Aluminum electrolytic capacitors Single-ended capacitors Series/Type: B41827, B43827 Date: December 2010 (c) EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Single-ended capacitors B41827, B43827 Standard series 85 C General-purpose grade capacitors Applications General-purpose applications Semi-professional to professional application range For filtering, coupling and pulse circuits Features Miniaturized dimensions RoHS-compatible Useful life of 2000 h at 85 C Construction Radial leads Charge-discharge proof, polar Aluminum case with insulating sleeve Minus pole marking on the insulating sleeve Case with safety vent from diameter 8 mm Delivery mode Bulk Taped, Ammo pack Cut (see chapter "Single-ended Taping, packing and lead configurations, Cut leads (Chapter A)") Kinked (see chapter "Single-ended Taping, packing and lead configurations, Kinked leads (Chapter A)") Refer to chapter "Single-ended capacitors Taping, packing and lead configurations" for further details. Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 39 B41827, B43827 Standard series 85 C Specifications and characteristics in brief Series Rated voltage VR Surge voltage VS Rated capacitance CR Capacitance tolerance Dissipation factor (max.) (20 C, 120 Hz) B41827 B43827 6.3 ... 100 V DC 160 ... 450 V DC VR 250 V DC: 1.15 VR (at room temperature) VR > 250 V DC: 1.1 VR (at room temperature) 0.47 ... 22000 F 0.47 ... 330 F 20% M 20% M For capacitance higher than 1000 F add 0.02 for every increase of 1000 F. VR 6.3 (V DC) tan 10 16 25 or 3 A, whichever is greater Useful life 85 C; VR; IAC,R > 2000 h C/C tan Ileak 50 63 100 160 350 450 ... ... 250 400 0.22 0.20 0.16 0.14 0.12 0.10 0.09 0.08 0.18 0.20 0.23 Leakage current Ileak (20 C, after 5 minutes) Requirements 35 20% of initial value 2 times initial specified value initial specified limit After storage for 1000 h at 85 C, the capacitors shall meet the requirement of load life test after reforming process. After test: VR to be applied for 30 minutes, 24 to 48 hours before measurement. Vibration resistance test To IEC 60068-2-6, test Fc: Frequency range 10 ... 55 Hz, displacement amplitude 0.75 mm, acceleration max. 10 g, duration 3 x 2 h. If can size D <16 mm, capacitor is mounted by the leads If can size D 16 mm, capacitor rigidly clamped by the aluminum case Shelf life IEC climatic category To IEC 60068-1: VR 100 V DC: 40/085/56 (40 C/+85 C/56 days damp heat test) VR > 100 V DC: 25/085/56 (25 C/+85 C/56 days damp heat test) Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 39 B41827, B43827 Standard series 85 C Dimensional drawing Safety vent for diameter 8 mm. Case Dimensions dxl mm 5 x 11 6.3 x 11 8 x 11.5 10 x 12.5 10 x 16 10 x 20 12.5 x 20 12.5 x 25 16 x 25 16 x 31.5 16 x 35.5 18 x 35.5 18 x 40 dmax x lmax mm 5.5 x 12.5 6.8 x 12.5 8.5 x 13.0 11.0 x 14.0 11.0 x 17.5 11.0 x 22.0 13.5 x 22.0 13.5 x 27.0 17.0 x 27.0 17.0 x 33.5 17.0 x 37.5 19.0 x 37.5 19.0 x 42.0 Please read Cautions and warnings and Important notes at the end of this document. a mm 2.0 0.5 2.5 0.5 3.5 0.5 5.0 0.5 5.0 0.5 5.0 0.5 5.0 0.5 5.0 0.5 7.5 0.5 7.5 0.5 7.5 0.5 7.5 0.5 7.5 0.5 Page 4 of 39 b mm 0.50 0.1 0.50 0.1 0.60 0.1 0.60 0.1 0.60 0.1 0.60 0.1 0.60 0.1 0.60 0.1 0.80 0.1 0.80 0.1 0.80 0.1 0.80 0.1 0.80 0.1 B41827 Standard series 85 C Overview of available types B41827 VR (V DC) 6.3 10 16 25 Case dimensions d x l (mm) CR (F) 47 5 100 5 x 11 5 x 11 x 11 6.3 x 11 220 5 x 11 6.3 x 11 6.3 x 11 8 x 11.5 330 6.3 x 11 6.3 x 11 8 x 11.5 10 x 12.5 470 6.3 x 11 8 x 11.5 8 x 11.5 10 x 12.5 x 16 10 x 20 1000 10 x 12.5 10 x 12.5 10 2200 10 x 20 10 x 20 12.5 x 20 12.5 x 25 3300 12.5 x 20 12.5 x 20 12.5 x 25 16 x 25 4700 12.5 x 25 12.5 x 25 16 x 25 16 x 31.5 6800 16 x 25 10000 16 x 25 16 x 35.5 18 x 35.5 15000 16 x 35.5 18 x 35.5 22000 18 x 40 Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 39 B41827 Standard series 85 C VR (V DC) 35 50 63 100 Case dimensions d x l (mm) CR (F) 0.47 5 x 11 1.0 5 x 11 2.2 5 x 11 3.3 5 x 11 4.7 5 x 11 10 5 x 11 5 x 11 6.3 x 11 5 x 11 6.3 x 11 8 x 11.5 33 5 x 11 5 x 11 6.3 x 11 10 x 12.5 47 5 x 11 6.3 x 11 6.3 x 11 10 x 12.5 x 20 22 100 6.3 x 11 8 x 11.5 10 x 12.5 10 x 20 12.5 x 25 220 10 x 12.5 10 x 12.5 10 330 10 x 12.5 10 x 16 12.5 x 20 16 x 25 470 10 x 16 10 x 20 12.5 x 25 16 x 31.5 1000 12.5 x 25 16 x 20 16 18 x 40 2200 16 x 25 16 x 31.5 3300 16 x 31.5 4700 18 x 35.5 Please read Cautions and warnings and Important notes at the end of this document. Page 6 of 39 x 31.5 B43827 Standard series 85 C Overview of available types B43827 VR (V DC) 160 200 250 350 400 450 Case dimensions d x l (mm) CR (F) 0.47 5 x 11 5 x 11 1.0 5 x 11 5 x 11 2.2 5 x 11 3.3 6.3 x 11 6.3 x 11 4.7 6.3 x 11 8 x 11.5 8 x 11.5 10 x 12.5 x 20 6.3 x 11 6.3 x 11 8 x 11.5 6.3 x 11 8 x 11.5 6.3 x 11 8 x 11.5 8 x 11.5 10 x 12.5 6.3 x 11 10 x 12.5 10 x 12.5 10 x 16 x 11.5 10 x 12.5 10 x 16 10 x 20 10 x 12.5 10 x 20 12.5 x 20 10 x 20 12.5 x 25 12.5 x 20 10 8 22 10 x 16 10 16 x 25 16 x 25 33 10 x 20 12.5 x 20 12.5 x 25 16 x 25 16 x 25 16 x 31.5 47 12.5 x 25 12.5 x 20 12.5 x 25 16 x 35.5 16 x 35.5 18 x 40 18 x 40 100 16 x 25 16 x 25 220 16 x 35.5 18 x 35.5 330 18 x 35.5 Please read Cautions and warnings and Important notes at the end of this document. 16 x 31.5 Page 7 of 39 B41827 Standard series 85 C Technical data and ordering codes B41827 CR 120 Hz, 20 C F VR = 6.3 V DC 220 330 470 1000 2200 3300 4700 6800 10000 15000 22000 VR = 10 V DC 100 220 330 470 1000 2200 3300 4700 10000 15000 VR = 16 V DC 100 220 330 470 1000 Case dimensions dxl mm IAC,R 120 Hz, 85 C mA Ordering code (composition see below) 5 x 11 6.3 x 11 6.3 x 11 10 x 12.5 10 x 20 12.5 x 20 12.5 x 25 16 x 25 16 x 25 16 x 35.5 18 x 40 200 270 321 542 1005 1195 1560 1925 2360 2855 3345 B41827A2227M*** B41827A2337M*** B41827A2477M*** B41827A2108M*** B41827A2228M*** B41827A2338M*** B41827A2478M*** B41827A2688M*** B41827A2109M*** B41827A2159M*** B41827A2229M*** 5 x 11 6.3 x 11 6.3 x 11 8 x 11.5 10 x 12.5 10 x 20 12.5 x 20 12.5 x 25 16 x 35.5 18 x 35.5 130 280 290 385 650 1082 1436 1783 2700 3100 B41827A3107M*** B41827A3227M*** B41827A3337M*** B41827A3477M*** B41827A3108M*** B41827A3228M*** B41827A3338M*** B41827A3478M*** B41827A3109M*** B41827A3159M*** 5 x 11 6.3 x 11 8 x 11.5 8 x 11.5 10 x 16 160 261 373 446 790 B41827A4107M*** B41827A4227M*** B41827A4337M*** B41827A4477M*** B41827A4108M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk 002 = for cut leads, bulk 016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm) 007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d x l = 16 x 25 ... 16 x 31.5 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 8 of 39 B41827 Standard series 85 C Technical data and ordering codes B41827 CR 120 Hz, 20 C F VR = 16 V DC 2200 3300 4700 10000 VR = 25 V DC 47 100 220 330 470 1000 2200 3300 4700 VR = 35 V DC 33 47 100 220 330 470 1000 2200 3300 4700 Case dimensions dxl mm IAC,R 120 Hz, 85 C mA Ordering code (composition see below) 12.5 x 20 12.5 x 25 16 x 25 18 x 35.5 1310 1695 2100 2980 B41827A4228M*** B41827A4338M*** B41827A4478M*** B41827A4109M*** 5 x 11 6.3 x 11 8 x 11.5 10 x 12.5 10 x 12.5 10 x 20 12.5 x 25 16 x 25 16 x 31.5 108 192 335 446 547 962 1560 1985 2455 B41827A5476M*** B41827A5107M*** B41827A5227M*** B41827A5337M*** B41827A5477M*** B41827A5108M*** B41827A5228M*** B41827A5338M*** B41827A5478M*** 5 x 11 5 x 11 6.3 x 11 10 x 12.5 10 x 12.5 10 x 16 12.5 x 25 16 x 25 16 x 31.5 18 x 35.5 102 130 212 390 495 652 1158 1810 2293 2710 B41827A7336M*** B41827A7476M*** B41827A7107M*** B41827A7227M*** B41827A7337M*** B41827A7477M*** B41827A7108M*** B41827A7228M*** B41827A7338M*** B41827A7478M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk 002 = for cut leads, bulk 016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm) 007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d x l = 16 x 25 ... 16 x 31.5 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 9 of 39 B41827 Standard series 85 C Technical data and ordering codes B41827 CR 120 Hz, 20 C F VR = 50 V DC 10 22 33 47 100 220 330 470 1000 2200 VR = 63 V DC 10 22 33 47 100 220 330 470 1000 VR = 100 V DC 0.47 1.0 2.2 3.3 4.7 10 22 Case dimensions dxl mm IAC,R 120 Hz, 85 C mA Ordering code (composition see below) 5 x 11 5 x 11 5 x 11 6.3 x 11 8 x 11.5 10 x 12.5 10 x 16 10 x 20 16 x 20 16 x 31.5 58 85 117 155 260 430 510 700 1100 1540 B41827A6106M*** B41827A6226M*** B41827A6336M*** B41827A6476M*** B41827A6107M*** B41827A6227M*** B41827A6337M*** B41827A6477M*** B41827A6108M*** B41827A6228M*** 5 x 11 6.3 x 11 6.3 x 11 6.3 x 11 10 x 12.5 10 x 20 12.5 x 20 12.5 x 25 16 x 31.5 60 100 140 170 300 475 710 900 1300 B41827A8106M*** B41827A8226M*** B41827A8336M*** B41827A8476M*** B41827A8107M*** B41827A8227M*** B41827A8337M*** B41827A8477M*** B41827A8108M*** 5 x 11 5 x 11 5 x 11 5 x 11 5 x 11 6.3 x 11 8 x 11.5 13 20 29 36 43 75 130 B41827A9474M*** B41827A9105M*** B41827A9225M*** B41827A9335M*** B41827A9475M*** B41827A9106M*** B41827A9226M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk 002 = for cut leads, bulk 016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm) 007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d x l = 16 x 25 ... 16 x 31.5 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 10 of 39 B41827 Standard series 85 C Technical data and ordering codes B41827 CR 120 Hz, 20 C F VR = 100 V DC 33 47 100 220 330 470 1000 Case dimensions dxl mm IAC,R 120 Hz, 85 C mA Ordering code (composition see below) 10 x 12.5 10 x 12.5 10 x 20 12.5 x 25 16 x 25 16 x 31.5 18 x 40 180 230 370 620 760 1000 1380 B41827A9336M*** B41827A9476M*** B41827A9107M*** B41827A9227M*** B41827A9337M*** B41827A9477M*** B41827A9108M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk 002 = for cut leads, bulk 016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm) 007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d x l = 16 x 25 ... 16 x 31.5 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 11 of 39 B43827 Standard series 85 C Technical data and ordering codes B43827 CR 120 Hz, 20 C F VR = 160 V DC 0.47 1.0 2.2 3.3 4.7 10 22 33 47 100 220 330 VR = 200 V DC 3.3 4.7 10 22 33 47 100 220 VR = 250 V DC 0.47 1.0 2.2 3.3 4.7 10 Case dimensions dxl mm IAC,R 120 Hz, 85 C mA Ordering code (composition see below) 5 x 11 5 x 11 5 x 11 6.3 x 11 6.3 x 11 8 x 11.5 10 x 16 10 x 20 12.5 x 25 16 x 25 16 x 35.5 18 x 35.5 15 22 33 40 49 80 152 203 268 423 786 945 B43827A1474M*** B43827A1105M*** B43827A1225M*** B43827A1335M*** B43827A1475M*** B43827A1106M*** B43827A1226M*** B43827A1336M*** B43827A1476M*** B43827A1107M*** B43827A1227M*** B43827A1337M*** 6.3 x 11 8 x 11.5 10 x 12.5 10 x 20 12.5 x 20 12.5 x 20 16 x 25 18 x 35.5 40 56 95 170 225 267 490 815 B43827A2335M*** B43827A2475M*** B43827A2106M*** B43827A2226M*** B43827A2336M*** B43827A2476M*** B43827A2107M*** B43827A2227M*** 5 x 11 5 x 11 6.3 x 11 6.3 x 11 8 x 11.5 10 x 12.5 15 22 33 47 56 103 B43827F2474M*** B43827F2105M*** B43827F2225M*** B43827F2335M*** B43827F2475M*** B43827F2106M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk 002 = for cut leads, bulk 016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm) 007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d x l = 16 x 25 ... 16 x 31.5 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 12 of 39 B43827 Standard series 85 C Technical data and ordering codes B43827 CR 120 Hz, 20 C F VR = 250 V DC 22 33 47 100 VR = 350 V DC 1.0 2.2 3.3 4.7 10 22 33 47 100 VR = 400 V DC 0.47 1.0 2.2 3.3 4.7 10 22 33 47 Case dimensions dxl mm IAC,R 120 Hz, 85 C mA Ordering code (composition see below) 10 x 20 12.5 x 25 12.5 x 25 16 x 31.5 185 225 268 525 B43827F2226M*** B43827F2336M*** B43827F2476M*** B43827F2107M*** 6.3 x 11 8 x 11.5 10 x 12.5 10 x 12.5 10 x 20 12.5 x 25 16 x 25 16 x 35.5 18 x 40 22 38 54 65 115 185 276 334 510 B43827A4105M*** B43827A4225M*** B43827A4335M*** B43827A4475M*** B43827A4106M*** B43827A4226M*** B43827A4336M*** B43827A4476M*** B43827A4107M*** 6.3 x 11 6.3 x 11 8 x 11.5 10 x 12.5 10 x 16 12.5 x 20 16 x 25 16 x 25 16 x 35.5 15 23 40 55 67 118 200 280 362 B43827A9474M*** B43827A9105M*** B43827A9225M*** B43827A9335M*** B43827A9475M*** B43827A9106M*** B43827A9226M*** B43827A9336M*** B43827A9476M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk 002 = for cut leads, bulk 016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm) 007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d x l = 16 x 25 ... 16 x 31.5 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 39 B43827 Standard series 85 C Technical data and ordering codes B43827 CR 120 Hz, 20 C F VR = 450 V DC 0.47 1.0 2.2 3.3 4.7 10 22 33 47 Case dimensions dxl mm IAC,R 120 Hz, 85 C mA Ordering code (composition see below) 8 x 11.5 8 x 11.5 10 x 12.5 10 x 16 10 x 20 12.5 x 20 16 x 25 16 x 31.5 18 x 40 18 24 36 44 56 95 170 235 302 B43827A5474M*** B43827A5105M*** B43827A5225M*** B43827A5335M*** B43827A5475M*** B43827A5106M*** B43827A5226M*** B43827A5336M*** B43827A5476M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk 002 = for cut leads, bulk 016 = for taped leads, Ammo pack, lead spacing F = 2.0 mm (for 5 mm) 007 = for taped leads, Ammo pack, lead spacing F = 2.5 mm for 5 ... 6.3 mm) 006 = for taped leads, Ammo pack, lead spacing F = 3.5 mm (for 8 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (for 5 ... 12.5 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (for d x l = 16 x 25 ... 16 x 31.5 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 39 B41827, B43827 Standard series 85 C Useful life depending on ambient temperature TA under ripple current operating conditions1) B41827 Useful life depending on ambient temperature TA under ripple current operating conditions1) B43827 1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life graphs. Please read Cautions and warnings and Important notes at the end of this document. Page 15 of 39 B41827, B43827 Standard series 85 C Frequency factor of permissible ripple current IAC versus frequency f Please read Cautions and warnings and Important notes at the end of this document. Page 16 of 39 B41827, B43827 Standard series 85 C Taping, packing and lead configurations Taping Single-ended capacitors are available taped in Ammo pack from diameter 4 to 18 mm as follows: Lead spacing F = 2.0 mm ( d = 4 ... 5 mm) Lead spacing F = 2.5 mm ( d = 4 ... 6.3 mm) Lead spacing F = 3.5 mm ( d = 8 mm) Lead spacing F = 5.0 mm ( d = 4 ... 12.5 mm) Lead spacing F = 7.5 mm ( d = 16 ... 18 mm). Lead spacing 2.0 mm ( d = 4 ... 5 mm) Last 3 digits of ordering code: 016 Dimensions in mm d F 4 ... 5 2.0 H W W0 W1 W2 P P0 P1 I1 t h 18.5 18.0 7.0 9.0 3.0 12.7 12.7 5.10 1.0 0.7 1 D0 4.0 min. 0.5 max. 1.0 0.3 0.7 max. 0.2 1.0 0.2 +0.8 0.75 0.5 0.2 Please read Cautions and warnings and Important notes at the end of this document. Page 17 of 39 B41827, B43827 Standard series 85 C Lead spacing 2.5 mm ( d = 4 ... 6.3 mm) Last 3 digits of ordering code: 007 Dimensions in mm d 4 ... 6.3 Tolerrance F H W0 W1 W2 2.5 18.5 18.0 5.5 W 9.0 1.5 H0 P P0 P1 16.0 12.7 12.7 5.1 I1 t h 1.0 0.7 1.0 D0 4.0 +0.8 0.75 0.5 min. 0.5 max. 0.5 1.0 0.2 0.5 max. 0.2 max. 0.2 0.2 Lead spacing 3.5 mm ( d = 8 mm) Last 3 digits of ordering code: 006 Dimensions in mm d 8 F 3.5 H 18.5 W 18.0 W0 10 W1 9.0 W2 3.0 P 12.7 P0 12.7 P1 4.6 I1 1.0 t 0.7 Toler- +0.8 1.0 ance 0.2 0.5 min. 0.5 max. 1.0 0.3 0.6 max. 0.2 h 1.0 max. 0.2 Leads can also run straight through the taping area. Taping is available up to dimensions d x l = 8 x 15 mm. Please read Cautions and warnings and Important notes at the end of this document. Page 18 of 39 D0 4.0 B41827, B43827 Standard series 85 C Lead spacing 5.0 mm ( d = 4 ... 8 mm) Last 3 digits of ordering code: 008 Lead spacing 5.0 mm ( d = 10 ... 12.5 mm) Last 3 digits of ordering code: 008 Dimensions in mm d 4 ... 6.3 F H W W0 W1 W2 H0 P P0 P1 I1 t h D0 5.0 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 3.85 1.0 0.6 1.0 4.0 20.0 10.0 16.0 12.7 12.7 3.85 19.0 18.0 12.5 9.0 1.5 12.7 12.7 3.85 1.0 0.6 1.0 4.0 15.0 15.0 5.0 1.0 0.2 0.5 max. +0.3 max. 0.2 0.2 8 10 5.0 12.5 12.5 19.0 Toler- +0.8 0.75 0.5 min. 0.5 max. 0.5 ance 0.2 Taping is available up to dimensions d x l = 10 x 31.5 mm and 12.5 x 25 mm. Taping is not available for d x l = 8 x 20 mm. Please read Cautions and warnings and Important notes at the end of this document. Page 19 of 39 B41827, B43827 Standard series 85 C Lead spacing 7.5 mm ( d = 16 ...18 mm) Last 3 digits of ordering code: 009 Dimensions in mm d 16 F H W 7.5 18.5 18.0 18 Toler0.5 0.8 0.5 ance +0.75 W0 W1 W2 P P0 P1 I1 t P h D0 12.5 9.0 1.5 30.0 15.0 3.75 1.0 0.7 0 0 4.0 min. 0.5 max. 1.0 0.2 0.5 max. 0.2 1.0 1.0 0.2 Taping is available up to dimensions d x l = 16 x 31.5 mm and 18 x 31.5 mm. Please read Cautions and warnings and Important notes at the end of this document. Page 20 of 39 B41827, B43827 Standard series 85 C Cut or kinked leads Single-ended capacitors are available with cut or kinked leads. Other lead configurations also available upon request. Cut leads (Chapter A) Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088, B43827, B43828. Last 3 digits of ordering code: 002 Case size d x l (mm) 4 x7 Dimensions (mm) a 0.5 1.5 12.5 x 16 Dimensions (mm) a 0.5 5.0 5 x7 2.0 12.5 x 20 5.0 5 x 11 2.0 12.5 x 25 5.0 6.3 x 7 2.5 12.5 x 31.5 5.0 6.3 x 11 2.5 12.5 x 35.5 5.0 8 x7 3.5 12.5 x 40 5.0 8 x 11.5 3.5 16 x 20 7.5 8 x 15 3.5 16 x 25 7.5 8 x 20 3.5 16 x 31.5 7.5 10 x 12.5 5.0 16 x 35.5 7.5 10 x 16 5.0 16 x 40 7.5 10 x 20 5.0 18 x 20 7.5 10 x 25 5.0 18 x 25 7.5 10 x 31.5 5.0 18 x 31.5 7.5 18 x 35.5 7.5 18 x 40 7.5 Please read Cautions and warnings and Important notes at the end of this document. Case size d x l (mm) Page 21 of 39 B41827, B43827 Standard series 85 C Cut leads (Chapter B) Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824, B42851, B43866, B43867, B43890, B43896. Last 3 digits of ordering code: 002 With stand-off rubber seal Case size d x l (mm) With flat rubber seal Please read Cautions and warnings and Important notes at the end of this document. Page 22 of 39 Dimensions (mm) a 0.5 10 x 12.5 5.0 10 x 16 5.0 10 x 20 5.0 12.5 x 20 5.0 12.5 x 25 5.0 16 x 20 7.5 16 x 25 7.5 16 x 31.5 7.5 16 x 35.5 7.5 18 x 20 7.5 18 x 25 7.5 18 x 31.5 7.5 18 x 35 7.5 18 x 40 7.5 B41827, B43827 Standard series 85 C Kinked leads (Chapter A) Available for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088, B43827, B43828. Last 3 digits of ordering code: 001 Case size d x l (mm) 4 x7 Dimensions (mm) a 0.5 1.5 12.5 x 16 Dimensions (mm) a 0.5 5.0 5 x7 2.0 12.5 x 20 5.0 5 x 11 2.0 12.5 x 25 5.0 6.3 x 7 2.5 12.5 x 31.5 5.0 6.3 x 11 2.5 12.5 x 35.5 5.0 8 x7 3.5 12.5 x 40 5.0 8 x 11.5 3.5 16 x 20 7.5 8 x 15 3.5 16 x 25 7.5 8 x 20 3.5 16 x 31.5 7.5 10 x 12.5 5.0 16 x 35.5 7.5 10 x 16 5.0 16 x 40 7.5 10 x 20 5.0 18 x 20 7.5 10 x 25 5.0 18 x 25 7.5 10 x 31.5 5.0 18 x 31.5 7.5 18 x 35.5 7.5 18 x 40 7.5 Please read Cautions and warnings and Important notes at the end of this document. Case size d x l (mm) Page 23 of 39 B41827, B43827 Standard series 85 C Kinked leads (Chapter B) Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824, B42851, B43866, B43867, B43890, B43896. Last 3 digits of ordering code: 001 With stand-off rubber seal Case size d x l (mm) With flat rubber seal Please read Cautions and warnings and Important notes at the end of this document. Page 24 of 39 Dimensions (mm) a 0.5 10 x 20 5.0 12.5 x 20 5.0 12.5 x 25 5.0 16 x 20 7.5 16 x 25 7.5 16 x 31.5 7.5 16 x 35.5 7.5 18 x 20 7.5 18 x 25 7.5 18 x 31.5 7.5 18 x 35 7.5 18 x 40 7.5 B41827, B43827 Standard series 85 C PAPR leads (Protection Against Polarity Reversal) These lead configurations ensure correct placement of the capacitor on the PCB with regard to polarity. PAPR leads are available for diameters from 10 mm up to 18 mm. There are three configurations available: Crimped leads, J leads, bent 90 leads Available for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824, B42851, B43866, B43867, B43890, B43896. Crimped leads Last 3 digits of ordering code: 003 With stand-off rubber seal With flat rubber seal Suggestion for PCB hole diameter Case size d x l (mm) Dimensions (mm) B 0.2 C 0.5 D 0.1 E 0.1 16 x 20 1.5 3.0 1.3 0.3 7.5 0.8 0.05 16 x 25 1.5 3.0 1.3 0.3 7.5 0.8 0.05 16 x 31.5 1.5 3.0 1.3 0.3 7.5 0.8 0.05 16 x 35.5 1.5 3.0 1.3 0.3 7.5 0.8 0.05 18 x 20 1.5 3.0 1.3 0.3 7.5 0.8 0.1 18 x 25 1.5 3.0 1.3 0.3 7.5 0.8 0.1 18 x 31.5 1.5 3.0 1.3 0.3 7.5 0.8 0.1 18 x 35 1.5 3.0 1.3 0.3 7.5 0.8 0.1 18 x 40 1.5 3.0 1.3 0.3 7.5 0.8 0.1 Please read Cautions and warnings and Important notes at the end of this document. Page 25 of 39 a 0.5 b B41827, B43827 Standard series 85 C J leads Last 3 digits of ordering code: 004 Suggestion for PCB hole diameter Case size d x l (mm) Dimensions (mm) C 0.5 E 0.5 J 0.2 10 x 12.5 3.2 0.7 1.2 5.0 0.6 0.05 10 x 16 3.2 0.7 1.2 5.0 0.6 0.05 10 x 20 3.2 0.7 1.2 5.0 0.6 0.05 12.5 x 20 3.2 0.7 1.2 5.0 0.6 0.05 12.5 x 25 3.2 0.7 1.2 5.0 0.6 0.05 16 x 20 3.5 0.7 1.6 7.5 0.8 0.05 16 x 25 3.5 0.7 1.6 7.5 0.8 0.05 16 x 31.5 3.5 0.7 1.6 7.5 0.8 0.05 16 x 35.5 3.5 0.7 1.6 7.5 0.8 0.05 18 x 20 3.5 0.7 1.6 7.5 0.8 0.1 18 x 25 3.5 0.7 1.6 7.5 0.8 0.1 18 x 31.5 3.5 0.7 1.6 7.5 0.8 0.1 18 x 35 3.5 0.7 1.6 7.5 0.8 0.1 Please read Cautions and warnings and Important notes at the end of this document. Page 26 of 39 a 0.5 b B41827, B43827 Standard series 85 C Bent 90 leads for horizontal mounting pinning Last 3 digits of ordering code: 012 Case size d x l (mm) Dimensions (mm) C 0.5 E 0.5 F 0.5 a 0.5 b 16 x 20 4.0 4.0 12.0 7.5 0.8 0.05 16 x 25 4.0 4.0 12.0 7.5 0.8 0.05 16 x 31.5 4.0 4.0 12.0 7.5 0.8 0.05 16 x 35.5 4.0 4.0 12.0 7.5 0.8 0.05 18 x 20 4.0 4.0 13.0 7.5 0.8 0.1 18 x 25 4.0 4.0 13.0 7.5 0.8 0.1 18 x 31.5 4.0 4.0 13.0 7.5 0.8 0.1 18 x 35 4.0 4.0 13.0 7.5 0.8 0.1 18 x 40 4.0 4.0 13.0 7.5 0.8 0.1 Bent leads for diameter 12.5 mm available upon request. Please read Cautions and warnings and Important notes at the end of this document. Page 27 of 39 B41827, B43827 Standard series 85 C Packing units and box dimensions Ammo pack Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088, B43827, B43828. Please read Cautions and warnings and Important notes at the end of this document. Case size dxl mm Dimensions (mm) Amax Bmax Cmax Packing units pcs. 4x7 330 50 196 2000 5x7 330 50 226 2000 5 x 11 330 50 226 2000 6.3 x 7 330 50 286 2000 6.3 x 11 330 50 286 2000 8x7 330 50 246 1000 8 x 11.5 330 50 246 1000 8 x 15 330 50 246 500 10 x 12.5 330 50 196 500 10 x 16 330 54 196 500 10 x 20 330 58 196 500 12.5 x 20 341 60 272 500 12.5 x 25 341 65 272 500 16 x 25 320 65 270 300 16 x 31.5 315 65 275 300 18 x 20 315 65 275 250 18 x 25 315 65 275 250 18 x 31.5 315 65 275 250 Page 28 of 39 B41827, B43827 Standard series 85 C Ammo pack Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824, B42851, B43866, B43867, B43890, B43896. Please read Cautions and warnings and Important notes at the end of this document. Case size dxl mm Dimensions (mm) Amax Bmax Cmax Packing units pcs. 8 x 11.5 345 55 240 1000 10 x 12.5 345 55 280 750 10 x 16 345 60 200 500 10 x 20 345 60 200 500 12.5 x 20 345 65 280 500 12.5 x 25 345 65 280 500 16 x 20 315 65 275 300 16 x 25 315 65 275 300 16 x 31.5 315 65 275 300 18 x 20 315 65 275 250 18 x 25 315 65 275 250 18 x 31.5 315 65 275 250 Page 29 of 39 B41827, B43827 Standard series 85 C Overview of packing units and code numbers for case sizes 4 x 7 ... 16 x 40 Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088, B43827, B43828. Case size dxl mm Standard, bulk pcs. Taped, Ammo pack pcs. Kinked leads, bulk pcs. Cut leads, bulk pcs. 4 x7 10000 2000 15000 15000 5 x7 7500 2000 10000 10000 5 x 11 5000 2000 10000 10000 6.3 x 7 5000 2000 10000 10000 6.3 x 11 5000 2000 5000 5000 8 x7 5000 1000 5000 5000 8 x 11.5 2500 1000 4000 4000 8 x 15 2000 1000 2500 2500 8 x 20 1500 2000 2000 10 x 12.5 2000 500 2500 2500 10 x 16 1500 500 2000 2000 10 x 20 1000 500 1500 1500 10 x 25 1000 500 1250 1250 12.5 x 16 750 500 1000 1000 12.5 x 20 750 500 500 500 12.5 x 25 750 500 500 500 12.5 x 31.5 500 750 750 12.5 x 35.5 500 750 750 12.5 x 40 500 750 750 16 x 20 375 300 500 500 16 x 25 375 300 500 500 16 x 31.5 250 300 375 375 16 x 35.5 250 375 375 16 x 40 250 The last three digits of the complete ordering code state the lead configuration 000 Please read Cautions and warnings and Important notes at the end of this document. 375 Code F (mm) d (mm) 006 007 008 009 016 3.5 2.5 5.0 7.5 2.0 8 4 ... 6.3 4 ... 12.5 16 ... 18 4 ... 5 Page 30 of 39 001 375 002 B41827, B43827 Standard series 85 C Overview of packing units and code numbers for case sizes 18 x 20 ... 18 x 40 Valid for series B41002, B41022, B41044, B41827, B41828, B43044, B43082, B43086, B43088, B43827, B43828. Case size dxl mm Standard, bulk pcs. Taped, Ammo pack pcs. Kinked leads, bulk pcs. Cut leads, bulk pcs. 18 x 20 250 250 100 100 18 x 25 250 250 100 100 18 x 31.5 250 250 100 100 18 x 35.5 250 100 100 18 x 40 250 The last three digits of the complete ordering code state the lead configuration 000 Please read Cautions and warnings and Important notes at the end of this document. 100 Code F (mm) d (mm) 009 7.5 16 ... 18 Page 31 of 39 001 100 002 B41827, B43827 Standard series 85 C Overview of packing units and code numbers for case sizes 8 x 11.5 ... 16 x 35.5 Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824, B42851, B43866, B43867, B43890, B43896. PAPR Case size dxl Taped, Ammo pack mm Standard, bulk pcs. pcs. Kinked leads, bulk pcs. Cut leads, bulk pcs. Crimped J leads, leads, blister blister pcs. pcs. 1000 8 x 11.5 1000 10 x 12.5 1000 750 10 x 16 1000 500 1000 10 x 20 500 500 500 500 12.5 x 20 350 500 350 350 12.5 x 25 250 500 500 500 12.5 x 30 200 12.5 x 35 175 12.5 x 40 175 16 x 20 250 300 200 200 200 200 120 16 x 25 250 300 200 200 200 200 120 16 x 31.5 200 300 250 250 344 344 120 16 x 35.5 100 100 100 150 150 150 The last three digits of the complete ordering code state the lead configuration 000 Code F (mm) d (mm) 001 002 003 004 012 006 008 009 3.5 5 7.5 8 5...12.5 16...18 1) Available upon request Please read Cautions and warnings and Important notes at the end of this document. Page 32 of 39 1000 Bent 90 leads, blister pcs. 675 675 500 300 1) 225 1) B41827, B43827 Standard series 85 C Overview of packing units and code numbers for case sizes 18 x 20 ... 18 x 40 Valid for series B41858, B41859, B41863, B41866, B41868, B41888, B41890, B41896, B42824, B42851, B43866, B43867, B43890, B43896. PAPR Case size dxl Taped, Ammo pack mm Standard, bulk pcs. pcs. Kinked leads, bulk pcs. Cut leads, bulk pcs. Crimped J leads, leads, blister blister pcs. pcs. Bent 90 leads, blister pcs. 18 x 20 175 18 x 25 150 250 175 175 200 200 120 250 150 150 200 200 18 x 31.5 120 100 250 100 100 150 150 120 18 x 35 100 100 100 150 150 150 18 x 40 125 100 100 120 72 The last three digits of the complete ordering code state the lead configuration 000 Code F (mm) d (mm) 001 002 003 004 012 009 Please read Cautions and warnings and Important notes at the end of this document. 7.5 16...18 Page 33 of 39 B41827, B43827 Standard series 85 C Cautions and warnings Personal safety The electrolytes used by EPCOS have not only been optimized with a view to the intended application, but also with regard to health and environmental compatibility. They do not contain any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide (DMAC). Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They contain flame-retarding substances which will quickly extinguish any flame that may have been ignited. As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce operating electrolytes. However, in exceptional cases, such materials must be used in order to achieve specific physical and electrical properties because no safe substitute materials are currently known. However, the amount of dangerous materials used in our products has been limited to an absolute minimum. Nevertheless, the following rules should be observed when handling aluminum electrolytic capacitors: Any escaping electrolyte should not come into contact with eyes or skin. If electrolyte does come into contact with the skin, wash the affected parts immediately with running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical treatment. Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be well ventilated. Clothing that has been contaminated by electrolyte must be changed and rinsed in water. Please read Cautions and warnings and Important notes at the end of this document. Page 34 of 39 B41827, B43827 Standard series 85 C Product safety The table below summarizes the safety instructions that must be observed without fail. A detailed description can be found in the relevant sections of chapter "General technical information". Topic Safety information Polarity Make sure that polar capacitors are connected with the right polarity. Reverse voltage Voltages polarity classes should be prevented by connecting a diode. Do not exceed the upper category temperature. Upper category temperature Maintenance Mounting position of screwterminal capacitors Mounting of single-ended capacitors Robustness of terminals Soldering Make periodic inspections of the capacitors. Before the inspection, make sure that the power supply is turned off and carefully discharge the electricity of the capacitors. Do not apply any mechanical stress to the capacitor terminals. Do not mount the capacitor with the terminals (safety vent) upside down. Reference chapter "General technical information" 1 "Basic construction of aluminum electrolytic capacitors" 3.1.6 "Reverse voltage" 7.2 "Maximum permissible operating temperature" 10 "Maintenance" 11.1. "Mounting positions of capacitors with screw terminals" The internal structure of single-ended capacitors 11.4 might be damaged if excessive force is applied to "Mounting the lead wires. considerations for Avoid any compressive, tensile or flexural stress. single-ended capacitors" Do not move the capacitor after soldering to PC board. Do not pick up the PC board by the soldered capacitor. Do not insert the capacitor on the PC board with a hole space different to the lead space specified. The following maximum tightening torques must 11.3 not be exceeded when connecting screw "Mounting torques" terminals: M5: 2 Nm M6: 2.5 Nm Do not exceed the specified time or temperature 11.5 limits during soldering. "Soldering" Please read Cautions and warnings and Important notes at the end of this document. Page 35 of 39 B41827, B43827 Standard series 85 C Topic Soldering, cleaning agents Passive flammability Active flammability Safety information Reference chapter "General technical information" Do not allow halogenated hydrocarbons to come 11.6 into contact with aluminum electrolytic capacitors. "Cleaning agents" Avoid external energy, such as fire or electricity. 8.1 "Passive flammability" Avoid overload of the capacitors. 8.2 "Active flammability" Breakdown strength Do not damage the insulating sleeve, especially of insulating when ring clips are used for mounting. sleeves Please read Cautions and warnings and Important notes at the end of this document. Page 36 of 39 Reference chapter "Capacitors with screw terminals" "Screw terminals accessories" B41827, B43827 Standard series 85 C Symbols and terms Symbol English German C CR CS CS,T Cf d dmax ESL ESR ESRf Capacitance Rated capacitance Series capacitance Series capacitance at temperature T Capacitance at frequency f Case diameter, nominal dimension Maximum case diameter Self-inductance Equivalent series resistance Equivalent series resistance at frequency f Equivalent series resistance at temperature T Frequency Current Alternating current (ripple current) Root-mean-square value of alternating current Ripple current at frequency f Maximum permissible ripple current Rated ripple current Rated ripple current for base cooling Leakage current Operating leakage current Case length, nominal dimension Maximum case length (without terminals and mounting stud) Resistance Insulation resistance Balancing resistance Temperature Temperature difference Ambient temperature Case temperature Capacitor base temperature Time Period Service life (operating hours) Kapazitat Nennkapazitat Serienkapazitat Serienkapazitat bei Temperatur T Kapazitat bei Frequenz f Gehausedurchmesser, Nennma Maximaler Gehausedurchmesser Eigeninduktivitat Ersatzserienwiderstand Ersatzserienwiderstand bei Frequenz f ESRT f I IAC IAC,rms IAC,f IAC,max IAC,R IAC,R (B) Ileak Ileak,op l lmax R Rins Rsymm T T TA TC TB t t tb Please read Cautions and warnings and Important notes at the end of this document. Ersatzserienwiderstand bei Temperatur T Frequenz Strom Wechselstrom Wechselstrom, Effektivwert Wechselstrom bei Frequenz f Maximal zulassiger Wechselstrom Nennwechselstrom Nennwechselstromstrom fur Bodenkuhlung Reststrom Betriebsreststrom Gehauselange, Nennma Maximale Gehauselange (ohne Anschlusse und Gewindebolzen) Widerstand Isolationswiderstand Symmetrierwiderstand Temperatur Temperaturdifferenz Umgebungstemperatur Gehausetemperatur Temperatur des Becherbodens Zeit Zeitraum Brauchbarkeitsdauer (Betriebszeit) Page 37 of 39 B41827, B43827 Standard series 85 C Symbol V VF Vop VR VS XC XL Z ZT tan 0 r English Voltage Forming voltage Operating voltage Rated voltage, DC voltage Surge voltage Capacitive reactance Inductive reactance Impedance Impedance at temperature T Dissipation factor Failure rate Absolute permittivity Relative permittivity Angular velocity; 2 f German Spannung Formierspannung Betriebsspannung Nennspannung, Gleichspannung Spitzenspannung Kapazitiver Blindwiderstand Induktiver Blindwiderstand Scheinwiderstand Scheinwiderstand bei Temperatur T Verlustfaktor Ausfallrate Elektrische Feldkonstante Dielektrizitatszahl Kreisfrequenz; 2 f Note All dimensions are given in mm. Please read Cautions and warnings and Important notes at the end of this document. Page 38 of 39 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FormFit, MiniBlue, MiniCell, MKK, MKD, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 39 of 39