10/23/2012
RELIABILITY MONITOR REPORT
FOR
QFN Package
MAXIM INTEGRATED
160 RIO ROBLES
SAN JOSE, CA 95134
This Report was prepared by
MAXIM INTEGRATED Reliability Engineering
Summary:
The data in the tables that follow was generated as the result of an on-going Package Reliability
Monitor. The specifc assemblies included in this package monitor are:
The calculated failure rate for this assembly is:
The parameters used to calculate this failure rate are as follows:
Cf: 60% Ea: 0.7 Tu: 25 °C
The reliability data follows. A the start of this data is a description of the assembly vehicle used to
generate this reliability data. The next section is the detailed reliability data for each stress. The reliability
data section includes the latest data available. This report covers data between and
.
10/1/2011 9/30/2012
FITS: 0.5MTTF (YRS): 228311FAILURE RATE:
ASSY SITE PACKAGEPINS
ASE Chung-Li TQFN (Pb-Free)8 ASE Chung-Li TQFN (Pb-Free)10
ASE Chung-Li TQFN (Pb-Free)16 ASE Chung-Li TQFN (Pb-Free)20
ASE Chung-Li TQFN (Pb-Free)24 ASE Chung-Li TQFN (Pb-Free)28
ASE Chung-Li TQFN (Pb-Free)32 ASE Chung-Li TQFN (Pb-Free)36
ASE Chung-Li TQFN (Pb-Free)40 ASE Chung-Li TQFN (Pb-Free)42
ASE Chung-Li TQFN (Pb-Free)44 ASE Chung-Li TQFN (Pb-Free)48
ASE Chung-Li TQFN (Pb-Free)56 ASE Chung-Li TQFN (Pb-Free)68
ATK (Amkor, K) QFN24 ATK (Amkor, K) QFN (Pb-Free)8
ATK (Amkor, K) QFN (Pb-Free)48 ATK (Amkor, K) TQFN (Pb-Free)48
Carsem-S QFN (Pb-Free)23 Carsem-S TQFN (Pb-Free)20
DALLAS-MAXFIL TQFN (Pb-Free)36 Unisem Malaysia TQFN (Pb-Free)24
UTACDG TQFN (Pb-Free)8 UTACDG TQFN (Pb-Free)16
UTACDG TQFN (Pb-Free)20 UTACDG TQFN (Pb-Free)24
UTACDG TQFN (Pb-Free)28 UTACDG TQFN (Pb-Free)32
UTACDG TQFN (Pb-Free)36 UTACDG TQFN (Pb-Free)40
UTACDG TQFN (Pb-Free)48 UTACDG TQFN (Pb-Free)56
UTACDG TQFN (Pb-Free)68 UTL Thailand QFN (Pb-Free)56
UTL Thailand TQFN (Pb-Free)16 UTL Thailand TQFN (Pb-Free)20
UTL Thailand TQFN (Pb-Free)24 UTL Thailand TQFN (Pb-Free)28
UTL Thailand TQFN (Pb-Free)32 UTL Thailand TQFN (Pb-Free)36
UTL Thailand TQFN (Pb-Free)40 UTL Thailand TQFN (Pb-Free)44
UTL Thailand TQFN (Pb-Free)56 UTL Thailand uTQFN (Pb-Free)48
Package Type: QFN
Assembly Information:
12091209 toDate Code Range:
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
500135°C 80 0HIGH TEMP OP LIFE HRS1209 MAX3801UGG
0Total:
Package Type: QFN (Pb-Free)
Assembly Information:
11311126 toDate Code Range:
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000135°C 79 0HIGH TEMP OP LIFE HRS1130 MAX15029AGA/VY+
0Total:
STORAGE LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000150°C 80 0STORAGE LIFE HRS1130 MAX15029AGA/VY+
1000150°C 77 0STORAGE LIFE HRS1131 MAX9684ETN+
0Total:
TEMPERATURE CYCLE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000-65C TO 150C 220 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYSMAX15074EGD+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1126 MAX16924GGM/VY+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1130 MAX15029AGA/VY+
0Total:
TEMPERATURE HUMIDITY BIAS
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
100130C, 85% R.H. 80 0BIASED MOISTURE HRS1130 MAX15029AGA/VY+
0Total:
Package Type: TQFN (Pb-Free)
Assembly Information:
12341007 toDate Code Range:
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000135°C 56 0HIGH TEMP OP LIFE HRSMAX14592EETI+
192135°C 43 0HIGH TEMP OP LIFE HRS1007 MAX8904ETN+
192135°C 45 0HIGH TEMP OP LIFE HRS1029 MAX5971BETI+
600135°C 44 0HIGH TEMP OP LIFE HRS1050 MAX14578AETI+
192135°C 44 0HIGH TEMP OP LIFE HRS1050 MAX14578AETI+
1000135°C 47 0HIGH TEMP OP LIFE HRS1052 MAX17114ETM+CB2
1000135°C 78 0HIGH TEMP OP LIFE HRS1105 MAX16924GTM/V+
1000135°C 46 0HIGH TEMP OP LIFE HRS1105 MAX8798ETX+
1000135°C 46 0HIGH TEMP OP LIFE HRS1105 MAX8798ETX+
1000135°C 75 0HIGH TEMP OP LIFE HRS1109 MAX16924GTM/V+
1000135°C 44 0HIGH TEMP OP LIFE HRS1110 MAX11014BGTM=
1000135°C 45 0HIGH TEMP OP LIFE HRS1110 MAX11014BGTM+
192135°C 80 0HIGH TEMP OP LIFE HRS1112 MAX3948ETE+
240135°C 32 0HIGH TEMP OP LIFE HRS1113 MAX3643ETG+
192135°C 48 0HIGH TEMP OP LIFE HRS1113 MAX3643ETG+
192135°C 79 0HIGH TEMP OP LIFE HRS1114 MAX7370ATG+
192135°C 48 0HIGH TEMP OP LIFE HRS1114 MAX2121ETI+
1000135°C 48 0HIGH TEMP OP LIFE HRS1114 MAX2121ETI+
192135°C 48 0HIGH TEMP OP LIFE HRS1114 MAX2121ETI+
1000135°C 47 0HIGH TEMP OP LIFE HRS1114 MAX2121ETI+
1000135°C 45 0HIGH TEMP OP LIFE HRS1114 MAX9679ETG+
192135°C 80 0HIGH TEMP OP LIFE HRS1116 MAX17497AATE+
500135°C 77 1HIGH TEMP OP LIFE HRS1118 MAX9679ETG+
192125C, 3.3 VOLTS 77 0HIGH TEMP OP LIFE HRS1120 DS4830
192135°C 48 0HIGH TEMP OP LIFE HRS1120 MAX5982BETE+
192135°C 32 0HIGH TEMP OP LIFE HRS1122 MAX2091ETP+
192135°C 48 0HIGH TEMP OP LIFE HRS1122 MAX2091ETP+
192135°C 48 0HIGH TEMP OP LIFE HRS1122 MAX2090ETP+
24135°C 48 0HIGH TEMP OP LIFE HRS1122 MAX2090ETP+
192135°C 80 0HIGH TEMP OP LIFE HRS1122 MAX2091ETP+
1000135°C 50 0HIGH TEMP OP LIFE HRS1123 MAX2769BETI/V+
192135°C 79 0HIGH TEMP OP LIFE HRS1125 MAX14593EETX+
192135°C 80 0HIGH TEMP OP LIFE HRS1125 MAX11131ATI+
192135°C 48 0HIGH TEMP OP LIFE HRS1126 MAX17129ETE+
192135°C 47 0HIGH TEMP OP LIFE HRS1127 MAX9695AETM+
1000135°C 80 0HIGH TEMP OP LIFE HRS1127 MAXEXP7ETE+
1000135°C 80 0HIGH TEMP OP LIFE HRS1127 MAXEXP7ETE+
1000135°C 80 0HIGH TEMP OP LIFE HRS1127 MAXEXP7ETE+
192135°C 48 0HIGH TEMP OP LIFE HRS1129 MAX3636ETM+
240135°C 32 0HIGH TEMP OP LIFE HRS1129 MAX3636ETM+
192135°C 32 0HIGH TEMP OP LIFE HRS1129 MAX3636ETM+
192135°C 48 0HIGH TEMP OP LIFE HRS1129 MAX3636ETM+
192135°C 80 0HIGH TEMP OP LIFE HRS1131 MAX17498AATE+
500135°C 80 0HIGH TEMP OP LIFE HRS1131 MAX9684ETN+
1000135°C 78 0HIGH TEMP OP LIFE HRS1131 MAX9684ETN+
192135°C 80 0HIGH TEMP OP LIFE HRS1132 MAX3711ETG+
1000135°C 45 0HIGH TEMP OP LIFE HRS1132 MAX1781ETM+
1000135°C 77 0HIGH TEMP OP LIFE HRS1132 MAX2363ETM+
1000135°C 77 0HIGH TEMP OP LIFE HRS1132 MAX2363ETM+
1000135°C 77 0HIGH TEMP OP LIFE HRS1132 MAX2363ETM+
192135°C 80 0HIGH TEMP OP LIFE HRS1133 MAX15300ETI+
1000135°C 48 0HIGH TEMP OP LIFE HRS1133 MAX8520ETP+
1000135°C 48 0HIGH TEMP OP LIFE HRS1133 MAX8520ETP+
1000135°C 48 0HIGH TEMP OP LIFE HRS1133 MAX8520ETP+
1024135°C 75 0HIGH TEMP OP LIFE HRS1133 MAX17491GTA+
192135°C 60 0HIGH TEMP OP LIFE HRS1134 MAX2553ETN+
192135°C 48 0HIGH TEMP OP LIFE HRS1134 MAX17135ETJ+
240135°C 48 0HIGH TEMP OP LIFE HRS1134 MAX2553ETN+
192135°C 80 0HIGH TEMP OP LIFE HRS1135 TX27YETH+
192135°C 48 0HIGH TEMP OP LIFE HRS1136 MAX4936ACTO+
192135°C 31 0HIGH TEMP OP LIFE HRS1136 MAX4936ACTO+
192135°C 80 0HIGH TEMP OP LIFE HRS1136 MAX9599AETG+
1000135°C 80 0HIGH TEMP OP LIFE HRS1137 MAX8798AETX+
192135°C 48 0HIGH TEMP OP LIFE HRS1139 MAX5112GTJ+
192135°C 80 0HIGH TEMP OP LIFE HRS1141 MAX5316GTG+
1024135°C 80 0HIGH TEMP OP LIFE HRS1142 MAX9832ETG+
1024135°C 79 0HIGH TEMP OP LIFE HRS1142 MAX9832ETG+
192135°C 76 0HIGH TEMP OP LIFE HRS1143 MAX14616ETX+
192135°C 80 0HIGH TEMP OP LIFE HRS1143 MAX14616ETX+
1000135°C 76 1HIGH TEMP OP LIFE HRS1144 MAX8655ETN+
1000135°C 41 0HIGH TEMP OP LIFE HRS1144 MAX8655ETN+
500135°C 72 0HIGH TEMP OP LIFE HRS1145 MAX98400AETX+
1000135°C 80 0HIGH TEMP OP LIFE HRS1147 MAX9688ETI+
1000135°C 80 0HIGH TEMP OP LIFE HRS1147 MAX9688RETI+
1000135°C 79 0HIGH TEMP OP LIFE HRS1147 MAX9688RETI+
336135°C 20 0HIGH TEMP OP LIFE HRS1148 MAX15301ETJ+
192135°C 80 0HIGH TEMP OP LIFE HRS1150 MAX13366GTE/V+
10000135°C 77 1HIGH TEMP OP LIFE HRS1150 MAX8655ETN+
500135°C 77 0HIGH TEMP OP LIFE HRS1150 MAX8655ETN+
500135°C 80 0HIGH TEMP OP LIFE HRS1150 MAX9832ETG+
500135°C 80 0HIGH TEMP OP LIFE HRS1150 MAX9832ETG+
1000135°C 75 0HIGH TEMP OP LIFE HRS1150 MAX17491GTA+
1000135°C 80 0HIGH TEMP OP LIFE HRS1151 MAX9832ETG+
192135°C 48 0HIGH TEMP OP LIFE HRS1151 MAX2135AETN+
192135°C 48 0HIGH TEMP OP LIFE HRS1152 MAX9695AETM+
192135°C 48 0HIGH TEMP OP LIFE HRS1152 MAX9695AETM+
192135°C 48 0HIGH TEMP OP LIFE HRS1152 MAX9695ETM+
192135°C 48 0HIGH TEMP OP LIFE HRS1152 MAX9695ETM+
1000135°C 79 0HIGH TEMP OP LIFE HRS1152 MAX16922ATPF/V+
524135°C 79 0HIGH TEMP OP LIFE HRS1153 MAX2140ETH+
500135°C 80 0HIGH TEMP OP LIFE HRS1153 MAX2140ETH+
1000135°C 70 0HIGH TEMP OP LIFE HRS1201 MAX98400AETX+
192135°C 80 0HIGH TEMP OP LIFE HRS1202 MAX15202ATE+
192135°C 80 0HIGH TEMP OP LIFE HRS1203 MAX14616ETX+
500135°C 78 0HIGH TEMP OP LIFE HRS1203 MAX2172ETL+
192125C, 3.6 VOLTS 80 0HIGH TEMP OP LIFE HRS1207 DS1886
192135°C 80 0HIGH TEMP OP LIFE HRS1207 MAX2870ETJ+
500135°C 32 0HIGH TEMP OP LIFE HRS1208 MAX2135AETN/V+
1000135°C 74 0HIGH TEMP OP LIFE HRS1208 MAX17491GTA+T
500135°C 48 0HIGH TEMP OP LIFE HRS1209 MAX2058ETL+
500135°C 32 0HIGH TEMP OP LIFE HRS1209 MAX2058ETL+
517135°C 80 0HIGH TEMP OP LIFE HRS1209 MAX3802UTK+
192135°C 79 0HIGH TEMP OP LIFE HRS1211 MAX3947ETE+
192135°C 80 0HIGH TEMP OP LIFE HRS1213 MAX19794ETX+
500135°C 79 0HIGH TEMP OP LIFE HRS1214 MAX14808ETK+
1000135°C 72 0HIGH TEMP OP LIFE HRS1214 MAX98400AETX+
192135°C 80 0HIGH TEMP OP LIFE HRS1215 MAX14634ETE+
192135°C 78 0HIGH TEMP OP LIFE HRS1215 MAX9736AETJ+
192135°C 47 0HIGH TEMP OP LIFE HRS1216 MAX5971BETI+
192135°C 47 0HIGH TEMP OP LIFE HRS1216 MAX5971BETI+
192135°C 46 0HIGH TEMP OP LIFE HRS1216 MAX5971BETI+
192135°C 80 0HIGH TEMP OP LIFE HRS1216 MAX9272GTM+
500135°C 47 0HIGH TEMP OP LIFE HRS1216 MAX9708ETN+
192135°C 80 0HIGH TEMP OP LIFE HRS1216 MAX9736AETJ+
192135°C 80 0HIGH TEMP OP LIFE HRS1217 MAX14616AETX+
192135°C 80 0HIGH TEMP OP LIFE HRS1217 MAX14589EETP+
192125C, 3.6 VOLTS 80 0HIGH TEMP OP LIFE HRS1219 78M6610
192135°C 80 0HIGH TEMP OP LIFE HRS1219 MAX16936RATEA/V
+
500135°C 77 0HIGH TEMP OP LIFE HRS1219 MAX2363ETM+
500135°C 77 0HIGH TEMP OP LIFE HRS1219 MAX2363ETM+
500135°C 77 0HIGH TEMP OP LIFE HRS1219 MAX2363ETM+
500135°C 74 0HIGH TEMP OP LIFE HRS1222 TX27YETH+
500135°C 45 0HIGH TEMP OP LIFE HRS1222 MAX9684ETN+
500135°C 45 0HIGH TEMP OP LIFE HRS1222 MAX9684ETN+
500135°C 45 0HIGH TEMP OP LIFE HRS1222 MAX9684ETN+
500135°C 47 0HIGH TEMP OP LIFE HRS1227 MAX17094ETM+
192135°C 90 0HIGH TEMP OP LIFE HRS1228 MAX5971BETI+
192135°C 45 0HIGH TEMP OP LIFE HRS1228 MAX5971BETI+
1000135°C 85 0HIGH TEMP OP LIFE HRS1228 MAX5971BETI+
192135°C 80 0HIGH TEMP OP LIFE HRS1232 MAX16962RATEA/V
+
192135°C 80 0HIGH TEMP OP LIFE HRS1232 TX27YETH+
192135°C 80 0HIGH TEMP OP LIFE HRS1233 TX27YETH+
544135°C 87 0HIGH TEMP OP LIFE HRS1234 TX27YETH+
3Total:
STORAGE LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
500150°C 50 0STORAGE LIFE HRS1031 MAX16946GTE/V+
1000150°C 80 0STORAGE LIFE HRS1127 MAXEXP7ETE+
1000150°C 80 0STORAGE LIFE HRS1127 MAXEXP7ETE+
1000150°C 80 0STORAGE LIFE HRS1127 MAXEXP7ETE+
1000150°C 77 0STORAGE LIFE HRS1131 MAX9684ETN+
1000150°C 77 0STORAGE LIFE HRS1131 MAX9684ETN+
1000150°C 77 1STORAGE LIFE HRS1132 MAX1781ETM+
1000150°C 77 0STORAGE LIFE HRS1132 MAX2363ETM+
500150°C 77 0STORAGE LIFE HRS1132 MAX2363ETM+
1000150°C 77 0STORAGE LIFE HRS1132 MAX2363ETM+
1000150°C 77 0STORAGE LIFE HRS1132 MAX2363ETM+
1048150°C 30 0STORAGE LIFE HRS1133 MAX8520ETP+
1048150°C 30 0STORAGE LIFE HRS1133 MAX8520ETP+
1000150°C 30 0STORAGE LIFE HRS1133 MAX8520ETP+
500150°C 50 1STORAGE LIFE HRS1134 MAX16948AGTE/V+
1000150°C 80 0STORAGE LIFE HRS1142 MAX9832ETG+
1000150°C 80 0STORAGE LIFE HRS1142 MAX9832ETG+
1048150°C 45 0STORAGE LIFE HRS1142 MAX15021ATI+
1000150°C 78 0STORAGE LIFE HRS1144 MAX8655ETN+
1000150°C 77 0STORAGE LIFE HRS1145 PHY1078-01
WHISKERS < 50um, Class 1/1A
TC & HTS
77 0VISUAL INSPECTION 1145 PHY1078-01
24150°C 500 0STORAGE LIFE HRS1145 MAX98400AETX+
500150°C 50 0STORAGE LIFE HRS1145 MAX16948AGTE/V+
1065150°C 80 0STORAGE LIFE HRS1147 MAX9688ETI+
1065150°C 80 0STORAGE LIFE HRS1147 MAX9688RETI+
1065150°C 80 0STORAGE LIFE HRS1147 MAX9688RETI+
500150°C 50 0STORAGE LIFE HRS1150 MAX8795AGTJ+
1000150°C 78 0STORAGE LIFE HRS1150 MAX8655ETN+
1000150°C 78 0STORAGE LIFE HRS1150 MAX8655ETN+
500150°C 50 0STORAGE LIFE HRS1150 MAX13366GTE/V+
500150°C 50 0STORAGE LIFE HRS1151 MAX8795AGTJ+
1000150°C 80 0STORAGE LIFE HRS1151 MAX9832ETG+
1000150°C 80 0STORAGE LIFE HRS1152 MAX19757ETX+
500150°C 50 1STORAGE LIFE HRS1152 MAX16922ATPF/V+
1000150°C 76 0STORAGE LIFE HRS1201 PHY1078-01
WHISKERS < 50um, Class 1/1A
TC & HTS
76 0VISUAL INSPECTION 1201 PHY1078-01
500150°C 80 0STORAGE LIFE HRS1201 MAX98400AETX+
1000150°C 300 0STORAGE LIFE HRS1201 MAX98400AETX+
1000150°C 77 0STORAGE LIFE HRS1202 PHY1078-01
48150°C 50 1STORAGE LIFE HRS1205 MAX2091ETP+
1000150°C 77 0STORAGE LIFE HRS1207 MAX9684ETN+
1000150°C 77 0STORAGE LIFE HRS1207 MAX9684ETN+
1000150°C 77 0STORAGE LIFE HRS1207 MAX9684ETN+
1000150°C 79 0STORAGE LIFE HRS1211 MAX17806EUI+
1000150°C 50 0STORAGE LIFE HRS1215 MAX9737ETG+
1000150°C 77 0STORAGE LIFE HRS1215 MAX1781ETM+
1000150°C 77 0STORAGE LIFE HRS1215 MAX1781ETM+
1000150°C 77 0STORAGE LIFE HRS1215 MAX1781ETM+
1000150°C 80 0STORAGE LIFE HRS1215 MAX9736AETJ+
1000150°C 50 0STORAGE LIFE HRS1216 MAX9708ETN+
1000150°C 50 0STORAGE LIFE HRS1218 MAX9737ETG+
1000150°C 50 0STORAGE LIFE HRS1219 MAX16936RATEA/V
+
1000150°C 77 0STORAGE LIFE HRS1219 MAX2363ETM+
1000150°C 77 0STORAGE LIFE HRS1219 MAX2363ETM+
1000150°C 77 0STORAGE LIFE HRS1219 MAX2363ETM+
500150°C 80 0STORAGE LIFE HRS1222 MAX9684ETN+
500150°C 80 0STORAGE LIFE HRS1222 MAX9684ETN+
500150°C 80 0STORAGE LIFE HRS1222 MAX9683ETN+
500150°C 80 0STORAGE LIFE HRS1223 MAX14576QEVB+
500150°C 80 0STORAGE LIFE HRS1223 MAX14576QEVB+
500150°C 80 0STORAGE LIFE HRS1223 MAX14576QEVB+
500150°C 50 0STORAGE LIFE HRS1226 MAX16834ATP+
500150°C 80 0STORAGE LIFE HRS1227 MAX17094ETM+
500150°C 80 0STORAGE LIFE HRS1227 MAX17094ETM+
4Total:
TEMPERATURE CYCLE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1050 MAX8795AGTJ/V+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1123 MAX2769BETI/V+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1127 MAXEXP7ETE+
1000-65C TO 150C 78 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1127 MAXEXP7ETE+
1000-65C TO 150C 78 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1127 MAXEXP7ETE+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1130 MAX15022ATI+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1130 MAX15022ATI+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1130 MAX15022ATI+
1000-65C TO 150C 72 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1131 MAX9684ETN+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1131 MAX9684ETN+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1131 MAX15022ATI+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1131 MAX15022ATI+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1131 MAX15022ATI+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1132 MAX13362ATL/V+
1000-65C TO 150C 76 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1132 MAX1781ETM+
1000-65C TO 150C 77 1TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1132 MAX1781ETM+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1132 MAX2363ETM+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1132 MAX2363ETM+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1132 MAX2363ETM+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1133 MAX8520ETP+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1133 MAX8520ETP+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1133 MAX8520ETP+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1134 MAX16948AGTE/V+
100-65C TO 150C 996 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1136 MAX8643ETG+
1000-65C TO 150C 596 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1138 MAX8643ETG+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1141 MAX17018DATL/V+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1142 MAX9832ETG+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1142 MAX9832ETG+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1143 MAX9695ETM+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1143 MAX17018DATL/V+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1143 MAX16946GTE/V+
1000-65C TO 150C 78 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1144 MAX8655ETN+
WHISKERS < 50um, Class 1/1A
TC & HTS
77 0VISUAL INSPECTION 1145 PHY1078-01
1000-55C TO 125C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1145 PHY1078-01
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1145 MAX16948AGTE/V+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1145 MAX16948AGTE/V+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1146 MAX16946GTE+
50-65C TO 150C 2541 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1148 MAX8643ETG+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1150 MAX8795AGTJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1150 MAX8795AGTJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1150 MAX8795AGTJ+
1000-65C TO 150C 78 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1150 MAX8655ETN+
1000-65C TO 150C 78 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1150 MAX8655ETN+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1150 MAX13366GTE/V+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1151 MAX8795AGTJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1151 MAX8795AGTJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1151 MAX8795AGTJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1151 MAX9832ETG+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1152 MAX2769BETI/V+
500-65C TO 150C 79 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1152 MAX19757ETX+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1152 MAX3646ETG+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1152 MAX3646ETG+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1152 MAX16946GTE/V+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1152 MAX16922ATPF/V+
1000-55C TO 125C 76 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1201 PHY1078-01
WHISKERS < 50um, Class 1/1A
TC & HTS
76 0VISUAL INSPECTION 1201 PHY1078-01
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1201 MAX98400AETX+
WHISKERS < 50um, Class 1/1A
TC & HTS
77 0VISUAL INSPECTION 1202 PHY1078-01
1000-55C TO 125C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1202 PHY1078-01
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1202 MAX16946GTE/V+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1207 MAX9684ETN+
500-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1207 MAX9684ETN+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1207 MAX9684ETN+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1208 MAX3646ETG+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1208 MAX3646ETG+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1209 MAX2769BETI/V+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1211 MAX9739ETG+
500-65C TO 150C 80 1TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1215 MAX9737ETG+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1215 MAX1781ETM+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1215 MAX1781ETM+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1215 MAX1781ETM+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1215 MAX9736AETJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1215 MAX9736AETJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1216 MAX9708ETN+
1000-65C TO 150C 75 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1216 MAX9736AETJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1218 MAX9737ETG+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1218 MAX9737ETG+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1218 MAX9736BETJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1218 MAX9736BETJ+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1219 MAX16936RATEA/V
+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1219 MAX2363ETM+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1219 MAX2363ETM+
1000-65C TO 150C 77 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1219 MAX2363ETM=
200-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1222 TX27TETH+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1222 MAX9684ETN+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1222 MAX9684ETN+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1222 MAX9684ETN+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1223 MAX14576QEVB+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1223 MAX14576QEVB+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1223 MAX14576QEVB+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1227 MAX9708ETN/V+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1227 MAX17094ETM+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1227 MAX17094ETM+
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1227 MAX17094ETM+
200-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1232 TX27YETH+
2Total:
TEMPERATURE HUMIDITY BIAS
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
96130C, 85% R.H. 80 0BIASED MOISTURE HRS1050 MAX8795AGTJ/V+
100130C, 85% R.H. 35 0BIASED MOISTURE HRS1102 MAX9708ETN+
96130C, 85% R.H. 33 0BIASED MOISTURE HRS1130 MAX15022ATI+
100130C, 85% R.H. 33 0BIASED MOISTURE HRS1130 MAX15022ATI+
100130C, 85% R.H. 34 0BIASED MOISTURE HRS1131 MAX15022ATI+
100130C, 85% R.H. 34 0BIASED MOISTURE HRS1131 MAX15022ATI+
100130C, 85% R.H. 46 0BIASED MOISTURE HRS1131 MAX15022ATI+
500130C, 85% R.H. 30 1BIASED MOISTURE HRS1132 MAX1781ETM+
100130C, 85% R.H. 29 0BIASED MOISTURE HRS1142 MAX15021ATI+
96130C, 85%R.H., 3.6V 45 0HAST HRS1145 PHY1078-01
96130C, 85% R.H. 80 0BIASED MOISTURE HRS1146 MAX16946GTE+
96130C, 85% R.H. 80 0BIASED MOISTURE HRS1150 MAX8795AGTJ+
100130C, 85% R.H. 38 0BIASED MOISTURE HRS1150 MAX8655ETN+
100130C, 85% R.H. 39 0BIASED MOISTURE HRS1150 MAX8655ETN+
96130C, 85% R.H. 80 1BIASED MOISTURE HRS1151 MAX8795AGTJ+
96130C, 85% R.H. 80 0BIASED MOISTURE HRS1151 MAX8795AGTJ+
100130C, 85% R.H. 46 0BIASED MOISTURE HRS1152 MAX19757ETX+
96130C, 85%R.H., 3.6V 40 0HAST HRS1201 PHY1078-01
100130C, 85% R.H. 44 0BIASED MOISTURE HRS1201 MAX98400AETX+
96130C, 85%R.H., 3.6V 40 0HAST HRS1202 PHY1078-01
100130C, 85% R.H. 80 0BIASED MOISTURE HRS1202 MAX16946GTE/V+
100130C, 85% R.H. 45 0BIASED MOISTURE HRS1207 MAX9684ETN+
100130C, 85% R.H. 45 0BIASED MOISTURE HRS1207 MAX9684ETN+
100130C, 85% R.H. 35 0BIASED MOISTURE HRS1222 MAX9684ETN+
100130C, 85% R.H. 45 0BIASED MOISTURE HRS1222 MAX9684ETN+
100130C, 85% R.H. 45 0BIASED MOISTURE HRS1222 MAX9684ETN+
2Total:
UNBIASED MOISTURE RESISTANCE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1050 MAX8795AGTJ/V+
100085 C/85% R.H. 19 0MOISTURE SOAK HRS1105 MAX8798ETX+
100085 C/85% R.H. 45 0MOISTURE SOAK HRS1105 MAX8798ETX+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1106 MAX9708ETN+
100085 C/85% R.H. 30 0MOISTURE SOAK HRS1110 MAX11014BGTM+
100085 C/85% R.H. 29 0MOISTURE SOAK HRS1110 MAX11014BGTM+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1130 MAX15022ATI+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1130 MAX15022ATI+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1131 MAX15022ATI+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1131 MAX15022ATI+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1131 MAX15022ATI+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1134 MAX16948AGTE/V+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1141 MAX17018DATL/V+
100130C, 85% R.H. 76 0MOISTURE SOAK HRS1142 MAX15021ATI+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1143 MAX17018DATL/V+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1143 MAX16946GTE/V+
100130C, 85% R.H. 77 0MOISTURE SOAK HRS1144 MAX8655ETN+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1145 MAX16948AGTE/V+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1145 MAX16948AGTE/V+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1146 MAX16946GTE+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1150 MAX8795AGTJ+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1150 MAX8795AGTJ+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1150 MAX8795AGTJ+
100130C, 85% R.H. 77 0MOISTURE SOAK HRS1150 MAX8655ETN+
100130C, 85% R.H. 77 0MOISTURE SOAK HRS1150 MAX8655ETN+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1151 MAX8795AGTJ+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1151 MAX8795AGTJ+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1151 MAX8795AGTJ+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1152 MAX2769BETI/V+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1152 MAX16946GTE/V+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1202 MAX16946GTE/V+
100130C, 85% R.H. 77 0MOISTURE SOAK HRS1227 MAX9708ETN/V+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1227 MAX17094ETM+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1227 MAX17094ETM+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1227 MAX17094ETM+
0Total:
Package Type: uTQFN (Pb-Free)
Assembly Information:
N/A1130 toDate Code Range:
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000135°C 80 0HIGH TEMP OP LIFE HRS1130 MAX11871ETM+
1000135°C 80 0HIGH TEMP OP LIFE HRS1140 MAX11871ETM+
1000135°C 77 0HIGH TEMP OP LIFE HRS1224 MAX11871EVM+
1000135°C 77 0HIGH TEMP OP LIFE HRS1224 MAX11871EVM+
1000135°C 77 0HIGH TEMP OP LIFE HRS1224 MAX11871EVM+
0Total:
STORAGE LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000150°C 80 0STORAGE LIFE HRS1130 MAX11871ETM+
1000150°C 80 0STORAGE LIFE HRS1224 MAX11871EVM+
1000150°C 80 0STORAGE LIFE HRS1224 MAX11871EVM+
1000150°C 80 0STORAGE LIFE HRS1224 MAX11871EVM+
0Total:
TEMPERATURE CYCLE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
500-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1130 MAX11871ETM+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1224 MAX11871EVM+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1224 MAX11871EVM+
1000-65C TO 150C 80 0TEMP CYCLE, 5' RAMP,
10' DWELL
CYS1224 MAX11871EVM+
0Total:
TEMPERATURE HUMIDITY BIAS
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
100130C, 85% R.H. 35 0BIASED MOISTURE HRS1224 MAX11871EVM+
100130C, 85% R.H. 35 0BIASED MOISTURE HRSN/A MAX11871ETM+
0Total:
FITS: 0.5MTTF (YRS): 228311FAILURE RATE: