For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
52
Low Voltage Supplementary Fuses
GLR
Specifications
Class: Supplemental
Description: Fast-acting,
non-rejection, in-line fuse.
Construction: Glass tube.
Ratings:
Volts — 300Vac (or less)
Amps 316-15A
IR — 10,000A
Agency Information: CE, Std. 248-14, UL Listed, 0-
15A/300Vac (Guide JDYX, File E19180), CSA Certified,
0-10A/300V (Class 1422-01, File 53787).
Features and Benefits
• In-line, fast-acting circuit protection.
Typical Applications
• In-Line Lighting Ballast Protection
Catalog Numbers (Amps) and Non-Rejection Holders
Fuse Holder1, 2 Fuse Holder1, 2
GLR-316 HLR GLR-5 HLR
GLR-12HLR GLR-6 HLR
GLR-1 HLR GLR-7 HLR
GLR-112HLR GLR-8 HLR
GLR-1610 HLR GLR-9 HLR
GLR-2 HLR GLR-10 HLR
GLR-3 HLR GLR-12 HLR
GLR-4 HLR GLR-15 HLR-2A
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-
01, File 47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip
(BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of
thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”.
* For two leads order HLR-2A, 15A, 300V
An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes
WITHOUT
leads. The customer inserts #18 insulated solid copper wire into the line
side receptacle as well as into the load side receptacle. It has the same body
dimensions, utilizes the same mounting hole, and takes the same mounting clips as
the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File
E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
Do not put tension on line (rear) terminal of fuse holder.
GMF
GRF
Specifications
Class: Supplemental
Description: Time-delay, non-rejec-
tion, in-line fuse.
Construction: Glass tube.
Ratings:
Volts — 300Vac (or less)
Amps 310-10A
IR — 10,000A
Agency Information: CE, Std. 248-14 0-10A, UL Listed
(Guide JDYX, File E19180), CSA Certified, (Class 1422-01,
File 53787).
Features and Benefits
• In-line, time-delay circuits protection.
Typical Applications
• In-Line Lighting Ballast Protection
Catalog Numbers (-Amps) and Non-Rejection Holders
Fuse Holder1, 2 Fuse Holder1, 2
GMF-310 HLR GMF-3 HLR
GMF-12HLR GMF-3 210 HLR
GMF-610 HLR GMF-4 HLR
GMF-810 HLR GMF-5* HLR
GMF-1 HLR GMF-6 14HLR
GMF-1 14HLR GMF-10 HLR
GMF-1 610 HLR GRF-7 HLR
GMF-2 HLR GRF-8 HLR
GMF-2 12HLR GRF-10 HLR
GMF-2 810 HLR
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File
47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in
a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or
#4909 for thickness 0.030” to 0.042”.
*For two leads order HLR-2A, 15A, 300V
An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes
WITHOUT
leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well
as into the load side receptacle. It has the same body dimensions, utilizes the same mounting
hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A,
300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
Do not put tension on line (rear) terminal of fuse holder.
In-line non-rejecting fuses and fuse holders
Data Sheet: 2032 Data Sheet: 2031
*HLR Fuse Holder
for both GMF & GRF fuses.