The “PC60”, “MB60” & “SW60”
are a new family of miniature
direct current contactors and
solenoid switches which are
designed to fill the gap between
30 ampere relays and 100
ampere contactors.
The family is divided into two distinct
branches, PC60/MB60 for printed circuit board
mounting and SW60 free standing contactors and each has
its own selection of variations and options.
These are unique designs for printed circuit board mounting
and the following variations and configurations are
available:
80 Ampere
Miniature
Direct Current
Contactors
PC SERIES
PCB MOUNTING
MINIATURE DC CONTACTORS
2
The Use of
Miniature DC
Contactors
The “PC”, “MB” & “SW”
contactors represent a
novel dual approach to
the requirements for DC
contactors.
On the one hand the
expansion of
Telecommunications Systems,
UPS and other Power
Conversion Systems has
led to a demand for
compact, easily installed
and economically priced
contactors which up until
now have not been available.
With the introduction of the
“PC60” & “MB60” contactors,
this demand has now been
effectively met.
On the other hand the “SW60”
range fulfills the requirements
for more traditional DC
contactor applications:
switching or reversing small
traction motors, hydraulic
power packs, small electric
winch motors, etc.
All the contactors are
manufactured to a very high
standard and employ best
quality materials: phenolic
contact housings, silver alloy
contacts and Class H (180°C)
winding wire for the coils.
Silver plated heavy current and
gold plated light current
components are also used on
the “PC60” & “MB60”
contactors.
These new contactors are a
unique and innovative
introduction from the world’s
leading manufacturer of DC
contactors.
Magnetic Blowouts PC60B, PC61B & PC63B
The contactors can be fitted with magnetic blowouts for switching
current at higher dc voltages (guide: >60V for resistive loads and
>48V for inductive loads).
If the application calls for frequent switching under these conditions, it
is recommended that a contact housing with open apertures is
specified. This is available as a no cost option.
When fitted with magnetic blowouts it is important that the correct
polarity for the main terminal connections is observed.
Auxiliary Contacts PC60A, PC61A & PC63A
A double circuit changeover 5 ampere microswitch auxiliary contact
can be provided.
This is fitted in a purpose designed holder with gold plated pickups for
the microswitch terminals and pins for soldering direct to a printed
circuit board.
TYPE NO. DESCRIPTION
PC60 Single Pole On/Off
Normally Open Contactor (SP ST NO)
PC61 Single Pole Changeover Contactor
(SP DT)
PC63 Single Pole On/Off
Normally Closed Contactor (SP ST NC)
PC60