DS
ORDERING INFORMATION
Long seller backed
by product variety and
high reliability DS RELAYS
FEATURES
1. Breakthrough height of 9.8 mm .386
inch beats the 10 mm .394 inch limit
1c and 2c all have the same height
(9.8 mm .386 inch). The width of the
relay is also the same (9.9 mm .390
inch). Since the only size variable is
the length, the shared form makes
mounting on printed printing wiring
boards easy.
2. Suitable for use in difficult
environments
Epo xy resin seals the parts and cut off
the external atmosphere, thus enabling
use in difficult environments.
3. Can be used with automatic solder
and automatic wash systems
Automatic soldering and automatic
washing can be carried out once the
parts are mounted on PC boards.
4. Gold-clad twin contacts ensure high
reliability
Highly stable gold cladding on the
contacts ensures that contact
resistance changes little over time.
Furthermore, the use of twin contacts,
a configuration that performs with
superior contact reliability, ensures
extremely low contact failure rates
even under low level loads.
5. Polarized magnetic circuits realize
resistance to shock and vibration
High-performance polarized magnetic
circuits that utilize the energy of
permanent magnets have made it
possible to create relays with strong
resistance to shock and vibration.
6. DIL terminal array enab les use of IC
sockets
7. Widening scope of application with
multicontact latching
In addition to single side stable types,
you can tak e advantage of the memory
of functions of convenient 1 coil or 2
coil latching relays.
TYPICAL APPLICATIONS
Besides telecommunications, measuring
devices, office equipment, computers
and related equipment, DS relays are
also recommended for a broad range of
applications including business devices,
audio systems, and industrial equipment.
Nominal coil voltage
DC 1.5, 3, 5, 6, 9, 12, 24, 48 V
Contact arrangement
1: 1 Form C
2: 2 Form C
DS E
Operating function
Nil:
L:
L2:
Single side stable
1 coil latching
2 coil latching
Sensitivity
S: 200 mW nominal operating power
Note: 1 coil latching type are manufactured by lot upon receipt of order.
ASCTB17E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
RoHS compliant
DS
TYPES
1. High sensitivity type
Standard packing: Tube: 50 pcs.; Case: 500 pcs.
Note: 1 coil latching type are manufactured by lot upon receipt of order.
RATING
1. Coil data
1) Single side stable type
2) 2 coil latching type
Contact
arrangement Nominal coil
voltage Single side stable type 2 coil latching type
Part No. Part No.
1 Form C
1.5V DC DS1E-S-DC1.5V DS1E-SL2-DC1.5V
3V DC DS1E-S-DC3V DS1E-SL2-DC3V
5V DC DS1E-S-DC5V DS1E-SL2-DC5V
6V DC DS1E-S-DC6V DS1E-SL2-DC6V
9V DC DS1E-S-DC9V DS1E-SL2-DC9V
12V DC DS1E-S-DC12V DS1E-SL2-DC12V
24V DC DS1E-S-DC24V DS1E-SL2-DC24V
48V DC DS1E-S-DC48V DS1E-SL2-DC48V
2 Form C
3V DC DS2E-S-DC3V DS2E-SL2-DC3V
5V DC DS2E-S-DC5V DS2E-SL2-DC5V
6V DC DS2E-S-DC6V DS2E-SL2-DC6V
9V DC DS2E-S-DC9V DS2E-SL2-DC9V
12V DC DS2E-S-DC12V DS2E-SL2-DC12V
24V DC DS2E-S-DC24V DS2E-SL2-DC24V
48V DC DS2E-S-DC48V DS2E-SL2-DC48V
Type Nominal coil
voltage Pick-up voltage
(at 20°C 68°F)Drop-out voltage
(at 20°C 68°F)
Nominal operating
current [±10%]
(at 20°C 68°F)
Coil resistance
[±10%]
(at 20°C 68°F)
Nominal operating
power Max. applied voltage
(at 50°C 122°F)
High
sensitivity
(S) type
1.5V DC
1 Form C:
80%V or less of
nominal voltage
2 Form C:
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
133.3mA 11.3
200mW
1 Form C:
160%V of
nominal voltage
2 Form C:
200%V of
nominal voltage
3V DC 66.7mA 45
5V DC 40.0mA 125
6V DC 33.3mA 180
9V DC 22.2mA 405
12V DC 16.7mA 720
24V DC 8.3mA 2,880
48V DC 4.2mA 11,520
Type Nominal coil
voltage Set voltage
(at 20°C 68°F)Reset voltage
(at 20°C 68°F)
Nominal operating
current [±10%]
(at 20°C 68°F)
Coil resistance
[±10%]
(at 20°C 68°F)
Nominal operating
power Max. applied voltage
(at 50°C 122°F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
High
sensitivity
(S) type
1.5V DC 1 Form C:
80%V or less of
nominal voltage
2 Form C:
70%V or less of
nominal voltage
(Initial)
1 Form C:
80%V or less of
nominal voltage
2 Form C:
70%V or less of
nominal voltage
(Initial)
120mA 120mA 12.512.5
180mW 180mW
1 Form C:
160%V of
nominal voltage
2 Form C:
200%V of
nominal voltage
3V DC 60mA 60mA 5050
5V DC 36mA 36mA 139139
6V DC 30mA 30mA 200200
9V DC 20mA 20mA 450450
12V DC 15mA 15mA 800800
24V DC 7.5mA 7.5mA 3,2003,200
48V DC 3.75mA 3.75mA 12,80012,800
ASCTB17E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
DS
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (TX/TX-S/TX-D relay AgPd contact type are available for low level load switching [10V DC, 10mA max. level])
*2 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*3 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
Characteristics Item Specifications
Contact Arrangement 1 Form C 2 Form C
Initial contact resistance, max. Max. 50 m (By voltage drop 6 V DC 1A)
Contact material Ag+Au clad
Rating
Nominal switching capacity 2 A 30 V DC (resistive load)
Max. switching power 60 W, 125 VA (resistive load)
Max. switching voltage 220 V DC, 250 V AC
Max. carrying current 3 A
Min. switching capacity (Reference value)*110µA 10m V DC
Nominal operating power Single side stable (S type: 200 mW); latching (S type: 180 mW)
Electrical
characteristics
Insulation resistance (Initial) Min. 100M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min.
(500 Vrms for 1min: 1 Form C type) (Detection current: 10mA.)
Between contact and coil 1,500 Vrms for 1min.
(1,000 Vrms for 1min: 1 Form C type) (Detection current: 10mA.)
Temperature rise Max. 65°C
(By resistive method, nominal coil voltage applied to the coil, contact carrying current: 2A.)
Operate time [Set time] (at 20°C 68°F)Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, e xcluding contact bounce time .)
Release time [Reset time] (at 20°C 68°F)Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, e xcluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance Functional*2Min. 490 m/s2Min. 490 m/s2
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life Mechanical Min. 108 (107: 1 Form C latching type) (at 600 cpm)
Electrical Min. 5×105 rated load (at 60 cpm)
Conditions Conditions for operation, transport and storage*3Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 60 cpm
Unit weight Approx. 3 g .11 oz Approx. 4g .14oz
ASCTB17E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
DS
REFERENCE DATA
1. Maximum switching capacity 2. Life curve (Resistive load) 3. Contact reliability for AC loads
Tested sample: DS2E-S-DC24V 10 pcs.
Operating speed: 20 cpm.
Detection level: 200 m
10mV
10V
100V
1,000V
10µA 100mA 1A
Switching current
Contact voltage, DC
10
100
1,000
102
Switching current, A
No. of operations, ×104
30 V DC
125 V AC
0.1
0.2
0.5
1.0
2.0
5.0
10.0
30.0
50.0
70.0
95.0
99.0
99.9
100 100 1,000
1A 125V AC
0.5A 250V AC
0.3A 250V AC
0.5A 125V AC
No. of operations, ×10
4
Weibull
probability data
F(t), %
4. Operate and release time characteristics
(2 Form C single side stable type)
Test condition: Without diode connected to coil in
parallel
5-(1). Influence of adjacent mounting
(1 Form C) 5-(2). Influence of adjacent mounting
(2 Form C)
1
2
3
4
080 100 120
Release time (mean)
Operate time (mean)
Coil applied voltage, %
Operate and release time, ms
–10
0
10
–10
0
10
510
Inter-relay distance , mm inch
Pick-up voltage
Drop-out voltage
(1) (2) (3)
OFF OFF
ON ON
OFF OFF
ON ON
Rate of change, % Rate of change, %
.197 .394
–10
0
10
–10
0
10
510
OFF OFF
ON ON
OFF OFF
ON ON
Inter-relay distance , mm inch
Pick-up voltage
Drop-out voltage
(1) (2) (3)
Rate of change, % Rate of change, %
.197 .394
ASCTB17E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
DS
DIMENSIONS (mm inch)
DS (1 Form C)
Single side stable, 2 coil latching
External dimensions
General tolerance: ±0.3 ±.012
5.08
.200
0.6
.024
3.4
.134 0.3
.012
9.9
.390
9.3
.366
15
7.62
9.9
.590 .390
.024
0.6
7.62
.300 .300
5.6
.221
Note: External dimensions of 1 coil latching types are same as single side stable type.
PC board pattern (Bottom view)
Single side stable 2 coil latching
.100
.100
5.08 7.62
5-.035 dia.
7.62
2.54
.200 .300
2.54 5-0.9 dia.
.300
.100
.100
2.54
5.08 7.62
.200 .300
6-.035 dia.
2.54 6-0.9 dia.
7.62
.300
Schematic (Bottom view)
Single side stable
(Deenergized condition)
2 coil latching
(Reset condition)
Tolerance: ±0.1 ±.004
12
16
10 7
12
13 6
10 7
CAD Data
DS (2 Form C)
Single side stable External dimensions
General tolerance: ±0.3 ±.012
0.3
.012
9.9
.390
20
.780
.024
0.6
7.62
.300
7.62
.300
5.6
.221
3.4
.134
9.9
.390
9.3
.366
0.6
.024
5.08
.200
5.08
.200
Note: External dimensions of 1 coil latching types are same as single side stable type.
PC board pattern (Bottom view)
.100
.100
2.54
5.08 5.08 7.62
.200 .200 .300
8-.035 dia.
2.54 8-0.9 dia.
7.62
.300
Schematic (Bottom view)
(Deenergized condition)
Tolerance: ±0.1 ±.004
8
91316
64
11
1
CAD Data
DS (2 Form C)
2 coil latching External dimensions
General tolerance: ±0.3 ±.012
2.54
.100
0.3
.012
9.9
.390
20
.780
.024
0.6
7.62
.300
5.6
.221
0.6
.024
5.08
.200 5.08
.200
5.08
.200
3.4
.134
9.9
.390
9.3
.366
PC board pattern (Bottom view)
5.08 5.08 5.08
.200 .200 .200 2.54
.100
10-.035 dia.
10-0.9 dia.
.100
2.54
7.62
.300
.100
2.54
Schematic (Bottom view)
(Reset condition)
Tolerance: ±0.1 ±.004
8
9131615
2
64
11
1
CAD Data
ASCTB17E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e
DS
NOTES
1. Coil connection
When connecting coils, ref er to the wiring
diagram to prevent mis-operation or
malfunction.
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
ASCTB17E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e