Solid State Relay G3MC Compact, Thin-profile, Low-cost SSR with Reinforced Insulation * Small bottom surface area (approx. 80% of the conventional G3MB's), ideal for close PCB mounting. * DC input and AC output for an applicable load of 1A at 40C. * Compact, thin-profile SSR of monoblock construction with an all-in-one frame incorporates a PCB, terminals, and a heatsink. * Approved by UL and CSA. VDE certified models available. * Models with reinforced insulation are available. Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G3MC-101P-DC12). Isolation Phototriac Zero-cross function Yes Built-in snubber circuit Yes Rated output load 1 A at 100 to 120 VAC (75 to 132 VAC) Rated input voltage 5 VDC Part number G3MC-101P 12 VDC 24 VDC No 5 VDC G3MC-101PL 12 VDC 24 VDC Yes 2 A at 100 to 240 VAC (75 to 264 VAC) 5 VDC G3MC-202P 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC Note: 1. All models meet UL and CSA standards. In order to obtain VDE approved versions with UL, CSA and VDE Logos, add "-VD" to the part number. Example: G3MC-101P-VD-DC12 2. 2A models are available with reinforced insulation. Add "-1" to the part number to obain 2A models with reinfored insulation. Examples: G3MC-202PL-1-DC5 G3MC-202P-VD-1-DC24 Solid State Relay G3MC 401 Specifications Ratings (Ambient temperature 25C) Input Rated voltage Operating voltage Impedance Voltage levels Must operate voltage 5 VDC 4 to 6 VDC 300 20% 4 VDC max. 12 VDC 9.6 to 14.4 VDC 800 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 1.6k 20% 19.2 VDC max. Must dropout voltage 1 VDC min. Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions. Output Part number Applicable load Rated load voltage Load voltage range Load current Surge current G3MC-101P(L)(-VD) 100 to 120 VAC, 50/60 Hz 75 to 132 VAC, 50/60 Hz 0.1 to 1 A 8 A (60 Hz, 1 cycle) G3MC-202P(L)(-VD)(-1) 100 to 240 VAC, 50/60 Hz 75 to 264 VAC, 50/60 Hz 0.1 to 2 A 30 A (60 Hz, 1 cycle) Characteristics Item G3MC-101P(-VD) G3MC-101PL(-VD) Operate time 1/2 of load power source cycle + 1 ms 1 ms max. Release time 1/2 of load power source cycle + 1 ms) Output ON voltage drop 1.6 V (RMS) max. Leakage current 1 mA max. (at 100 VAC) Insulation resistance 1,000 M min. (at 500 VDC) G3MC-202P(-VD)(-1) 1/2 of load power source cycle + 1 ms G3MC-202PL(-VD)(-1) 1 ms max. 1.5 mA max. (at 200 VAC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min (3,000 VAC, 50/60 Hz for 1 min. for G3MC-@@@-VD-1) Vibration resistance Malfunction: 10 to 55 Hz, 0.75-mm double amplitude Shock resistance Malfunction: 1,000 m/s2 (approx. 100G) Ambient temperature Operating:-30C to 80C (with no icing or condensation) Storage:-30C to 100C (with no icing or condensation) Approved standards UL File No. E64562, CSA File No. LR35535 EN60950 File No. 5925UG ("-VD(-1)" type) Ambient humidity Operating: 45% to 85% Weight Approx. 2.5g (Approx. 5g for G3MC-202P(L)-VD-1) 402 Solid State Relay G3MC Engineering Data G3MC-101P(L)(-VD) Load Current vs. Ambient Temperature Characteristics Inrush Current Resistivity One cycle, non-repetitive (Keep the inrush current to half the rated value if it occurs repeatedly.) 1.2 Peak inrush current (A) Load current (A) 1.0 0.8 0.6 0.4 0.2 0 -30 -20 0 20 40 60 80 100 Energized time (ms) Ambient temperature (C) G3MC-202P(L)(-VD)(-1) Load Current vs. Ambient Temperature Characteristics Inrush Current Resistivity One cycle, non-repetitive (Keep the inrush current to half the rated value if it occurs repeatedly.) 2.0 Peak inrush current (A) Load current (A) 2.5 1.5 1.0 0.5 0 -30 -20 0 20 25 40 60 80 Ambient temperature (C) 100 Energized time (ms) Solid State Relay G3MC 403 Dimensions Units: mm (inch) G3MC-101P(L)(-VD) PCB Dimensions (Bottom View) 4.5 max. Four, 1.0-dia. holes 24.5 max. 13.5 max. 0.8 3.5 2.54 0.25 4-1.6 4-0.7 10.16 1.2 7.62 2.54 Terminal Arrangement (Bottom View) G3MC-202P(L)(-VD)(-1) 4.5 max. 24.5 max. PCB Dimensions (Bottom View) Four, 1.0-dia. holes 20.5 max. 0.8 3.5 2.54 0.25 4-1.6 4-0.7 10.16 2.54 404 Solid State Relay G3MC 7.62 1.2 Terminal Arrangement (Bottom View) Precautions General Precautions Do not touch the terminals of the SSR while power is being supplied to the SSR. The terminals are charged with the power, and an electric shock may be received by touching the terminals. The built-in capacitor may have a residual voltage after the SSR is turned off. Be sure to discharge the residual voltage before touching the terminals of the SSR, otherwise an electric shock may be received. Mounting 1. Make sure that no excessive voltage or current is imposed on or flows to the input or output circuit of the SSR, otherwise the SSR may malfunction or burn. 2. Solder the terminals of the SSR properly under the required soldering conditions. The SSR may be abnormally heated and burn if power is supplied to the terminals soldered incorrectly. 3. Do not short-circuit the load of the SSR while power is supplied to the SSR. Do not short-circuit the power supply through the SSR. The SSR may be damaged, malfunction, or burn if the load or power supply is short-circuited. Protective element No overvoltage absorption element is built in. Therefore, if the G3MC is connected to an inductive load, be sure to connect the overvoltage absorption element. G3MC-@@@PL (without Zero cross function) Phototriac Load Input Power supply G3MC-@@@P (with Zero cross function) Correct use The terminals of the SSR are highly heat-conductive. Each terminal must be soldered within 10 s at 260C or within 5 s at 350C. Protective element (MOV) Phototriac Load Protective element (MOV) Input Power supply The SSR is of a thin-profile construction. To maintain the vibration resistance of the SSR, make sure that the space between the SSR and PCB is 0.1 mm maximum. Lifting of the PCB can be prevented by setting the hole diameter of the PCBs on both sides slightly smaller than the actual terminal dimension. Select the model without the zero-cross function when using the Unit for phase control output. The casing works as a heat sink. When mounting two or more Units closely, make sure that the Units are properly ventilated by taking ambient temperature rises into consideration. If Units are closely mounted and used in places with no ventilation, the load current of each Unit must be 1/2 of the rated load current. Solid State Relay G3MC 405 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 Global - http://www.omron.com USA - http://www.components.omron.com 847-882-2288 Cat. No. X301-E-1b Solid State Relay 09/11 G3MC Specifications subject to change without notice Printed in USA Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G3MC-202P-DC5 G3MC-101PL-DC12 G3MC-101P-DC12 G3MC-101PL-DC24 G3MC-101P-DC5 G3MC-101PLDC5 G3MC-202P-DC12 G3MC-202P-DC24 G3MC-101PL-VD DC12 G3MC-101PL-VD DC24 G3MC-101PL-VD DC5 G3MC-101P-VD DC12 G3MC-101P-VD DC24 G3MC-101P-VD DC5 G3MC-202P-VD DC5 G3MC-202P-VD DC12 G3MC-202P-VD DC24 G3MC-202P-VD-1 DC12 G3MC-202P-VD-1 DC24 G3MC-202P-VD-1 DC5