355
JJM-RELAYS
HALF-SIZE
AUTOMOTIVE RELAY
mm inch
13.9
.547
12
.472
15.5
.610
FEATURES
• Compact (half-size).
The base area is approximately half the
size of conventional (JSM) relays. The
controller unit can be made more com-
pact.
Base area has been reduced by one half
• Perfect for automobile electrical sys-
tems.
Over 2
×
10
5
openings possible with a 14
V DC motor load, an inrush current of 25
A, and steady state current of 5 A.
(N.O. side)
• Plastic sealed type.
Plastically sealed for automatic cleaning.
JSM JJM
16
.630
22
.866
12
.472
15.5
.610
SPECIFICATIONS
Contact
Coil
Characteristics
Arrangement 1 Form A 1 Form C
Contact material Silver alloy
Initial contact resistance, max.
(By voltage drop 6V DC 1A) 100 m
Ω
Rating
(resistive
load)
Nominal switching
capacity 20 A 14 V DC 20 A 14 V DC
(N.O.)
10 A 14 V DC
(N.C.)
Max. switching power 400 W
Max. switching voltage 16 V DC
Max. carrying current
35 A (12V, at 20
°
C 68
°
F for 2 minutes)
25 A (12V, at 20
°
C 68
°
F for 1 hour)
30 A (12V, at 85
°
C 185
°
F for 2 minutes)
20 A (12V, at 85
°
C 185
°
F for 1 hour)
Expected
life (min.
operations)
Mechanical
(at 120cpm) 10
7
Electrical
(at rated
load)
Resistive 10
5
*
1
10
5
(N.O.)*
2
10
5
(N.C.)*
3
Motor
load 2
×
10
5
*
4
5
×
10
4
*
5
2
×
10
5
(N.O.)*
6
5
×
10
4
(N.O.)*
7
2
×
10
5
(N.C.)*
8
Nominal operating power 640 mW
Max. operating speed (at rated load) 20 cpm
Initial insulation resistance*
9
Min. 100 m
Ω
(at 500 V DC)
Initial breakdown
voltage*
10
Between open contacts 500 Vrms for 1min.
Between contact and coil 500 Vrms for 1min.
Operate time*
11
(at nominal voltage) Max. 10 ms
(at 20
°
C 68
°
F)
Release time (without diode)*
11
(at nominal voltage) Max. 10 ms
(at 20
°
C 68
°
F)
Shock resistance Functional*
12
Min. 100 m/s
2
{10 G}
Destructive*
13
Min. 1,000 m/s
2
{100 G}
Vibration resistance Functional*
14
10 to 100 Hz,
Min. 44.1 m/s
2
{4.5 G}
Destructive 10 to 100 Hz,
Min. 44.1 m/s
2
{4.5 G}
Conditions in case of opera-
tion, transport and storage*
15
(Not freezing and condens-
ing at low temperature)
Ambient
temp. –40 to +85
°
C
–40 to +185
°
F
Humidity 5 to 85% R.H.
Unit weight Approx. 5 g .176 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
at 20 A 14 V DC, at 20 cpm
*
2
at 20 A 14 V DC
*
3
at 10 A 14 V DC, at 20 cpm
*
4
at 5 A (steady), 25 A (inrush) 14 V DC
*
5
at 20 A 14 V DC (Motor lock), operating frequency: 0.5 s ON, 9.5 s OFF
*
6
at 5A (steady), 25 A (inrush) 14 V DC
*
7
at 20 A 14 V DC (Motor lock)
*
8
at peak 20 A 14 V DC (Braking current) operating frequency: 0.5 s ON, 9.5 s OFF
*
9
Measurement at same location as "Initial break down voltage" section.
*
10
Detection current: 10mA
*
11
Excluding contact bounce time.
*
12
Half-wave pulse of sine wave: 11 ms; detection time: 10
µ
s
*
13
Half-wave pulse of sine wave: 6 ms
*
14
Detection time: 10
µ
s
*
15
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
TYPICAL APPLICATIONS
Power windows, auto door lock,
electrically powered sun roof, electrically
powered mirror, cornerring lamp.
ORDERING INFORMATION
Contact arrangement Coil voltage(DC)
1a:
1: 1 Form A
1 Form C 12 V
Ex. JJM 1a 12 V–
(Note) Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.