MIL-PRF-39018/3G
8
Life: Method 108 of MIL-STD-202.
For qualification: Condition F (2,000 hours) at +85°C.
DCL: See table I.
∆Cap.: W ithin ±10 percent of initial measured value.
ESR: Not more than 130 percent of initial requirement.
For conformance: Performance check, condition B (250 hours) at +85°C (non-ER).
DCL: See table I.
∆Cap.: W ithin ±10 percent of initial measured value.
ESR: See table I.
For conformance: Continuation test (1,750 hours) at +85°C (non-ER).
DCL: See table I.
∆Cap.: W ithin ±15 percent of initial measured value.
ESR: Not more than 130 percent of initial requirement.
For quality conformance: 10,000 hours (ER) at +85°C.
DCL: At +25°C initial limit, at +85°C, 125 percent of initial limit.
∆Cap.: W ithin ±25 percent of initial measured value.
ESR: Not more than 200 percent of initial requirement.
Case insulation (CU17 and CUR17 only): In accordance with MIL-PRF-39018.
Vibration:
Low frequency: In accordance with MIL-PRF-39018.
High frequency: (When specified, see ordering data): In accordance with MIL-PRF-39018 with the following
exceptions: Test condition letter A; duration and direction of motion - In accordance with
method 204 of MIL-STD-202.
Random (style CUR17 only): In accordance with MIL-PRF-39018.
Thermal shock and immersion:
Thermal shock: Method 107 of MIL-STD-202, condi tion A, except in step 3, units shall be tested at applicable
high temperature.
Immersion: Method 104 of MIL-STD-202, condition B (2 cycles, 30 minutes).
DCL: See table I.
∆Cap.: Within ±5 percent of initial measured value.
ESR: See table I.
Case insulation (CU17 and CUR17 only): Shall meet initial requirement.
Surge voltage:
DCL: See table I.
∆Cap.: W ithin ±6 percent of initial measured value.
ESR: See table I.
Moisture resistance:
Method 106 of MIL-STD-202.
DCL: See table I.
∆Cap: Within ±6 percent of initial measured value.
ESR: See table I.
Case Insulation (CU17 and CUR17 only): Shall meet initial requirement.
High temperature exposure (500 hours at +105°C):
DCL: Not more than 200 percent of initial requirement.
∆Cap.: W ithin ±10 percent of initial measured value.
ESR: Not more than 115 percent of initial requirement.