1-phase filters
FN 670
Two-stage performance EMI filter
Approvalsn Rated currents from 1.8 to 10A
n Very high differential and common-mode
attenuation
n Good high frequency attenuation
Typical applications
n FN 670 filters are designed for easy and
fast chassis mounting.
n FN 670 filters offer a perfect combination
of performance/size ratio.
n FN 670 two-stage filters provide a high
differential and common-mode attenuation
performance, based on chokes with high
saturation resistance and excellent thermal
behavior.
n FN 670 two-stage filters are designed for
very high noise suppression and high
frequency attenuation.
n Various terminal options allow you to
select the desired connection style.
n Custom-specific versions on request.
n Electrical and electronical equipment
n Consumer goods
n Power supplies
n Building automation
n Elevators and cranes
n Office automation equipment
n Datacom equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: dc to 400Hz
Rated currents: 1.8 to 10A @ 40°C max.
High potential test voltage: P –> E 2000VAC for 2 sec
P –> N 1100VDC for 2 sec
Temperature range (operation and storage): -25°C to +100°C (25/100/21)
Flammability corresponding to: UL 94V-2 or better
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
MTBF @ 40°C/230V (Mil-HB-217F): 300,000 hours
Typical electrical schematic
P
E
N
Line
Cx RL Cx1
P‘
N‘
Load
Cy L1
> Components > FN 670
Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40°C (25°C) @ 230VAC/50Hz L L1 Cx Cx1 Cy R connections -06 -07
[A] [µA] [mH] [mH] [nF] [nF] [nF] [kΩ] [g] [g]
Filter selection table
FN 670-1.8-.. 1.8 (2) 190 7.2 7.2 470 150 2.2 470 -06 -07 225 240
FN 670-3-.. 3 (3.4) 190 12.2 1.8 470 150 2.2 470 -06 -07 240 245
FN 670-6-.. 6 (6.7) 190 7 7 470 150 2.2 470 -06 -07 245 260
FN 670-10-.. 10 (11.2) 190 10.4 2.7 470 150 2.2 470 -06 -07 570 620
* To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 670-1.8-06, FN 670-10-07).
** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym; C = 0.1Ω/100Ω sym; D = 100Ω/0.1Ω sym
Typical filter attenuation
1.8A types 3A types
6A types 10A types
> Components > FN 670
Connection style -07, 10A types
A
C
E
G
L
F
H
J
I
KM
Q
D
BU
GNYE
BN
BU
BN
Connection style -06, 10A types
A
C
B
E
G
L
F
H
J
I
KM
N
Q
D
A
B E G
F
D
I
J
H
C
L
K
N
M
Mechanical data
Connection style -06, 1.8 to 6A types Connection style -07, 1.8 to 6A types
A
B E G
F
D
I
J
H
C
L
K
M
BU
GNYE
BN
BU
BN
Your local partner: To find your local partner within Schaffner’s global network, please go to www.schaffner.com July 2007
All dimensions in mm; 1 inch = 25.4mm
Tolerances according: ISO 2768 / EN 22768
1.8A 3A 6A 10A Tolerances
Dimensions
A 85 85 85 105 ±0.5
B 54 54 54 126 ±1 ±0.5
C 40.3 40.3 40.3 38 ±1
D 64.8 64.8 64.8 84.5 ±1
E 49.8 49.8 49.8 98.5 ±1
F 75 75 75 95 ±0.2
G 27 27 27 40 ±0.5
H 12.6 12.6 29.8 19 ±0.5
I 29.8 29.8 12.6 9.5 ±0.5
J 11.4 11.4 11.4 42.25 ±0.5
K 5.3 5.3 5.3 4.4
L 6.3 6.3 6.3 6
M 0.7 0.7 0.7
N 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8 6.3 x 0.8
Q 51 ±0.1
Connection style -07
AWG type wire AWG 18 AWG 18 AWG 16 AWG 14
Wire length 140 140 140 140 +5