SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE Note.6
RATEDPOWER Note.6
OUTPUT VOLTAGE ADJ.RANGE
SETUP,RISE,HOLDTIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
500ms,20ms,30ms/230VAC1200ms,30ms,22ms/115VAC atfullload
47~63Hz
3A/115VAC2A/230VAC
COLDSTART 50A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
-25~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )on+5Voutput
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
218.2Khrsmin.MIL-HDBK-217F(25 )
199*98*38mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
FileName:RD-125-SPEC2004-07-29
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
125WDualOutputSwitchingPowerSupply RD-125 se ri es
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note7)
88~132VAC/176~264VACselectedbyswitch248~373VDC(Withstand300VACsurgefor5sec.Withoutdamage)
RD-125-1224
12V 24V
3.7A 3.7A
1~7A 0.4~5A
133.2W
120mVp-p 200mVp-p
CH1:11.4 ~13.2V
0.5%
2.0%
1.0%
+8,-5%
1.0% 5.0%
85%
CH1:13.8~16.2V
RD-125-1248 RD-125-2448
12V 24V48V 48V
2.3A 2A2.3A 2A
1~7A 0.5~4A0.2~2.5A 0.2~2.5A
138W 144W
120mVp-p 200mVp-p240mVp-p 240mVp-p
CH1:11.4 ~13.2V CH1:22.8 ~26.4V
0.5% 0.5%
2.0% 1.0%
1.0% 1.0%
4.0%
1.0% 1.0%5.0%
+8,-5%
3.0%
86% 86%
CH1:13.8~16.2V CH1:27.6~32.4V
0.7Kg;20pcs/15Kg/0.72CUFT
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
long life electrolytic capacitors
Features :