For more Information
please call
1-800-Belden1
General Description:
Surveillance, CATV & MATV Cable, RG6, Rated-CM, 18 AWG solid bare copper, foamed polyolefin core,
Quad Shield-Duofoil®+60% aluminum braid+Duofoil®+40% aluminum braid, PVC jacket
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
118 Solid BC - Bare Copper 1.016
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
Gas-injected FPE - Foam Polyethylene 4.572
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
2Braid AL - Aluminum 60
3Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
4 Braid AL - Aluminum 40
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 7.569 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +80°C
UL Temperature Rating: 75°C
Bulk Cable Weight: 50.599 Kg/Km
Max. Recommended Pulling Tension: 462.613 N
Min. Bend Radius/Minor Axis: 76.200 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CM
NEC Articles: 800, 820
CEC/C(UL) Specification: CM
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Page 1 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
5339Q5 Coax - CATV and MATV Applications
MII Order #39 (China RoHS): Yes
Other Specification: NEC/UL type CATV
RG Type: 6/U
Series Type: Series 6
Flame Test
UL Flame Test: UL1685 UL Loading
C(UL) Flame Test: FT1
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 6339Q8
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
75
Nom. Inductance:
Inductance (µH/m)
0.318257
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
53.4803
Nominal Velocity of Propagation:
VP (%)
83
Nominal Delay:
Delay (ns/m)
3.97001
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
21.3265
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
22.967
Max. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
52.65761
55 5.2496
211 10.1055
270 11.4835
300 12.1397
330 12.7631
400 14.1083
450 15.027
550 16.7003
750 19.686
870 21.3265
1000 22.967
Max. Operating Voltage - Non-UL:
Voltage
350 Vrms
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
5339Q5 009U1000 1,000 FT 37.000 LB WHITE C RG-6 QUAD SHIELD COAX
5339Q5 009U500 500 FT 19.000 LB WHITE RG-6 QUAD SHIELD COAX
5339Q5 0091000 1,000 FT 37.000 LB WHITE C RG-6 QUAD SHIELD COAX
5339Q5 010U1000 1,000 FT 37.000 LB BLACK RG-6 QUAD SHIELD COAX
5339Q5 0101000 1,000 FT 37.000 LB BLACK C RG-6 QUAD SHIELD COAX
Notes:
C = CRATE REEL PUT-UP.
Page 2 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
5339Q5 Coax - CATV and MATV Applications
Revision Number: 1 Revision Date: 05-13-2013
© 2015 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
5339Q5 Coax - CATV and MATV Applications