SS-P Subminiature Basic Switch - SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept One-piece terminal construction to keep out flux. A single leaf movable spring construction. Conforms to North American and European safety Standards. RoHS Compliant Model Number Legend 1 G SS - @ 2 P @ 3 @ 1. Ratings 3 : 125 VAC 3 A 01: 30 VDC 0.1 A 3. Terminals None : Solder terminals T : Quick-connect terminals (#110) D : PCB terminals 2. Actuator None : Pin plunger L : Hinge lever L13 : Simulated roller lever List of Models Terminals Actuator Ratings 3A 0.1A Solder terminals Quick-connect terminals (#110) PCB terminals Pin plunger SS-3GP SS-3GPT SS-3GPD Hinge lever SS-3GLP SS-3GLPT SS-3GLPD Simulated roller lever SS-3GL13P SS-3GL13PT SS-3GL13PD Pin plunger SS-01GP SS-01GPT SS-01GPD Hinge lever SS-01GLP SS-01GLPT SS-01GLPD Simulated roller lever SS-01GL13P SS-01GL13PT SS-01GL13PD Contact Form SPDT COM NO NC Separator (Sold Separately), Terminal Connector (Sold Separately) Refer to "Basic Switch Common Accessories" 1 SS-P Subminiature Basic Switch Contact Specifications Item Model Contact SS-3P models Rivet Crossbar Material Silver Gold alloy 0.5 mm 0.5 mm Minimum applicable load (reference value) * UL (UL1054/CSA C22.2 No.55) SS-01P models Specification Gap (standard value) * Approved Safety Standards 5 VDC 160 mA Model Rated voltage 5 VDC 1 mA - SS-3P models Item 125 VAC 3A 0.1 A 30 VDC 3A 0.1 A Rated voltage Ratings Model SS-01P Resistive load VDE (EN61058-1) Please refer to "Using Micro Loads" in "Precautions" for more information on the minimum applicable load. Rated voltage SS-3P Item SS-3P SS-01P 125 VAC Model 3A 0.1 A 30 VDC 3A 0.1 A Testing conditions: 5E4 (50,000 operations) T55 (0 to 55C) SS-01P models Resistive load 125 VAC 3A 0.1 A 30 VDC 3A 0.1 A Note 1. The above rating values apply under the following test conditions. (1) Ambient temperature: 202C (2) Ambient humidity: 655% (3) Operating frequency: 20 operations/min Note 2. Consult your OMRON sales representative for information on models for other loads. Characteristics Item Model SS-3P models Permissible operating speed Permissible operating frequency Mechanical 300 operations/min Electrical 30 operations/min Insulation resistance Contact resistance (initial value) Dielectric strength *1 Vibration resistance *2 Shock resistance 100 m max. 1,000 VAC 50/60 Hz for 1 min Between current-carrying metal parts and ground 1,500 VAC 50/60 Hz for 1 min Between each terminals and non-current-carrying metal parts 1,500 VAC 50/60 Hz for 1 min Malfunction Durability Malfunction *2 Electrical Degree of protection Degree of protection against electric shock Proof tracking index (PTI) Ambient operating temperature Ambient operating humidity Weight 100 M min. (at 500 VDC with insulation tester) 50 m max. Between terminals of the same polarity Mechanical Durability *3 SS-01P models 0.1 mm to 1 m/s (for pin plunger models) 10 to 55 Hz, 1.5 mm double amplitude 1,000 m/s2 {approx. 100G} max. 300 m/s2 {approx. 30G} max. 1,000,000 operations min. (60 operations/min) 70,000 operations min. (20 operations/min, 125 VAC) 200,000 operations min. (20 operations/min) 100,000 operations min. (20 operations/min, 30 VDC) IEC IP40 Class I 250 -25C to +85C (at ambient humidity of 60% max.) (with no icing or condensation) 85% max. (for +5 to +35C) Approx. 1.6 g (pin plunger models) Note. The data given above are initial values. *1. The values for dielectric strength shown are for models with a Separator (refer to "Micro Switch Common Accessories"). *2. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1 ms max. *3. For testing conditions, consult your OMRON sales representative. 2 SS-P Subminiature Basic Switch Terminals/Appearances (Unit: mm) Solder terminals Quick Connect Terminals (#110) PCB terminals 5.25 1.8 7.3 11 3.30.1 8.55 15.5 3-1.6 dia. holes 3.30.1 3.30.1 7.1 1.85 0.5 3-1.2 3-0.8 8.80.2 3-2.8 6.40.2 0.5 7.60.2 7.60.2 1.3 0.5 16.10.2 - 3.2 2.15 3.9 6.40.2 6.40.2 16.10.1 8.80.1 3-1.35~1.5 dia. Mounting Holes (Unit: mm) 2-2.4 dia. mounting holes or M2.3 screw holes 9.50.1 Dimensions (Unit: mm) and Operating Characteristics The illustrations and dimensions are for models with solder terminals. Refer to "Terminals/Appearances" for details on models with quick connect terminals (#110) or PCB terminals. Pin plunger SS-3GP SS-01GP 7.550.2 PT 3.5 2 A 2.50.07 dia. 2.35+0.075 -0.05 dia +0.075 OP 2.35 -0.05 6.9 7.7 3.30.1 7.3 8.55 15.5 2.15 Operating characteristics Model SS-3GP SS-01GP Operating Force Releasing Force OF RF Max. Min. 1.50 N {153 gf} 0.2 N {20 gf} Pretravel Overtravel Movement Differential PT OT MD Max. Min. Max. 0.6 mm 0.4 mm 0.15 mm Operating Position OP 8.40.3 mm 0.5 3-1.6 dia. holes 6.40.2 5.15 Hinge lever SS-3GLP SS-01GLP 9.50.1 19.80.2 t=0.3 Stainless-steel lever 14.5 3.6 A 2.50.07 dia. 2.35+0.075 -0.05 6.9 7.7 OP FP 3.30.1 7.3 8.55 15.5 2.15 2.35+0.075 -0.05 dia. 0.5 3-1.6 dia. holes Operating characteristics Model SS-3GLP SS-01GLP Operating Force Releasing Force OF RF Max. Min. 0.5 N {51 gf} 0.05 N {5 gf} Overtravel Movement Differential OT MD Min. Max. 1.0 mm 0.8 mm Free Position Operating Position FP OP Max. 13.6 mm 8.80.8 mm 6.40.2 5.15 9.50.1 19.80.2 Simulated roller lever SS-3GL13P t=0.3 Stainless-steel lever SS-01GL13P 15.8 3.6 A Operating characteristics R1.2 2.50.07 dia. 2.35+0.075 -0.05 6.9 FP 3.30.1 7.3 2.15 7.7 OP 8.55 15.5 2.35+0.075 -0.05 dia. 3-1.6 dia. holes Model SS-3GL13P SS-01GL13P Operating Force Releasing Force OF RF Max. Min. 0.5 N {51 gf} 0.05 N {5 gf} Overtravel Movement Differential OT MD Min. Max. 1.0 mm 0.8 mm Free Position Operating Position FP OP Max. 15.5 mm 10.70.8 mm 0.5 6.40.2 5.15 9.50.1 19.80.2 Note 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. Note 2. The operating characteristics are for operation in the A direction ( ). 3 SS-P Subminiature Basic Switch Precautions Please refer to "Common Precautions" for correct use. Cautions Soldering Mounting Use M2.3 mounting screw with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 0.23 to 0.26 N*m {2.3 to 2.7 kgf*cm}. Using Micro Loads Using a model for ordinary loads to open or close the contact of a micro load circuit may result in faulty contact. Use models that operate in the following range. However, even when using micro load models within the following operating range, if inrush current occurs when the contact is opened or closed, it may increase the contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The N-level reference value applies for the minimum applicable load. This value indicates the malfunction reference level for the reliability level of 60% (60). (JIS C5003) The equation, 60=0.5x10-6/operation indicates that the 1 estimated malfunction rate is less than 2,000,000 operations with a reliability level of 60%. Voltage (V) - * Connecting to Solder Terminals Complete the soldering at the iron tip temperature of 350 to 400C within 5 seconds, and do not apply any external force for 1 minute after soldering. Soldering at an excessively high temperature or soldering for more than 5 seconds may deteriorate the characteristics of the Switch. * Connecting to PCB terminals When using automatic soldering baths, we recommend soldering at 2605C within 5 seconds. Make sure that the liquid surface of the solder does not flow over the edge of the board. When soldering terminals manually, complete the soldering at the iron tip temperature between 350 to 400C within 3 seconds, and do not apply any external force for 1 minute after soldering. When applying solder, keep the solder away from the case of the Switch and do not allow solder or flux to flow into the case. Correct Use 30 0.16 mA 26 mA 100 mA 24 Operating range for micro-load model SS-01P Operating range for general-load model SS-3P 12 5 1 mA 100 mA 160 mA 0 0.1 1 10 100 1,000 Current (mA) 4 SS-P Subminiature Basic Switch * Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. * Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No.B108-E1-03 0812(0207)(O) 5