Low Voltage Supplementary Fuses In-line non-rejecting fuses and fuse holders GLR GMF Specifications Class: Supplemental Description: Fast-acting, non-rejection, in-line fuse. Construction: Glass tube. Ratings: Volts -- 300Vac (or less) Amps -- 316-15A IR -- 10,000A Agency Information: CE, Std. 248-14, UL Listed, 015A/300Vac (Guide JDYX, File E19180), CSA Certified, 0-10A/300V (Class 1422-01, File 53787). GRF Features and Benefits * In-line, fast-acting circuit protection. Features and Benefits * In-line, time-delay circuits protection. Typical Applications * In-Line Lighting Ballast Protection Catalog Numbers (Amps) and Non-Rejection Holders Fuse GLR-31 6 GLR-12 GLR-1 GLR-1 12 GLR-1 61 0 GLR-2 GLR-3 GLR-4 Holder1, 2 HLR HLR HLR HLR HLR HLR HLR HLR Fuse GLR-5 GLR-6 GLR-7 GLR-8 GLR-9 GLR-10 GLR-12 GLR-15 Holder1, 2 HLR HLR HLR HLR HLR HLR HLR HLR-2A 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 622501, File 47235 12A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042". * For two leads order HLR-2A, 15A, 300V * * Specifications Class: Supplemental Description: Time-delay, non-rejection, in-line fuse. Construction: Glass tube. Ratings: Volts -- 300Vac (or less) Amps -- 310-10A IR -- 10,000A Agency Information: CE, Std. 248-14 0-10A, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787). An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. Do not put tension on line (rear) terminal of fuse holder. Typical Applications * In-Line Lighting Ballast Protection Catalog Numbers (-Amps) and Non-Rejection Holders Fuse GMF-31 0 GMF-12 GMF-61 0 GMF-81 0 GMF-1 GMF-1 14 GMF-1 61 0 GMF-2 GMF-2 12 GMF-2 81 0 Holder1, 2 HLR HLR HLR HLR HLR HLR HLR HLR HLR HLR Fuse GMF-3 GMF-3 21 0 GMF-4 GMF-5* GMF-6 14 GMF-10 GRF-7 GRF-8 GRF-10 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043"to 0.062" or #4909 for thickness 0.030" to 0.042". *For two leads order HLR-2A, 15A, 300V * * An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. Do not put tension on line (rear) terminal of fuse holder. *HLR Fuse Holder for both GMF & GRF fuses. Data Sheet: 2032 52 Holder1, 2 HLR HLR HLR HLR HLR HLR HLR HLR HLR Data Sheet: 2031 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp