1
☎ USA (847) 827-7600 - www.e-t-a.com - ☎ CANADA (905) 764-9510Issue D 27
Voltage rating AC 240 V; DC 48 V (UL: AC 250 V)
Current ratings 0.05...10 A
Auxiliary circuit 0.5 A, AC 240 V, DC 28 V
Typical life 0.05...5 A: 3,000 operations at 2 x IN
6 ...8 A: 500 operations at 2 x IN
10 A 50 operations at 2 x IN
with -H: 0.05...8 A 2,000 operations at 1 x IN
10 A 200 operations at 1 x IN
Ambient temperature -20...+60 °C (-4...+140 °F) T 60
Insulation co-ordination Rated impulse Pollution
(IEC 60664 and 60664 A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength Test voltage
(IEC 60664 and 60664A)
operating area AC 3,000 V
Insulation resistance >100 MΩ (DC 500 V)
Interrupting capacity Icn 0.05 ... 2 A 6 x IN
2.5 ...10 A 5 x IN
Interrupting capacity INUN
(UL 1077) 0.05...10 A AC 250 V 2000 A
0.05...10 A DC 48 V 200 A
Degree of protection operating area IP 40
(IEC 60529/DIN 40050) terminal area IP 00
Vibration 10 g (57-500 Hz),±0.76 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock 25 g ( 11 ms) to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH, to IEC 60068-2-3, test Ca
Mass approx. 10 g
Thermal Over current Cir cuit Breakers 104/105/106-...
Description
Miniaturised single pole thermal circuit breaker with push-to-reset
tease free, trip-free, snap action mechanism (R-type TO CBE to EN
60934). Available in versions for PCB or panel mounting, snap-in or
threadneck, or as an integral type. Manual release facility optional for
type 105.
Approved to CBE standard EN 60934 (IEC 60934). For higher current
ratings see type 1140.
Technical data
Authority Voltage ratings Current ratings
VDE (EN 60934), SEV AC 240 V 0,05...8 A
DC 48 V 0.05...10 A
Demko AC 250 V, DC 28 V 0.05...10 A
CSA, UL AC 250 V, DC 48 V 0.05...10 A
Semko AC 250 V, DC 48 V 0.1...10 A
Kema (EN 60934) AC 240 V 0,05...8 A
DC 48 V 0.05...10 A
Circuit breakers with -Si51 not approved
Approvals
104-... 105-... 106-...
Typical applications
Motors, transformers, solenoids, printed circuit boards, hand-held
machines and appliances, marine applications, caravans.
Ordering information
Current Internal Current Internal
rating (A) resistance (Ω) rating (A) resistance (Ω)
0.05 285 1.8 0.28
0.08 134 2 0.25
0.1 81 2.5 0.18
0.2 22 3 0.11
0.3 8.7 3.5 0.076
0.4 5.5 4 0.067
0.5 3.3 4.5 0.051
0.6 2.45 5 ≤ 0.05
0.7 1.6 6 ≤ 0.05
0.8 1.45 7 ≤ 0.05
1 0.9 8 ≤ 0.05
1.2 0.6 10 ≤ 0.05
1.5 0.4
Standard current ratings and typical inter nal resistance values
Type No.
104 PCB mounting type (-PR), or integral type (-P30/P10)
105 snap-in panel mounting
106 threadneck panel mounting with hex and knurled nut *
(international version)
106-M1 as 106 but for standard fuseholder cut-out * (double D)
hex nut and plastic knurled nut Y307 117 02
106-M2 threadneck panel mounting 3/8-27UNS with collar, hex nut and
knurled nut* (US version)
with plastic knurled nut + PTRP Y307 117 02
106-M3 as 106-M2 but for standard fuseholder cut-out (double D)
Terminal design
P10 blade terminals A6.3-0.8 (QC .250)
P30 blade terminals A2.8-0.8 (QC .110)
PR solder terminal pins for PCB mounting (type 104 only)
PR2 PCB mounting (vertical), type 104 only up to 6 A
PR3 PCB mounting (vertical), type 104 only
Shunt terminal (optional)
A3 same as main terminals (up to IN 6 A/3 A max. load)
Manual release facility
H type 105 only
Auxiliary contacts (optional)
Si51 type 104 only
Current ratings
0.05...10 A
106-M2 - P30 - - - 5 A = ordering example
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
* mounting hardware bulk shipped