22
SPECIFICATIONS
Model No. SF-C11 (Note 2) SF-C12 SF-C13 (Note 2)
Item
Connectable light curtains SF4B / SF2B series SF4B series
Light curtains manufactured by Panasonic Industrial Devices SUNX
Applicable standards IEC 61496-1, EN 61496-1, ANSI/UL 61496-1, CAN/CSA 61496-1, JIS B 9704-1
Control category ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Supply voltage / Current consumption
24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (excluding light curtain)
Fuse (rating) Built‑in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Enabling path NO contact × 3 (13‑14, 23‑24, 33‑34) NO contact × 2 (13‑14, 23‑24) NO contact × 3 (13‑14, 23‑24, 33‑34)
Utilization category AC‑15, DC‑13 (IEC 60947‑5‑1)
Rated operation voltage
(Ue) /
Rated operation current (le)
30 V DC / 6 A, 230 V AC / 6 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 10 mA (at 24 V DC) (Note 3)
24 V DC / 1 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 15 mA (at 24 V DC)
30 V DC / 4 A, 230 V AC / 4 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 10 mA (at 24 V DC) (Note3)
Contact resistance 100 mΩ or less (initial value) 50 mΩ or less (initial value) 100 mΩ or less (initial value)
Contact protection fuse rating
6 A (slow blow) 3 A (slow blow) 4 A (slow blow)
Pick‑up delay (Auto reset / Manual reset)
80 ms or less / 90 ms or less 30 ms or less / 30 ms or less 80 ms or less / 90 ms or less
Response time 10 ms or less 14 ms or less 10 ms or less
Auxiliary output
Safety relay contact (NC contact) ×1 (41-42) (Related to enabling path) Safety relay contact (NC contact) × 1 (31-32) (Related to enabling path) Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path)
Rated operation voltage / current
24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 30 V DC / 3 A, Min. applicable load: 15 mA (at 24 V DC) 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
Contact protection fuse rating
2 A (slow blow) 3 A (slow blow) 2 A (slow blow)
Semiconductor auxiliary output
(AUX)
<Minus ground (Setting for PNP)>
PNP open‑collector transistor
<Plus ground (Setting for NPN)>
NPN open‑collector transistor
–
PNP open‑collector transistor
Output operation Related to auxiliary output of light curtain
–
ON when the light curtain is interrupted
Excess voltage category ⅡⅢⅡ
Polarity selection function
(Note 4)
Incorporated (Sliding switch allows selection of plus / minus ground)
Minus ground: Correspond to PNP output light curtain
Plus ground: Correspond to NPN output light curtain
Incorporated (Cable connection allows selection of plus / minus ground)
Minus ground: Correspond to PNP output light
curtain
Plus ground: Correspond to NPN output light curtain
Pollution degree 2
Protection Enclosure: IP40, Terminal: IP20 IP65 Enclosure: IP40, Terminal: IP20
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
Enclosure material ABS Die‑cast aluminum ABS
Weight Net weight: 320 g approx. Net weight: 1 kg approx. Net weight: 200 g approx.
Notes: 1)
Where measurement conditions have not been specied precisely, the
conditions used were an ambient temperature of +20 °C +68 °F.
2) SF-C11 and SF-C13 have acqusred the Korea S-mark.
3) If several SF-C11 or SF-C13 units are being used in a line together, leave
a space of 5 mm 0.197 in or more between each unit. If the units are
touching each other, reduce the rated operating current for safety output
in accordance with the ambient operating temperature as shown in the
graphs at right.
4) Please switch the sliding switch to the PNP side for minus ground and to
the NPN side for plus ground.
5) For details of control unit SF-C1□(SF-C10 series), refer to the website or
general catalog.
Ambient temperature (°C °F)
0
32
1
2
3
4
5
35
95
40
104
45
113
50
122
55
131
Rated operation current (A)
1
2
3
4
5
Ambient temperature (°C °F)
0
32
35
95
40
104
45
113
50
122
55
131
Rated operation current (A)
Dilating when SF-C11 units
are mounted close together
Dilating when SF-C13 units
are mounted close together
Model No. SF-C14EX(-01) (Note 2)
Item
Connectable light curtains SF4B series
Applicable standards IEC 61496-1, EN 61496-1, ANSI/UL 61496-1, CAN/CSA 61496-1, JIS B 9704-1
Control category ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Supply voltage / Current consumption
24 V DC ±10 % Ripple P-P 10 % or less / 0.2 A or less (Excluding light curtain and other external connecting device)
Enabling path (Enabling path 1, 2, 3)
PNP open‑collector transistor 2 outputs × 3 or NPN open‑collector transistor 2 outputs × 3 (selectable using a slider switch)
Operation mode
(Output operation)
Enabling path 1: ON when the light curtain is in light receiving condition, OFF when the light curtain is in light interrupted condition (Note 3)
Enabling path 2: ON when the light curtain is in light receiving condition or the muting function is valid
OFF when the light curtain is in light interrupted condition and the muting function is invalid (Note 3)
Enabling path 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Response time OFF response: 14 ms or less (Enabling path 1 and 2: including the response time of the light curtain)
ON response: 90 ms or less (auto‑reset) / 140 ms or less (manual reset) (Note 4)
Auxiliary outputs
Auxiliary output 1, 2, 3, 4
(Note 5)
PNP open‑collector transistor × 3 or NPN open‑collector transistor × 3 (selectable using a slider switch)
<When PNP output is selected>
• Maximum source current: 60 mA or less
• Applied voltage: same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2 V or less (at 60 mA source current)
<When NPN output is selected>
• Maximum sink current: 60 mA or less
• Applied voltage: same as supply voltage (between the auxiliary output and 0 V)
• Residual voltage: 2 V or less (at 60 mA sink current)
Operation mode
(Output operation)
Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is valid
Auxiliary output 2: ON when the override function is invalid, OFF when the override function is valid
Auxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is error
Auxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition (Note 5)
Muting lamp output Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Protection Enclosure: IP40, Terminal: IP20
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
Material Enclosure: ABS
Connection terminal Detachable spring‑cage terminal
Weight Net weight: 250 g approx.
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) SF-C14EX-01 is Handy‑controller non‑compatible type.
3)
Both enabling path 1 and 2 are OFF when the emergency stop is valid regardless of whether the light curtain is in the light receiving or light interrupted condition.
4) The auto‑reset cannot be used with enabling path 3.
5) The auxiliary output incorporated in the SF4B series is outputed.
6) For details of control unit SF-C14EX(-01), refer to the website or general catalog.
Control units