SPECIFICATION
File Name:IDPC-45-SPEC 2017-09-14
MODEL
OUTPUT
SETUP TIME Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
SHORT CIRCUIT
<0.75mA / 277VAC
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
408.8Khrs min. MIL-HDBK-217F (25 )℃
0.14Kg; 81pcs/ 12.5Kg/ 1.32CUFT
ENVIRONMENT
SAFETY &
EMC
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
SAFETY STANDARDS
Compliance to EN55015, EN61000-3-2 Class C ( ) ; EN61000-3-3,GB17743,GB17625.1@load 60%≧
EMC IMMUNITY
EMC EMISSION
120*66.5*25mm(L*W*H)
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level( )surge immunity:Line-Line:1KV
UL8750, CSA C22.2 NO.250.13-12; ENEC EN61347-1, EN61347-2-13, EN62384,GB19510.1,GB19510.14 approved
TOTAL HARMONIC DISTORTION
VOLTAGE RANGE Note.3
IDPC-45 -350 IDPC-45 -700 IDPC-45 -1400
350mA 700mA 1400mA
33.25W 44.8W 44.8W
118V
500ms / 230VAC 1200ms/115VAC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
86% 85% 83%
0.6A/115VAC 0.4A/230VAC 0.3A/277VAC
COLD START 30A(twidth= s measured at 50% Ipeak) at 230VAC100μ;Per NEMA 410
57 ~ 95V 38 ~ 64V 19 ~ 32V
84V 50V
IDPC-45 -500
500mA
45W
85%
54 ~ 90V
115V
IDPC-45 -1050
1050mA
45.15W
84%
26 ~ 43V
63V
RATED CURRENT
RATED POWER
CURRENT TOLERANCE
CONSTANT CURRENT REGION
Note.2
OPEN CIRCUIT VOLTAGE
(max.)
CURRENT RIPPLE
±7.0%
5% max. @rated current
THD< 20%(@load 60%/115VAC,230VAC; @load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION” section)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
(Please refer to "STATIC CHARACTERISTIC" section)
90 ~ 295VAC 127 ~ 417VDC
AUXILIARY DC OUTPUT
Note.5
Nominal 12V(deviation 11.4~12.6)@50mA for IDPC-45A only
45W Constant Current Mode LED Driver IDPC-45 series
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
5. There is no design of short circuit protection for the Auxiliary DC output; this function can not be used when dimming input terminals(DIM+,DIM-)
are short circuit or when it is no load or short circuit at output(Vo+,Vo-).
6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be
affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7.The DALI version driver does not support the bit 1: Lamp failure in the Command 144 Query status of the DALI standard.
NO LOAD/STANDBY
POWER CONSUMPTION
WORKING TEMP.
Ta=-20 ~ +40 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)℃
No load power consumption<0.5W for Blank-Type,<1.2W for IDPC-45A
Standby power consumption<0.5W for DA-Type
DALI STANDARDS Compliance to IEC62386-101, 102 for DA-Type only
Hiccup mode,auto-recovery after fault condition is removed for DAtype;
Hiccup mode,re-power on to recovery for other type