NEW GENERATION
®CABLES 20.8
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Unshielded Multi-conductor
CM FT1 Rated
Product Description
Bare copper conductors, polypropylene insulation,
PVC jacket. Available in Beige, Brown, Orange,
Yellow, Green, Blue, Purple, Gray or White jacket
colors (except as noted in footnote). Conductors
may not be cabled. Sequential footage marking
every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation Polypropylene
Insulation Thickness .006(.152mm)
Jacket PVC
Approvals
NEC CM
CEC CM FT1
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Single Line Telephone
Station Wire (5582UG)
Solid Conductor
Stranded Conductor
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Residential, Light Commercial and Institutional Applications
Unshielded
Part
No.
Unshielded Multi-conductor (NEC CM and CEC CM FT1)
22 AWG
5500UG* 2 7 C-500 C-152 3.5 1.6 .015 .38 .114 2.90
U-500 U-152 5.0 2.3
C-1000 C-305 7.0 3.2
U-1000 U-305 9.0 4.1
5582UG** 4 solid C-500 C-152 6.0 2.7 .015 .38 .122 3.10
C-1000 C-305 12.0 5.4
U-1000 U-305 13.0 6.0
5502UG 4 7 C-500 C-152 6.5 3.0 .015 .38 .131 3.33
U-500 U-152 7.5 3.4
C-1000 C-305 13.0 6.0
U-1000 U-305 14.0 6.4
5522UG4 solid C-500 C-152 6.0 2.7 .015 .38 .122 3.10
u
C-1000 C-305 12.0 5.4
5520UG 2 solid C-500 C-152 3.5 1.6 .015 .38 .106 2.69
u
C-1000 C-305 7.0 3.2
18 AWG
5300UG†† 2 7 C-500 C-152 7.5 3.4 .015 .38 .148 3.76
U-500 U-152 8.5 3.9
U-1000 U-305 16.0 7.3
* U-1000 available in Brown, Gray or Natural only.
** 5582UG available in Brown, Gray, White or Beige only.
5522UG available in White only.
†† 5300UG available in Gray, Black or Natural only.
5502UG U-500 ft. put-up available in Gray or White only.
5520UG C-500 ft. put-up available in Gray or White only.
Color Code Chart
(5500UG, 5502UG, 5520UG, 5522UG, 5300UG)
Cond. No. Color
1Black
2Red
3White
4Green
Except 5582UG which is Black, Red, Yellow, Green
for use as station wire.
Color Code Chart
(5582UG)
Cond. No. Color
1Black
2Red
3Yellow
4Green
NEW GENERATION
®CABLES 20.9
20 New Generation®Cables
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Unshielded
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Part
No.
Unshielded Multi-conductor (NEC CMR and CEC CMG FT4)
22 AWG
5520UE 2 solid C-500 C-152 4.0 1.8 .015 .38 .122 3.10
U-500 U-152 5.5 2.5
C-1000 C-305 8.0 3.6
U-1000 U-305 9.0 4.1
1000 305 9.0 4.1
5500UE 2 7 C-500 C-152 4.0 1.8 .015 .38 .128 3.25
U-500 U-152 5.5 2.5
500 152 5.5 2.5
C-1000 C-305 8.0 3.6
U-1000 U-305 10.0 4.5
1000 305 9.0 4.1
5501UE 3 7 U-1000 U-305 13.0 5.9 .015 .38 .135 3.43
1000 305 13.0 5.9
5522UE 4 solid U-1000 U-305 16.0 7.3 .015 .38 .141 3.58
1000 305 16.0 7.3
5582UE* 4 solid C-500 C-152 7.0 3.2 .015 .38 .141 3.58
U-500 U-152 6.5 3.0
U-1000 U-305 12.0 5.5
1000 305 12.0 5.5
5502UE** 4 7 C-500 C-152 7.5 3.4 .015 .38 .148 3.76
U-500 U-152 9.0 4.1
U-1000 U-305 16.0 7.3
1000 305 16.0 7.3
5503UE 5 7 U-1000 U-305 20.0 9.1 .015 .38 .162 4.11
1000 305 20.0 9.1
5524UE 6 solid C-500 C-152 10.5 4.8 .015 .38 .168 4.27
1000 305 22.0 10.0
5504UE** 6 7 C-500 C-152 12.5 5.7 .015 .38 .177 4.50
U-500 U-152 14.0 6.4
500 152 13.5 6.1
U-1000 U-305 27.0 12.3
1000 305 27.0 12.3
5526UE 8 solid 1000 305 28.0 12.7 .015 .38 .182 4.62
5506UE 8 7 U-1000 U-305 29.0 13.2 .015 .38 .192 4.88
1000 305 30.0 13.6
5508UE 10 7 U-1000 U-305 36.0 16.3 .015 .38 .226 5.74
1000 305 41.0 18.6
5529UE 12 solid U-1000 U-305 40.0 18.1 .015 .38 .221 5.61
1000 305 42.0 19.1
5509UE 12 7 U-500 U-152 21.5 9.8 .015 .38 .233 5.92
U-1000 U-305 42.0 19.1
1000 305 47.0 21.4
20 AWG
5400UE 2 7 C-500 C-152 6.0 2.7 .015 .38 .142 3.61
U-1000 U-305 13.0 5.9
1000 305 13.0 5.9
5401UE 3 7 500 152 9.0 4.1 .015 .38 .150 3.81
U-1000 U-305 18.0 8.2
1000 305 18.0 8.2
5402UE 4 7 C-500 C-152 10.5 4.8 .015 .38 .165 4.19
U-1000 U-305 23.0 10.5
1000 305 23.0 10.5
5403UE 5 7 U-1000 U-305 27.0 12.2 .015 .38 .181 4.60
1000 305 28.0 12.7
5405UE 7 7 500 152 19.0 8.6 .015 .38 .198 5.03
1000 305 40.0 18.2
5406UE 8 7 U-1000 U-305 41.0 18.6 .015 .38 .215 5.46
1000 305 43.0 19.5
5407UE 9 7 1000 305 48.0 21.8 .015 .38 .233 5.92
5408UE 10 7 1000 305 53.0 24.1 .015 .38 .254 6.45
5409UE 12 7 1000 305 62.0 28.1 .015 .38 .262 6.65
540BUE 20 7 1000 305 110.0 49.9 .025 .64 .347 8.81
* 5582UE also available in Beige, Brown or White.
** 5502UE and 5504UE also available in White.
Color Code Chart ††
Cond. No. Color
1Black
2Red
3White
4Green
5Brown
6Blue
7Orange
8Yellow
9Purple
10 Gray
Cond. No. Color
11 Pink
12 Tan
13 White/Black
14 White/Red
15 White/Green
16 White/Orange
17 White/Blue
18 White/Brown
19 White/Yellow
20 White/Purple
††Except 5582UE which is Black, Red, Yellow, Green for use as station wire.
Unshielded Multi-conductor
CMR/CMG FT4 Rated
Product Description
Bare copper conductors, PVC insulation, Gray PVC
jacket with rip cord. Sequential footage marking
every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Jacket PVC
Approvals
NEC CMR
CEC CMG FT4
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Single Line Telephone
Solid Conductor
Stranded Conductor
NEW GENERATION
®CABLES 20.10
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Unshielded
Part
No.
Unshielded Multi-conductor (NEC CMR and CEC CMG FT4)
18 AWG
5320UE 2 solid C-500 C-152 7.5 3.4 .015 .38 .151 3.84
U-1000 U-305 17.0 7.7
5300UE* 2 7 C-500 C-152 8.5 3.9 .015 .38 .161 4.09
U-500 U-152 9.5 4.3
500 152 9.5 4.3
U-1000 U-305 17.0 7.7
1000 305 18.0 8.2
5321UE 3 solid U-1000 U-305 23.0 10.4 .015 .38 .160 4.06
1000 305 23.0 10.4
5301UE 3 7 500 152 12.5 5.7 .015 .38 .171 4.34
U-1000 U-305 25.0 11.3
1000 305 25.0 11.3
5322UE 4 solid 1000 305 30.0 13.6 .015 .38 .176 4.47
5302UE 4 7 C-250 C-76.2 7.5 3.4 .015 .38 .188 4.78
U-500 U-152 16.5 7.5
500 152 16.0 7.3
U-1000 U-305 32.0 14.5
1000 305 32.0 14.5
5303UE 5 7 500 152 20.5 9.3 .015 .38 .207 5.26
U-1000 U-305 39.0 17.7
1000 305 39.0 17.7
5304UE 6 7 500 152 26.0 11.8 .015 .38 .226 5.74
U-1000 U-305 51.0 23.2
1000 305 52.0 23.6
5305UE 7 7 U-1000 U-305 51.0 23.2 .015 .38 .226 5.74
1000 305 52.0 23.6
5306UE 8 7 500 152 30.0 13.6 .015 .38 .248 6.30
1000 305 59.0 26.8
5307UE 9 7 1000 305 66.0 30.0 .015 .38 .269 6.83
5308UE 10 7 500 152 38.5 17.5 .015 .38 .294 7.47
1000 305 74.0 33.6
5309UE 12 7 500 152 47.5 21.6 .020 .51 .314 7.98
1000 305 90.0 40.9
530BUE 20 7 1000 305 152.0 69.0 .025 .64 .400 10.16
16 AWG
5200UE 2 19 C-500 C-152 11.5 5.2 .015 .38 .184 4.67
U-500 U-152 13.0 5.9
500 152 12.5 5.7
U-1000 U-305 24.0 10.9
1000 305 25.0 11.4
5201UE 3 19 U-500 U-152 18.5 8.4 .015 .38 .196 4.98
500 152 18.0 8.2
U-1000 U-305 35.0 15.9
1000 305 38.0 17.3
5202UE 4 19 U-500 U-152 23.5 10.7 .015 .38 .216 5.49
500 152 23.0 10.4
U-1000 U-305 45.0 20.4
1000 305 47.0 21.3
5205UE 7 19 1000 305 77.0 35.0 .015 .38 .261 6.63
*5300UE also available in White or Black.
Unshielded Multi-conductor
(cont’d.)
CMR/CMG FT4 Rated
Product Description
Bare copper conductors, PVC insulation, Gray PVC
jacket with rip cord. Sequential footage marking
every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Jacket PVC
Approvals
NEC CMR
CEC CMG FT4
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Addressable Fire Systems
Data Circuits
Monitor/Detection
Control Circuits
Initiating Circuits
Notification Circuits
Solid Conductor
Stranded Conductor
Color Code Chart
Cond. No. Color
1Black
2Red
3White
4Green
5Brown
6Blue
7Orange
8Yellow
9Purple
10 Gray
Cond. No. Color
11 Pink
12 Tan
13 White/Black
14 White/Red
15 White/Green
16 White/Orange
17 White/Blue
18 White/Brown
19 White/Yellow
20 White/Purple
NEW GENERATION
®CABLES 20.11
20 New Generation®Cables
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Unshielded
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Part
No.
Unshielded Multi-conductor (NEC CMR FPLR CL3R)
14 AWG
5100UE* 2 19 500 152 20.0 9.1 .015 .38 .234 5.94
U-1000 U-305 38.0 17.2
1000 305 40.0 18.2
5101UE 3 19 1000 305 56.0 25.5 .015 .38 .249 6.32
5102UE 4 19 500 152 38.5 17.5 .015 .38 .276 7.01
1000 305 71.0 33.2
12 AWG
5000UE* 2 19 500 152 29.0 13.2 .015 .38 .268 6.81
1000 305 57.0 25.9
5001UE 3 19 1000 305 82.0 37.3 .015 .38 .286 7.26
*5100UE and 5000UE also available in Red for Fire Alarm (FPLR).
Color Code Chart
Cond. No. Color
1Black
2White
3Red
4Green
Unshielded Multi-conductor
CMR/CL3R Rated
Product Description
Bare copper conductors, PVC insulation, Gray PVC
jacket with rip cord. Sequential footage marking
every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness .014(.356mm)
Jacket PVC
Approvals
NEC CMR FPLR& CL3R
NEC Articles 725 & 760
Voltage Rating 300V
Temperature Rating 75°C
CMR FPLR dual rating for 5000UE, 5100UE, 5000FE and 5100FE only.
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Single Line Telephone
Fire Alarm Systems (Red Only) Dual Rated**
NEW GENERATION
®CABLES 20.12
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Shielded Multi-conductor
CMR/CMG FT4 Rated
Product Description
Bare copper conductors, PVC insulation, cabled,
Beldfoil®shield tape (foil side out) with drain wire,
Gray PVC jacket with rip cord. Sequential footage
marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Shield Beldfoil
Jacket PVC
Approvals
NEC CMR
CEC CMG FT4
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Solid Conductor
Stranded Conductor
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded
Part
No.
Shielded Multi-conductor (NEC CMR and CEC CMG FT4)
24 AWG
5600FE 2 7 U-1000 U-305 11.0 5.0 .015 .38 .120 3.05
1000 305 10.0 4.5
22 AWG
5520FE 2 solid C-500 C-152 6.5 3.0 .015 .38 .125 3.18
C-1000 C-305 13.0 5.9
U-1000 U-305 14.0 6.4
1000 305 14.0 6.4
5500FE 2 7 C-500 C-152 5.5 2.5 .015 .38 .130 3.30
U-500 U-152 6.5 3.0
500 152 6.5 3.0
U-1000 U-305 12.0 5.4
1000 305 12.0 5.4
5521FE 3 solid U-1000 U-305 12.0 5.4 .015 .38 .132 3.35
1000 305 12.0 5.4
5501FE 3 7 C-500 C-152 7.0 3.2 .015 .38 .138 3.51
U-500 U-152 8.0 3.6
500 152 7.5 3.4
U-1000 U-305 15.0 6.8
1000 305 15.0 6.8
5502FE 4 7 C-500 C-152 8.5 3.9 .015 .38 .152 3.86
U-500 U-152 9.5 4.3
500 152 9.5 4.3
U-1000 U-305 18.0 8.2
1000 305 18.0 8.2
5503FE 5 7 1000 305 22.0 10.0 .015 .38 .165 4.19
5504FE 6 7 C-500 C-152 13.5 6.1 .015 .38 .179 4.55
U-500 U-152 15.0 6.8
U-1000 U-305 29.0 13.2
1000 305 29.0 13.2
5506FE 8 7 U-500 U-152 16.5 7.5 .015 .38 .196 4.98
U-1000 U-305 32.0 14.5
1000 305 32.0 14.5
5508FE 10 7 U-500 U-152 19.5 8.9 .015 .38 .230 5.84
U-1000 U-305 38.0 17.2
1000 305 44.0 20.0
20 AWG
5400FE 2 7 C-500 C-152 8.0 3.6 .015 .38 .145 3.68
U-500 U-152 9.0 4.1
500 152 8.5 3.9
U-1000 U-305 17.0 7.2
1000 305 17.0 7.2
5401FE 3 7 U-500 U-152 11.0 5.0 .015 .38 .153 3.89
500 152 10.5 4.8
U-1000 U-305 21.0 9.5
1000 305 21.0 9.5
5402FE 4 7 C-500 C-152 12.0 5.4 .015 .38 .168 4.27
U-500 U-152 12.5 5.7
500 152 13.0 5.9
U-1000 U-305 25.0 11.3
1000 305 26.0 11.8
5403FE 5 7 U-1000 U-305 30.0 13.6 .015 .38 .184 4.67
1000 305 30.0 13.6
5405FE 7 7 U-1000 U-305 39.0 17.7 .015 .38 .201 5.11
1000 305 40.0 18.2
5407FE 9 7 1000 305 51.0 23.2 .015 .38 .236 5.99
Shorting Fold
Color Code Chart
Cond. No. Color
1Black
2Red
3White
4Green
5Brown
6Blue
7Orange
8Yellow
9Purple
10 Gray
Shorting Fold
NEW GENERATION
®CABLES 20.13
20 New Generation®Cables
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Part
No.
Shielded Multi-conductor (NEC CMR and CEC CMG FT4)
18 AWG
5320FE 2 solid C-500 C-152 10.0 4.6 .015 .38 .155 3.94
U-1000 U-305 21.0 9.5
1000 305 21.0 9.5
5300FE 2 7 C-500 C-152 11.0 5.0 .015 .38 .165 4.19
U-500 U-152 12.0 5.5
500 152 12.0 5.5
U-1000 U-305 23.0 10.4
1000 305 23.0 10.4
5301FE 3 7 U-500 U-152 15.5 7.0 .015 .38 .175 4.45
500 152 15.0 6.8
U-1000 U-305 30.0 13.6
1000 305 30.0 13.6
5302FE 4 7 C-250 C-76 8.8 4.0 .015 .38 .192 4.88
U-500 U-152 19.0 8.6
500 152 20.5 9.3
U-1000 U-305 36.0 16.3
1000 305 37.0 16.8
5303FE 5 7 U-500 U-152 22.5 10.2 .015 .38 .211 5.36
500 152 22.5 10.2
U-1000 U-305 43.0 19.5
1000 305 45.0 20.5
5304FE 6 7 U-500 U-152 28.5 12.9 .015 .38 .230 5.84
500 152 26.0 11.8
1000 305 57.0 25.9
5305FE 7 7 1000 305 57.0 25.9 .015 .38 .230 5.84
5306FE* 8 7 500 152 32.0 14.5 .015 .38 .270 6.86
1000 305 64.0 29.1
5307FE 9 7 1000 305 71.0 32.3 .015 .38 .272 6.91
16 AWG
5200FE** 2 19 U-500 U-152 16.5 7.5 .015 .38 .188 4.78
500 152 16.5 7.5
U-1000 U-305 31.0 14.1
1000 305 32.0 14.5
5201FE 3 19 500 152 21.5 9.8 .015 .38 .200 5.08
U-1000 U-305 42.0 19.1
1000 305 42.0 19.1
5202FE 4 19 500 152 26.5 12.0 .015 .38 .220 5.59
1000 305 54.0 24.5
Shielded Multi-conductor (NEC CL3R)
14 AWG
5100FE2 19 500 152 28.5 12.9 .015 .38 .238 6.05
U-1000 U-305 49.0 22.2
1000 305 51.0 23.2
5101FE 3 19 1000 305 66.0 30.0 .015 .38 .253 6.43
12 AWG
5000FE2 19 500 152 36.5 16.6 .015 .38 .272 6.91
1000 305 67.0 30.5
* 5306FE also available in Natural.
** 5200FE also available in White.
5100FE and 5000FE available in Red or Gray for Fire Alarm (FPLR).
Shorting Fold
Shorting Fold
Cond. No. Color
1Black
2Red
3White
4Green
5Brown
Cond. No. Color
6Blue
7Orange
8Yellow
9Purple
10 Gray
Color Code Chart (18 to 16 AWG)
(14 to 12 AWG)
Cond. No. Color
1Black
2White
3Red
Shielded Multi-conductor
(cont’d.)
CMR/CMG FT4 Rated or CL3R Rated
Product Description
Bare copper conductors, PVC insulation, cabled,
Beldfoil®shield tape (foil side out) with drain wire,
Gray PVC jacket with rip cord. Sequential footage
marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness
18 to 16 AWG .010(.254mm)
14 to 12 AWG .014(.356mm)
Shield Beldfoil
Jacket PVC
Approvals
NEC (18 to 16 AWG) CMR FPLR
CEC (18 to 16 AWG) CMG FT4
NEC (14 to 12 AWG) CL3R
NEC Articles
18 to 16 AWG 800
14 to 12 AWG 725
Voltage Rating 300V
Temperature Rating 75°C
CMR FPLR dual rating for 5000UE, 5100UE, 5000FE and 5100FE only.
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Fire Alarm Systems (Red Only) Dual Rated
Solid Conductor
Stranded Conductor
NEW GENERATION
®CABLES 20.14
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Water-Blocked for Use in Underground Ducts
Unshielded and Shielded
Part
No.
Water-blocked, Unshielded Multi-conductor (NEC CM and CEC CM FT1)
18 AWG
5300U1 2 7 U-500 U-152 12.0 5.5 .025 .64 .207 5.26
500 152 13.5 6.1
U-1000 U-305 22.0 10.0
1000 305 24.0 10.9
Water-blocked, Shielded Multi-conductor (NEC CM and CEC CM FT1)
22 AWG
5500F1 2 7 U-500 U-152 9.0 4.1 .025 .64 .192 4.88
500 152 9.0 4.1
U-1000 U-305 16.0 7.3
1000 305 17.0 7.7
20 AWG
5400F1 2 7 U-500 U-152 11.5 5.2 .025 .64 .206 5.23
500 152 11.0 5.0
U-1000 U-305 21.0 9.5
1000 305 21.0 9.5
18 AWG
5300F1 2 7 U-500 U-152 15.0 6.8 .025 .64 .222 5.64
500 152 15.0 6.8
U-1000 U-305 29.0 13.2
1000 305 30.0 13.6
Water-blocked,
Unshielded Multi-conductor
CM FT1 Rated
Product Description
Tinned copper conductors, PVC insulation, cabled
with overall water-blocking tape, Gray PVC jacket
with rip cord. Sequential footage marking every
two feet.
Water-blocked,
Shielded Multi-conductor
CM FT1 Rated
Product Description
Tinned copper conductors, PVC insulation, cabled
with overall Beldfoil®shield and drain wire, overall
water-blocking tape, Gray PVC jacket with rip cord.
Sequential footage marking every two feet.
Color Code: Black, Red.
Specifications
Conductor Tinned Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Shield (where applicable) Beldfoil
Jacket PVC
Approvals
NEC CM
CEC CM FT1
NEC Articles 800
Voltage Rating 300V
Temperature Rating 105°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Indoor or Outdoor Use
Unshielded Water-blocked
Shielded and Water-blocked
NEW GENERATION
®CABLES 20.15
20 New Generation®Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Unshielded Twisted Pairs
CMR/CMG FT4 Rated
Product Description
Bare copper conductors, PVC insulation.
Conductors twisted into pairs, multiple pairs
cabled together, Gray PVC jacket with rip cord.
Sequential footage marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Jacket PVC
Approvals
NEC CMR
CEC CMG FT4
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Stranding
No. of
Pairs mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Unshielded
Part
No.
Unshielded Twisted Pairs (NEC CMR and CEC CMG FT4)
22 AWG
5541UE 2 7 U-1000 U-305 18.0 8.2 .015 .38 .206 5.23
1000 305 19.0 8.6
5542UE 3 7 U-500 U-152 13.0 5.9 .015 .38 .220 5.59
U-1000 U-305 24.0 10.9
1000 305 26.0 11.8
5543UE 4 7 U-1000 U-305 31.0 14.1 .015 .38 .243 6.17
1000 305 32.0 14.5
5547UE 9 7 1000 305 70.0 31.8 .020 .51 .334 8.48
18 AWG
5341UE 2 7 U-1000 U-305 34.0 15.4 .015 .38 .266 6.76
1000 305 36.0 16.4
5342UE 3 7 U-1000 U-305 48.0 21.8 .015 .38 .283 7.19
1000 305 50.0 22.7
5343UE 4 7 1000 305 67.0 30.5 .018 .46 .320 8.13
5345UE 6 7 1000 305 96.0 43.6 .018 .46 .362 9.19
5347UE 9 7 1000 305 140.0 63.6 .020 .51 .434 11.02
Color Code Chart
Pair No. Color Combination
1Black & Red
2Black & White
3Black & Green
4Black & Blue
5Black & Yellow
6Black & Brown
7Black & Orange
8Red & White
9Red & Green
NEW GENERATION
®CABLES 20.16
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Overall Shielded Twisted Pairs
CMR/CMG FT4 Rated
Product Description
Bare copper conductors, PVC insulation.
Conductors twisted into pairs, multiple pairs
cabled together, overall Beldfoil®shield (foil
side out) and drain wire, overall Gray PVC
jacket with rip cord. Sequential footage
marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Shield Beldfoil
Jacket PVC
Approvals
NEC CMR
CEC CMG FT4
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Solid Conductor
Stranded Conductor
Stranding
No. of
Pairs mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded
Part
No.
Overall Shielded Twisted Pairs (NEC CMR and CEC CMG FT4)
22 AWG
5561FE 2 solid U-1000 U-305 21.0 9.5 .015 .38 .200 5.08
1000 305 22.0 10.0
5541FE 2 7 U-500 U-152 11.5 5.2 .015 .38 .209 5.31
U-1000 U-305 21.0 9.5
1000 305 23.0 10.4
5562FE 3 solid U-1000 U-305 26.0 11.8 .015 .38 .212 5.38
1000 305 28.0 12.7
5542FE 3 7 U-1000 U-305 27.0 12.3 .015 .38 .223 5.66
1000 305 29.0 13.2
5563FE 4 solid U-1000 U-305 33.0 15.0 .015 .38 .246 6.25
5543FE 4 7 1000 305 34.0 15.4 .015 .38 .246 6.25
5545FE 6 7 U-1000 U-305 46.0 20.9 .015 .38 .278 7.06
1000 305 48.0 21.8
20 AWG
5441FE 2 7 500 152 15.0 6.8 .015 .38 .235 5.97
U-1000 U-305 29.0 13.2
1000 305 30.0 13.2
5442FE 3 7 U-1000 U-305 38.0 17.2 .015 .38 .252 6.40
1000 305 38.0 17.2
5445FE 6 7 1000 305 72.0 32.7 .020 .51 .323 8.20
18 AWG
5341FE 2 7 500 152 21.0 9.5 .015 .38 .270 6.86
U-1000 U-305 40.0 18.1
1000 305 42.0 19.1
5342FE 3 7 1000 305 52.0 23.6 .015 .38 .275 6.99
5343FE 4 7 1000 305 70.0 31.8 .015 .38 .318 8.08
5345FE 6 7 500 152 52.5 23.9 .020 .51 .373 9.47
1000 305 103.0 46.8
Shorting Fold
Color Code Chart
Pair No. Color Combination
1Black & Red
2Black & White
3Black & Green
Pair No. Color Combination
4Black & Blue
5Black & Yellow
6Black & Brown
Shorting Fold
NEW GENERATION
®CABLES 20.17
20 New Generation®Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Individually Shielded Twisted Pairs
CMR/CMG FT4 Rated
Product Description
Bare copper conductors, PVC insulation.
Conductors twisted into pairs and individually
shielded with Beldfoil®tape (aluminum side
facing in) and a drain wire, multiple pairs
cabled together, Gray PVC jacket with rip cord.
Sequential footage marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Shield Beldfoil
Jacket PVC
Approvals
NEC CMR
CEC CMG FT4
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Stranding
No. of
Pairs mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded
Part
No.
Individually Shielded Twisted Pairs (NEC CMR and CEC CMG FT4)
22 AWG
5543PE 4 7 1000 305 55.0 25.0 .033 .84 .303 7.70
Color Code Chart
Pair No. Color Combination
1Black/Red & Red
2Black/White & White
3Black/Green & Green
4Black/Blue & Blue
NEW GENERATION
®CABLES 20.18
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Shielded
Twisted Pair plus Conductor(s)
CMR/CMG FT4 Rated
Product Description
Bare copper conductors, PVC insulation, Black/Red
pair shielded with Beldfoil®tape (aluminum side
facing in) and tinned copper drain wire, cabled
with additional insulated conductor(s) as indicated,
Gray PVC jacket with rip cord. Sequential footage
marking every two feet.
Color Code: Black & Red (shielded pair),
White, Green. (5542GE Black & Red, Black & White,
Black & Green pairs).
Specifications
Conductor Bare Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Shield Beldfoil
Jacket PVC
Approvals
NEC CMR
CEC CMG FT4
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Stranding
No. of
Pairs +
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded
Part
No.
STP plus Conductor(s) (NEC CMR and CEC CMG FT4)
22 AWG
5501GE 1 STP 7 U-1000 U-305 16.0 7.3 .015 .38 .171 4.34
+1/C
5502GE 1 STP 7 U-500 U-152 10.0 4.5 .015 .38 .186 4.72
+2/C U-1000 U-305 19.0 8.6
1000 305 19.0 8.6
5542GE 1 STP 7 U-1000 U-305 26.0 11.8 .015 .38 .220 5.59
+2TP
20 AWG
5401GE 1 STP 7 1000 305 23.0 10.4 .015 .38 .196 4.98
+1/C
5402GE 1 STP 7 U-1000 U-305 26.0 11.8 .015 .38 .200 5.08
+2/C
18 AW G
5302GE 1 STP 7 U-1000 U-305 38.0 17.2 .015 .38 .225 5.72
+2/C
STP = Shielded Twisted Pair(s) • /C = Conductor(s)
Shorting Fold
NEW GENERATION
®CABLES 20.19
20 New Generation®Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Water-blocked, Shielded
Twisted Pair plus Conductor(s)
CM FT1 Rated
Product Description
Tinned copper conductors, PVC insulation, Black/
Red conductors twisted into a pair and shielded with
Beldfoil®tape (aluminum side facing in) and drain
wire, cabled with additional insulated conductor(s)
as indicated, water-blocking tape overall, Gray PVC
jacket with rip cord. Sequential footage marking
every two feet.
Color Code: Black & Red (shielded pair);
White, Green, Brown, Blue.
Specifications
Conductor Tinned Copper
Insulation PVC
Insulation Thickness .010(.254mm)
Shield
Twisted Pair Beldfoil
Overall Water-blocking Tape
Jacket PVC
Approvals
NEC CM
CEC CM FT1
NEC Articles 800
Voltage Rating 300V
Temperature Rating 105°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Indoor or Outdoor Use
Solid Conductor
Stranded Conductor
Stranding
No. of
Pairs +
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Water-Blocked for Use in Underground Ducts
Part
No.
Water-blocked, STP plus Conductor(s) (NEC CM and CEC CM FT1)
22 AWG
5521G1 1 STP solid U-500 U-152 12.0 5.4 .025 .64 .212 5.38
+1/C 500 152 13.0 5.9
U-1000 U-305 22.0 10.0
1000 305 22.0 10.0
5501G1 1 STP 7 U-500 U-152 12.0 5.4 .025 .64 .222 5.64
+1/C 500 152 12.0 5.4
U-1000 U-305 23.0 10.4
1000 305 25.0 11.4
5522G1 1 STP solid U-500 U-152 13.0 6.0 .025 .64 .224 5.69
+2/C 500 152 15.0 6.8
U-1000 U-305 25.0 11.3
1000 305 27.0 12.3
5502G1 1 STP 7 U-500 U-152 14.0 6.4 .025 .64 .240 6.10
+2/C 500 152 14.0 6.4
U-1000 U-305 27.0 12.3
1000 305 29.0 13.2
5504G1 1 STP 7 U-500 U-152 18.0 8.2 .025 .64 .240 6.10
+4/C 500 152 18.5 8.4
U-1000 U-305 35.0 15.9
1000 305 37.0 16.8
STP = Shielded Twisted Pair(s) • /C = Conductor(s)
Shorting Fold
Shorting Fold
NEW GENERATION
®CABLES 20.20
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Unshielded Multi-conductor
CMP FT6 Rated
Product Description
Bare copper conductors, Flamarrest®insulation,
conductors cabled, Natural Flamarrest jacket,
rip cord. Sequential footage marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation Flamarrest
Insulation Thickness .009(.229mm)
Jacket Flamarrest
Approvals
NEC CMP
CEC CMP FT6
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Solid Conductor
Stranded Conductor
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Unshielded, Plenum-Rated
Part
No.
Unshielded Multi-conductor (NEC CMP and CEC CMP FT6)
22 AWG
6520UE 2 solid U-1000 U-305 10.0 4.5 .015 .38 .118 3.00
1000 305 9.0 4.1
6500UE 2 7 C-500 C-152 4.5 2.0 .015 .38 .124 3.15
C-1000 C-305 9.0 4.1
U-1000 U-305 10.0 4.5
1000 305 10.0 4.5
6521UE 3 solid 1000 305 13.0 5.9 .015 .38 .125 3.18
6501UE 3 7 U-1000 U-305 14.0 6.4 .015 .38 .131 3.33
1000 305 13.0 5.9
6522UE 4 solid U-500 U-152 8.5 3.9 .015 .38 .136 3.45
U-1000 U-305 17.0 7.7
1000 305 16.0 7.3
6502UE 4 7 C-500 C-152 8.0 3.6 .015 .38 .143 3.63
U-500 U-152 9.0 4.1
500 152 8.5 3.9
U-1000 U-305 17.0 7.7
1000 305 17.0 7.7
6524UE 6 solid C-500 C-152 10.5 4.8 .015 .38 .162 4.11
U-1000 U-305 23.0 10.5
6504UE 6 7 C-500 C-152 11.0 5.0 .015 .38 .171 4.34
500 152 12.0 5.5
U-1000 U-305 24.0 10.9
1000 305 24.0 10.9
6506UE 8 7 U-500 U-152 15.5 7.0 .015 .38 .186 4.72
U-1000 U-305 30.0 13.6
1000 305 31.0 14.1
6508UE 10 7 U-1000 U-305 37.0 16.8 .015 .38 .218 5.54
1000 305 43.0 19.5
6509UE 12 7 U-500 U-152 22.5 10.2 .015 .38 .225 5.72
U-1000 U-305 43.0 19.5
1000 305 45.0 20.4
20 AWG
6400UE 2 7 C-500 C-152 6.0 2.7 .015 .38 .138 3.51
500 152 7.0 3.2
U-1000 U-305 14.0 6.4
1000 305 14.0 6.4
6401UE 3 7 U-1000 U-305 19.0 8.6 .015 .38 .146 3.71
1000 305 18.0 8.2
5000 1524 90.0 40.9
6402UE 4 7 U-1000 U-305 24.0 10.9 .015 .38 .160 4.06
1000 305 24.0 10.9
6403UE 5 7 U-1000 U-305 28.0 12.7 .015 .38 .176 4.47
1000 305 28.0 12.7
6406UE 8 7 1000 305 44.0 20.0 .015 .38 .209 5.31
Color Code Chart
Cond. No. Color
1Black
2Red
3White
4Green
5Brown
6Blue
Cond. No. Color
7Orange
8Yellow
9Purple
10 Gray
11 Pink
12 Tan
NEW GENERATION
®CABLES 20.21
20 New Generation®Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Unshielded, Plenum-Rated
Part
No.
Unshielded Multi-conductor (NEC CMP and CEC CMP FT6)
18 AWG
6320UE 2 solid U-1000 U-305 17.0 7.7 .015 .38 .147 3.73
6300UE* 2 7 C-500 C-152 8.0 3.6 .015 .38 .157 3.99
U-500 U-152 9.5 4.3
500 152 9.0 4.1
U-1000 U-305 18.0 8.2
1000 305 18.0 8.2
5000 1520 90.0 40.8
6321UE 3 solid U-1000 U-305 24.0 10.9 .015 .38 .156 3.96
1000 305 24.0 10.9
6301UE 3 7 500 152 12.5 5.7 .015 .38 .168 4.27
U-1000 U-305 25.0 11.4
1000 305 25.0 11.4
6322UE 4 solid U-1000 U-305 30.0 13.6 .015 .38 .171 4.34
6302UE 4 7 C-250 C-76 8.5 3.9 .015 .38 .186 4.72
C-500 C-152 17.0 7.7
U-500 U-152 18.5 8.4
500 152 18.5 8.4
U-1000 U-305 36.0 16.4
1000 305 39.0 17.7
5000 1524 180.0 81.7
6303UE 5 7 U-1000 U-305 39.0 17.7 .015 .38 .203 5.16
1000 305 40.0 18.1
6304UE 6 7 U-500 U-152 23.5 10.7 .015 .38 .222 5.64
500 152 23.0 10.4
1000 305 51.0 23.2
6306UE 8 7 500 152 30.5 13.9 .015 .38 .242 6.15
1000 305 65.0 29.5
6307UE 9 7 1000 305 68.0 30.9 .015 .38 .262 6.65
6308UE 10 7 1000 305 75.0 34.1 .015 .38 .286 7.26
6309UE 12 7 1000 305 84.0 38.2 .015 .38 .296 7.52
16 AWG
6200UE 2 19 500 152 13.0 5.9 .015 .38 .180 4.57
U-1000 U-305 25.0 11.3
1000 305 26.0 11.8
6201UE 3 19 500 152 18.0 8.2 .015 .38 .191 4.85
U-1000 U-305 36.0 16.4
1000 305 37.0 16.8
6202UE 4 19 500 152 24.0 10.9 .015 .38 .211 5.36
U-1000 U-305 46.0 20.9
1000 305 52.0 23.6
*6300UE also available in Gray and Black.
Unshielded Multi-conductor
(cont’d.)
CMP FT6 Rated
Product Description
Bare copper conductors, Flamarrest®insulation,
conductors cabled, Natural Flamarrest jacket,
rip cord. Sequential footage marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation Flamarrest
Insulation Thickness .009(.229mm)
Jacket Flamarrest
Approvals
NEC CMP
CEC CMP FT6
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Solid Conductor
Stranded Conductor
Color Code Chart
Cond. No. Color
1Black
2Red
3White
4Green
5Brown
6Blue
Cond. No. Color
7Orange
8Yellow
9Purple
10 Gray
11 Pink
12 Tan
NEW GENERATION
®CABLES 20.22
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Unshielded Multi-conductor
CL2P Rated
Product Description
Bare copper conductors, Flamarrest®insulation,
conductors cabled, Natural Flamarrest jacket,
rip cord. Sequential footage marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation Flamarrest
Insulation Thickness .011(.279mm)
Jacket Flamarrest
Approvals
NEC CL2P
NEC Articles 725
Voltage Rating 150V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Unshielded, Plenum-Rated
Part
No.
Unshielded Multi-conductor (NEC CL2P)
14 AWG
6100UE 2 19 500 152 19.5 8.8 .015 .38 .222 5.64
U-1000 U-305 38.0 17.2
1000 305 38.0 17.2
5000 1524 195.0 88.5
6101UE 3 19 1000 305 56.0 25.4 .015 .38 .236 5.99
6102UE 4 19 1000 305 73.0 33.2 .015 .38 .261 6.63
12 AWG
6000UE 2 19 500 152 32.0 14.5 .015 .38 .256 6.50
1000 305 58.0 26.4
6001UE 3 19 1000 305 83.0 37.7 .015 .38 .273 6.93
6002UE 4 19 1000 305 111.0 50.4 .018 .46 .308 7.82
Color Code Chart
Cond. No. Color
1Black
2White
3Red
4Green
NEW GENERATION
®CABLES 20.23
20 New Generation®Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Shielded Multi-conductor
CMP FT6 Rated
Product Description
Bare copper conductors, Flamarrest®insulation,
conductors cabled, overall Beldfoil®tape shield
(foil side out) and drain wire, Natural Flamarrest
jacket with rip cord. Sequential footage marking
every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation Flamarrest
Insulation Thickness .009(.229mm)
Shield Beldfoil
Jacket Flamarrest
Approvals
NEC CMP
CEC CMP FT6
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Solid Conductor
Stranded Conductor
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded, Plenum-Rated
Part
No.
Shielded Multi-conductor (NEC CMP and CEC CMP FT6)
22 AWG
6520FE 2 solid C-500 C-152 6.0 2.7 .015 .38 .122 3.10
C-1000 C-305 12.0 5.4
U-1000 U-305 13.0 5.9
1000 305 13.0 5.9
6500FE 2 7 C-500 C-152 5.5 2.5 .015 .38 .128 3.25
U-500 U-152 7.0 3.2
500 152 7.0 3.2
C-1000 C-305 11.0 5.0
U-1000 U-305 13.0 5.9
1000 305 13.0 5.9
6521FE 3 solid 1000 305 16.0 7.3 .015 .38 .129 3.28
6501FE 3 7 500 152 8.0 3.6 .015 .38 .135 3.43
U-1000 U-305 16.0 7.3
1000 305 16.0 7.3
6502FE 4 7 C-500 C-152 9.0 4.1 .015 .38 .147 3.73
500 152 10.0 4.5
U-1000 U-305 19.0 8.6
1000 305 20.0 9.1
6504FE 6 7 C-500 C-152 9.0 4.1 .015 .38 .175 4.45
U-500 U-152 13.5 6.1
500 152 13.5 6.1
U-1000 U-305 26.0 11.8
1000 305 26.0 11.8
6506FE 8 7 U-1000 U-305 33.0 15.0 .015 .38 .190 4.83
1000 305 35.0 15.9
6508FE 10 7 U-1000 U-305 40.0 18.1 .015 .38 .222 5.64
1000 305 42.0 19.0
20 AWG
6420FE 2 solid C-500 C-152 7.0 3.2 .015 .38 .134 3.40
U-1000 U-305 16.0 7.3
1000 305 15.0 6.8
6400FE 2 7 C-500 C-152 7.5 3.4 .015 .38 .142 3.61
U-1000 U-305 17.0 7.7
1000 305 17.0 7.7
6401FE 3 7 U-1000 U-305 21.0 9.5 .015 .38 .150 3.81
1000 305 22.0 10.0
6402FE 4 7 U-1000 U-305 26.0 11.8 .015 .38 .164 4.17
1000 305 27.0 12.3
6405FE 7 7 1000 305 41.0 18.6 .015 .38 .196 4.97
6407FE 9 7 1000 305 52.0 23.6 .015 .38 .229 5.82
Shorting Fold
Color Code Chart
Cond. No. Color
1Black
2Red
3White
4Green
5Brown
6Blue
Cond. No. Color
7Orange
8Yellow
9Purple
10 Gray
11 Pink
12 Tan
Shorting Fold
NEW GENERATION
®CABLES 20.24
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Shielded Multi-conductor
(cont’d.)
CMP FT6 Rated or CL2P Rated
Product Description
Bare copper conductors, Flamarrest®insulation,
conductors cabled, overall Beldfoil®tape shield
(foil side out) and drain wire, Natural Flamarrest
jacket with rip cord. Sequential footage marking
every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation Flamarrest
Insulation Thickness
18 and 16 AWG .009(.229mm)
14 and 12 AWG .011(.279mm)
Shield Beldfoil
Jacket Flamarrest
Approvals
NEC (18 and 16 AWG) CMP
CEC (18 and 16 AWG) CMP FT6
NEC (14 and 12 AWG) CL2P
NEC Articles
18 and 16 AWG 800
14 and 12 AWG 725
Voltage Rating
18 and 16 AWG 300V
14 and 12 AWG 150V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Solid Conductor
Stranded Conductor
Stranding
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded, Plenum-Rated
Part
No.
Shielded Multi-conductor (NEC CMP and CEC CMP FT6)
18 AWG
6320FE 2 solid C-500 C-152 10.5 4.8 .015 .38 .150 3.89
1000 305 22.0 10.0
6300FE 2 7 C-500 C-152 11.0 5.0 .015 .38 .162 4.11
U-500 U-152 12.0 5.4
500 152 12.0 5.4
U-1000 U-305 23.0 10.4
1000 305 23.0 10.4
6301FE 3 7 U-500 U-152 15.5 7.0 .015 .38 .172 4.37
U-1000 U-305 30.0 13.6
1000 305 31.0 14.1
6302FE 4 7 C-250 C-76 8.8 4.0 .015 .38 .188 4.78
U-500 U-152 19.5 8.9
500 152 19.0 8.6
U-1000 U-305 37.0 16.8
1000 305 37.0 16.8
6304FE 6 7 C-250 C-76 12.0 5.4 .015 .38 .226 5.74
U-500 U-152 25.5 11.6
1000 305 52.0 23.6
6306FE 8 7 1000 305 66.0 30.0 .015 .38 .246 6.25
6307FE 9 7 500 152 39.5 18.0 .015 .38 .266 6.76
1000 305 73.0 33.2
6309FE 12 7 500 152 50.5 22.9 .018 .46 .306 7.77
1000 305 99.0 45.0
16 AWG
6200FE 2 19 500 152 16.5 7.5 .015 .38 .184 4.67
1000 305 33.0 15.0
6201FE 3 19 500 152 22.5 10.2 .015 .38 .195 4.95
U-1000 U-305 43.0 19.5
1000 305 45.0 20.5
6202FE 4 19 500 152 29.0 13.2 .015 .38 .215 5.46
1000 305 59.0 26.8
Shielded Multi-conductor (NEC CL2P)
14 AWG
6100FE 2 19 500 152 25.0 11.3 .015 .38 .220 5.59
U-1000 U-305 49.0 22.2
1000 305 51.0 23.1
6101FE 3 19 1000 305 66.0 29.9 .015 .38 .234 5.94
12 AWG
6000FE 2 19 500 152 36.0 16.4 .015 .38 .260 6.60
1000 305 68.0 30.9
Cond. No. Color
1Black
2Red
3White
4Green
5Brown
6Blue
Cond. No. Color
7Orange
8Yellow
9Purple
10 Gray
11 Pink
12 Tan
Shorting Fold
Shorting Fold
(14 to 12 AWG)
Cond. No. Color
1Black
2White
3Red
Color Code Chart (18 to 16 AWG)
NEW GENERATION
®CABLES 20.25
20 New Generation®Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Unshielded Twisted Pairs
CMP FT6 Rated
Product Description
Bare copper conductors, Flamarrest®insulation,
twisted into pairs, multiple pairs cabled together,
Natural Flamarrest jacket with rip cord. Sequential
footage marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation Flamarrest
Insulation Thickness .009(.229mm)
Jacket Flamarrest
Approvals
NEC CMP
CEC CMP FT6
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Solid Conductor
Stranded Conductor
Stranding
No. of
Pairs mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Unshielded, Plenum-Rated
Part
No.
Unshielded Twisted Pairs (NEC CMP and CEC CMP FT6)
22 AWG
6561UE 2 solid 1000 305 19.0 8.6 .015 .38 .188 4.78
6541UE 2 7 U-1000 U-305 19.0 8.6 .015 .38 .199 5.05
1000 305 20.0 9.1
6542UE 3 7 1000 305 27.0 12.2 .015 .38 .212 5.38
6543UE 4 7 1000 305 34.0 15.4 .015 .38 .234 5.94
6545UE 6 7 1000 305 47.0 21.4 .015 .38 .264 6.71
6547UE 9 7 1000 305 69.0 31.4 .018 .46 .318 8.08
18 AWG
6341UE 2 7 500 152 21.0 9.5 .015 .38 .260 6.60
U-1000 U-305 36.0 16.3
1000 305 38.0 17.3
6342UE 3 7 U-1000 U-305 48.0 21.8 .015 .38 .278 7.06
1000 305 50.0 22.7
6343UE 4 7 500 152 37.5 17.0 .015 .38 .314 7.98
1000 305 66.0 30.0
6345UE 6 7 1000 305 95.0 43.2 .018 .46 .355 9.02
6347UE 9 7 1000 305 138.0 62.7 .019 .48 .423 10.74
Color Code Chart
Pair No. Color Combination
1Black & Red
2Black & White
3Black & Green
4Black & Blue
5Black & Yellow
Pair No. Color Combination
6Black & Brown
7Black & Orange
8Red & White
9Red & Green
NEW GENERATION
®CABLES 20.26
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Overall Shielded Twisted Pairs
CMP FT6 Rated
Product Description
Bare copper conductors, Flamarrest®insulation,
twisted into pairs, multiple pairs cabled together,
overall Beldfoil®shield tape (foil side out) with
drain wire, Natural Flamarrest jacket with rip cord.
Sequential footage marking every two feet.
Color Code: See chart below.
Specifications
Conductor Bare Copper
Insulation Flamarrest
Insulation Thickness .009(.229mm)
Shield Beldfoil
Jacket Flamarrest
Approvals
NEC CMP
CEC CMP FT6
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Solid Conductor
Stranded Conductor
Stranding
No. of
Pairs mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded, Plenum-Rated
Part
No.
Overall Shielded Twisted Pairs (NEC CMP and CEC CMP FT6)
22 AWG
6561FE 2 solid 1000 305 21.0 9.5 .015 .38 .193 4.90
6541FE 2 7 U-500 U-152 11.5 5.2 .015 .38 .203 5.16
U-1000 U-305 22.0 10.0
1000 305 23.0 10.4
6542FE 3 7 U-1000 U-305 28.0 12.7 .015 .38 .216 5.49
1000 305 29.0 13.2
6543FE 4 7 U-1000 U-305 35.0 15.9 .015 .38 .238 6.05
1000 305 41.0 18.6
6545FE 6 7 U-1000 U-305 48.0 21.8 .015 .38 .268 6.80
1000 305 50.0 22.7
6547FE 9 7 1000 305 72.0 32.7 .018 .46 .323 8.20
20 AWG
6441FE 2 7 1000 305 31.0 14.1 .015 .38 .228 5.79
6443FE 4 7 U-1000 U-305 49.0 22.2 .015 .38 .269 6.83
1000 305 51.0 23.2
18 AWG
6342FE 3 7 500 152 28.0 12.7 .015 .38 .282 7.16
1000 305 56.0 25.5
6343FE 4 7 500 152 39.5 18.0 .015 .38 .318 8.08
1000 305 74.0 33.6
6345FE 6 7 500 152 50.0 22.7 .018 .46 .359 9.12
1000 305 101.0 45.9
6347FE 9 7 1000 305 145.0 65.8 .019 .48 .427 10.85
Shorting Fold
Color Code Chart
Pair No. Color Combination
1Black & Red
2Black & White
3Black & Green
4Black & Blue
5Black & Yellow
Pair No. Color Combination
6Black & Brown
7Black & Orange
8Red & White
9Red & Green
Shorting Fold
NEW GENERATION
®CABLES 20.27
20 New Generation®Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Shielded
Twisted Pair plus Conductor(s)
CMP FT6 Rated
Product Description
Bare copper conductors, Flamarrest®insulation,
Black/Red twisted pair shielded with Beldfoil®
tape (aluminum side facing in), drain wire,
cabled with additional insulated conductor(s) as
indicated, Natural Flamarrest jacket with rip cord.
Sequential footage marking every two feet.
Color Code: Black & Red pair, White, Green.
Specifications
Conductor Bare Copper
Insulation Flamarrest
Insulation Thickness .009(.229mm)
Shield Beldfoil
Jacket Flamarrest
Approvals
NEC CMP
CEC CMP FT6
NEC Articles 800
Voltage Rating 300V
Temperature Rating 75°C
Applications
Security Systems
Intercom/PA Systems
Sound/Audio Systems
Power-Limited Controls
Stranding
No. of
Pairs +
No. of
Cond. mFt.
Standard
Lengths
mmInchkg
Standard
Unit Weight
Outer Jacket
Thickness Nominal OD
Inch mmLbs.
Security and Alarm Cable
Commercial Applications
Shielded, Plenum-Rated
Part
No.
Shielded Twisted Pair plus Conductor(s) (NEC CMP and CEC CMP FT6)
22 AWG
6501GE 1 STP 7 1000 305 18.0 8.2 .015 .38 .174 4.42
+1/C
6502GE 1 STP 7 U-1000 U-305 21.0 9.5 .015 .38 .180 4.57
+2/C 1000 305 21.0 9.5
20 AWG
6401GE 1 STP 7 1000 305 24.0 10.9 .015 .38 .195 4.95
+1/C
STP = Shielded Twisted Pair(s) • /C = Conductor(s)
Shorting Fold