© 2003 High Bandwidth Access, Inc. All rights reserved. Product specifications subject to change without notice.
FQ00 · FQ01 · FQ02 · FQ03 · FQ04 · FQ05
AUGUST 200
Flex
T
Async
5FA09C
Page 5 of 14
Symbol Rating Com’l & Ind’l Unit
VTERM Terminal Voltage with
respect to GND -0.5 to + 7 V
TSTG Storage Temperature -55 to +125 °C
IOUT DC Output Current -50 to +50 mA
NOTES:
Absolute Max Ratings are for reference only. Permanent damage to the device may
occur if extended period of operation is outside this range. Standard operation should
fall within the Recommended Operating Conditions.
Table 2. Absolute Maximum Ratings
FQ05, FQ04, FQ03, FQ02, FQ01, FQ00
Commercial tA = 12ns, 25ns,
35ns, 50ns Industrial tA = 25ns
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Unit
Recommended Operating Conditions
VCC Supply Voltage Com’l/Ind’l 4.5 5.0 5.5 4.5 5.0 5.5 V
GND Supply Voltage 0 0 0 0 0 0 V
VIH Input High Voltage
Com’l/Ind’l 2.0 - - 2.0 - - V
VIL Input Low Voltage
Com’l/Ind’l - - 0.8 - - 0.8 V
TA Operating Temperature 0 - 70 -40 - 85 °C
DC Electrical Characteristics
ILI(1) Input Leakage Current (any
input) -10 - 10 -10 - 10 µA
ILO Output Leakage Current -10 - 10 -10 - 10 µA
VOH Output Logic “1” Voltage,
IOH=-2mA 2.4 - - 2.4 - - V
VOL Output Logic “0” Voltage,
IOL = 8mA - - 0.4 - - 0.4 V
Power Consumption
ICC1(2,3,4) Active Power Supply
Current - - 80 - - 80 mA
ICC2(2,5) Standby Current - - 5 - - 5 mA
Capacitance at 1.0MHz Ambient Temperature (25°C)
Symbol Parameter Conditions Max. Unit
CIN(6) Input Capacitance VIN= 0V 8 pF
COUT(6) Output Capacitance VOUT= 0V 8 pF
NOTES:
1. Measurement with 0.4<=VIN<=Vcc
2. Tested with outputs open (IOUT=0)
3. Tested at f=20MHz
4. Typical Icc1=15+2*fs+0.02*CL*fc (in mA) with Vcc=5V, tA=25°C, fs=WCLK frequency=RCLK frequency (in MHz, using TTL levels), data switching
at fs/2, CL=Capacitive load (in PF)
5. All inputs = Vcc-0.2V or GND+0.2V and (R
___
=W
____
=RST
_______
=FIRST
___________
/RET
________
=VIH)
6. Design simulated, not tested.
Table 3. DC Specifications