For more Information
please call
1-800-Belden1
General Description:
20 AWG pairs stranded (7x28) bare copper conductors, twisted pairs, PVC insulation, overall Beldfoil shield
(100% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
120 7x28 BC - Bare Copper
Total Number of Conductors: 2
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.015
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
22 7x30 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .037
Outer Jacket Ripcord: Yes
Overall Cable
Overall Cabling Lay Length & Direction:
Direction
Left-hand Lay
Overall Nominal Diameter: 0.210 in.
Pair
Pair Color Code Chart:
Number Color
1Black & White
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +105°C
UL Temperature Rating: 105°C
Bulk Cable Weight: 29 lbs/1000 ft.
Max. Recommended Pulling Tension: 16 lbs.
Min. Bend Radius/Minor Axis: 2.100 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMG, ITC-ER, PLTC-ER
CEC/C(UL) Specification: CMG
AWM Specification: UL Style 2464 (300 V 80°C)
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
Page 1 of 2 01-05-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1033A Multi-Conductor - 300V Power-Limited Tray Cable
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 FT4 Loading
C(UL) Flame Test: FT4
IEEE Flame Test: 1202
Suitability
Suitability - Indoor: Yes
Suitability - Outdoor: Yes
Sunlight Resistance: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Surface Printing (Overall)
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Shield:
Capacitance (pF/ft)
55
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
30
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
9.5
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
38
Max. Operating Voltage - UL:
Voltage
300 V RMS (PLTC
CMG)
150 V RMS (ITC)
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1033A 0101000 1,000 FT 30.000 LB BLACK C 2 #20 PVC FS PVC
1033A 01010000 10,000 FT 270.000 LB BLACK C Z 2 #20 PVC FS PVC
Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 3 Revision Date: 01-14-2015
© 2017 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU).
Page 2 of 2 01-05-2017
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1033A Multi-Conductor - 300V Power-Limited Tray Cable
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Belden Wire & Cable:
1033A 0101000 1033A 01010000