Input and Output Impedance
The impedance of both the input source and the load will
interact with the impedance of the product. It is important that
the input source has low characteristic impedance. The
products are designed for stable operation without external
capacitors connected to the input or output. The performance
in some applications can be enhanced by addition of external
capacitance as described under External Capacitors. If the
input voltage source contains significant inductance, the
addition of a 470 µF capacitor with low ESR at the input of the
product will ensure stable operation.
External Decoupling Capacitors
Input capacitors:
The recommended input capacitor has a minimum
capacitance of 470 µF and a low ESR. The ripple current
rating of the capacitor must be at least 4 A rms. For high-
performance/transient applications or wherever the input
source performance is degraded, additional low ESR ceramic
type capacitors at the input is recommended. The additional
input low ESR capacitance above the minimum level insures
an optimized performance.
Output capacitors:
The recommended output capacitor has a minimum
capacitance of 470 µF and a low ESR. When powering loads
with significant dynamic current requirements, the voltage
regulation at the point of load can be improved by addition of
decoupling capacitors at the load.
The most effective technique is to locate low ESR ceramic and
electrolytic capacitors as close to the load as possible, using
several capacitors in parallel to lower the effective ESR. The
ceramic capacitors will handle high-frequency dynamic load
changes while the electrolytic capacitors are used to handle
low frequency dynamic load changes. Ceramic capacitors will
also reduce high frequency noise at the load.
It is equally important to use low resistance and low
inductance PCB layouts and cabling.
External decoupling capacitors are a part of the control loop of
the product and may affect the stability margins. The ESR of
the capacitors is a very important parameter. Stable operation
is guaranteed for an ESR value of >5 m and a total
capacitance in the range defined in the electrical specification.
For a total capacitance outside this range or with lower ESR a
re-configuration will be necessary for robust dynamic
operation and stability. Please contact your local Ericsson
Power Modules representative for custom configurations.
Control Loop Compensation
The product is configured with a robust control loop
compensation which allows for a wide range operation of input
and output voltages and capacitive loads as defined in the
electrical specification. Please contact your local Ericsson
Power Modules representative for custom configurations.
Load Transient Respo nse Optimization
The product incorporates a Non-Linear transient Response,
NLR, loop that decreases the response time and the output
voltage deviation during a load transient. The NLR results in a
higher equivalent loop bandwidth than is possible using a
traditional linear control loop. The product is pre-configured
with appropriate NLR settings for robust and stable operation
for a wide range of input voltage and a capacitive load range
as defined in the electrical specification. For a specific input
voltage, and capacitive load, the NLR and control loop
compensation configuration can be optimized for a robust and
stable operation and with an improved load transient
response. Please contact your local Ericsson Power Modules
representative for custom configurations.
Remote Sense
The product has remote sense that can be used to
compensate for voltage drops between the output and the
point of load. The sense traces should be located close to the
PCB ground layer to reduce noise susceptibility. The remote
sense circuitry will compensate for up to 10% voltage drop
between output pins and the point of load.
If the remote sense is not needed +S should be connected to
VOUT and S should be connected to GND.
Output Voltage Adjust Range
With Analog Output Voltage Adjust the output voltage can be
set by an external resistor, RSET, which is applied between the
FLEX pin and the S pin.
Analog output voltage adjust with external resistor.
FLEX
−S
RSET
BMR 450
DC/DC Regulators, Input 4.5-14 V, Output 20 A/100 W
EN/LZT 146 400 R1C November 2008
© Ericsson AB
Technical Specifi cation