight: 74.000 lbs/1000 ft. Max. Recommended Pulling Tension: 140.000 lbs. Min. Bend Radius/Minor Axis: 4.500 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Applicable Patents: Country www.belden.com/p Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 602PTZ Notes (Overall) Notes: RG59 CCTV + 1 STP18 AWG Control Grade + 2C 18 AWG CMR. Individually jacketed and color coded components, cabled around and each fused to a central binding spline. Cold environment installation: When installing cables that have been stored at ambient temperatures of 32 degrees Fahrenheit (0 degrees Centigrade) or lower, Belden recommends conditioning of the cable for 12 hours at room temperature prior to individual cable leg separation. Put Ups and Colors: Item # Putup Ship Weight Color 502PTZ 0001000 1,000 FT 89.000 LB NONE RG59 +2C18 FS +2C18 CMR BPEEL 502PTZ 000500 500 FT 45.000 LB NONE RG59 +2C18 FS +2C18 CMR BPEEL Revision Number: 1 Notes Item Desc Revision Date: 02-28-2014 (c) 2016 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 4 of 4 08-26-2016 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Belden Wire & Cable: 502PTZ 000500