SPECIFICATION
40W Single Output Switching Power Supply DRA-40 series
MODEL
CONSTANT CURRENT REGION
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.4
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
400ms, 90ms/230VAC 800ms, 90ms/115VAC at full load
50ms/230VAC 10ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
47 ~ 63Hz
85%
28.98 ~ 37.26V
87%
0.8A/115VAC 0.6A/230VAC
COLD START 30A/115VAC 60A/230VAC
95 ~ 108% rated output power
14.49 ~ 18.63V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1 approved
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61204-3, light industry level, criteria A
-30 ~ +70 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 55 ) on output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
439.3K hrs min. MIL-HDBK-217F (25 )℃
40*90*100mm (W*H*D)
0.3Kg; 42pcs/13.6Kg/0.82CUFT
DRA-40-24
3~24V
1.7A
0 ~ 1.7A
40.8W
150mVp-p
24 ~ 30V
±1.0%
±0.5%
±0.5%
DRA-40-12
3~12V
3.34A
0 ~ 3.34A
40.08W
120mVp-p
12 ~ 15V
±1.0%
±0.5%
±0.5%
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
SAFETY &
EMC
(Note 5)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power
supplies. (as available on http://www.meanwell.com)
6. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded
permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
EMC IMMUNITY
EMC EMISSION
DC VOLTAGE 24V12V
File Name:DRA-40-SPEC 2017-07-07