4 3 WG NO. SH T REV. 1 CS$122-1 tIN/C This print and associated documents and the contained REVISIONS information are the confidential property of ELECTRONIC N REV. DESCRIPTION APROVED CABLE SPECIALISTS. Disclosure of, and/or reproduction INST) Tl INST T ECN | ZONE | REV. pare of, all or. part thereof er manufacture of any part trom 12898; IN/C]_NEW_ RELEASE. ardor le information contained on this print not specifically per mitted by ELECTRONIC CABLE SPECIALISTS in writing is forbidden. FERRULE [ Lso| BODY LONTACT Ce ot DIMENSIONS /4\ SPECIFICATIONS ELECTRICAL IMPEDANCE: 50 OHMS NOMINAL FREQUENCY RANGE: 0-18 GHz VSWR: 1.05 + .05(FGHz) dB MAX INSERTION LOSS: .03 \FGHz dB MAX WORKING VOLTAGE: 500 VRMS SEA LEVEL DIELECTRIC WITHSTANDING: 1500 VRMS @ SEA LEVEL INSULATION RESISTANCE: 5000 MEGOHMS MINIMUM @ 500 VOLTS OC MECHANICAL CONNECTOR INTERFACE DIMENSIONS PER MIL~STD~348A, FIGURE 310+1 (SMA) TERMINATION STYLE: INNER CONTACT-SOLDER OR CRIMP OUTER CONTACTFERRULE CRIMP CABLE RETENTION: 50 LBS ENVIRONMENTAL TEMPERATURE RATING: VIBRATION: MIL~STD-202, METHOD 204, COND. 8 SHOCK: MiL~STD-202, METHOD 213, COND. | THERMAL SHOCK: MIL-STD~202, METHOD 107, COND. B CORROSION: MIL-STD-202, METHOD 101, COND. B MOISTURE RESISTANCE: MIL-STD-202, METHOD 106 MATERIALS BODY: STAINLESS STEEL PER SAE~AMS~QQ-S-763 FERRULE: ANNEALED, BRASS PER ASTM B16 OR COPPER PER ASTM 8124 CENTER CONTACT: BERYLLIUM COPPER PER ASTM B196 DIELECTRIC: TEFLON PER ASTM D1710 GASKET: SILICON RUBBER PER ZZ-R-765 FINISHES BODY: PASSIVATED FERRULE: BRIGHT NICKEL PER QQN290 CENTER CONTACT: GOLD PER MiL-~G45204 -65' TO +165 C 1, 2. 3. 6. 7. BEGIN BY CUTTING THE CABLE OFF SQUARE. 1 WHEN USING AUTOMATIC STRIPPING EQUIPMENT, STRIP CABLE AS SHOWN STARTING WITH L1 AND ENDING WITH L3. TAKE CARE NOT TO NICK THE CONDUCTORS WHILE STRIPPING THE DIELECTRIC AND JACKET. NOT AVAILABLE, STRIP ONLY Lt AND L3 AND TRIM EXCESS BRAIO AT STEP 10. Lo 2.19 | ~L2 = .31 -L3 = .62 SUDE THE FERRULE AND ADHESIVE SHRINK TUBING OVER THE END OF THE CABLE. =| |r SOLDER THE CONTACT ONTO THE CENTER CONDUCTOR, PER MIL-STOD-2000, USING 63Sn/37Pb SOLDER OR CRIMP WITH _M22520/557 DIE (B HEX). ENSURE THE CONTACT IS BUTTED AGAINST CABLE DIELECTRIC. CLEAN ALL FLUX RESIDUES USING AN APPROPRIATE FLUX CLEANER. USING TWEEZERS, FOLD THE OUTER BRAID BACK OVER THE CABLE JACKET, LEAVING AS MUCH WEAVE AS POSSIBLE. =| | m- SLICE THE ALUMINUM/POLYESTER FOIL LENGTHWISE ABOUT EVERY 1/8. BRAID AND ALUMINUM/POLYESTER FOIL FROM THE DIELECTRIC. USING TWEEZERS, FOLD BACK ALUMINUM/POLYESTER FOIL OVER THE OUTER BRAID. i [Bats USING TWEEZERS, FOLD THE INNER BRAID BACK OVER THE OTHER SHIELDS, LEAVING AS MUCH WEAVE AS POSSIBLE. NOTE: DO NOT UNRAVEL DIELECTRIC WHEN PULLING BACK INNER SHIELO. en | | 8k GENTLY ROTATE PIN TO SEPARATE THE FLAT FOIL 8. SUIDE THE BODY OF THE CONNECTOR OVER THE END OF THE CABLE UNTIL THE NOTCH IN THE CONTACT SEATS WITH THE DIELECTRIC RIDGE INSIDE THE CONNECTOR BODY. 1F AUTOMATIC STRIPPING EQUIPMENT IS 10. SLIDE THE FERRULE UP OVER THE SHIELDS AND AGAINST THE CONNECTOR BODY. TRIM AWAY ANY EXCESS BRAID. CRIMP THE FERRULE ONCE, NEXT TO THE BODY, USING THE M22520/5-47 (A HEX) IN A M22520/501 TOOL FRAME. APPLY ADHESIVE HEAT SHRINK. A NOTES 1. ALL DIMENSIONS ARE IN INCHES. A ENSURE HEAT SHRINK IS INSTALLED PRIOR TO CRIMPING CONNECTOR. Ay ADHESIVE HEAT SHRINK SHOULD BE APPLIED IN ACCORDANCE WITH ECS WORK INSTRUCTION WIOO7. CONTACT ECS FOR A COPY OF THIS WORK INSTRUCTION. /\ CONNECTOR DIMENSIONS ARE FOR REFERENCE ONLY. 5. PICTORIALS SHOW CONNECTOR INSTALLATION ON ECS 311201 CABLE. WHEN INSTALLING THIS CONNECTOR ON 421201 THERE ARE ONLY 2 SHIELDS WHICH SHOULD BE FOLDED BACK AS SHOWN IN STEP 6 AND STEP 7 WOULD BE OMITTED. ALL LENGTHS IN INCHES > ELECTRONIC CABLE SPECIALISTS Eqe PHONES Cons) 42) 8300 m1] CUSTOMER SPECIFICATION Ln as or/ec/e) SMA STRAIGHT PLUG FOR ECS CABLE @ hysvcanr | V4/oi 311201 AND 421201 O&SGNeD &y: SIZE CAGE CODE LEVEL | PART NO, =~ Bj66197;C CSS122 Pe Ey quo! SCALE: | mux wo FAE\SPEC\CONM\WST\CS8122 | SHEET 1 OF 4 3 2 1