Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 7916A Coax - Series 6 For more Information please call 1-800-Belden1 General Description: Series 6, 18 AWG solid .040" bare copper conductor, gas-injected foam polyethylene insulation, Duobond(R) + aluminum braid shields (60% and 40% coverage), PVC jacket (black or white). Usage (Overall) Suitable Applications: HDTV, DBS, Broadband CATV, Cable Modem Physical Characteristics (Overall) Conductor AWG: # Coax AWG Stranding Conductor Material Dia. (mm) 1 18 Solid BC - Bare Copper 1.016 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Dia. (mm) Gas-injected FPE - Foam Polyethylene 4.572 Outer Shield Outer Shield Material: Layer # Outer Shield Trade Name Type Outer Shield Material 1 Bonded Duofoil(R) 2 3 Duofoil(R) 4 Coverage (%) Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100 Braid AL - Aluminum 60 Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 Braid AL - Aluminum 40 Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 7.569 mm Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +80C Bulk Cable Weight: 49.111 Kg/Km Max. Recommended Pulling Tension: 462.613 N Min. Bend Radius/Minor Axis: 76.200 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CATV, CM CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes Page 1 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 7916A Coax - Series 6 EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Series Type: Series 6 Flame Test UL Flame Test: UL1685 UL Loading Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 7916AP Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 75.000 Nom. Inductance: Inductance (H/m) 0.318257 Nom. Capacitance Conductor to Shield: Capacitance (pF/m) 53.1522 Nominal Velocity of Propagation: VP (%) 83 Nominal Delay: Delay (ns/m) 3.9372 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 20.9984 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 15.7488 Nom. Attenuation: Freq. (MHz) Attenuation (dB/100m) 5 1.6405 55 4.5934 211 8.5306 500 13.4521 750 16.7331 862 18.0455 1000 19.686 1450 25.5918 1800 28.2166 2250 32.1538 3000 37.0753 Max. Attenuation: Page 2 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 7916A Coax - Series 6 Freq. (MHz) Attenuation (dB/100m) 5 2.19827 55 5.2496 211 9.41647 500 14.6989 750 18.3408 862 19.6204 1000 21.4577 1450 26.248 1800 28.8728 2250 32.81 3000 39.0439 Max. Operating Voltage - UL: Voltage 300 V RMS Shield Effectiveness: Start Freq. (MHz) Stop Freq. (MHz) Effectiveness (dB) 5 50 105 50 1000 110 Typical Structural Return Loss: Start Freq. (MHz) Stop Freq. (MHz) Typical SRL (dB) 5 1000 30 1000 3000 24 Minimum Structural Return Loss: Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB) 5 1000 20 1000 2250 15 2250 3000 10 Sweep Test Sweep Testing: 5 MHz - 3 GHz Notes (Overall) Notes: Shielding effectiveness determined from screening attenuation measurement when tested in accordance with IEC 61196-1. Put Ups and Colors: Item # Putup Ship Weight Color 7916A 009U1000 305 MT 16.329 KG WHITE Notes Item Desc 7916A 009U500 152 MT 8.391 KG WHITE 7916A 0091000 305 MT 15.876 KG WHITE C #18 LDPE/GIFHDLDPE DBSH FRPVC 7916A 009500 152 MT 8.845 KG WHITE C #18 LDPE/GIFHDLDPE DBSH FRPVC 7916A 010U1000 305 MT 16.329 KG BLACK 7916A 010U500 152 MT 8.391 KG BLACK 7916A 0101000 305 MT 15.876 KG BLACK C #18 LDPE/GIFHDLDPE DBSH FRPVC 7916A 010500 152 MT 8.845 KG BLACK C #18 LDPE/GIFHDLDPE DBSH FRPVC 7916A 0105000 1,524 MT 86.183 KG BLACK C #18 LDPE/GIFHDLDPE DBSH FRPVC #18 LDPE/GIFHDLDPE DBSH FRPVC #18 LDPE/GIFHDLDPE DBSH FRPVC #18 LDPE/GIFHDLDPE DBSH FRPVC #18 LDPE/GIFHDLDPE DBSH FRPVC Notes: C = CRATE REEL PUT-UP. Revision Number: 5 Revision Date: 08-13-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, Page 3 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 7916A Coax - Series 6 exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 4 of 4 10-30-2013