For more Information
please call
1-800-Belden1
General Description:
22 and 18 AWG stranded (7x30 and 19x30) tinned copper conductorsm conductors cabled, PVC
insulation, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
422 7x30 TC - Tinned Copper
218 19x30 TC - Tinned Copper
Total Number of Conductors: 6
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm) AWG
PVC - Polyvinyl Chloride 0.279 22
PVC - Polyvinyl Chloride 0.483 18
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.8128
Overall Cable
Overall Cabling Color Code Chart:
Color AWG
Red 22
Green 22
Brown 22
Blue 22
White 18
Black 18
Overall Nominal Diameter: 5.994 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +80°C
UL Temperature Rating: 80°C (UL AWM Style 2576)
Bulk Cable Weight: 58.040 Kg/Km
Max. Recommended Pulling Tension: 346.960 N
Min. Bend Radius/Minor Axis: 63.500 mm
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8446 Multi-Conductor - Audio, Control, Communication and Instrumentation Cable
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMG
CEC/C(UL) Specification: CMG
AWM Specification: UL Style 2576 (150 V 80°C)
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 FT4 Loading
CSA Flame Test: FT4
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
98.43
Nom. Capacitance Cond. to Other Cond. & Ground:
Capacitance (pF/m)
177.174
Nom. Conductor DC Resistance:
Description DCR @ 20°C (Ohm/km)
22 AWG 50.8555
18 AWG 22.3108
Max. Operating Voltage - UL:
Voltage Description
150 V RMS UL AWM Style 2576
300 V RMS CMG
Max. Recommended Current:
Description Current
22 AWG 2.5 Amps per conductor @ 25°C
18 AWG 5.6 Amps per conductor @ 25°C
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
8446 060U1000 305 MT 18.597 KG CHROME 4#22 2#18 PVC PVC
8446 060U500 152 MT 9.752 KG CHROME 4#22 2#18 PVC PVC
8446 060100 30 MT 2.132 KG CHROME 4#22 2#18 PVC PVC
8446 0601000 305 MT 19.505 KG CHROME C 4#22 2#18 PVC PVC
8446 060500 152 MT 9.752 KG CHROME C 4#22 2#18 PVC PVC
Notes:
C = CRATE REEL PUT-UP.
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8446 Multi-Conductor - Audio, Control, Communication and Instrumentation Cable
Revision Number: 3 Revision Date: 12-19-2012
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8446 Multi-Conductor - Audio, Control, Communication and Instrumentation Cable