WaveJet 300A Oscilloscopes
100 MHz–500 MHz
Portable Performance for
Debug and Validation
2
A UNIQUE TOOLSET FOR PORTABLE OSCILLOSCOPES
Key Features
100 MHz, 200 MHz,
350 MHz and 500 MHz
bandwidths
Sample rates up to 2 GS/s
Long waveform memory
– 500 kpts/Ch
26 measurement
parameters
Replay history mode
7.5” color display
Multi-language user-
interface and help
USB Host and Device
connections for printers,
memory sticks and PC
remote control
Available GPIB and LAN
connectivity
The WaveJet 300A provides
the banner specifications,
feature set and user interface
to simplify how you work and
shorten debug time. With a
big, bright 7.5” display, long
500 kpts/Ch memory and
up to 2 GS/s you will easily
capture and see every detail
of your waveform. The USB
ports provide a quick way
to save waveforms, store
or print screen captures or
connect to a PC. Math and
measurement tools help you
understand the waveforms
and Replay mode allows
you to look at a history of
what has been captured.
Altogether these specs,
features and capabilities make
the WaveJet 300A the right
oscilloscope for your
debugging needs.
Advanced
Triggering
Along with edge
triggering, additional
triggering capabilities
include Pulse Width,
Period, Pulse Count
and TV to help you
capture the signals
you need to see.
Frequency
Counter
Use the built-in 6-digit
frequency counter to
Long Capture Time
The 500 kpts/Ch memory eliminates
the tradeoff between long capture
and high sample rate providing long
capture at full 2 GS/s sample rate.
The long memory makes the WaveJet
a great tool for viewing low frequency
and high frequency signals or signals
with fast edges.
3
A UNIQUE TOOLSET FOR PORTABLE OSCILLOSCOPES
The rear panel USB port, along
with optional GPIB and Ethernet
connections provide full remote
control of the instrument. Teledyne
LeCroy’s Scope Explorer and
ActiveDSO software utilities
provide a quick method to begin
controlling the WaveJet.
Connectivity and
Communication
Saving waveforms and screen
images is an important part of
documenting results. The WaveJet
has a front panel USB port to save
data to memory stick and a rear
panel USB for printing hardcopies.
simplify how you make measurements.
The counter is always displayed and
easy to read.
Acquisition Modes
Peak detect and equivalent time
acquisition modes offer flexibility
in how you capture and measure
your signals. The WaveJet can
capture glitches as small as 1 ns
with peak detect and can achieve
a sampling rate of up to100 GS/s
with equivalent time sampling.
Waveform Math
The WaveJet provides math
capabilities for additional analysis.
Available math functions include
sum, difference, product and FFT.
Measurements can then be made
on the calculated waveforms
using the parameters or cursors
to provide additional debug and
analysis capabilities.
Automatic Measurements
Save time making measurements
on your signals by using the 26
automatic measurement parameters.
See your results color coded to
the channels that are being measured.
For a more in-depth look turn on the
min/max statistics to observe trends
in the measurements.
Replay Mode
The fast update rate shows runts
and glitches when they occur but
it is hard to tell exactly when they
occurred. Replay mode lets you
go back in time to isolate those
anomalies, measure them with
parameters or cursors, and quickly
find the source of the problem.
4
INTUITIVE USER INTERFACE SIMPLIFIES HOW YOU WORK
The WaveJet 300A Series offers
a set of features and capabilities
not typically found in a portable
oscilloscope. Its small form
factor includes a big, bright
7.5” display as well as, USB,
GPIB and Ethernet connectivity.
1
3
2
1. Display
The 7.5” VGA display allows you to
easily view signal details. It also
provides room to display measurements
and menus without cluttering the
waveform grid.
2. Power Up Time
The WaveJet is on and ready to
use in less than 3 seconds.
3. Connectivity
Documenting your work is easy using
the front-mounted USB port on the
WaveJet. Simply press the Print button
on the front panel to quickly save screen
images to your USB memory device.
5
INTUITIVE USER INTERFACE SIMPLIFIES HOW YOU WORK
4. Portability
The small 4” footprint and light weight
of the WaveJet means it is easy to
carry and use anywhere, even when
bench space is limited.
5. Auto Setup
Quickly configure vertical, horizontal,
and trigger settings with a single
button press.
6. Intensity/Replay Control
Rotate to control waveform intensity,
or push to toggle to Replay mode. In
Replay mode, rotate this knob to see
a history of waveforms captured by
the WaveJet.
7. Active Channel Indicators
These channel LEDs are color matched
to each waveform on the display. The
active channel for the vertical controls
is always lit to simplify operation.
8. Push Knobs
Push the Offset knob to automatically
zero the channel offset, or the Delay
knob to automatically center the trigger
point on the screen.
9. Local Language User
Interface
Select from 9 different language
preferences.
5
4
6
78
6
6
A. Fast Update Rate Shows Rare Events
The fast acquisition lets you see that a runt
pulse has occurred, but more information is
needed to understand the problem
B. Isolate the
Problem
Go back in time to
look at the history of
your waveform. The
runt pulse has been
isolated and now it
can be measured.
C. Understand the
Anomaly
Looking back over
1024 consecutive
acquisitions allows
you to see recurring
problems and to
understand if they
occur in a predictable
pattern.
D. Solve the
Problem
Use Replay to help
you understand
the cause of the
problem by seeing
what comes
before or after
the runt pulse.
Up to 1024 Waveforms in Replay memory
Most engineers and technicians will agree that
it is important to see waveforms updating
rapidly in order to see rare events or signal
anomalies. These rare events show up
briefly and then fade away. But with
WaveJet you can easily capture
them for a closer look. The
oscilloscope’s fast update
rate of up to 3600 wfms/s
combines with Replay
Mode to go back in time
to isolate and measure
the anomaly.
REPLAY MODE ISOLATES RARE EVENTS
7
ACCESSORIES
7
The WJ-CASE Accessory
The small form factor of the
WaveJet makes it convenient
to move from lab to lab or
from the lab in to the field.
The WJ-CASE accessory serves
as both a carrying case with
shoulder strap (not shown) and
a protective front cover. Simply
slide the WaveJet in to the case and snap on the front cover
for transport, when it is time to use the WaveJet remove the
front cover and operate the WaveJet while it is still in the case.
To make sure you do not lose the front cover turn it around and
snap it on to the case from behind.
LogicStudio 16
The WaveJet can be paired with Teledyne LeCroy’s LogicStudio 16 to turn your PC into a mixed signal oscilloscope
with tools for capturing, viewing and measuring analog, digital and serial signals in one place. LogicStudio offers 16
channels, 100 MHz and up to 1 GS/s logic analysis with I2C, SPI and UART triggering and decoding which can all be
displayed alongside the analog waveforms captured on WaveJet. When only digital debug is needed disconnect the
WaveJet and use LogicStudio as a stand alone logic analyzer.
SPECIFICATIONS AND ORDERING INFORMATION
Product Description Product Code
Included with Standard Configuration
One Passive Probe per Channel
Multi-language User Interface (English, Chinese, French,
German, Italian, Japanese, Korean, Russian and Spanish)
Getting Started Manual and Quick Reference Guide
Rear Panel USB Port for Remote Control and Printing
Calibration and Performance Certificate
3-year Warranty
Accessories
GPIB Interface for WaveJet 300A Series WJ-A-GPIB
10/100Base-T Interface for WaveJet 300A Series WJ-A-LAN
WaveJet Carrying Case and Protective Front Cover WJ-CASE
16 Channel, 1 GS/s, 100 MHz USB Logic Analyzer LogicStudio 16
Local sales offices are located throughout the world.
Visit our website to find the most convenient location.
© 2009 by Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to
change without notice. Product or brand names are trademarks or requested trademarks of their respective holders.
1-800-5-LeCroy
teledynelecroy.com
WJADS-12feb13
Product Description Product Code
WaveJet 4-Channel/2-Channel Oscilloscopes
500 MHz, 1 GS/s, 4 Ch, 500 kpts/Ch WaveJet 354A
with 7.5” Color Display. 2 GS/s Interleaved
350 MHz, 1 GS/s, 4 Ch, 500 kpts/Ch WaveJet 334A
with 7.5” Color Display. 2 GS/s Interleaved
200 MHz, 1 GS/s, 4 Ch, 500 kpts/Ch WaveJet 324A
with 7.5” Color Display. 2 GS/s Interleaved
200 MHz, 1 GS/s, 2 Ch, 500 kpts/Ch WaveJet 322A
with 7.5” Color Display. 2 GS/s Interleaved
100 MHz, 1 GS/s, 4 Ch, 500 kpts/Ch with 7.5” Color Display WaveJet 314A
100 MHz, 1 GS/s, 2 Ch, 500 kpts/Ch WaveJet 312A
with 7.5” Color Display
Customer Service
Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties,
our digital oscilloscopes are fully warranted for three years, and our probes are warranted for one year.
This warranty includes: No charge for return shipping Long-term 7-year support Upgrade to latest software at no charge
WaveJet WaveJet WaveJet WaveJet WaveJet WaveJet
314A 312A 324A 322A 334A 354A
Bandwidth 100 MHz 200 MHz 350 MHz 500 MHz
Rise Time 3.5 ns 1.75 ns 1 ns 750 ps
Input Channels 4 2 4 2 4 4
Display 7.5” Color flat-panel TFT-LCD, 640 x 480 VGA
Sampling Rate (single-shot) 1 GS/s 2 GS/s (Interleaved), 1 GS/s (all channels)
Sampling Rate (RIS) 100 GS/s
Peak Detect Period 1 ns
Memory Length 500 kpts/Ch (all channels)
Capture Time 500 µs at 1 GS/s, 250 µs at 2 GS/s
Vertical Resolution 8-bit
Vertical Sensitivity 2 mV/div–10 V/div 2 mV/div–10 V/div, 2 mV/div–2 V/div (50
Ω
)
Vertical (DC) Gain Accuracy ± (1.5% + 0.5% of full scale)
BW Limiting Filters 20 MHz 20 MHz, 200 MHz
Maximum Input Voltage 400 V CAT I 400 V CAT I, 5 Vrms (50
Ω
)
Input Coupling GND, DC 1 M
Ω
, AC 1 M
Ω
GND, DC 1 M
Ω
, AC 1 M
Ω
, DC 50
Ω
Input Impedance
1 M
Ω
±1.5%|| 20 pF
1 M
Ω
±1.5%|| 16 pF, 50
Ω
±1.5%
Probing System BNC with Probe Sense Ring
Probes PP010 (One per channel) PP006A (One per channel)
Timebase Range 5 ns/div–50 s/div 2 ns/div–50 s/div 1 ns/div–50 s/div 500 ps/div–50 s/div
Roll Mode 50 ms/div–50 s/div (100 kS/s maximum)
Timebase Accuracy 10 ppm (typical)
Triggering
Triggers Edge, Glitch, Period, Pulse Count, TV
Measure, Zoom, Math and Replay
Measure Base, Cycle Mean, Cycle RMS, Duty Cycle, Fall Time (90-10%), Fall Time (80-20%), Frequency, Integral, Maximum,
Mean, Minimum, Number of +Pulses, Number of -Pulses, +Overshoot, -Overshoot, Peak-Peak, Period, +Pulse Width,
-Pulse Width, Rise Time (20–80%), Rise Time (10–-90%), RMS, Skew, Skew@level, Top, Top-Base
Zoom Use the front panel QuickZoom button to zoom all waveforms in a separate zoom grid.
Math Sum, Difference, Product, FFT (up to 8 kpts with Rectangular, Von Hann, or Flat Top)
Replay Look back at the history of waveform acquisitions (maximum 1024 acquisitions)
Physical Dimensions
Dimensions (HWD) 190 mm x 285 mm x 102 mm (7.5” x 11.2” x 4”)
Net Weight 3.2 kg; 7 lbs.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Teledyne LeCroy:
WaveJet 312-A WaveJet 314-A WaveJet 322-A WaveJet 332-A WaveJet 334-A WaveJet 352-A WaveJet 354-A