Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8446 Multi-Conductor - Audio, Control, Communication and Instrumentation Cable For more Information please call 1-800-Belden1 General Description: 22 and 18 AWG stranded (7x30 and 19x30) tinned copper conductorsm conductors cabled, PVC insulation, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 4 22 7x30 TC - Tinned Copper 2 18 19x30 TC - Tinned Copper Total Number of Conductors: 6 Insulation Insulation Material: Insulation Material Wall Thickness (mm) AWG PVC - Polyvinyl Chloride 0.279 22 PVC - Polyvinyl Chloride 0.483 18 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.8128 Overall Cable Overall Cabling Color Code Chart: Color AWG Red 22 Green 22 Brown 22 Blue 22 White 18 Black 18 Overall Nominal Diameter: 5.994 mm Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +80C UL Temperature Rating: 80C (UL AWM Style 2576) Bulk Cable Weight: 58.040 Kg/Km Max. Recommended Pulling Tension: 346.960 N Min. Bend Radius/Minor Axis: 63.500 mm Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8446 Multi-Conductor - Audio, Control, Communication and Instrumentation Cable Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG CEC/C(UL) Specification: CMG AWM Specification: UL Style 2576 (150 V 80C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 FT4 Loading CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 98.43 Nom. Capacitance Cond. to Other Cond. & Ground: Capacitance (pF/m) 177.174 Nom. Conductor DC Resistance: Description DCR @ 20C (Ohm/km) 22 AWG 50.8555 18 AWG 22.3108 Max. Operating Voltage - UL: Voltage Description 150 V RMS UL AWM Style 2576 300 V RMS CMG Max. Recommended Current: Description Current 22 AWG 2.5 Amps per conductor @ 25C 18 AWG 5.6 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 8446 060U1000 305 MT 18.597 KG CHROME Notes Item Desc 4#22 2#18 PVC PVC 8446 060U500 152 MT 9.752 KG CHROME 4#22 2#18 PVC PVC 8446 060100 30 MT 2.132 KG CHROME 8446 0601000 305 MT 19.505 KG CHROME C 4#22 2#18 PVC PVC 8446 060500 152 MT 9.752 KG CHROME C 4#22 2#18 PVC PVC 4#22 2#18 PVC PVC Notes: C = CRATE REEL PUT-UP. Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8446 Multi-Conductor - Audio, Control, Communication and Instrumentation Cable Revision Number: 3 Revision Date: 12-19-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013